• 제목/요약/키워드: water compartment

검색결과 126건 처리시간 0.03초

해상 이동형 해수담수화 플랜트 선박의 저항 및 내항 성능 평가에 따른 장기 하중 추정 (Long-term Loads based on Evaluation of Resistance and Seakeeping Performances for a Desalination Plant Ship)

  • 이재빈;백광준;정준모
    • 한국해양공학회지
    • /
    • 제33권6호
    • /
    • pp.632-640
    • /
    • 2019
  • Desalination plant ships have been recently regarded as one of the probable solutions for drought seasons in many countries. Because desalination plants should be mounted on the desalination ships and special purpose storages such as salty waste water tanks are necessary, onboard and compartment arrangements would be distinguished from those of other conventional commercial ships. This paper introduces some basic design procedure including resistance/propulsion and seakeeping performances. The ship lines were improved step by step after modification of the ship lines and verification of resistance/propulsion performances using computational fluid dynamics (CFD). After finalization of the ship lines, the seakeeping performance was also evaluated to check motion behaviors and drive wave-induced loads such as the wave shear force and bending moment. It was proved that the predicted long-term vertical wave shear force and bending moment were significantly less than the rule-based ones, thus it is expected that the deliverables of this study will reduce the construction cost of desalination plant ships.

Simulation of Cardiovascular System for an Optimal Sodium Profiling in Hemodialysis

  • Lim, K.M.;Min, B.G.;Shim, E.B.
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제2권2호
    • /
    • pp.16-26
    • /
    • 2004
  • The object of this study is to develop a mathematical model of the hemodialysis system including the mechanism of solute kinetics, water exchange and also cardiovascular dynamics. The cardiovascular system model used in this study simulates the short-term transient and steady-state hemodynamic responses such as hypotension and disequilibrium syndrome (which are main complications to hemodialysis patients) during hemodialysis. It consists of a 12 lumped-parameter representation of the cardiovascular circulation connected to set-point models of the arterial baroreflexes, a kinetic model (hemodialysis system model) with 3 compartmental body fluids and 2 compartmental solutes. We formulate mathematically this model in terms of an electric analog model. All resistors and most capacitors are assumed to be linear. The control mechanisms are mediated by the information detected from arterial pressoreceptors, and they work on systemic arterial resistance, heart rate, and systemic venous unstressed volume. The hemodialysis model includes the dynamics of urea, creatinine, sodium and potassium in the intracellular and extracellular pools as well as fluid balance equations for the intracellular, interstitial, and plasma volumes. Model parameters are largely based on literature values. We have presented the results on the simulations performed by changing some model parameters with respect to their basal values. In each case, the percentage changes of each compartmental pressure, heart rate (HR), total systemic resistance (TSR), ventricular compliance, zero pressure filling volume and solute concentration profiles are represented during hemodialysis.

  • PDF

Electrochemical and Biochemical Analysis of Ethanol Fermentation of Zymomonas mobilis KCCM11336

  • Jeon, Bo-Young;Hwang, Tae-Sik;Park, Doo-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권7호
    • /
    • pp.666-674
    • /
    • 2009
  • An electrochemical bioreactor (ECB) composed of a cathode compartment and an air anode was used in this study to characterize the ethanol fermentation of Zymomonas mobilis. The cathode and air anode were constructed of modified graphite felt with neutral red (NR) and a modified porous carbon plate with cellulose acetate and porous ceramic membrane, respectively. The air anode operates as a catalyst to generate protons and electrons from water. The growth and ethanol production of Z. mobilis were 50% higher in the ECB than were observed under anoxic nitrogen conditions. Ethanol production by growing cells and the crude enzyme of Z. mobilis were significantly lower under aerobic conditions than under other conditions. The growing cells and crude enzyme of Z. mobilis did not catalyze ethanol production from pyruvate and acetaldehyde. The membrane fraction of crude enzyme catalyzed ethanol production from glucose, but the soluble fraction did not. NADH was oxidized to $NAD^+$in association with $H_2O_2$reduction, via the catalysis of crude enzyme. Our results suggested that NADH/$NAD^+$balance may be a critical factor for ethanol production from glucose in the metabolism of Z. mobilis, and that the metabolic activity of both growing cells and crude enzyme for ethanol fermentation may be induced in the presence of glucose.

Escape response of juvenile seabream with rockfish from the separating model codend in tank experiments

  • KIM, Yonghae
    • 수산해양기술연구
    • /
    • 제52권2호
    • /
    • pp.88-95
    • /
    • 2016
  • Most grid sorting has been used to sort out flatfish in shrimp fisheries, while double grid systems have been tested to separate smaller shrimp. The escape of juvenile red seabream through separating panels made with steel grids or large mesh tested for masking effects in a two-species system. Fish behavior was observed in a circulating water tank. The escape rate was 20% greater with the separating codends than with the normal codend in the single-species experiments. The rates in the two-species experiments were 30% or 20% greater than the single-species rates for the normal or separating codends, respectively. The seabream retention rates in the grid separator codend decreased as rockfish retention increased, possibly due to a threat effect. Conversely, the retention rate of both species increased concurrently in the net separator, possibly due to a masking effect. The escape rates of juvenile red seabream varied by compartment in the mesh separating codend. These results suggest that grid separating codends can be used in the field as towed fishing gear to reduce juvenile catch.

