• Title/Summary/Keyword: wastewater sampling

Search Result 99, Processing Time 0.024 seconds

Investigation and Analysis of Unit Industrial Water Usage Considering Latest Industrial Trend (최신 산업동향을 고려한 공업단지 사용량 원단위 분석 연구)

  • Kim, Kibum;Yu, Youngjun;Choi, Woojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.447-457
    • /
    • 2017
  • This study derived the unit of industrial water usage reflecting the latest industry trends. Available for establishing plans such as the master plan for water supply system and analyzed changes in the basic unit by a comparison with the current basic unit values. This study analyzed 4,038 samples with a sampling error of less than 1.5 % at the 95 % confidence level after removing outliers according to a log-normal distribution. As a result, the unit of industrial water usage per site area in the whole manufacturing industry was 7.11 m3/1,000m2/d. The ten industrial categories (C10, C13, C20, C21, C22, C25, C27, C30, C32, C33) showed a similar unit value compared to before, and the four industrials categories (C11, C17, C22, C31) showed a more unit value than before. With regard to the nine industrial categories (C14, C15, C16, C18, C19, C24, C26, C28, C29), the unit value decreased. Cases that companies examined before were the same as the companies examined in this study were analyzed. The result that the changes in the unit industrial water usage were reasonable was obtained. However, in some industrial categories (C17, C14, C24, C29), the unit value was changed by a small number of companies with large-scale water use or unit value of sampling had a large deviation. It was considered necessary to survey them periodically. The unit of industrial water usage derived by the survey in this study reflects the current industrial trends in 2016. Water use in manufacturing companies has continuously changed by the development of manufacturing technologies and simplification of manufacturing processes. In order to deal with this, it is considered necessary to survey the usage of industrial water periodically from a long-term perspective.

Application Assessment of Passive Sampling to Monitor Polybrominated Diphenyl Ethers in Water Environment as Alternative Sampling Method for Grab Sampling (수계 중 폴리브롬화 디페닐에테르 모니터링을 위한 Passive Sampling 적용 및 그랩 시료채취법의 대체 활용가능성 평가)

  • Kim, Un-Jung;Seo, Chang Dong;Im, Tae-Hyo;Oh, Jeong-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.1
    • /
    • pp.45-51
    • /
    • 2015
  • PBDEs (polybrominated diphenyl ehters) are rarely dissolved in water due to their strong hydrophobicity and large molecular mass so not many researches were done in aqueous environment compared to other environmental compartments. However, the mass loading from wastewater treatment plant into aquatic environment, re-suspension from bottom sediment and partitioning from floating particles and colloids may not be negligible. It is, therefore, important but also difficult to investigate PBDEs in water environment. Recent overcoming resolution towards this barrier to monitor hydrophobic organic compounds in aquatic environment is using passive sampling technique like semipermeable membrane device. By using passive sampling, it might be possible to obtain long-term reproducible monitoring result and detect the trace amounts of PBDEs, with controlling fluctuation of surrounding environmental factors during the sampling event. So therefore, this study is purposed to confirm the possibility of using SPMD (semi-permeable membrane device) as water monitoring tool. Grab samples, composite samples and SPMDs were applied in river bank to evaluate the concentration difference and temporal fluctuation by various water sampling method, and to assess the water concentration prediction capability of SPMD for the PBDEs.

Production of Hydrogen Sulfide Gas from Sediments in Concrete Sewer (하수관내 침전물의 황화수소가스 발생에 관한 연구)

  • Cho, Sun-Hyoung;Ko, Young-Song;Nam, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.3
    • /
    • pp.83-91
    • /
    • 1996
  • The pulverized wastes originated from kitchen garbage grinder cause an additional load in sewage treatment plant and water environment. Therefore, several problems occur in sewer, such as microbial corrosion, odor, psychoda and fly interrupting flow of sewage etc. by their precipitation with earth and sand. This study was conducted on two experiments: hydrogen sulfide gas generation from sediments in sewer and anaerobic batch test. In anaerobic batch test, gas generation was increased when organic compounds were increased in concentration. Sulfide was decreased upon decreasing in sulfate concentration. In $H_2S$ gas generation test along the depth of sediments there were two different sampling sites which are apart from about 50 cm each other in a menhole. The one has the thickness of 55 cm from the surface, the other, of 60 cm. The hydrogen sulfide gas production rates were measured based on ranges from 0 to 10 cm, 10 to 20 cm, 20 to 30 cm for two samples. The results obtained were 1.08, between 0 to 10 cm in depth for the sample thickness of 55 cm and 3.07, 5.36, $5.42{\mu}g/g-VS{\cdot}hr$ in order of depth for the sample thickness of 60 cm, respectively.

