• Title/Summary/Keyword: washing-system

Search Result 488, Processing Time 0.026 seconds

Development of High Performance Low Pressure Carburizing System (Batch type 가스침탄 열처리로 국산화개발)

  • Kim, Won-Bae;Dong, Sang-Keun;Jang, Byoung-Lok;Han, Hyoung-Ki;Kim, Han-Suck;Cho, Han-Chang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.19 no.5
    • /
    • pp.262-269
    • /
    • 2006
  • The development of eco-friendly low pressure carburizing system with high pressure gas quenching(LPC-GQ, 500kg/charge) led to new stage in the fundamental case-hardening treatments. This is due to its ability to provide tighter tolerances on the carburizing process with notable reductions in distortion of the carburized and hardened workpiece. This system is characteristics by high uniformity and reproducibility of heat treatment results, absence of an intergranular oxidation layer, carburizing of complex shapes, reduced cycle time, low operating costs, simplified production, eliminate post washing, and reduced grinding costs.

Internet of Things based Smart Energy Management for Smart Home

  • TASTAN, Mehmet
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.6
    • /
    • pp.2781-2798
    • /
    • 2019
  • Thanks to internet, as one of indispensable parts of our lives, many devices that we use in our daily lives like TV, air conditioner, refrigerator, washing machine, can be monitored and controlled remotely by becoming more intelligent via Internet of Things (IoT) technology. Smart Home applications as one of the elements of smart cities, are individually the most demanded application without question. In this study, Smart Energy Management (SEM) system, based on NodeMCU and Android, has been designed for SEM, which is a part of the smart home application. With this system, household energy consumption can be monitored in real time, as well as having the ability to record the data comprising of operation times and energy consumption information for each device. Additionally, it is ensured to meet the energy needs on a maximized level possible, during the hours when the energy costs are lower owing to the SEM system. The Android interface provides the users with the opportunity to monitor and change their electricity consumption habits in order to optimize the energy efficiency, along with the opportunity to draw up of a daily and weekly schedule.

Assessment of Field Applicability of a Zero Discharge and Reuse System (무방류 재이용 시스템 현장 적용성 평가)

  • Cho, Kyung-Sook;Lee, Kwang-Ya
    • Current Research on Agriculture and Life Sciences
    • /
    • v.29
    • /
    • pp.75-81
    • /
    • 2011
  • This study performed field examinations of a zero discharge and reuse system developed by Hong and Choi(2009). The system installed one of villages located in Hyoryeong-myeon, Gunwee-gun for the experiments. The zero discharge and reuse system consists of anoxic, FES (Ferrous Electricity System), Oxic, Cralifier processes for water treatments. The main feature of the system is to remove phosphorous by using Fe-ionizing module within the FES process. The water purification performances of the system were evaluated, while any defects for using the system were investigated through the field monitoring. It was found that the removal capacities of T-P, T-N, and BOD of the system meet the required water quality with outstanding performance from T-P by obtaining the results of over 90 % removal rates. The efficiency of T-P removal rate of the system found to be greatly influenced by whether using an automatic washing system to the Fe-ionizing module and conducting replacement of iron plate within a proper period.

  • PDF

Design of Irrigation Pumping System Controller for Operational Instrument of Articulation (관절경 수술을 위한 관주(灌注)시스 (Irrigation Pumping System) 제어기의 개발)

  • 김민수;이순걸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1294-1297
    • /
    • 2003
  • With the development of medical field, many kinds of operations have been performed on human articulation. Arthroscopic surgery, which has Irrigation Pumping System for security of operator vision and washing spaces of operation, has been used for more merits than others. In this paper, it is presented that the research on a reliable control algorithm of the pumping system instrument for arthroscopic surgery. Before clinical operation, the flexible artificial articulation model is used for realizing the model the most same as human's and the algorithm has been exploited for it. This system is considered of the following; limited sensing point, dynamic effect by compliance, time delay by fluid flow and so on. The system is composed with a pressure controller, a regulator for keeping air pressure, an airtight tank that can have distilled water packs, artificial articulation and a measuring system, and has controlled by the feedback of pressure sensor on the artificial articulation. Also the system has applied to Smith Predictor for time delay and the parameter estimation method for the most suitable system with both the experiment data and modeling. In this paper, the pressure error that is between an air pressure tank and an artificial articulation was measured so that the system could be presumed and then the controller had developed for performing State-Feedback. Finally, the controller with a real microprocessor has realized. The confidence of system can be proved by applying this control algorithm to an artificial articulation experiment material.

