• Title/Summary/Keyword: waste landfill liner

Search Result 68, Processing Time 0.027 seconds

Design Forces Acting on Geosynthetics in Landfills (매립장 사면에 설치된 토목섬유의 설계 인장강도 산정)

  • 정문경;김강석;우제윤;류찬희
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.407-414
    • /
    • 2000
  • This paper presents measured deformation of geomembrane installed on slopes of a landfill. The layout of geosynthetics installed on landfill slopes as required by regulations is composed of, in typical, geocomposite, geomembrane, geosynthetic clay liner in turn from the slope. An effort was made to better understand the sources of external forces acting on geosynthetics and their interactions. The results of a field observation indicated that tensile stresses induced on geomebrane were far less in magnitude than predicted by the design method employing mass equilibrium of waste. This was mainly because external forces acting on slopes were not transferred from geocomposite to underlying geomembrane. A simple, but rather rational method for assessing the stability of geosynthetics against tensile stresses was proposed. This method is based on a hypothesis that external forces acting on geosynthetics are the results of downdrag of waste during waste compaction.

  • PDF

Stress-Strain of Geomembranes In Landfill Under Punctiform Loads (폐기물매립장 차수재의 꿰뚫림 하중에 의한 응력-변형)

  • 이광열;정진교
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.06a
    • /
    • pp.55-65
    • /
    • 2001
  • Geotextiles are usually constructed as a protective layer of geomembranes in liner systems for the solid waste landfill. A protective layer and geomembrane are susceptible to mechanical damage by coarse grains in the overlying drainage layer. In this study, therefore, the strain behavior of geotextile protective layers was investigated using three different types of devices for developing punctiform loads. The results of the study showed that the rates of strain was different depend upon device types for functiform loads. Also, It was found that the increases in strain was approximately linear in range 20 to 6$0^{\circ}C$ , and pp-filament non-woven geotextiles yielded a better efficiency than pp-staple fiber non-woven geotextiles.

  • PDF

Stress-strain Behavior of Hardened Barrier on Soft Soil (연약지반 위에 포설된 고화차수재의 응력-변형 특성)

  • 장연수;이종호;임학수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.607-614
    • /
    • 2000
  • Settlement with crack on the hardened liners may occur in the weak clay due to waste load since the stiffness of the hardened liner is greater than that of the clay layers. Way of reducing deformation crack in the hardened liner is investigated using two computer programs, CONSOL and FLAC. The computer program CONSOL estimates the magnitude of settlement with time in clay layers and FLAC analyses the stress and deformation relationship between the foundation of landfill and waste load. The results show that a representative block of the analyzed area reaches the consolidation settlement of 1.32m, 8.8 years after the disposal of waste started with the degree of consolidation U=90%. The stress within the hardened liner exceeds the allowable vertical stress of 5kg/$\textrm{cm}^2$ and horizontal stress of 1.67kg/$\textrm{cm}^2$ at the concave part of the liner where the main and branch drainage pipes of leachate are located. It was recognized that the thickness of the interested area should be enlarged or the strength of the same area should be improved to tolerate the planned waste load.

  • PDF

Case Study of Remidation and Investigation of Closed Unsanitary Landfill for Prevention of Leachate (비위생매립지 정밀조사 및 침출수 방지를 위한 정비방안 연구)

  • Kim, Sangkeun;Lee, Yongsoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.5-13
    • /
    • 2012
  • For the last decade the amount of waste has rapidly been increased in South Korea and many waste landfills have been built according to government guidelines specifying required systems such as landfill liner, leachate collecting facilities, final cover system, etc. This effort has led the recently constructed landfills to be under well managed sanitary condition. In a meanwhile closed waste-landfill sites in the past before the adoption of the government guidelines exits under unsanitary condition. In these cases untreated leachate flew out to the surroundings due to the absence of liner and leachate collecting facilities and caused groundwater and soils to be contaminated. Waste generated odor and gas also brought civil complaints. Because environmental influences bring serious problems nearby sites, it is required to have unsanitary waste-landfills to be appropriately treated and managed. A study to evaluate environmental influence and contamination level of surroundings nearby and on the unsanitary landfills is necessary before the establishment of "Management guide of closed landfill site." This paper presents an environmental evaluation for the closed site, Doil-dong landfill, according to "Closed landfill management regulation" by Ministry of Environment. "D" landfill, located in Pyeongtaek city, has possobility to contaminate surrounding surfacewater and groundwater by leakage of leachate. The in-situ stabilization carried out to build the DMW(deep soil mixing cutoff wall) wall and drainage systems.

Applicability of Industrial Waste Management Evaluation Model (IWEM) in Korea (지하수 오염방지를 위한 산업폐기물 관리평가 모델(IWEM)의 국내 적용성 분석)

  • Park, Dong-Won;Woo, Nam-C.;Chung, David
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Selection of appropriate liner type would be the most important factor to prevent groundwater contamination by leachate from waste management site. This report introduces the IWEM (Industrial Waste Management Evaluation Model) developed by US EPA to evaluate the potential pollution of groundwater under the waste management unit and to suggest an appropriate type of liner, and provides with the results of IWEM application to a coal-ash landfill site in Korea as a case study. IWEM uses a standard method using a database, a decision-making process based on site characteristics, and the user-friendly input-and-output system. Authors evaluate this model to be applicable in Korea provided that the database is replaced into local data.

