• 제목/요약/키워드: wall-to-wall transition

검색결과 204건 처리시간 0.027초

회전날개주위 분자천이유동에 관한 수치해석적 연구 (A numerical study on the molecular transition flow for the rotating blades)

  • 허중식;황영규;김동권
    • 대한기계학회논문집B
    • /
    • 제22권5호
    • /
    • pp.640-650
    • /
    • 1998
  • Pumping performances of a helical molecular drag dump(MDP) and of a radial MDPs are numerically analyzed by using the direct simulation Monte Carlo (DSMC) method. A helical- and radial-MDP have rotating pumping channels cut on a cylinder and on a disk, respectively. For a helical MDP, the present results agree quantitatively with the previously known numerical results. For radial MDPs, both of the Type 1 (having pumping channels cut on the stationary disk) and of the Type 2 (having pumping channels cut on the rotating disk) are analyzed to predict their performances for various parameters, i.e., the radius of curvature center of the channel wall, the depth of the channel, the clearance between housing and disk, and the rotating speed. The results show that the performance of the Type 2 is superior to that of the Type 1, and that for all types the pumping efficiency decreases as the clearance increases. Also, the radial type MDP has larger leakage losses in the direction of pumping channel than does the helical one.

정사각형 밀폐공간내에서 수평격판에 의한 자연대류의 진동현상 (Oscillatory Motion of Natural Convection in a Square Enclosure with a Horizontal Partition)

  • 김점수;정인기;송동주
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.285-294
    • /
    • 1993
  • An oscillatory motion of natural convection in a two-dimensional square enclosure fitted with a horizontal partition is investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was positioned perpendicularly at the mid-height of one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were carried out with the variations of the partition length and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). As the results, an oscillatory motion of natural convection has perfectly shown the periodicity with the decrease of Rayleigh number, and the stability was reduced to a chaotic state with the increase of Rayleigh number. The period of oscillation gets shorten with the decrease of the partition length and the increase of Rayleigh number. The frequency of oscillation obtained by the variations of stream function is more similar to the experimental results than that of the average Nusselt number. The stability of oscillation grows worse with the increase of Rayleigh number. The transition Rayleigh number for the chaos is gradually decreased with the increase of the partition length.

  • PDF

후래시 현상을 수반하는 수직증발관내에서의 2상유동에 관한 실험적 연구 (Experimental study on two-phase flow behavior inside a vertical tube evaporator under flashing phenomenon)

  • 이상용;송시홍;이상호
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.833-846
    • /
    • 1988
  • 본 연구에서는 후래시현상과 가열이 동시에 존재하면서 증발을 일으키는 수직 증발관내에서의 유동양식에 대해서, 우선 전기 프로우브를 이용하여 관내의 유동양식 에 따른 전기적 신호를 얻고, 시진실험 방법(photographic experimental method)을 통 하여 이를 확인한다. 또한, 전기 프로우브를 통하여 얻은 신호는 적절한 해석과정을 통해 수직 증발관내의 유동에 따른 기공률을 측정하는데 적용된다.

수리실험 및 수치모의를 이용한 제방붕괴 흐름해석 (Levee Breach Flow by Experiment and Numerical Simulation)

  • 김주영;이정규;이진우;조용식
    • 한국수자원학회논문집
    • /
    • 제44권6호
    • /
    • pp.461-470
    • /
    • 2011
  • Abrupt and gradual levee breach analyses on the flat domain were implemented by laboratory experiments and numerical simulations. To avoid the reflective wave from the side wall the experiment was performed in a large domain surrounded by waterway. A numerical model was developed for solving the two-dimensional gradual levee breach flow. The results of the numerical simulation developed in this study showed good agreement with those of the experimental data. However, even if the numerical schemes effectively replicated the trends of the observed water depth for the first shock, there were little differences for the second shock. In addition, even though the model considered the Smagorinsky horizontal eddy viscosity, the location and height of the hydraulic jump in the numerical simulation were not fairly well agree with experimental measurements. This shows the shallow water equation solver has a limitation which does not exactly reproduce the energy dissipation from the hydraulic jump. Further study might be required, considering the energy dissipation due to the hydraulic jump or transition flow from reflective wave.