  • PDF

Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (I) - Development of the FDA System - (시설용수 및 영농편의용수 공급시스템 개발 (I) - FDA 시스템 개발 -)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.95-100
    • /
    • 2009
  • The water purification systems have been hardly used for agricultural purpose due to their complicated compositions and high costs for farmers, while only simple filtrations have been applied to irrigation systems in order to prevent the system from clogging problems. This study therefore developed a clean water supplying system, the Filter-Disinfection-Adsorption (FDA) system, especially for greenhouse cultivation of where low quality of water is available. This system has also been produced for providing convenience water to farmers in the areas of no water supply service systems for the purpose of washing their bodies or agricultural machineries after farm work. The FDA system consists of three stages of purification processes with an integral module, including disk and teflon filtrations and Ultraviolet (UV) sterilization processes. Indoor experiments were undertaken with a trial product of the FDA system to test its performance. The operation test of the process was performed as well as the condition check of each item including UV module, filters, control panel, pump, valves, etc. The results shows good performance of each test with no critical problems. The initial and maintenance costs were also analysed with other purification systems. From the comparisons, the FDA system found to be very economical and easy to use.

Perception of the HACCP system operators on livestock product manufacturers

  • Kim, Jung-Hyun;Nam, Ki-Chang;Jo, Cheorun;Lim, Dong-Gyun
    • Journal of Animal Science and Technology
    • /
    • v.56 no.5
    • /
    • pp.19.1-19.6
    • /
    • 2014
  • The purpose of this study was to investigate crucial factors on HACCP system implementation in domestic livestock product plants, and to offer job satisfaction and the career prospect of HACCP system operators. The survey was carried out by selecting 150 HACCP system operators who implemented HACCP system. The respondents claimed that the most important contents in HACCP system operation were to assemble HACCP team (21.8%), and the second was to monitoring (20.0%). Documentation and recording (16.9%) and verification (11.1%) were followed. The respondents answered the major factor in sanitation management was cleaning/washing/disinfection (18.9%) and inspection (18.4%). The results showed that there were significant differences in the prospect of occupation in HACCP system operator by the gender (p < 0.015), age, livestock product facilities, service period, and position (p < 0.001). The respondents from HACCP system operator were satisfied with their job (73%) and also showed optimistic prospect of occupation (82%).

Development of Heat Pump Use Slurry Pig Manure Evaporation Drying System (열펌프를 이용한 슬러리 돈분뇨 증발건조처리시스템 개발)

  • Kim H. T.;Choi H. L.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.32-37
    • /
    • 2005
  • This study was conducted the slurry pig manure treatment by condensation drying of liquid from the slurry manure with a heat-pump and electric heater combined with air flow channel system. The system was designed as liquid and solid matters separation of slurry manure, and it can doing continuous input of slurry manure from a pig house, and it can operated year round use for pig farms. The separation of liquid and solid matters from slurry manure needed the prevention of solid accumulation in the system. The system was designed as closed space from outside air space for maximized evaporation of liquid and the condensation of liquid from slurry manure. The system can be operated the pig slurry manure treatment regardless of seasons in a yew. The separated evaporation water from the pig slurry manure by the heat-pump was satisfactorily pure water that can be used as washing water in livestock farms. The system can applicate to about 100 heads of pig, and the proper area of evaporation plate system was considered around $10\;m^2$. The input electrical energy of about 15 kWh which the cost equal to 250,000 won per month.