Permeability and strength characteristics of Self-Sealing and Self-Beating materials as landfill liners (매립지 차수재로서 자가치유재의 투수 및 강도특성)

  • 장연수;문준석
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.41-51
    • /
    • 2002
  • Recently, domestic waste landfills are constructed sometimes on seashore area to provide large landfill area. In order to strengthen the foundation of landfills and to prevent the infiltration of leachate through the bottom, many cases of constructing cement hardened liners on seashore clays are found. In these cases, it is possible to have cracks in the hardened liners due to settlement with waste load since the stiffness of the hardened liner Is greater than that of clay liners. In this study, the capability of Self-Sealing and Self-Healing (SSSH) liner made with a seashore clay in the metropolitan landfill to prevent the percolation of water and leachate is examined using flexible-wall permeameter test and using uniaxial compression test. Applicability of SSSH to weathered granitic soil is also examined for self-sealing capabilities. The result of Flexible permeameter test for SSSH with the seashore clay showed that permeability obtained was lower than permeability criteria of Korean waste management law. The permeability and strength characteristics of SSSH with granitic soil and bentonite showed better results than with the seashore clay.

Permeability of Soil-Bentonite Mixtures (흙-벤토나이트 혼합물의 투수특성)

  • 채교익;권무남;이상호;남효석
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.1
    • /
    • pp.55-62
    • /
    • 2003
  • Leachate generated from landfill material flows through soil gravitationally downward and. continues to flow until it encounters groundwater, posing the thread of pollution. So selection of liner material having a low permeability and testing method are required. The study was performed to find bentonite content of soil-bentonite mixtures for using as liner and cover of waste landfills. This paper includes results of consolidation tests and permeability tests and evaluates suitability and properties of soil-bentonite mixtures as impervious materials.

Stability Analysis of Waste Landfill Using Multi-interface Element Numerical Method (복합 경계면요소 수치해석에 의한 매립지 안정성 해석)

  • 장연수;김홍석
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.4
    • /
    • pp.29-38
    • /
    • 2004
  • A finite element nonlinear stress-deformation model with multi-interface element is applied to the stability analysis of waste landfill slope. Strength parameters of waste and geosynthetic materials are obtained from the triaxial test of waste and the direct shear test of geosynthetics, respectively. The landfill models used for the numerical models are fit to regulations of the Korean waste management law. The results of the strength tests showed linear behavior for the waste and nonlinear behavior for the eosynthectic materials. The stability analysis with multi-interface element for the geosynthetic materials in the liner system showed large shear stress and slippage at the boundary of the foundation and the slope of the waste fill. This analysis verified the necessity of multi-interface analysis for waste landfills with composite liners.

Development of new electrical leakage detection system for waste landfil (위생매립지 누출검지 및 누출위치 파악을 위한 전극배치시스템 개발)

  • Han, Sang-Jae;Shin, Hyun-Young;Jung, Jae-Hyun;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.242-250
    • /
    • 2008
  • Lining systems are used for two purpose in landfills : as covers to minimize leachate generation and surface water contamination by providing a barrier from precipitation and other percolating waters, and as containment liners to contain leachate and minimize its downward migration into underlying groundwater. So identifying leaks in landfill liners is an essential part of waste management. There are many leakage detection systems to monitor and seek leakage location, such as two electrode method, electrode grid method, diffusion hoses, capacitance sensors and tracers sensing cables. However, most of them can be applied in the new landfill construction sites because sensors must be installed prior to work. This paper presents a new type of leakage detection system, so called fence type electrode arrangement system, to monitor leakage and to seek leakage location in working landfill as well as new landfill. This system is based on the measurement of an electrical current flowing through leakage point. Series of laboratory tests are performed to investigate an availability of this system and this paper present some of these results.

  • PDF

A Comparative Study on the Feasibility of Geosynthetics Clay Liner and Compacted Mixing Material Using By-products from Sewage Sludge to the Final Cover Materials in Landfills (하수 슬러지 부산물을 이용한 다짐혼합재 및 토목합성수지점토라이너의 최종복토 차단층재로의 적용성에 관한 비교연구)

  • Jeong, Ji-Hoon;Lee, Jai-Young;Lee, Myung-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.2
    • /
    • pp.49-52
    • /
    • 2008
  • Most of waste sludge has generally been disposed in landfill site or dumped in the ocean, which will be banned by the content of its heavy metals according to London Dumping Convention in Korea. Therefore, environmentally friend methods are urgently required for the treatment and disposal of the sewage sludge. Thermal hydrolysis is one of the good treatment methods to solve the sludge problems. In this study, the physical and environmental testing was conducted to evaluate the feasibility of by-product cake from the thermal hydrolysis as liner or cover materials in landfill.

  • PDF