오존 전처리 공정이 생물활성탄 공정의 효율에 미치는 영향

  • 이상훈;문순식;신종철;최광근;박대원;심상준;이진원
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2002년도 생물공학의 동향 (X)
    • /
    • pp.361-364
    • /
    • 2002
  • 본 연구에서는 오존과 생물활성탄을 연계시킨 공정을 통하여 용존 유기물질의 제거 경향을 살펴보았다. 오존 처리를 거치면서 원수중의 난분해성 용존 유기물질과 같이 생물학적 분해 속도가 느린 화합물의 상당량이 저분자 형태로 전환되었음을 파악할 수 있었으며, 오존 처리후의 생분해성의 향상에 의해 흡착의 부담이 경감되어 활성탄의 수명이 연장되는 것으로 조사되었다. 생물활성탄 반응조 내에서 여층 깊이에 따른 DOC 제거 경향을 알아본 결과, 전체 제거량의 약 50%가 column 상단에서 제거되었으며, 따라서 짧은 EBCT 에서도 용존 유기탄소의 제거는 용이한 것을 사료된다. 또한 유기 오염에 대한 지표로서 국내외에서 일반적으로 고도정수처리의 처리 대상물질로 선정되어 있는 암모니아성 질소의 제거는 75.9%로 상당히 높은 제거율을 나타내었다.

  • PDF

전기장과 이온교환막을 이용한 토양에서의 중금속 제거에 대한 연구 (A study on the removal of heavy metals from soils using electrokinetic soil processing and ion exchange membrane)

  • 김순오
    • 자원환경지질
    • /
    • 제32권1호
    • /
    • pp.43-51
    • /
    • 1999
  • In order to remediate hazardous waste site, a process of electrokinetically purging chemicals from saturated soil is examined by laboratory experiments. Electrokinetic soil remediation is one of the most promising soil decontamination processes that habe igh removal efficiency and time-effectiveness in low-permeability soils such as clay. Being combined with several mechanisms-electromigration, elec troosmosis, diffusion and electrolysis of water, electrokinetic soil processing can remove non-polar organics as well as ionic contaminants. The objectives of this study are; 1) the exploration of the feasibility of electrokinetic soil processing on the removal of heavy metals, 2) the investigation of applicability to the tailing-soils in aban doned mining area, 3) the examination of effects of soil pH and conductivity on the transport phenomena of elements in soils, and 4) the investigation of the applicability of the ionexchange membrance to the efficient collection of heavy metals removed from contaminated soils. With the result of this study, it is suggested that the removal efficiency is significantly influenced by applied voltage & current, type of purging solutions, soil pH, permeability and zeta potentials of soil. Although further study should be needed, it is possible to collect removed heavy metals with ion-exchange membrance in cathode compartment.

  • PDF

엘리베이터 피난계산 고려인자에 관한 연구 (A Study on the Consideration Factors for the Calculation of Elevator Evacuation Time)

  • 김학중;박용환
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.8-14
    • /
    • 2010
  • 최근 건축물이 초고층화, 심부화 되면서 화재발생시 거주자의 피난시간 단축을 위한 노력이 필요한 시점이다. 화재시 엘리베이터를 피난도구로 사용하는 것은 현재까지는 득보다 실이 많아 금지되어 왔다. 하지만 엘리베이터를 피난에 적합하고 화재시 화염 및 연기에 안전하도록 설계하여 피난에 이용하므로써 전체 피난시간을 단축하려는 연구가 진행되고 있다. 본 연구에서는 실제 엘리베이터를 이용한 피난시 피난시간을 계산하기 위하여 고려되어야 할 인자에 대하여 분석하고자 한다. 엘리베이터 피난계산에 고려되어야 할 인자는 시작시간, 왕복이동시간이 있으며, 왕복 이동시간은 대기시간과 운행시간으로 나뉘게 된다. 이러한 인자들의 조합과 효율을 반영하여 전체 엘리베이터 이용한 피난시간을 계산하게 된다. 엘리베이터를 피난용으로 활용하기 위해서는 제연, 구획화, 방수, 전력공급과 같은 부가적인 연구가 필요하다.

