PDMS 기반 초소수성 마이크로 채널내의 유동 및 표면 젖음 전이 가시화에 관한 연구 (Visualization of Flow and Wetting Transition in PDMS Superhydrophobic Microchannel)

  • 김지훈;홍종인;변도영;고한서
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.671-674
    • /
    • 2008
  • We investigate the slippage effect in a micro-channel depending on the surface characteristics; hydrophilic, hydrophobic, and super-hydrophobic wettabilities. The micro-scale grooves are fabricated on the vertical wall to make the super-hydrophobic surfaces, which enable us visualize the flow fields near walls and directly measure the slip length. Velocity profiles are measured using micro-particle image velocimetry (Micro-PIV) and compared those in the hydrophilic glass, hydrophobic PDMS, and super-hydrophobic PDMS micro-channels. To directly measure the velocity in the super-hydrophobic micro-channel, the transverse groove structures are fabricated on the vertical wall in the micro-channel. The velocity profile near the wall shows larger slip length and, if the groove structure is high and wide, the liquid meniscus forms curves into the valley so that the wavy flow is created after the grooves.

  • PDF

수평관내 냉매의 과냉비등열전달에 관한 연구 (A Study on the Subcooled Boiling Heat Transfer in a Horizontal Tube)

  • 김종헌;김철환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권3호
    • /
    • pp.26-33
    • /
    • 1994
  • A new reliable method to prediet the axial vapor fraction distribution from the measured probability density of the liquid bulk temperature is suggested in this paper. And also the actual quality of the subcooled boiling flow is easily calculated from the liquid bulk temperature. When the heat generating rate is reached to the CHF value, the sharp wall temperature increasing by the wall temperature fluctuation is occurred under the CHF condition. This paper presents the simple wall temperature fluctuation model of transition boiling by the repeating process of overheating and quenching, when the coalescent bubble passes slowly near the wall. Experiments for the subcooled R-113 flow are carride-out in the range of(0.9399~4.461)${\times}10^6$kg/$m^2$hr mass velocity and 10~3$0^{\circ}C$ intel subcooling condition.

  • PDF

Assessment of Stability of Railway Abutment Using Geosynthetics

  • Kim, Ja-Yeon;Kim, Ji-Hwan;Cho, Kook-Hwan
    • International Journal of Railway
    • /
    • 제9권1호
    • /
    • pp.15-20
    • /
    • 2016
  • An approach section on an abutment is located between the soil embankment and the structure, which may cause an uneven surface due to different settlement between the abutment and the soil embankment. This study proposes a new type of wall which separates the abutment from the backfill material using mechanically stabilized wall. A new type of keystone which incorporates geotube and wire mesh is proposed and evaluated. Numerical analyses were performed to investigate the applicability of the proposed keystone type, which incorporates Geosynthetic. The maximum horizontal displacements along GRS wall faces, settlements at the top of pavement and track bed, and tensile forces applied on geotextiles under traffic loads were investigated. The results of the numerical analysis showed that the proposed wall can be used for highway and high-speed railway abutment.

표면 젖음성이 스프레드-스플래시 영역 간 천이 조건에 미치는 효과 (Surface Wetting Effect on Spread-Splash Transition Criterion)

  • 류성욱;이상용
    • 한국분무공학회지
    • /
    • 제12권4호
    • /
    • pp.198-203
    • /
    • 2007
  • In the present work, surface wetting effect on spread-splash regime and transition criterion of the water and ethanol droplets impacting an unheated dry wall has been experimentally investigated. The droplet was directed on a polished STS plate and a glass slide, and the impinging behavior was visualized and recorded using a CCD camera. Droplet diameter and velocity approaching the wall were measured as well. The critical Sommerfeld number representing the spread-splash boundary for the ethanol droplet impinging on the substrates turned out to be smaller compared to that for the water droplet impinging on the substrates with the surface roughness condition remained unchanged. The shift of the transition boundary is considered to be due to the effect of the surface wettability represented by static contact angle and surface tension of droplet.

  • PDF

Preliminary numerical study on hydrogen distribution characteristics in the process that flow regime transits from jet to buoyancy plume in time and space

  • Wang, Di;Tong, Lili;Liu, Luguo;Cao, Xuewu;Zou, Zhiqiang;Wu, Lingjun;Jiang, Xiaowei
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1514-1524
    • /
    • 2019
  • Hydrogen-steam gas mixture may be injected into containment with flow regime varying both spatially and transiently due to wall effect and pressure difference between primary loop and containment in severe accidents induced by loss of coolant accident. Preliminary CFD analysis is conducted to gain information about the helium flow regime transition process from jet to buoyancy plume for forthcoming experimental study. Physical models of impinging jet and wall condensation are validated using separated effect experimental data, firstly. Then helium transportation is analyzed with the effect of jet momentum, buoyancy and wall cooling discussed. Result shows that helium distribution is totally dominated by impinging jet in the beginning, high concentration appears near gas source and wall where jet momentum is strong. With the jet weakening, stable light gas layer without recirculating eddy is established by buoyancy. Transient reversed helium distribution appears due to natural convection resulted from wall cooling, which delays the stratification. It is necessary to concern about hydrogen accumulation in lower space under the containment external cooling strategy. From the perspective of experiment design, measurement point should be set at the height of connecting pipe and near the wall for stratification stability criterion and impinging jet modelling validation.

