• Title/Summary/Keyword: wall storage system

Search Result 107, Processing Time 0.029 seconds

An Experimental Study on tee Heat Transfer Enhancement Effect of the Coil Fins for Ice Storage System (빙축열 시스템에서의 코일 휜의 열전달 촉진 효과에 관한 실험적 연구)

  • 성병호;이분희;임광빈;김철주
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.219-224
    • /
    • 2004
  • The present study was to investigate the heat transfer enhancement effect of coil wire fins in an ice storage system. For the two cases of tubes with internal brine flows, a finned tube with coil wires on its outer surface and a smooth tube, the rates of ice layer were tested and compared for both the icing processes. The coil fins were made of a stainless steel wire with a dia. of 2.0(mm), and the coil had an outer dia. of 10(mm) and a helix angle of 60($^{\circ}$). The experimental results showed that the coil fins could substantially reduce the thermal resistance of the ice layer, and enhance the heat flow rates between the water in the storage tank and the brine. The ice storing time was found to be shortened by 13(%) for the coil fins to get the same amount of ice layer that was built on the smooth tube wall for 10 hours of operation when the same thermal conditions were provided.

  • PDF

FLUID-STRUCTURE INTERACTION ANALYSIS OF LIQUID STORAGE STRUCTURES (액체 저장구조물의 유체-구조물 상호작용 해석)

  • 윤정방;김진웅;서정문;전영선
    • Computational Structural Engineering
    • /
    • v.5 no.4
    • /
    • pp.103-111
    • /
    • 1992
  • In this paper, liquid sloshing effects in rectangular storage structures for spent fuel under earthquake loadings are investigated. Eulerian and Lagrangian approaches are presented. The Eulerian approach is carried out by solving the boundary value problem for the fluid motion. In the Lagrangian approach, the fluid as well as the storage structure is modelled by the finite element method. The fluid region is discretized by using fluid elements. The (1*1)-reduced integration is carried out for constructing the stiffness matrices of the fluid elements. Seismic analysis of the coupled system is carried out by the response spectra method. The numerical results show that the fluid forces on the wall obtained by two approaches are in good agreements. By including the effect of the wall flexibility, the hydrodynamic forces due to fluid motion can be increased very significantly.

  • PDF

A Study on the Safety of Small LPG Storage Tanks at External Fires (외부화재시 LPG 소형저장탱크의 안전성에 관한 연구)

  • Yim, Ji-Pyo;Ma, Byung-Chol;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.64-72
    • /
    • 2015
  • The purpose of this study is to study the safety of a small LPG storage tank with a capacity less than 3 ton when it is exposed to an external fire. First, simulation studies were carried out using ASPEN Plus and PHAST to demonstrate that overpressurization in the tank can be relieved by discharging the LPG through an adequately sized safety valve, but the release may lead to the secondary risk of fire and explosion around the tank. Next, the temporal variations of the temperatures of the lading and tank wall were obtained using AFFTAC, which showed that the tank wall adjacent to the vapor space could be overheated in about 11 min to such a point that the weakened strength might cause a rupture of the tank and subsequent BLEVE. The consequences of the BLEVE were estimated using PHAST. Finally, several practical measures for preventing the hazards of overheating were suggested, including an anti-explosion device, sprinkling system, insulation, heat-proof coating, and enhanced safety factor for tank fabrication. The effectiveness of these measures were examined by simulations using AFFTAC and ASPEN Plus.

Prevention of Soil Contamination from Underground Storage Facilities of Petroleum Product and Hazardous Chemical Compounds (유류 및 유해화학물질 저장시설에서의 토양오염 방지대책)

  • 배우근;홍종철;정진욱;김종호
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.40-47
    • /
    • 2002
  • The practices of the construction and management of the petroleum and hazardous chemical compound storage facilities in Korea were investigated extensively, and the problems were identified. The advanced technologies in the U.S.A were comparatively studied. Considering the effectiveness of leak prevention and applicability, the following measures were suggested. To prevent corrosion of a tank, a clad tank, an interior lining tank, or a double-wall tank were thought to be the most cost effective. For piping. use of non-metalic materials was suggested. A catchment basin seemed to be effective for preventing spills. For monitoring of leaks, constructions of more than one of detection systems, such as an automatic leak detection device. a vapor detection system, a groundwater monitoring system, or a double-wall monitoring system, were recommended.

Optimal Rechlorination for the Regulation of Chlorine Residuals in Water Distribution Systems (배수관망의 잔류염소 평활화를 위한 최적 재염소 처리)

