• Title/Summary/Keyword: wastewater treatment systems

Search Result 282, Processing Time 0.029 seconds

Effects of Indirect Wastewater Reuse on Water Quality and Soil Environment in Paddy Fields (간접하수재이용에 따른 논에서의 수질 및 토양환경 영향 분석)

  • Jeong, Han Seok;Park, Ji Hoon;Seong, Choung Hyun;Jang, Tae Il;Kang, Moon Seong;Park, Seung Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.3
    • /
    • pp.91-104
    • /
    • 2013
  • The objectives of this study were to monitor and assess the environmental impacts of indirect wastewater reuse on water quality and soil in paddy fields. Yongin monitoring site (YI) irrigated from agricultural reservoir and Osan monitoring site (OS) irrigated with treated wastewater diluted with stream water were selected as control and treatment, respectively. Monitoring results for irrigation water quality showed a significant statistical difference in salinity, exchangeable cation and nutrients. Pond water quality showed a similar tendency with irrigation water except for the decreased difference in nutrients due to the fertilization impact. Soil chemical properties mainly influenced by fertilization activity such as T-N, T-P, and $P_2O_5$ were changed similarly in soil profiles of both monitoring sites, while the properties, EC, Ca, Mg, and Na, mainly effected by irrigation water quality showed a considerable change with time and soil depth in treatment plots. Heavy metal contents in paddy soil of both control and treatment did not exceed the soil contamination warning standards. This study could contribute to suggest the irrigation water quality standards and proper agricultural practices including fertilization for indirect wastewater reuse, although long-term monitoring is needed to get more scientific results.

Sensitivity Analysis and Parameter Estimation of Activated Sludge Model Using Weighted Effluent Quality Index (가중유출수질지표를 이용한 활성오니공정모델의 민감도 분석과 매개변수 보정)

  • Lee, Won-Young;Kim, Min-Han;Kim, Young-Whang;Lee, In-Beum;Yoo, Chang-Kyoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1174-1179
    • /
    • 2008
  • Many modeling and calibration methods have been developed to analyze and design the biological wastewater treatment process. For the systematic use of activated sludge model (ASM) in a real treatment process, a most important step in this usage is a calibration which can find a key parameter set of ASM, which depends on the microorganism communities and the process conditions of the plants. In this paper, a standardized calibration protocol of the ASM model is developed. First, a weighted effluent quality index(WEQI) is suggested far a calibration protocol. Second, the most sensitive parameter set is determined by a sensitive analysis based on WEQI and then a parameter optimization method are used for a systematic calibration of key parameters. The proposed method is applied to a calibration problems of the single carbon removal process. The results of the sensitivity analysis and parameter estimation based on a WEQI shows a quite reasonable parameter set and precisely estimated parameters, which can improve the quality and the efficiency of the modeling and the prediction of ASM model. Moreover, it can be used for a calibration scheme of other biological processes, such as sequence batch reactor, anaerobic digestion process with a dedicated methodology.

Comparition of Submerged / Pressurized Type Membrane System by DRF and Long-Term Results in MF Drinking Water Treatment (MF막여과 정수처리에서 장기운전 결과 및 DRF를 이용한 침지식 / 가압식 시스템의 비교 평가)

  • Ha, Keum Ryul;Kim, Kwan Yeop;Kim, Hyo-Sang;Lee, Yong Soo;Song, June Sup;Kim, Chung Hwan;Yeom, Ick Tae;Lee, Yong Hoon;Kim, Hyung Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.79-86
    • /
    • 2008
  • In Korea, most of the drinking water treatment relied upon the availability of the surface water, of which the raw water quality varied significantly by season and location. Therefore, the comparison of two operation modes (Pressurized type and Submerged type membrane system) must be estimated before the long-term establishment of two systems. In this study, two pilot-scale microfiltration systems with the capacity of $50m^3/day$ were installed and operated in two different modes, and the applicability of the system was determined based on the results such as the TMP (Trans-Membrane Pressure) and flux. For quantitatively comparing the two systems, a new concept, DRF (Differential Resistance Fraction) was introduced. The accumulated sum of the permeate after each cycle of chemical cleaning was also used as a tool for the system comparison.

Fuzzy Polynomial Neural Network Algorithm using GMDH Mehtod and its Application to the Wastewater Treatment Process (GMDH 방법에 의한 FPNN 일고리즘과 폐스처리공정에의 응용)

  • Oh, Sung-Kwon;Hwang, Hyung-Soo;Ahn, Tae-Chon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.7 no.2
    • /
    • pp.96-105
    • /
    • 1997
  • In this paper, A new design method of fuzzy modeling is presented for the model identification of nonlinear complex systems. The proposed FPNN(Fuzzy Polynomial Neural Network) modeling implements system structure and parameter identification using GMDH(Group Method of Data Handling) method and linguistic fuzzy implication rules from input and output data of processes. In order to identify premise structure and parameter of fuzzy implication rules, GMDH method and regression polynomial fuzzy reasoning method are used and the least square method is utilized for the identification of optimum consequence parameters. Time series data for gas furnace and those for wastewater treatment process are used for the purpose of evaluating the performance of the proposed FPNN modeling. The results show that the proposed method can produce the fuzzy model with higher accuracy than other works achieved previously.

