• 제목/요약/키워드: waste treatment facilities

검색결과 188건 처리시간 0.027초

폐기물 처리시설에 관한 소도시 시민의 의식 조사 (Citizen's Attitude to Treatment Facilities of Municipal Solid Waste in Small City)

  • 장성호;박진식
    • 환경위생공학
    • /
    • 제14권1호
    • /
    • pp.70-79
    • /
    • 1999
  • A questionary survey was conducted to investigate citizen's attitude to treatment facilities of municipal solid waste in Miryang during 8. June of 1998 and 22 June of 1988. Collection effiencies was 86.7%, as 260 individuals of the 300 individuals. The survey showed that 43.0% of answers recognized seriousness of problem of the waste treatment and 33.1% of respondents concerned about recycle of organic waste. 40.8% of total answers said that they most hated landfill site among waste treatment facilities, and most citizens wanted as much distant as possible from waste treatment facilities. It was investigated that the greater part of respondents wanted the greatest compensation. About 58% of respondents was opposed to complete waste treatment facilities. 36.2$ among answers wanted establishment of waste treatment facilities in an industrial complex or an industrial area. The majority of respondents was willing to increase recycle rate and recognized seriousness of landfill site security. The majority of citizens do not trust environmental administration of Miryang City and they think that democracy and open of administration need for overcome MINBY.

  • PDF

VOLATILE ORGANIC COMPOUNDS MEASUREMENT IN THE BOUNDARY OF WASTE TREATMENT FACILITIES

  • Yim, Bong-Been;Kim, Sun-Tae
    • Environmental Engineering Research
    • /
    • 제12권2호
    • /
    • pp.46-54
    • /
    • 2007
  • Concentrations of the principal volatile organic compounds, such as benzene, toluene, ethylbenzene, m,p,o-xylene, styrene, and chlorobenzene were measured at the solid waste treatment plants classified into four categories; municipal waste incinerator, municipal waste landfill site, industrial waste incinerator and industrial waste landfill site. The average concentration of VOCs in industrial waste treatment facilities was 33.43 ppb and was significantly higher than that measured at municipal waste treatment facilities (4.71 ppb). The average toluene concentrations measured at incinerators (13.05 ppb) were a little higher than those measured at landfill sites (11.54 ppb). The contribution of the waste treatment facilities to the concentration of benzene (0.35 ppb) and o-xylene (0.15 ppb) in the industrial area was relatively small. However, toluene measured in the industrial waste treatment facilities was the most abundant VOCs with the average concentration of 21.37 ppb. As a result of analyses of fingerprint, in cases of IISH and ILUS, a variety of compounds other than major VOCs were detected in high level. On the Pearson correlation analysis, the correlation was generally positive and some pairs of these VOCs were very strongly correlated (correlation coefficient > 0.75).

폐기물처리시설의 세부검사방법 마련연구(I): 공정별 주요인자 도출 및 물질·에너지수지 산정 (A study on inspection methods for waste treatment facilities(I): Derivation of impact factor and mass·energy balance in waste treatment facilities)