Time-resolved Observation of Field-dependent Magnetization Reversal Behavior in Co/Pd Multilayer Film

  • Ryu, Kwang-Su;Lee, Kyeong-Dong;Choe, Sug-Bong;Shin, Sung-Chul
    • Journal of Magnetics
    • /
    • 제8권3호
    • /
    • pp.108-112
    • /
    • 2003
  • We report the experimental finding that there exists a transition of magnetization reversal process with varying the applied field in Co/Pd multilayer. We have measured the wall-motion speed V and the nucleation rate R during magnetization reversal via time-resolved direct domain observation, where the magnetization reversal process of Co/Pd multilayer is found to take a transition from thermal activation process to viscous process at the critical field of about 1.87 H$\_$C/ (coercivity). In the thermal activation regime, we find that the field dependences of two activation volumes for the wall-motion process and the nucleation process are different with each other, which reveals that the wall-motion and nucleation experience completely different interactions. In the viscous regime, we find that the wall-mobility is much smaller than a typical value for the sandwiched Co films, which implies that the Co/Pd interfaces in multilayer substantially contribute to the dynamic dissipation.

傳統建築의 들어열개 窓戶形式 變遷에 관한 硏究 - 廳房間을 중심으로 - (The Study on the transition of types of Deul-E-Yul-Gae windows and doors in Korean traditional architecture - focused on the wall between Dae Chung and Bang -)

  • 정명섭
    • 한국주거학회논문집
    • /
    • 제7권2호
    • /
    • pp.57-68
    • /
    • 1996
  • The study is to investiagte the transition of types of Deul-E-Yul-Gae(lift up) windows and doors in Korean traditional architecture which was on the wall batween Dar Chung and Bang. As the result of studying and analysizing the transition of those the following conclusion could be obtained. The first type was to attach windows on the middle of Deul-E-Yul-Gas(lift up) doors, the second type remove windows attached on that or be(Maeng-Jang-Jee) dark paper covered door annexed Bool-Bal-Gee, and the third type to be (Myung-Jang-Jee) bright paper covered door of bottom panel slender ribs which was the most openness. Finally, we could understand the transition which would be changed from the type of(Maeng-Jang-Jee) bright paper covered lift up door of bottom panel slender ribs that had a pliable and open mood.

  • PDF

사면의 변이영역에서 보강재의 변형률 특성 (Strain Characteristics of Reinforcing materials in the transition zone of slopes)

  • 김경태;장대수;장기태;한희수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 사면안정학술발표회
    • /
    • pp.119-127
    • /
    • 2003
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are‘active zone’and‘passive zone’. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

천이 경계층 유동의 벽면 변동 압력에 관한 실험적 연구 (Experimental Study of Wall Pressure Fluctuations in the Regions of Flow Transition)

  • 홍진숙;전재진;김상윤;신구균
    • 한국소음진동공학회논문집
    • /
    • 제12권4호
    • /
    • pp.280-286
    • /
    • 2002
  • It has been long suspected that the transition region may give rise to local pressure fluctuations and radiated sound that are different from those created by the fully-developed turbulent boundary layer at equivalent Reynolds number. Experimental investigation described in this paper concerns the characteristics of pressure fluctuations at the transition. Flush-mounted microphones and hot wires are used to measure the pressure fluctuations and local flow velocities within the boundary layer in the low noise wind tunnel. From this experiment we could observe the spatial and temporal development process of T-S wave using Wigner-Ville method and find the relations between the characteristic frequency of T-S wave and free stream velocity and the boundary layer thickness based on nondimensional pressure spectra scaled on outer variables.

환상유로에 있어서 수직고온관의 과도적 냉각과정에 관한 연구 (A study on the transient cooling process of a vertical-high temperature tube in an annular flow channel)

  • 정대인;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.156-164
    • /
    • 1986
  • In the case of boiling on high temperature wall, vapor film covers fully or parcially the surface. This phenomenon, film boiling or transition boiling, is very important in the surface heat treatment of metal, design of cryogenic heat exchanger and emergency cooling of nuclear reactor. Mainly supposed hydraulic-thermal accidents in nuclear reactor are LCCA (Loss of Coolant Accident) and PCM (Power-Cooling Mismatch). Recently, world-wide studies on reflooding of high temperature rod bundles after the occurrence of the above accidents focus attention on wall temperature history and required time in transient cooling process, wall superheat at rewet point, heat flux-wall superheat relationship beyond the transition boiling region, and two-phase flow state near the surface. It is considered that the further systematical study in this field will be in need in spite of the previous results in ref. (2), (3), (4). The paper is the study about the fast transient cooling process following the wall temperature excursion under the CHF (Critical Heat Flux) condition in a forced convective subcooled boiling system. The test section is a vertically arranged concentric annulus of 800 mm long and 10 mm hydraulic diameter. The inner tube, SUS 304 of 400 mm long, 8 mm I.D, and 7 mm O.D., is heated uniformly by the low voltage AC power. The wall temperature measurements were performed at the axial distance from the inlet of the heating tube, z=390 mm. 6 chromel- alumel thermocouples of 76 .mu.m were press fitted to the inner surface of the heating tube periphery. To investigate the heat transfer characteristics during the fast transient cooling process, the outer surface (fluid side) temperature and the surface heat flux are computed from the measured inner surface temperature history by means of a numerical method for inverse problems of transient heat conduction. Present cooling (boiling) curve is sufficiently compared with the previous results.

  • PDF