• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.046 seconds

Estimation of Compressive Strength of Concrete with Granitic Aggregates : Rebound hammer and Ultrasonic Methods (화강암 골재를 사용한 콘크리트의 비파괴 시험에 의한 강도평가)

  • 김현우;이종태;윤기원;김병극;김무한;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.651-654
    • /
    • 1999
  • It is required that the compressive strength of concrete should be estimated accurately from the view point of efficient quality control and maintenance of buildings. In this paper, the equations to estimate the compressive strength of concrete using granite aggregates were suggested for both rebound hammer method and ultrasonic pulse velocity method. The results were compared with those for different age or curing condition. The rebound numbers for concrete cured in air were larger than for concrete cured in water. The difference between rebound numbers for concrete cured in water and in air was larger than for concrete cured in water. The difference between rebound numbers for concrete cured in water and in air was larger when water cement ratio was high. Also, with the increase of age, the velocity of ultrasonic pulse for concrete cured in air was measured larger when compared with that in water.

  • PDF

Assessing Impact of Reduction of Non-Point Source Pollution by BASINS/HSPF (HSPF를 이용한 비점오염원 삭감에 따른 효과 분석)

  • Bae, Dae-Hye;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.71-78
    • /
    • 2011
  • This paper aims to assessing impact of reduction of non-point source pollution in the Bokha Stream watershed. The BASINS/HSPF model was calibrated and verified for water flow and water qualities using Total Maximum Daily Load 8days data from 2006 to 2007. Accuracy of the BASINS/HSPF models in simulating hydrology and water quality was compared and there were somewhat differences of statistical results, but water flow and water quality were simulated in good conditions over the study period. The applicability of models was tested to evaluate non-point source control scenarios to response hydrology and water quality in the Bokha stream using various measures which include BMPs approach and change of landuse. The evaluation of reduction of non-point source pollution was developed using load-duration curve. Despite strong reduction of non-point source, there are not satiated target quality at low flow season.

Shipboard Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Kim, Ki-Wook;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.391-398
    • /
    • 2010
  • This study is currently giving priority to developing the ballast water treatment system using ozone(Ozone BWTS). The Ozone BWTS, were equipped on the real merchant vessel named as M. V. Hyundai Hong Kong to carried out shipboard tests of ballast water treatment system in accordance with orders of IMO G8 Guidelines. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-.2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

An Experimental Study of the Effects of Water Vapor in Intake Air on Comvustion and knock Characteristics in a Spark Ignition Engine (흡기중 수증기 함량이 스파크 점화기관의 연소 및 노킹에 미치는 영향에 관한 실험적 연구)

  • 이택헌;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.205-212
    • /
    • 1998
  • In this study, the effects of water vapor in inlet air on combustion efficiency, general performance, knock characteristics and emission gas concentration were investig- ated through the experiments of combustion and vibration analyses, emission gas analysis by changing water vapor quantity in inlet air with temperature and humidity auto control unit. With partial vapor pressure increase, the brake torque at wide open throttle status decreased and the average ignition delay angle increased, IMEP (indicated mean effective pressured using the integral and 3rd derivatives of filtered cylinder pressure as knock intensity, which matched well with the method of frequency power spectrum of block vibration signal. Water vapor in intake air had influence on the spark knock sensitivity. With the increase of water vapor content in intake air NOx emission was decreased and HC emission was increased.

  • PDF

Effect on Phytoplankton by Hydraulic-Gun-Aerators and Selective Withdrawal in Hoengseung Reservoir (횡성호 식물플랑크톤에 대한 간헐식 폭기의 영향과 선택취수)

  • Choi, Il-Hwan;Kim, Hak-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.1
    • /
    • pp.15-26
    • /
    • 2007
  • Surface water is the main drinking water source in Korea. Algal bloom caused by phytoplankton in reservoir is common event in every summer season. To prevent or control the algal blooms, artificial circulation system has been adopted in many reservoirs, including Hoengseung reservoir. Total 7 hydraulic-gun-aerators were installed around the intake tower in Hoengseung reservoir since 2000. This study is to elucidate the effects of hydraulic-gun-aerators on phytoplankton bloom, pH, DO, temperature and evaluate the selective withdrawal and vertical distribution of phytoplankton by means of submersible fluorescence probe, which features high correlation with a standard ISO method (r=0.90, P<0.0001) for chlorophyll-a quantification.