  • PDF

Water Quality Characteristics of Nonpoint Pollutants based on the Road Type (도로 유형별 비점오염원의 수질특성)

  • Jang, Dae-Chang;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.631-636
    • /
    • 2009
  • This study has its intention to investigate the water quality of non-point source which is runoff from roads. We have classified and selected twelve sites as city road, industrial road, national road and mountain road by considering their traffic volume and surroundings. Water quality was analyzed based on BOD, COD, SS, T-N and T-P and the concentrations were measured by sampling after rainfall with the interval of 10 minutes, 20 minutes, and 30 minutes. BOD was the highest in city road with 57.6 mg/L and the lowest in mountain road with 45.0 mg/L. For COD, the highest concentration in industrial road was 146.5 mg/L and the lowest was in mountain road with 98.0 mg/L. The run off concentration of SS was up to maximum 630.0 mg/L (average 280.4 mg/L) which was remarkable compared to other types of road. It showed its lowest concentration in national road with 76.0 mg/L. T-N and T-P were the highest in industrial road and the lowest in mountain road. We found out that the runoff concentration was high with large amount of traffic volume and it seemed to be high in city road and industrial road where they were largely affected by their surroundings. Relatively, national road and mountain road seemed to show low concentration as they have less traffic volume and less affected by their surroundings.

Simulation for Chlorine Residuals and Effect of Rechlorination in Drinking Water Distribution Systems of Suwon City (수원시 상수관망에서 잔류염소와 재염소주입의 효과 예측)

  • Kim, Kyung-Rok;Lee, Byong-Hi;Yoo, Ho Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.108-116
    • /
    • 2000
  • Chlorine is widely used as a disinfectant in drinking-water systems throughout the world. Chlorine residual was used as an indicator for prediction of water quality in water distribution systems. The variation of chlorine residual in drinking water distribution systems of Suwon city was simulated using EPANET. EPANET is a computerized simulation model which predicts the dynamic hydraulic and water quality behavior within a water distribution system operating over an extended time period. Sampling and analysis were performed to calibrated the computer model in 1999 (Aug. Summer). Water quality variables used in simulations are temperature, roughness coefficient, pipe diameter, pipe length, water demand, velocity and so on. Extended water residence time affected water quality due to the extended reaction time in some areas. All area showed the higher concentration of chlorine residual than 0.2mg/l(standard). So it can be concluded that any area in Suwon city is not in biological regrowth problem. Rechlorination turned out to be an useful method for uniform concentration of free chlorine residual in distribution system. The cost of disinfectant could be saved remarkably by cutting down the initial chlorine concentration to the level which guarantees minimum concentration (0.2mg/l) throughout the distribution system.

  • PDF

Dewatering Characteristic of Water Treatment Plant Sludges based on Detention Time (체류시간에 따른 정수장슬러지의 탈수특성)

  • Moon, Yong-taik;Kim, Byung-goon;Kim, Youn-kwon;Kim, Hong-suck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.709-715
    • /
    • 2007
  • The dewaterability of a sludge can be characterized by two ways: the residual moisture content in the sludge cake after dewatering process, and the filtration of the sludge. Time to filter (TTF) represents filtration processes that are special cases of the flow through a solid matrix concept. TTF characterizes a resistance to filtration. The sludge resistance, in turn, can be subdivided into resistances associated with the solid phase and the liquid phase to evaluate the effect of each of the two phases on sludge dewaterability. In order to determine the dewatering characteristics of the water sludge samples, TTF and zeta potential were measured. For these studies cationic polymer was chosen for water sludge dewatering experiments. The zeta potential of thickener sludges neared from minus values to zero values till 4 days after sampling. The dewaterability of thickener sludges using cationic polymer was deteriorated according to the increase of detention time. As the detention time was increased from 4 to 10 days, the optimal dose of the polymer was increased from 4 to 8mg/L. Therefore, the optimal detention time plays an important part for the dewaterability of a sludge.