  • 이풀잎;권은혜;손준익;강준구;전태완;이동진
    • 유기물자원화
    • /
    • 제31권1호
    • /
    • pp.69-84
    • /
    • 2023
  • 폐기물처리시설의 지속적인 설치·정기검사에도 불구하고 현장 처리시설에서는 과다소각, 불법투기 악취 등에 대한 민원이 지속적으로 발생하는 것으로 보아 현재의 폐기물처리시설 설치정기 검사방법의 개선이 필요하다고 판단되었다 이에 현재 운영중인 폐기물처리시설(6개분야)을 대상으로 현장조사를 실시하여 각 분야별 폐기물처리공정을 파악하고 검사에 적용된 주요한 운영인자를 파악하고, 주요공정별 물질·에너지수지를 산정하여 폐기물처리시설의 적정 운영 여부를 확인하였다. 주요 운영인자 조사 결과 소각 및 시멘트 소성로, 소각열회수시설 등의 경우 소각에 필요한 소각로의 온도 유지 및 발생되는 대기오염물질의 처리가 가장 주요한 인자였으며, 매립시설의 경우 옹벽의 안정성, 매립 후 발생되는 침출수 및 배출가스 관리가 주요한 인자로 나타났다. 멸균·분쇄시설의 경우 멸균여부(아포균검사)가 가장 중요한 주요인자 이었으며, 음식물류폐기물처리시설의 경우 발효(소화, 부숙) 시 체류시간 및 악취관리가 주요한 인자로 나타났다. 또한 물질에너지수지 산정 결과 소각시설의 경우 폐기물 투입량 대비 바닥재 발생량은 약 14%, 비산재 발생량은 약 3%로 적정 운영되고 있을을 확인하였다. 또한 음식물류폐기물시설 중 혐기성분해시설의 경우 유입량 대비 바이오가스 발생량은 약 17%, 바이오가스 전환효율은 약 81%로 나타났고, 퇴비화시설의 경우 유입폐기물 대비 약 11%의 퇴비가 생산되어 모두 적정운영 되고있음을 확인하였다. 이에 따라 폐기물처리시설 검사방법의 고도화를 이루기 위해 세부검사방법의 정량적 기준 적립 뿐만 아니라 각 시설의 정기검사 시 1년간의 운영자료 등을 수집하여 폐기물의 흐름을 파악하고 처리시설의 적정운영 여부를 판단한다면, 처리시설의 운영 및 관리효율이 상승할 것으로 판단된다.

님비와 폐기물처리시설 설치 방향 (The Nimby Syndrome and Basic Plan for Waste Treatment Facilities in 1994)

  • 신현국
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.59-64
    • /
    • 1994
  • In order to democractically resolve the "not-in-my-backyard" (Nimby syndrome) which is widespread in Korea, the policy of the Ministry of Environmnt(MOE) is that the MOE is willing to negotiate with local inhabitants who refuse to allow the establishment of waste treatment facilities, and that such facilities will be safety and effectively constructed and managed. According to this policy, the MOE has developed a basic plan to construct 255 incinerators by the year 2001, and establish 42 sanitary landfill sites and 5 specific waste treatment facilities in 1994.s in 1994.

  • PDF

음식물류폐기물 공공 자원화시설의 운영실태 조사를 통한 처리공정별 효율적인 운영방안 검토 (Investigation on the operational state of the public food waste treatment facilities and suggestions on their efficient operational management)

  • 장윤혁;박준석;김정대;배재근
    • 유기물자원화
    • /
    • 제18권1호
    • /
    • pp.47-56
    • /
    • 2010
  • 현재 전국에는 255개의 음식물류 폐기물 자원화시설이 공공시설(95개소) 및 민간시설(160개소)에 의하여 운영되고 있으며, 이들 시설들은 97년도부터 지속적으로 설치되고 있다. 정부에서는 설치 및 운영에 관한 지침과 설치검사기준 등을 정하여 시행하고 있으나, 시설 설치 절차에 따른 세부적인 검토사항, 설계, 공정기준 등이 명확하지 않아 운영관리 체계 미흡, 처리효율 저하, 시설 하자 등이 문제점이 발생되고 있다. 따라서, 본 연구에서는 이들 문제점을 최소화하기 위한 시설 운영방안을 제시하기 위해 음식물 공공자원화시설 95개소를 대상으로 설문 및 현장방문조사를 실시하였다. 조사결과 전처리시설에서는 2계열 및 호퍼덮개 미설치, 음식물 과적 및 이송 물량 과다, 주처리시설은 운전미숙으로 인한 2차 환경오염발생, 과다 음식물투입으로 시설효율 저하, 시설운영상 부적합한 운전관리 기준 등이 문제점으로 조사되었다. 악취 및 음폐수(음식물류폐기물 처리과정 중 발생 폐수) 처리시설에서는 운영미숙, 주기적인 점검 부족, 처리시설 용량 부적절 등이 문제점으로 조사되었다. 이와 같이 조사되어진 문제점을 근거로 하여 효율적인 운영방안을 제시하였으며, 향후 음식물류 폐기물 자원화시설을 설치 및 운영하는데 있어 처리효율 제고, 시행착오 및 하자를 최소화할 수 있을 것으로 판단된다.