저드파트너쉽 쇼핑센터의 표현 특성에 관한 연구 - 테마파크형 공간구성을 중심으로 - (An study on the Expressive Characteristics of Jerde Partnership's shopping center - Focused on Space Composition of Theme Park-style -)

  • 하성주;하미경
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2007년도 추계학술발표대회 논문집
    • /
    • pp.103-106
    • /
    • 2007
  • The idea of shopping is changed from a purchase of merchandise to an experience of pleasure. This study is a space composition analysis for the introduction of theme in multi-plex shopping center design to reflect variable consumer trend and company marketing strategy. The study progressed through theoretical consideration and substance analysis about the shopping centers which had been designed by Jerd Partnership from 2000 in Japan. The following is result. The path is a sole main street that is made of curve form, parallel and vertical circulating rout and movement of human being. It leads continuity. The node and landmarks have a circular court with typifier as powerful center, character of transition space and event for experience. It makes locational quality. The districts are composed of retail shops, restaurants and culture facilities and the edge is represented by closed vertical wall and parapet. It induces a domain. The characteristic of Jerde shopping center is an experience of theme environment through the path as betweenness space with a story based on a main theme.

  • PDF

수평격판을 갖는 정사각형 밀폐공간내에서 자연대류 유동 및 열전달 (Natural Convective Flow and Heat Transfer in a Square Enclosure with a Horizontal Partition)

  • 정인기;김점수;송동주
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2304-2314
    • /
    • 1993
  • Natural convective flow and heat transfer in a two-dimensional square enclosure fitted with a horizontal partition are investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was situated perpendicularly at the one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were carried out with the variations of length, position and thermal conductivity of the partition, and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). As the results, an oscillatory motion of natural convection is resulted in a sudden rise of overall heat transfer, but the increase of length of partition is significantly restrained the increase of Nusselt number. The maximum heat transfer was shown just before the transition of the direction of oscillating flow. An oscillatory motion of flow was perfectly shown the stability with the decrease of the length of partition and Rayleigh number. Also, the heat transfer was raised with the increase of the thermal conductivity in proportion to the increase of the length of partition. The stability and oscillation of flow are affected by the position of partition.

알루미늄 합금박판 비등온 성형공정 스프링백 해석용 유한요소 프로그램 개발 ( 1부 : 실험 ) (Development of Finite Element Program for Analyzing Springback Phenomena of Non-isothermal Forming Processes for Aluminum Alloy Sheets(Part 1 : Experiment))

  • 금영탁;유동열;한병엽
    • 소성∙가공
    • /
    • 제12권3호
    • /
    • pp.202-207
    • /
    • 2003
  • In order to examine the springback amount and material properties of aluminum alloy sheets (AL1050 and AL5052) in the warm forming which forms the sheet above the room temperature, the stretch bending and draw bending tests and tensile test in various high temperatures are carried out. The warm forming temperature 15$0^{\circ}C$ is a transition in terms of the material properties: over the forming temperature 15$0^{\circ}C$, them $\sigma$$_{YS}$ , $\sigma$$_{TS}$ , E, K, n, etc. are bigger but $\varepsilon$ and plastic strain ratio are smaller. Below the forming temperature 15$0^{\circ}C$, there are no big differences in material properties as the forming temperature changes. AL5052 sheet has more springback effect than AL1050 sheet. While the springbacks of AL5052 and AL1050 sheets show a big reduction over the warm forming temperature 15$0^{\circ}C$ in the stretch bending test, the springback rapidly reduces in the warm forming temperature 15$0^{\circ}C$-20$0^{\circ}C$ for AL5052 sheet and 20$0^{\circ}C$-25$0^{\circ}C$ for AL1050 sheet in the draw bending test.

Orifice Inlet효과에 의한 이젝터 성능에 관한 수치해석적 연구 (Numerical Investigation of the Effects of an Orifice Inlet on the Performance of an Ejector)

  • ;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.318-322
    • /
    • 2009
  • Supersonic ejectors are simple mechanical components, which generally perform mixing and/or recompression of two fluid streams. Ejectors have found many applications in engineering. In aerospace engineering, they are used for altitude testing of a propulsion system by reducing the pressure of a test chamber. It is composed of three major sections: a vacuum test chamber, a propulsive nozzle, and a supersonic exhaust diffuser. This paper aims at the improvement of ejector-diffuser performance by focusing attention on reducing exhaust back flow into the test chamber, since alteration of the backflow or recirculation pattern appears as one of the potential means of significantly improving low supersonic ejector-diffuser performance. The simplest backflow-reduction device was an orifice plate at the duct inlet, which would pass the jet and entrained fluid but impede the movement of fluid upstream along the wall. Results clearly showed that the performance of ejector-diffuser system was improved for certain a range of system pressure ratios, where as there was no appreciable transition in the performance for lower pressure ratios and the orifice plate was detrimental to the ejector performance for higher pressure ratios. It is found that an appropriately sized orifice system should produce considerable improvement in the ejector-diffuser performance in the intended range of pressure ratios.