  • Yoon, Jae-Heung;Oh, Jung-Woo;Choi, Young-Song
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.90-98
    • /
    • 1998
  • The optimal rechlorination in water distribution systems was investigated by incorporating optimization techniques into a numerical water quality model. For a hypothetical system that consists of 10 junctions including a storage tank and 12 links, the bulk ($k_b$) and pipe-wall ($k_w$) decay-rate constants of chlorine residual are assumed to be 2.0 1/day and 1.5 m/day, respectively. It was also assumed that the lower and upper limits of chlorine residual in the network are 0.2 mg/L and 0.6 mg/L. When the chlorine source is only the storage tank (without rechlorination), the high levels of chlorine residual appear near the storage tank to maintain the chlorine residuals above the lower limit over the junctions. On the other hand, the chlorine residuals in the network are distribute within the desirable range (0.2 - 0.6 mg/L) after the optimal rechlorination through five injection sites including the storage tank. In case of a real water distribution system that comprises 28 junctions including a clear well and 27 links, the bulk and pipe-wall decay-rate constants are 0.3 1/day and 0.2 m/day, respectively. Before rechlorination, the required chlorine residual at the clearwell is 5.1 mg/L to keep the chlorine residuals above the minimum level (0.6 mg/L) over the junctions. By the optimal rechlorination at five injection sites, the chlorine residuals are distributed within a desirable range of 0.6 mg/L through 2.0 mg/L, which can avoid the excess of chlorine residuals near the clear well. Consequently, total chlirine doses are decreased by 81% in the hypothetical distribution network and 69 % in the real distribution network for satisfying the minimum chlorine residuals.

  • PDF

A Study on Design Charateristic of Living Room Storage Furniture (거실수납가구의 디자인 특성 분석)

  • Park, Hea-Sook;Kim, Soo-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.1
    • /
    • pp.94-99
    • /
    • 2010
  • The purpose of this study is to develop living room storage furniture with multiple functions and for analyzing living room system furniture that can correspond with lifestyles in the living room. Literature survey was used by collecting data on interior design books and magazines. System furniture is very functional depending on the purpose and spaces, and can be modified effectively with the development of design based on the resident's demand. Living room furniture was mostly arranged by two types. One was lower and slimmer in order to use the space effectively, the other totally occupied one side of the living room wall. Furniture combined with multiple functions of lights and electronics can increase the satisfaction and convenience of users. And furniture maximizes storage space and is systemized so that mixture and arrangement are diversified. Flexible and active way furniture that accept various electronic fixtures and performances in the living room. Furniture forms, materials, and colors will be designed for the functions and atmosphere of living rooms. This results will contribute to develop furniture that has additional features such as lighting and electronic appliances hereafter.

Enhancement of Stratification for Solar Water Storage Tank with Spiral Jacket and Coil(Part 2 Simulation) (나선유로에 의한 태양열 축열조 성층화 촉진(제2보 시뮬레이션))

  • Lee, Seong Hoon;Son, Hyo Seok;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • We have performed experiments to enhance the stratification in a storage tank in order to raise the collector efficiency and solar fraction in solar thermal systems. The storage tank with a spiral jacket in the side wall has a scroll-shaped heat exchanger coil added to the upper part. The performance was compared between only the side and upper-side heating part through simulation using TRNSYS under the same weather conditions and initial conditions. As a result, the upper-side heating has a 4.2% advantage in solar fraction, but almost no increase in collector efficiency.

Evaluation of one component structural sealant for curtain wall. (커튼월용 1액형 구조용 실란트 물성 평가 연구)

  • Han, Chang-Hwa;Jung, Jin-Young;Bae, Ki-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.228-229
    • /
    • 2014
  • Recently, to ensure the high openness and prospect right of the building, curtain wall system is mainly applied to the high-rise buildings at domestic and overseas. As a result, the use of Structural Sealant is increasing. Structural Glazing Sealant is applied with the glass and AL-FRAME (Mullion) that the strong structural strength is required to hold. However, the structural sealant at the construction site in a variety of external influences, such as wind load, thermal load, uv, chemical pollutants etc, in case of storing condition, if structural sealant stored in high temperature for a long period time, it will not perform well compared with initial performance. In this study, the influence of the performance of one-component structural sealant evaluated for proper storage conditions at the construction site and how to use the non-intended.

  • PDF

The Research of Plans for Modernization in the traditional design factors, Aimed at Long Life Housing - Focused in the Infill System for Composition of Indoor Space - (장수명 공동주택을 대상으로 한 전통디자인요소의 현대화방안에 관한 연구 - 실내공간구성을 위한 가변요소를 중심으로 -)

  • Han, Nam-Soo;Lee, Young;Park, Woo-Jang;Park, Joon-Young;Ryu, Dong-Soo
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.113-121
    • /
    • 2010
  • This research is aimed at the development of Long Life Housing, which can realize sustainable construction and environment. It also promotes practical use of Long Life Housing with evaluation of the field application through Mockup House. This research is one of the important tools to realize Long Life Housing and deducts various traditional design's element technology to cope with demands of change of life cycle and style of residents. this study set three elements of plans for modernization in the traditional design factors that opening, wall and bottom as space composition elements of interior facts. first, Jang-ji wall and storage wall system separated from elements of wall that applied modernize elements of the wall. second, element of opening was restructure swing-lift-up opening system into modernize. third, maru and toet-maru system separated from elements of bottom that was applied modernize elements of the bottom. each elements segregation with four types as basic type, separate type, movable type and mixed type. This research make a proposal of plans for modernization in the traditional design factors, aimed at Long Life Housing through these four types blend. In addition, it points to promote realization of the sustainable 'Korea-style Long Life Housing' through modernization.

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.