The School Foodservice Securement Facilities and Perceptions of Barriers to Implementation of HACCP System in School Foodservice in Seoul Area (서울지역 학교급식 시설 현황 및 HACCP 시스템 운영에 따른 장애요인 인지도 조사)

  • Lee, Ae-Rang
    • The Korean Journal of Food And Nutrition
    • /
    • v.26 no.3
    • /
    • pp.578-590
    • /
    • 2013
  • The subject study was targeted towards nutrition teacher (dietitian) of elementary, middle, and high schools in Seoul areal. In addition, this study was to investigate the current status of school foodservice securement facilities & equipments and to analyze the obstructive factors for executing the HACCP system. The aim of this study was to provide base-line data so that a more efficient & effective sanitary management system for school foodservise can be settled in. All surveys were distributed and collected via email. A total of 305 survey papers were collected and out of these, 300 school results were analyzed and the results are as follows. The order of the securement facilities & equipment furnished were pre-handing equipments>washing>cooking>inspection>facilities>storage>space area>distribution equipments. The awareness of obstructive factors in executing the HACCP system was a total of 3.17 points and the order was as follows. The general obstructive factors>obstructive factors in the cooking staff executing the HACCP system>collaboration between the school/team leaders and the budget supporting department>obstructive factors in the nutrition teacher (dietitian) executing the HACCP system. School foodservice securement facilities & equipments in Seoul area must be renovated and modernized so as to improve its current situation. Furthermore, leadership programs are necessary to enhance nutritionists' understanding of the HACCP system and the cooking staff's competencies in instructing and supervising.

Microbiological Safety Assessment of a Perilla Leaf Postharvest Facility for Application of a Good Agricultural Practices (GAP) System (농산물우수관리제도(GAP system) 적용을 위한 깻잎의 수확 후 관리시설(APC)에 대한 미생물학적 안전성 평가)

  • Kim, Kyeong-Yeol;Nam, Min-Ji;Lee, Hyo-Won;Shim, Won-Bo;Yoon, Yo-Han;Kim, Se-Ri;Kim, Doo-Ho;Ryu, Jae-Gee;Hong, Moo-Ki;You, Oh-Jong;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.4
    • /
    • pp.392-398
    • /
    • 2009
  • This study identified risk factors of cross-contamination of foodborne pathogens and established a good agricultural practice (GAP) system for an agricultural products processing center (APC) for perilla leaves. All samples were collected before and after a standard work shift at the APC, while perilla leaves were also collected after each step in the APC. In addition, the workers and their surroundings were sampled by swabbing. The total plate count (TPC) and coliform count in the water samples increased significantly (p<0.05) to 3.36 and 1.73 log CFU/mL after work, respectively. However, no Escherichia coli and Listeria monocytogenes were detected. The bacterial populations of the workers and their surroundings did not differ significantly (p${\geq}$0.05) before and after work. However, Staphylococcus aureus (<1.66 log CFU) was detected at a high rate (13-50%) in the basket, packing table, gloves and cloth. Although perilla leaves passed through the washing steps, the TPC and coliform bacterial populations on the final products were higher (p${\geq}$0.05) than those of unwashed perilla leaves, which indicates that the washing system was not functioning properly. Accordingly, a GAP system with a better washing system should be employed at this facility.

Implementation on the Portable Blood Gas Analyzer (휴대형 혈액가스 분석시스템의 구현)

  • Kang S.C.;Jeong D.U.;Bae J.W.;Shon J.M.;Shim Y.B.;Jeon G.R.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1032-1036
    • /
    • 2006
  • In this study, we implement the potable blood gas analyzer measuring pH, $pCO_2\;and\;pO_2$ of the arterial blood. The implemented system by this study is divided into hardware and software part and also the hardware portion is parted by mechanism and electronic circuit mit. The system program is composed of operating, washing, correcting and measuring program. And to correct the system, two-point calibration method is used, one-point calibration method is also added for more accuracy, and system program is coded. For verifying the implemented system, We examine to response property of each electrode. And evaluate accuracy of the system using standard reagent and was construed as statistical.

  • PDF