• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.046 seconds

Technical Application and Analysis for Reduction of Water Loss in Water Distribution Systems (상수도 관망의 유수율 제고 기술의 적용 및 분석)

  • Kim, Ju-Hwan;Lee, Doo-Jin;Bae, Cheol-Ho;Woo, Hyung-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.260-266
    • /
    • 2009
  • Non-revenue water reduction(NRW) technologies are implemented to evaluate and manage leakages scientifically in water distribution systems under local governments. A development of quantitative leakage indicator by measuring minimum night flow, pressure control policy by installation of PRV(pressure reducing valve) and the establishment of leakage prevention schemes by residual life modeling of deteriorated water pipes are reviewed and studied. Estimation models of allowable leakage are developed by measuring and analyzing minimum night flow at residential and commercial area in Nonsan city, which is suggested from UK water industry and can improve an existing leakage indicator for the evaluation of non-revenue water. Also, pressure control method is applied and analyzed to Uti distribution area in Sacheon city in the operation aspect. As results, $466\;m^3/day$ of leakage can be reduced and it is expected that 113million won of annual cost can be saved. In the part of corrosion velocity and residual life assessment, non-linear prediction models of residual thickness are proposed by assessment of corrosion velocity based on exposure years, soil and water quality etc., since the deteriorated water pipe play a major role to increase leakage. It is expected that collection data and analyzing results can be applied effectively and positively to reduce non-revenue water by accumulating surveying data and verifying the results in the business field of water distribution systems under local governments.

  • PDF

Water Quality Variation on the Unit Operation of Water Treatment Process When CCPP Index was Controlled for Internal Corrosion of Water Pipes (수도관 내부부식방지를 위한 CCPP 조절시 정수공정내에서의 수질변화)

  • Lee, Jae-In;Kim, Do-Hwan;Lee, Ji-Hyung;Kim, Dong-Youn;Hong, Soon-Heon;Shin, Pan-Sae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.362-368
    • /
    • 2005
  • The pH, alkalinity and calcium hardness could be adjusted by $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ addition in the water treatment process for corrosion protection of the water pipes. This research was performed to investigate the effect on the variation of water quality on the unit process by addition $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ in water treatment process. Carbon dioxide and lime were added before the coagulation basin and soda ash was added after the BAC process. pH and aklainity were increased at coagulation basin then after the water qualities had sustained similiarly to BAC process. There was no effect on turbidity and DOC removal efficiency during experimental period by addition\ $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ solution was added into clear well, the last process for optimum control of CCPP and is used mainly to control pH and alkalinity. In this research, average pH, alkalinity, and calcium hardness in treated water were 8.39, 61.4 mg/L as $CaCO_3$, 59.4 mg/L as $CaCO_3$, respectively and CCPP of treated water was higher than 29.5 mg/L to BAC process water, so adjusted water was expected to prevent internal corrosion of water pipe.

Development of Environmental Control System for High-Quality Shiitake Mushroom (Lentinus edodes (Berk.) Sing.) Production

  • Kwon, Jin-Kyung;Kim, Seung-Hee;Jeon, Jong-Gil;Kang, Youn-Ku;Jang, Kab-Yeol
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.342-351
    • /
    • 2018
  • Purpose: Recently, an increasing number of farms have been cultivating shiitake mushrooms using a sawdust substrate and a cooler/heater. In this study, an attempt was made to develop an environmental control system using a heat pump for cultivating high-quality shiitake mushrooms. Methods: An environmental control system, consisting of an air-to-water type heat pump, a thermal storage tank, and a radiator in a variable opening chamber, was designed and fabricated. The system was also installed in the cultivation facility of a farm cultivating shiitake mushrooms so as to compare the proposed control system with a conventional environmental control system using a cooler-condensing unit and an electric hot water boiler. Results: The uniformity of the environment was analyzed through environment measurements taken at several positions inside the cultivation facility. It was determined that the developed environmental control system is able to control the variations in temperature and relative humidity to within 1% and 3%, respectively. In addition, a maximum temperature difference of $30^{\circ}C$ (maximum of $35^{\circ}C$, minimum of $5^{\circ}C$) and a maximum relative humidity difference of 30% (maximum of 90%, minimum of 60%) can be attained within 30 min inside the cultivation facility through the cooling of the heat pump and heating of the radiator in a variable opening chamber. Thus, the developed control system can be used to cultivate high-quality shiitake mushrooms more effectively than a conventional cooler and heater. Conclusions: In comparison with a conventional environmental control system, the developed system decreased the yield of ordinary mushrooms by 65%, and increased that of high-quality mushrooms by 217%. This corresponds to a 16% increase in gross farm income. Consequently, the developed system is expected to improve the income of shiitake mushroom cultivating farms.