  • PDF

직사각형 밀폐공간내에서의 복사 및 자연대류 열전달 (Combined Radiation-Natural Convection Heat Transfer in a Rectangular Enclosure)

  • 김기훈;이택식;이준식
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.331-344
    • /
    • 1987
  • 본 연구에서는 직사각형 밀폐공간내에서 자연대류와 복사의 상호 영향에 대해 서 P-1 근사를 이용하여 수치적으로 해석하였다.밀폐공간내에서의 온도분포, 속도 분포 및 열전달계수를 구하였으며 열경계층내에서의 전도와 복사의 상호 영향에 대하 여 고찰하였다. 표면 복사만이 존재하는 경우에 대해서도 고찰함으로써 P-1 근사의 적용한계를 규명하였다. 벽면을 산광 방사 및 반사체(diffuse emitter and reflec- tor)로, 기체는 회색체(gray body)로 가정하였다. 이는 복사 물성치의 파장에 따른 변화를 고려할 때의 대단히 복잡한 계산 과정을 피할 수 있고, 현재의 이론적 수준에 비추어 복사 열전달의 열향을 정성적으로 규명하는데 타당한 가정이다.

Preparation of Styrene-Ethyl acylate Core-shell Structured Detection Materials for aMeasurement of the Wall Contamination by Emulsion Polymerization

  • Hwang, Ho-Sang;Seo, Bum-Kyoung;Lee, Dong-Gyu;Lee, Kune-Woo
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2009년도 학술논문요약집
    • /
    • pp.84-85
    • /
    • 2009
  • New approaches for detecting, preventing and remedying environmental damage are important for protection of the environment. Procedures must be developed and implemented to reduce the amount of waste produced in chemical processes, to detect the presence and/or concentration of contaminants and decontaminate fouled environments. Contamination can be classified into three general types: airborne, surface and structural. The most dangerous type is airborne contamination, because of the opportunity for inhalation and ingestion. The second most dangerous type is surface contamination. Surface contamination can be transferred to workers by casual contact and if disturbed can easily be made airborne. The decontamination of the surface in the nuclear facilities has been widely studied with particular emphasis on small and large surfaces. The amount of wastes being produced during decommissioning of nuclear facilities is much higher than the total wastes cumulated during operation. And, the process of decommissioning has a strong possibility of personal's exposure and emission to environment of the radioactive contaminants, requiring through monitoring and estimation of radiation and radioactivity. So, it is important to monitor the radioactive contamination level of the nuclear facilities for the determination of the decontamination method, the establishment of the decommissioning planning, and the worker's safety. But it is very difficult to measure the surface contamination of the floor and wall in the highly contaminated facilities. In this study, the poly(styrene-ethyl acrylate) [poly(St-EA)] core-shell composite polymer for measurement of the radioactive contamination was synthesized by the method of emulsion polymerization. The morphology of the poly(St-EA) composite emulsion particle was core-shell structure, with polystyrene (PS)as the core and poly(ethyl acrylate) (PEA) as the shell. Core-shell polymers of styrene (St)/ethyl acrylate (EA) pair were prepared by sequential emulsion polymerization in the presence of sodium dodecyl sulfate (SOS) as an emulsifier using ammonium persulfate (APS) as an initiator. The polymer was made by impregnating organic scintillators, 2,5-diphenyloxazole (PPO) and 1,4-bis[5-phenyl-2-oxazol]benzene (POPOP). Related tests and analysis confirmed the success in synthesis of composite polymer. The products are characterized by IT-IR spectroscopy, TGA that were used, respectively, to show the structure, the thermal stability of the prepared polymer. Two-phase particles with a core-shell structure were obtained in experiments where the estimated glass transition temperature and the morphologies of emulsion particles. Radiation pollution level the detection about under using examined the beta rays. The morphology of the poly(St-EA) composite polymer synthesized by the method of emulsion polymerization was a core-shell structure, as shown in Fig. 1. Core-shell materials consist of a core structural domain covered by a shell domain. Clearly, the entire surface of PS core was covered by PEA. The inner region was a PS core and the outer region was a PEA shell. The particle size distribution showed similar in the range 350-360 nm.

  • PDF