환경기초시설별 주민지원금 산정방안 - 강원도 중심으로 - (Estimation of Resident Support Fund Regarding Types of Environmental Foundational Facilities - Focus on Gangwon Provincial Government -)

  • 최용범;이해승
    • 대한환경공학회지
    • /
    • 제28권9호
    • /
    • pp.905-910
    • /
    • 2006
  • 본 연구는 강원도의 환경기초시설 설치에 따른 주민지원금의 현황을 파악하고 처리형태에 따른 합리적인 주민지원금을 산정하기 위하여 수행되었다. 강원도에 지원된 주민지원금은 환경기초시설 설치비용에 $1.6{\sim}75.0%$로 과도하게 지원된 것으로 조사되었다. 합리적 주민지원금 산정방안은 평균 인구분포, 주민지원금 지원현황, 법적기준 및 전문가 설문조사 결과를 적용하여 수행하였다. 본 연구에서 산정한 처리형태별 주민지원금 범위는 폐기물 처리시설은 설치비용의 20% 범위, 음식물류 폐기물처리시설은 10% 범위, 하수 분뇨합병처리시설은 $3{\sim}5%$ 범위로 산정되었다.

폐기물 처리시설에서의 악취 및 환기에 관한 연구 (A study on odor and ventilation in waste treatment facilities)

  • 서병석;전용한
    • Design & Manufacturing
    • /
    • 제14권2호
    • /
    • pp.28-33
    • /
    • 2020
  • Recently, as the income level and quality of life have improved, the desire for a pleasant environment has increased, and a deodorization plan is required through thorough prevention and diffusion of odorous substances in waste treatment facilities recognized as hateful facilities, appropriate collection, and selection of the right prevention facilities. In this study, a waste disposal facility was modeled and computerized analysis for odor and ventilation analysis was conducted. Numerical analysis of the waste treatment facility was performed at the size of the actual plant. CATIA V5 R16 for numerical model generation and ANSYS FLUENT V.13 for general purpose flow analysis were used as analysis tools. The average air-age of the internal was 329 seconds, and the air-flow velocity was 0.384m/s. The odor diffusion analysis inside the underground pump room showed congestion-free air circulation through streamline distribution and air-age distribution. This satisfies the ASHRAE criteria. In addition, the results of diffusion analysis of odorous substances such as ammonia, hydrogen sulfide, methyl mercaptan and dimethyl sulfide were all expected to satisfy the regulatory standards. Particularly in the case of the waste loading area, the air-flow velocity was 0.297m/s, and the result of meeting the regulatory standards with 0.167ppm of ammonia, 0.00548ppm of hydrogen sulfide, 0.003ppm of methyl mercaptan, and 0.003ppm of dimethyl sulfide was found.

부산지역 환경기초시설에서 발생하는 폐기물의 물리, 화학적 특성 규명 및 황화수소 발생량 예측에 관한 연구 (Physicochemical Characteristics and Estimation of H2S Emission Rate from Municipal Solid Waste at the Environmental Facilities in Busan City)