A Development of Integrated Control System for Platform Equipments of Unmanned Surface Vehicle (USV) (무인수상정 플랫폼 장비의 통합 제어 시스템 개발)

  • Hwang, Hun-Gyu;Kim, Hyun-Woo;Kim, Bae-Sung;Woo, Yun-Tae;Shin, Il-Sik;Shin, Ji-Hwan;Lee, Young-Jin;Choi, Byung-Woong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.8
    • /
    • pp.1611-1618
    • /
    • 2017
  • Recently, the development for USV-related technologies are actively growing up in military domain. The USV (unmanned surface vehicle) conducts various missions for national defense at maritime environment. For succeed the missions, the USV essentially needs an automatic and remote control platform which includes propulsion system, steering system, control system, power system and so on. In this paper, we developed an integrated control system for the platform equipments and verified effectiveness of the developed system. To do this, we designed a system architecture and implemented a main control system that processes and controls platform equipments by received command. Also we developed components of designed architecture such as engine control device, water-jet control device and power control device. For test and verify the developed system, we designed and made a test-bed of engine and water-jet with related parts, and proceeded a basin test for verifying the developed system based on the test-bed.

Effect of Tea Fungus/Kombucha Beverage on Lipid Metabolism in Streptozotocin-induced Diabetic Male Rats (발효홍차가 당뇨숫쥐의 지질 대사에 미치는 영향)

  • 고진복;최미애
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.3
    • /
    • pp.613-618
    • /
    • 1999
  • This study investigated the effect of tea fungus/kombucha(TF) beverage on body weights, pancreas weights, serum glucose and lipid concentrations of both normal and diabetic male rats. Sprague Dawley male rats weighing $140{\pm}10g$ were randomly assigned to one control and five streptozotocin(STZ) diabetic groups. Diabetic groups were divided into D control(TF free water), 20% TFD(20% TF in water), 40% TFD(40% TF in water), 20% TFSD(20% TF disinfection in water) and 40% TFSD(40% TF disinfection in water) according to the level of TF supplementation. Diabetes was experimentally induced by intraperitoneally administration of STZ in citrate buffer(pH4.3) after 3 week feeding of four experimental water. Animals were sacrificed at the 4 week of diabetic state. The diabetic groups showed significant decrease of body weight(-29.4~48.6g) compared with the control group(72.4g). Pancreatic weights relative to body weights in all diabetic groups were heavier than those of the control group. The levels of fasting serum glucose were higher in all diabetic groups than that of the control group. The concentrations of triglyceride in serum was lower in 20% TFD and 20% TFSD groups than in those D control group. The levels of total cholesterol, LDL cholesterol in serum and atherogenic index were significantly decreased in all(20 or 40%) TFD and TFSD groups than in those D control group, but those were similar to control group. The levels of HDL cholesterol in serum was similar to all groups, but HDL cholesterol/total cholesterol ratio were significantly increased in all(20 or 40%) TFD and TFSD groups than in those D control group. Liver triglyceride concentration of the all diabetic groups significantly decreased compared with the control group. Liver total cholesterol and phospholipid were not affected by TF and TFS feeding. The results indicated that tea fungus/kombucha beverage feeding improved the cholesterol, triglyceride and atherogenic index levels in diabetic rats.