Water Quality Modeling and Environmantal Capacity in the Seom River Basin (섬강유역 환경용량 및 수질 Modeling)

  • 허인량;오근찬;최지용
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.80-86
    • /
    • 1998
  • Seom River was major branch of Namhan river, consist of primary basin that Wonjoo-city, Hoingsung-gun and primary contamination source was sewage from human lives. This study was evaluated production contamination loading of each branch basin and water quality grade and water quality simulation by QUAL2E to provide efficient contaminations source control. Rusult of survey, production loading of BOD, T-N, T-P were 26,591 kg/day, 4,560 kg/day, 731 kg/day resectively. Water quality analysis in 17 points of main stream were appeared that 1st grade(BOD 1 mg/l under) was 6 point, 2nd grade was 9 point and 3rd grade was 2 point. And result of water quality analysis for branch steram, first grade was evaluated 68.7%. Based of field data, calibration and verification result were in good agreement with mesured value within coefficient of variance were from 2.59% to 18.73%, from 6.39%, to 28.46%, respectively.

  • PDF

Effects of Carbonated Water Intake on Constipation in Elderly Patients Following a Cerebrovascular Accident (노인 뇌졸중환자의 변비완화를 위한 탄산수 음용의 효과)

  • Mun, Jae-Hee;Jun, Seong-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.2
    • /
    • pp.269-275
    • /
    • 2011
  • Purpose: This study was done to identify effects of carbonated water intake on constipation in elders who have experienced a cerebrovascular accident (CVA) and are bed-ridden. Methods: Forty elderly patients with CVA were randomly assigned to one of two groups in a double-blind study. Patients in the experimental group drank carbonated water and those in the control group drank tap water for two weeks. Six patients dropped out during the study period. Data were analyzed by repeated measured ANCOVA and the covariance was the dose of laxatives used for the two weeks. Results: Frequency of defecation increased significantly and symptoms of constipation decreased significantly for patients in the experimental group. Conclusion: The study results suggest that the intake of carbonated water is an effective method for the intervention of constipation in elderly patients with CVA.

A Study on the Sensor for Measuring Near-distance Variation by using Ultrasonic Transducer (초음파 트랜스듀서를 사용한 근접거리변동 측정용 센서개발에 관한 연구)

  • Yang, Yun-Suk;Shin, Young-Lok;Kim, Chul-Han;SaGong, Geon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.175-178
    • /
    • 2000
  • In this study, the ultrasonic transducer was fabricated with piezoceramic-polymer 1-3 type composites. Pulse-echo response of that transducer in water was investigated with variable water-level. Output of LED was under the control of the signal, which was analyzerd by the self-made Electric Unit. This paper represents automatically water-detecting system with variable water level. There was in good agreement water level between the virtual level and output signal by using the self-made water-detecting system.

  • PDF

Study on Utilizing Resources in Environment-friendly City - Operation method of rain storage tank for using rainwater as multipurpose - (친환경 도시에서의 자원활용에 관한 연구 -빗물의 다목적 활용을 위한 빗물저장조의 운전방법 -)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.359-366
    • /
    • 2003
  • Ecological society and energy conservative systems has become a subject of world wide attention. To examine the technologies of such systems as resource recycling society, this study is proposed for using rainwater as energy source and water resources in urban area. Useful informations for planning of utilizing rainfall as energy source, water resources, emergency water and controlling flood are discussed with model systems in urban area. It is calculated that the rate of utilizing rainwater, amounts of utilizing rainwater, substitution rate of supply water, amounts of overflow rainwater according to rain storage tank volume. By applying the past weather data, The optimum volume of rain water storage was calculated as 200m$^3$ which mean no benefits according to the increase of storage tank volumes. For optimum planing and control method at the model system, several running method of rainwater storage tank was calculated. The optimum operating method was the using weather data as 3hours weather forecast.

A study on the measurement methods used on a gauge for a spillway gate (여수로 수문개도 측정방식 연구)

  • Kim, Ki-Won;Hwang, In-Kwang;Kim, Ju-Yong;Song, Won-Il;Lee, Jin-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1716-1717
    • /
    • 2008
  • The spillway gate is the most important facility of the multi-purpose dam. we usually use various sensor and conversion technique to control the gate. In this study, we mathematically analyze the instrumental errors on the different winch types. And we will briefly explain the measurement methods used on a gauge for a spillway gate and the calculation method of the discharge water volume.

  • PDF