Drug Targeting to Lungs by Way of Microspheres

  • Harsha, N. Sree;Rani, R.H. Shobha
    • Archives of Pharmacal Research
    • /
    • 제29권7호
    • /
    • pp.598-604
    • /
    • 2006
  • In many conventional drug delivery systems in vogue, failure to deliver efficient drug delivery at the target site/organs; is evident as a result, less efficacious pharmacological response is elicited. Microspheres can be derived a remedial measure which can improve site-specific drug delivery to a considerable extent. As an application, Lung-targeting Ofloxacin-loaded gelatin microspheres (GLOME) were prepared by water in oil emulsion method. The Central Composite Design (CCD) was used to optimize the process of preparation, the appearance and size distribution were examined by scanning electron microscopy, the aspects such as in vitro release characteristics, stability, drug loading, loading efficiency, pharmacokinetics and tissue distribution in albino mice were studied. The experimental results showed that the microspheres in the range of $0.32-22\;{\mu}m$. The drug loading and loading efficiency were 61.05 and 91.55% respectively. The in vitro release profile of the microspheres matched the korsmeyer’s peppas release pattern, and release at 1h was 42%, while for the original drug, ofloxacin under the same conditions 90.02% released in the first half an hour. After i.v. administration (15 min), the drug concentration of microspheres group in lung in albino mice was $1048\;{\mu}g/g$, while that of controlled group was $6.77\;{\mu}g/g$. GLOME found to release the drug to a maximum extent in the target tissue, lungs.

조직 특성 MR 조영제를 이용한 쥐의 간세포막의 물분자 교환 및 투과율의 MR 측정기법 (MR Study of Wate Exchange and Cell Membrane Permeability in Rat Liver Cells Using a Tissue-Specific MR Contrast Agent)

  • Yongmin Chang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제2권1호
    • /
    • pp.73-82
    • /
    • 1998
  • 목적 : 간특정 MR 조영제를 이요하여 간세포의 세포막을 통한 물분자의 교환 및 세포막 투과율을 정확히 측정 할 수 있는 MR 기법을 개발하고자 하였다. 대상 및 방법 : 쥐의 간세포를 분리하여 낸 후 NMR 측정을 시도하엿다. 모든 실험은 0.02MHz부터 60 MHz까지 양성자의 Larmor 주파수를 변화시킬 수 있는 IBM형 field cycling relaxometer를 사용하여 시행하였으며 spin-echo 펄스열을 사용하여 T1 자기이완시간을 측정하였다. 전오도의 간특정 조영제인 Gd-EOB-DTPA를 함유하고 있는 간세포 샘플로부터 획득한 T1 데이터를 연속분포 분석법을 사용하여 분석하였으며 이때 이론적 모델로는 Two compartmental exchange 모델을 이용하였다. 결과 : 간세포내의 물분자의 평균 거주시간은 약 250 msec이며 간세포막의 투과율에 대한 최저치는 $(1.3{\pm}0.1){\;}{\times}{\;}10^{-3}cm/sec$ 이었다. 자기이완시간의 연속적인 분포도를 구할 수 있는 CONTIN 분석기법을 적용한 결과 확산적 물분자 교환이 일어남을 밝혔고 이러한 확산적 교환의 정도가 간세포의 경우 세포내 공간에서는 작지 않다는 사실을 규명 할 수 있었다. 결론 : 연속분포 분석기법을 적용하는 경우 Gd-EOB-DTPA는 간세포에서의 물분자의 교환정도 및 세포막의 물분자에 대한 투과율을 측정하는데 매우 유용한 방법임을 확인하였고 간세포에서의 물분자의 교환속도는 적혈구에서의 물분자 교환 속도에 비해 매우 느리다는 사실을 확인하였다. 따라서 조직 특정 조영제는 해당 조직 혹은 세포의 세포막 투과율과 같은 생리학적 정보를 알아낼 수 있는 기능적 조영제로서의 유용성을 입증할 수 있었다.

  • PDF

CFD 검증용 데이터베이스 구축을 위한 손상 선박의 횡동요 감쇠 운동에 대한 실험적 연구 (Experimental Study on Free Roll Decay Motions of a Damaged Ship for CFD Validation Database)

  • 이성균;유지명;이현호;이신형;이기표
    • 대한조선학회논문집
    • /
    • 제49권1호
    • /
    • pp.52-59
    • /
    • 2012
  • Among many factors to be considered for higher safety level requirements, the hull stability in intact and damaged conditions in seaways is of utmost importance. Since the assessment of a damaged ship is complicated due to the highly non-linear behavior, it is widely acknowledged that computational fluid dynamics (CFD) methods are one of the most feasible approaches. Although many research activities are being reported on the damaged ship stability recently, most of them are not designed for validation of CFD studies. In this study, well-designed model tests were performed to build a CFD validation database, which is essential in developing better CFD methods for the damage stability assessment. The geometry of the damaged compartment and test conditions were determined based on preliminary CFD simulations. Free roll decay tests in calm water with both intact and damaged ships were performed and the roll motion characteristics were compared. The damaged ship showed a larger roll damping coefficient and more rapid decrease of roll amplitude than the intact ship. The primary reason of these efforts can be explained by the movement of the flooded water.