Risk Evaluation of Tree Root Intrusion into Sewer Network (하수관망의 나무뿌리 침입 리스크 평가)

  • Han, Sangjong;Shin, Hyunjun;Hwang, Hwankook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.6
    • /
    • pp.693-702
    • /
    • 2015
  • The objective of this study is to investigate and evaluate that a roadside tree root intrudes sewer network systems. Two approaches were performed to assess the characteristics of tree root intrusion. First, the characteristics of tree roots that had invaded sewers were directly observed by means of closed-circuit television inspection robot. Second, the intrusion proportions of tree root into rain gutters in the sampling area were investigated. As tree species of low intrusion proportions, the results indicated that Ginkgo biloba Linn. and Acer buergerianum Miq. were 1.7% and 4.3%. On the other hand, tree species of high intrusion proportions were Metasequoia glyptostroboides Hu et Cheng, Ulmus davidiana var. japonica Nakai and Zelkova serrata Makino as 22.2%, 20.4%, and 17.6% respectively. In particular, sewers and gutters around Zelkova species should be the focus of maintenance work because of the high proportion of these trees on roadsides.

Estimating willingness-to-pay for the tap water quality improvement in Busan using contingent valuation method (조건부가치측정법을 이용한 부산시 상수도 수질개선에 대한 WTP 추정)

  • Pyo, Heedong;Choo, Jae Wook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.561-571
    • /
    • 2014
  • The paper is to estimate willingness-to-pay (WTP) for tap water quality improvement in Busan, using parametric approach in contingent valuation method(CVM). For parametric approach linear logit model and log logit model are employed in double-bounded dichotomous choice format of CVM. For the reliability and the validity of contingent valuation method a survey was conducted for 665 respondents, who were sampled by stratified random sampling method, by personal interview method. The result of mean WTP for the tap water quality improvement in Busan was estimated to be 3,687 won and 3,660 won per month per household, while median WTP being 1,884 won and 1,892 won per month per household, respectively by linear logit model and log logit model. Provided that our sample is broadly representative of the Busan's population, an estimate of the annual aggregated benefit of residential water improvement for all Busan households is approximately 29.7 billion won to 29.8 billion won based on median WTP.

Water Quality Modeling for Intake Station by 2-dimensional Advection-Dispersion Model (2차원 이송-확산 모형을 이용한 취수장 유입 수질 예측)

  • Kim, Jae-Dong;Kim, Ji-Hoon;Kim, Young-Do;Song, Chang-Geun;Seo, Il-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.667-679
    • /
    • 2011
  • In this study, the influences of pollutant from Dae-po Stream and So-gam Stream located at the downstream of Nak-dong River on the water quality at Mul-geum water intake station were analyzed using RAMS model. Field measurements of velocity by ADCP, and water quality distribution of BOD and TP by water sampling were carried out to present the input and verification data for numerical simulations. The comparison between RAM2 and ADCP measurement, which aimed for the analysis of 2-D velocity distribution around Mul-geum water intake station showed that two results matched well along the spanwise direction. The prediction of pollutant concentration by RAM4 agreed fairly well with the measured data except for the points nearby right banks in the vicinity of tributary pollutant source. Flushing effect by the increase of mainstream discharge in Nak-dong River was analyzed to provide the damage mitigation in preparation for the accidental water pollution. With increasing mainstream discharge, high velocity and increased water quantity induced increasing dilution effect, thereby decreasing the inflow pollutant concentration rapidly.

Site Evaluation of Automated Monitoring Networks in Han River (한강수계 수질오염 자동측정망의 합리적인 측정지점 선정에 관한 조사연구)

  • Cho, Yong-Mo;Oh, Jung-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.4
    • /
    • pp.91-98
    • /
    • 1997
  • At present, automated monitoring of water quality in Han river has been operated at each water treatment plant. But the automated measurement sites must be choosen newly because water source in Seoul move to the upper stream of Chamshil weir. In this study, automated monitoring sites in Han river were reviewed, and the proper sites for automated monitoring of water quality have been selected by Qual2E model, RMA model, water sampling guidline, Sanders' method and topograpical characteristics of Han river in order to resonable operate. 8 sites have been selected as follows: (1) the site of immediately after Paldang drainage (2) the left site and a right site of $Gu{\check{u}}i$ water intake (3) the left site and a right site at Noryangjin(Han river bridge) (4) the site between Shingok weir and Anyangchun confluence point(Hangju bridge) (5) the site of Chungryangchun downstream(existence) (6) the site of Tanchun downstream(existence) (7) the site of Anyangchun downstream(existence) (8) the site of Wangsukchun downstream. The results proposed resonable operating management of network and economical system built up.

  • PDF