  • PDF

Optimum Configuration Method and Livestock Wastewater Loding for Treating Livestock Wastewater in Constructed Wetlands by Natural Purification Method (자연정화공법에 의한 인공습지 축산폐수처리 시스템의 최적 조합방법 및 부하량)

  • Park, Jong-Hwan;Seo, Dong-Cheol;Kim, Ah-Reum;Kim, Sung-Hun;Lee, Seong-Tae;Jeong, Tae-Uk;Choi, Jeong-Ho;Kim, Hyun-Ook;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.2
    • /
    • pp.278-284
    • /
    • 2011
  • To obtain optimum configuration method and livestock wastewater loading in small-scale livestock wastewater apparatus by natural purification method for treating livestock wastewater, the small-scale livestock wastewater apparatuses were constructed with 9 kinds of combined systems such as aerobic bed (ae)-anaerobic bed (an), ae-ae, ae-anoxic bed (ox), an-an, an-ae, an-ox, ox-ae, ox-an and ox-ox livestock wastewater treatment apparatuses. Under different configuration methods, the removal rate of COD in Ae-Ae and Ae-An livestock wastewater treatment apparatus was higher than that in other configuration methods. The removal rate of T-N in Ae-An livestock wastewater treatment apparatus was higher than that in other configuration methods. Removal rates of SS and T-P were not different regardless of configureation methods in small-scale livestock wastewater treatment apparatus. Under different livestock wastewater loading, the removal rates of pollutants were higher in the order of $50L\;m^{-2}\;day^{-1}{\fallingdotseq}100L\;m^{-2}\;day^{-1}\;>\;200L\;m^{-2}\;day^{-1}$. Therefore, optimum configuration method was Ae-An livestock wastewater treatment apparatus, and optimum livestock wastewater loding was $100L\;m^{-2}\;day^{-1}$ in small-scale livestock wastewater treatment apparatus.

Approaches to Internal Corrosion Control Technologies by Controlling Water Quality in Water Treatment Systems (수질제어를 통한 관 내부 부식방지 기술의 정수처리공정 적용방안)

  • Seo, Dae-Keun;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.509-518
    • /
    • 2006
  • Although final water of domestic water treatment plants almost contains highly corrosive characteristics, the countermeasures for eliminating internal corrosion of pipeline system have not been conducted yet by controlling water quality in plants. The technologies of internal corrosion control are to control water quality parameters(pH, Alkalinity, and Calcium Hardness etc.) and to use corrosion inhibitor. Under the conditions of domestic water treatment, first of all, the technologies of adjusting water quality parameters has to be considered. Otherwise, The technology of using corrosion inhibitor is favorably thought to be applied with the technology of adjusting water quality parameters in accordance with the result of availability for water treatment process. Since the technology of adjusting water quality parameter influences on other water treatment processes, the guideline of water quality management to be apt for water quality characteristic is required to be estabilished. While the selection of proper chemicals and technologies is dependent upon the raw water characteristics and water treatment process, typically, the technology of $Ca(OH)_2$ & $CO_2$ additions is considered more effective than other technologies in order to adjust pH and Alkalinity, increase $Ca^{2+}$ and form $CaCO_3$ film

Discharge Standards of Kitchen-Disposer Wastewater by Treatment Types (디스포저(부엌용 오물분쇄기)-배수 전처리 방식 별 수질기준)

  • Chang, Ho Nam;Jeong, Chang Moon;Kang, Jong Won;Choi, Jin-dal-rae;Park, Young Sook;Ku, Ja-Kong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.2
    • /
    • pp.55-69
    • /
    • 2011
  • Use of disposer at the kitchens of Korean apartments is inevitable in treating their foodwaste having a water content of more than 80%. Also we have to ensure that this extra disposer-foodwaste BOD loadings be treated properly by installing/operating a pre-treatment system before this wastewater enters public sewer system. However, the degree of BOD removal should not be excessive since a BOD/N ratio higher than 5 is required for removing N/P at a municipal wastewater treatment plant. The removal of BOD/N in the pretreatment system rather than BOD alone can be an alternative solution in solving this problem. The particles separated by sedimentation, screen or packed-bed can be anaerobically digested at apartment sites to generate biogas that can be used for simple digester heating and to generate volatile fatty acids (VFAs) for nitrogen removal. We suggest that Korean government grants a temporary license (say for 5 years) to foodwaste treatment companies in collaboration with apartment construction companies which may do business and develop various kinds of disposer-foodwaste treatment systems in diverse wastewater discharge systems of Korean apartments.