  • PDF

Deriving Water Quality Criteria of Total Nitrogen for Nutrient Management in the Stream (하천에서의 영양물질 관리를 위한 총질소 환경기준 설정에 관한 연구)

  • Kim, Hak Kwan;Jeong, Han;Bae, Seung Jong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.3
    • /
    • pp.121-127
    • /
    • 2015
  • The objective of this study is to suggest the water quality criteria of total nitrogen in order to efficiently manage the nutrient pollution in the stream. For this, correlations between water quality parameters were examined using the water quality data collected from the water quality monitoring network in the four rivers between 2003 and 2012. T-N showed positive correlations with T-P (0.636), COD (0.577), BOD (0.574), TOC (0.440), and SS (0.367). The statistical analysis including percentile analysis for the T-N and T-P concentrations was utilized to develop the water quality criteria of T-N. The feasibility of the suggested water quality criteria was evaluated by calculating the achievement rate to water quality target at the representative points in mid-watershed, then the draft water quality standard of T-N was suggested. The suggested water quality standard of T-N in the stream may be used to efficiently control the nutrient pollution in the public water body.

A Study on the Variation of Ground Water Temperature for Development of Ground Water Source Heat Pump (지하수 열원 열펌프 개발을 위한 지하수 온도의 변화 특성 연구)

  • Nam Hyun Kyu;Kim Youngil;Seo Joung Ah;Shin Younggy
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.1 no.2
    • /
    • pp.1-6
    • /
    • 2005
  • Ground water source heat pumps are clean, energy-efficient and environment-friendly systems for cooling and heating. Although the initial cost of ground water source heat pump system is higher than that of air source, it is now widely accepted as an economical system since the installation cost can be returned within a short period of time due to its high efficiency. In a ground water source heat pump system, the variation of the ground water temperature is an important factor that influences the system performance. In this study, variation of the ground water temperature of a single well system is studied experimentally for various operating conditions. When ground water flow exists in the underground, the returned water exchanges heat efficiently with the ground and the temperature of the ground water remains nearly constant. Hence the short circuit problem is minimized. If an active flow of ground water flow exists in the underground, a singe well heat pumps system will be free of short circuit problem and can operate with high performance.

  • PDF

Development of Maintenance Management Tool for Water and Waste-Water Maintenance Management (상ㆍ하수도 유지관리를 위한 유지관리 툴 개발)

  • 김기우;조성언
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.195-198
    • /
    • 2001
  • This paper has studied and developed a tool for water and waste-water maintenance management with which builds a database of various construction information and makes easier the report writing and data searching. The maintenance management for water and waste and water is a method and system to control a water and waste-water scientifically and structurally, and is also a combination system that connects water and waste-water construction companies with the related department of government, or local government by using a database. It has also analyzed problems on controlling method of an existing water and waste water, and explained functions to improve fallouts of a conventional system and expected effects when using the improved program.

  • PDF

Effect of antibiotics treatment for edwardsiellosis of olive flounder Paralichthys olivaceus in biofloc environment (바이오플락 환경에서 넙치(Paralichthys olivaceus)의 에드워드병에 대한 항생제 치료 효과)

  • Park, Jung Jun;Kim, Seokryel
    • Journal of fish pathology
    • /
    • v.34 no.2
    • /
    • pp.225-231
    • /
    • 2021
  • In biofloc culture for olive flounder, Paralichthys olivaceus, the possibility of antibiotics treatment was investigated against edwardsiellosis. After inducing edwardsiellosis by immersion in Edwardsiella tarda 1.2 × 105/mL suspension, the survival trends on various biofloc water management and some physiological changes were observed. For biofloc water management, six types of water treatments were carried out, which were no exchange without antibiotics as negative control, the exchange to stored biofloc water, the exchange to stored biofloc water with 20% flow-through, the exchange to fresh biofloc water, half fresh biofloc water and half sea water, and the complete flow-through. There was no significant physicochemical change on water qualities in any type. The exchange to fresh biofloc water was shown the highest survival ratio as 72.3%, and in case of stored biofloc water with 20% flow-through, the survival ratio was also significantly high as 62%. Plasma glucose, cholesterol, total protein, calcium, and magnesium were analyzed as physiological index. Mostly, there was no significant change, but plasma cholesterol showed an initial decrease in low survival group, and an initial increase with high survival group. Consequently, antibiotic treatment against a bacterial disease during biofloc culture is possible as long as the biofloc water management follow along properly.