  • 이태윤;김도용;김재진;이준기
    • 한국지반환경공학회 논문집
    • /
    • 제10권2호
    • /
    • pp.13-20
    • /
    • 2009
  • 최근 우리나라의 국민들의 삶의 질이 향상됨에 따라 악취발생문제가 중요한 사회이슈가 되고 있다. 특히 환경기초시설에서 발생하는 악취물질로 인한 민원 중 약 67%가 하수처리장과 음식물쓰레기 처리시설에 의한 것으로 나타났으며, 해양오염방지법 시행규칙개정으로 2012년부터는 하수오니 등의 해양투기가 전면 금지될 예정에 있어 이들 시설의 처리량 증가에 따른 관리대책마련이 시급한 실정이다. 따라서 본 연구에서는 부산시 전역의 하수처리장과 음식물쓰레기처리시설중 상대적으로 폐기물발생량이 많은 5개 하수처리장과 5개 음식물쓰레기처리시설을 선정하여 슬러지 시료를 채집하고 이들 시료에 대한 공업분석, 원소분석, XRF 분석, 발열량분석 등을 통해 시료의 물리, 화학적 특성을 알아내었다. 또한 최종적으로 시료 내 황화수소 발생가능농도 측정을 통해 황화수소발생원단위를 산정, 악취민원의 근본적 대책마련을 위한 기초 자료로써 활용 하고자 하였다. 분석결과, 하수슬러지의 황화수소농도는 평균 57.3mg/kg, 음식물쓰레기처리시설의 것은 19.7mg/kg이었다. 최종적으로 총 10개 시설 폐기물의 황화수소 발생원 단위 산정결과 16,017,910.0mg/d로 예측 되었다.

  • PDF

폐 FRP 선박 처리시설 입지선정문제 (Location Problem on the Treatment Facility of Waste FRP Ships)

  • 박현지;신재훈;김기동
    • 산업기술연구
    • /
    • 제38권1호
    • /
    • pp.9-13
    • /
    • 2018
  • FRP(Fiber Reinforced Plastic) ships are easy to manufacture and repair. Also they are more durable and cheaper than steel wires and neck lines. Therefore FRP ships are widely used in small ships. In Korea, the amount of waste FRP ships is increasing. It is expected that a large amount of waste FRP ships will be generated. Waste FRP ships are emerging as a social problem, such as the difficulty in preserving the marine environment. To improve this, a waste FRP ship melting process system has been developed. In order to construct an effective waste FRP ship processing system, it is necessary to study the treatment facilities location problem. In this paper, we suggest mathematical model to solve optimal location problem of waste FRP Ships and discuss on results by applying it to nine regions selected as candidates for treatment facilities.

산업용제조시설과 폐기물처리시설에서 발생된 나노폐기물의 물리화학적 특성 및 안전관리방안 제시 (Suggestion of Physicochemical Characteristics and Safety Management in the Waste Containing Nanomaterials from Engineered Nano-materials Manufacturing Plants and Waste Treatment Facilities)

  • 김우일;연진모;조나현;김용준;엄남일;김기헌;이영기
    • 한국폐기물자원순환학회지
    • /
    • 제35권7호
    • /
    • pp.670-682
    • /
    • 2018
  • Engineered nanomaterials (ENMs) can be released to humans and the environment through the generation of waste containing engineered nanomaterials (WCNMs) and the use and disposal of nano-products. Nanoparticles can also be introduced intentionally or unintentionally into waste streams. This study examined WCNMs in domestic industries, and target nanomaterials, such as silicon dioxide, titanium oxide, zinc oxide, nano silver, and carbon nanotubes (CNTs), were selected. We tested 48 samples, such as dust, sludge, ash, and by-products from manufacturing facilities and waste treatment facilities. We analyzed leaching and content concentrations for heavy metals and hazardous constituents of the waste. Chemical compositions were also measured by XRD and XRF, and the unique properties of nano-waste were identified by using a particle size distribution analyzer and TEM. The dust and sludge generated from manufacturing facilities and the use of nanomaterials showed higher concentrations of metals such as lead, arsenic, chromium, barium, and zinc. Oiled cloths from facilities using nano silver revealed high concentrations of copper, and the leaching concentrations of copper and lead in fly ash were higher than those in bottom ash. In XRF measurements at the facilities, we detected compounds such as silicon dioxide, sulfur trioxide, calcium oxide, titanium dioxide, and zinc oxide. We found several chemicals such as calcium oxide and silicon dioxide in the bottom ash of waste incinerators.