A Rapid Method for Monitoring of Gram-positive Bacteria in Wastewater Treatment Systems (폐수처리시스템에서의 그람 양성 세균 모니터링 방법)

  • Nam, Ji-Hyun;Bae, Woo-Keun;Lee, Dong-Hun
    • Korean Journal of Microbiology
    • /
    • v.47 no.1
    • /
    • pp.50-55
    • /
    • 2011
  • A simple and rapid method was developed for monitoring of Gram-positive bacteria in the wastewater treatment system. Culture suspensions of 4 Gram-positive and 4 Gram-negative strains were filtrated and stained with a polyethersulfone membrane filter and Toluidine Blue-O. To establish quantitative color image analysis, the intensity value of RGB (red-green-blue) color of a scanned filter image was analyzed with a photographic program. Red and green color values of Gram-positive bacteria were higher than those of Gram-negative bacteria. This method was applied to the activated sludge mixed with the Gram-positive bacteria. Although evaluation was difficult due to the irregular size and shape of flocs, the population of Gram-positive bacteria in the activated sludge could be monitored with floc dispersion technique. The more amounts of Gram-positive bacteria in the activated sludge led to the increase of red and green color values. This method provides a rapid and quantitative measurement of Gram-positive bacteria within the wastewater treatment systems.

Estimation of energy self-sufficiency in municipal wastewater treatment plant using simulated solar photovoltaic performance (태양광발전시스템 성능 시뮬레이션을 통한 하수처리장 에너지자립율 산정)

  • An, Young-Sub;Kim, Sung-Tae;Chae, Kyu-Jung;Kang, Ji-Hoon;Yang, Hee-Jung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.291-296
    • /
    • 2011
  • This paper presents energy self-sufficiency simulated in municipal wastewater treatment plants (WWTPs) by adopting solar energy production systems that vary with installation conditions. Relative to the national average energy consumption in WWTPs, the employment of 100 kW photovoltaics (PVs) was simulated to achieve 2.75% of energy self-sufficiency. The simulated results suggested that the installation of PVs toward South or South west would produce the highest energy self-sufficiency in WWTPs. When super-hydrophilic coating was employed in the conventional PVs, 5% of additional solar energy production was achievable as compared to uncoated conventional PVs. When 100 kW of PVs were installed in a future test-bed site, Kihyeung Respida located in Yougin, Sourth Korea, the energy self-sufficiency by solar energy was simulated to be 1.77% (2010). The simulated energy self-sufficiency by azimuth(direction) will be useful reference for practitioners in designing the solar PV systems in the WWTPs.

  • PDF

Wastewater Utilization: A Place for Managed Wetlands - Review -

  • Humenik, F.J.;Szogi, A.A.;Hunt, P.G.;Broome, S.;Rice, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.4
    • /
    • pp.629-632
    • /
    • 1999
  • Constructed wetlands are being used for the removal of nutrients from livestock wastewater. However, natural vegetation typically used in constructed wetlands does not have marketable value. As an alternative, agronomic plants grown under flooded or saturated soil conditions that promote denitrification can be used. Studies on constructed wetlands for swine wastewater were conducted in wetland cells that contained either natural wetland plants or a combination of soybeans and rice for two years with the objective of maximum nitrogen reduction to minimize the amount of land required for terminal treatment. Three systems, of two 3.6 by 33.5 m wetland cells connected in series were used; two systems each contained a different combination of emergent wetland vegetation: rush/bulrush (system 1) and bur-reed/cattail (system 2). The third system contained soybean (Glycine max) in saturated-soil-culture (SSC) in the first cell, and flooded rice (Oryza sativa) in the second cell. Nitrogen (N) loading rates of 3 and $10kg\;ha^{-1}\;day^{-1}$ were used in the first and second years, respectively. These loading rates were obtained by mixing swine lagoon liquid with fresh water before it was applied to the wetland. The nutrient removal efficiency was similar in the rush/bulrush, bur-reed/cattails and agronomic plant systems. Mean mass removal of N was 94 % at the loading rate of $3kg\;N\;ha^{-1}\;day^{-1}$ and decreased to 71% at the higher rate of $10kg\;N\;ha^{-1}\;day^{-1}$. The two years means for above-ground dry matter production for rush/bulrushes and bur-reed/cattails was l2 and $33Mg\;ha^{-1}$, respectively. Flooded rice yield was $4.5Mg\;ha^{-1}$ and soybean grown in saturation culture yielded $2.8Mg\;ha^{-1}$. Additionally, the performance of seven soybean cultivars using SSC in constructed wetlands with swine wastewater as the water source was evaluated for two years, The cultivar Young had the highest yield with 4.0 and $2.8Mg\;ha^{-1}$ in each year, This indicated that production of acceptable soybean yields in constructed wetlands seems feasible with SSC using swine lagoon liquid. Two microcosms studies were established to further investigate the management of constructed wetlands. In the first microcosm experiment, the effects of swine lagoon liquid on the growth of wetland plants at half (about 175 mg/l ammonia) and full strength (about 350 mg/l ammonia) was investigated. It was concluded that wetland plants can grow well in at least half strength lagoon liquid. In the second microcosm experiment, sequencing nitrification-wetland treatments was studied. When nitrified lagoon liquid was added in batch applications ($48kg\;N\;ha^{-1}\;day^{-1}$) to wetland microcosms the nitrogen removal rate was four to five times higher than when non-nitrified lagoon liquid was added. Wetland microcosms with plants were more effective than those with bare soil. These results suggest that vegetated wetlands with nitrification pretreatment are viable treatment systems for removal of large quantities of nitrogen from swine lagoon liquid.