• 제목/요약/키워드: wall motion

검색결과 593건 처리시간 0.099초

Shape anisotropy and magnetic properties of Co/Ni anti-dot arrays

  • Deshpande, N.G.;Seo, M.S.;Kim, J.M.;Lee, S.J.;Lee, Y.P.;Rhee, J.Y.;Kim, K.W.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.444-444
    • /
    • 2011
  • Recently, patterned magnetic films and elements attract a wide interest due to their technological potentials in ultrahigh-density magnetic recording and spintronic devices. Among those patterned magnetic structures, magnetic anti-dot patterning induces a strong shape anisotropy in the film, which can control the magnetic properties such as coercivity, permeability, magnetization reversal process, and magneto-resistance. While majority of the previous works have been concentrated on anti-dot arrays with a single magnetic layer, there has been little work on multilayered anti-dot arrays. In this work, we report on study of the magnetic properties of bilayered anti-dot system consisting of upper perforated Co layer of 40 nm and lower continuous Ni layer of 5 nm thick, fabricated by photolithography and wet-etching processes. The magnetic hysteresis (M-H) loops were measured with a superconducting-quantum-interference-device (SQUID) magnetometer (Quantum Design: MPMS). For comparison, investigations on continuous Co thin film and single-layer Co anti-dot arrays were also performed. The magnetic-domain configuration has been measured by using a magnetic force microscope (PSIA: XE-100) equipped with magnetic tips (Nanosensors). An external electromagnet was employed while obtaining the MFM images. The MFM images revealed well-defined periodic domain networks which arise owing to the anisotropies such as magnetic uniaxial anisotropy, configurational anisotropy, etc. The inclusion of holes in a uniform magnetic film and the insertion of a uniform thin Ni layer, drastically affected the coercivity as compared with single Co anti-dot array, without severely affecting the saturation magnetization ($M_s$). The observed changes in the magnetic properties are closely related to the patterning that hinders the domain-wall motion as well as to the magneto-anisotropic bilayer structure.

  • PDF

Permalloy/Cu 다층막 자화반전의 미세 구조 (Fine Structure in Magnetization Reversal of Permalloy/Cu Multilayer)

  • 이긍원;염민수;장인우;변상진;이제형;박병기
    • 한국자기학회지
    • /
    • 제11권5호
    • /
    • pp.179-183
    • /
    • 2001
  • Glass/Ni$_{83}$Fe$_{17}$(2 nm)/[Cu(2 nm)Ni$_{83}$Fe$_{17}$(20 nm)]$_{50}$ 다층박막의 평면 홀 효과를 측정하였다. 평면 홀 효과에서 반복된 톱니모양의 홀 효과 신호가 관측되었다. 그 원인으로 갑작스러운 자벽의 이동이 홀 효과로 관측된 것이라는 가설을 세울 수 있다. 이러한 톱니모양의 평면 홀 효과는 모든 측정방향에서 관측되었다. 각 자성층의 전체 자화만이 자기저항을 결정하므로 자기저항의 특성곡선에서는 이러한 톱니모양에 해당하는 신호가 관측되지 않았다. 톱니모양의 근본 원인에 대한 연구는 더욱 수행되어야할 것이다.것이다.

  • PDF

ICT 기반 스마트 멀티터치 영상 출력 시스템 (Smart Touch Screen Output System Based on ICT)

  • 박유진;최시웅;황승국
    • 한국지능시스템학회논문지
    • /
    • 제27권2호
    • /
    • pp.138-143
    • /
    • 2017
  • 본 연구에서는 ICT기반으로 한 스마트 터치 영상 출력 시스템의 구현을 목적으로 한다. 여기서의 영상 출력 시스템은 영상 감지 반응 센서를 통해 인식감지를 하여 움직임 패턴을 영상 화면과 실제 사용하는 해상도에 차이가 있으므로 이 오차를 최소화하기 위해서 화면 좌표인식 형태의 펜 터치 방식을 이용하는 스마트 영상 출력시스템을 말한다. 이를 위하여 ICT 기반의 기술을 응용하여 영상 데이터 출력을 기존의 유선 방식이 아닌 무선 방식과 스마트 터치 기능으로 PC 및 노트북, 모니터, 키보드, 마우스 없이도 원거리에서 조작이 가능한 스마트 영상 출력 시스템을 구축하였다. 본 연구결과는 스크린 없이도 벽면만 있으면 영상을 출력할 수 있고, 이 출력된 영상에서 펜으로 작동할 수 있다는 것이 특징이다.

일반적인 내벽을 가진 자유바닥 곡면 파켓의 NC 가공을 위한 단일화된 황삭과 정삭 알고리즘 - Part 1. Simulation (A unified rough and finish cut algorithm for NC machining of free form pockets with general polygon - Part 1. Simulation)

  • Park, Yong-hoon;Cho, Chi-woon;Kim, Sang-jin
    • 한국산업정보학회논문지
    • /
    • 제9권1호
    • /
    • pp.7-16
    • /
    • 2004
  • 효율적인 최종 NC코드를 만들어내기 위해서 공구경로는 효과적인 방법으로 결정되어 져야한다. 이는 3축 CNC 공작기계상에서 자유형상의 벽을 가진 자유곡면을 가공할 때 특히 중요하다. 많은 CAD/CAM 시스템들은 자유곡면가공을 위한 NC코드 생성 시 직선 보간을 이용한다. 그러나 이 방법은 가공된 바닥 표면의 매끄러움과 가공시간, 그리고 CL파일 사이즈를 줄이기 위해서 보정되어야 한다. 곡선 가공이 이러한 문제들을 줄이기 위한 해결책이 될 수 있다. 단일화된 황삭과 정삭 알고리즘과 공구경로가 그래픽으로 시뮬레이션 되었다. 본 연구에서는 자유곡면 바닥을 가진 파켓을 3축 CNC 공작기계를 이용하여 일반적인 파켓 밀링을 위한 직선 보간과 직선+아크를 혼합한 보간을 위한 NC 공구경로 데이터를 만들기 위한 3D 격자 항행 알고리즘을 개발하였다.

  • PDF

복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구 (Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor)

  • 민세동;김진권;신항식;윤용현;이충근;이정환;이명호
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.

Dynamic response of a lined tunnel with transmitting boundaries

  • Fattah, Mohammed Y.;Hamoo, Mohammed J.;Dawood, Shatha H.
    • Earthquakes and Structures
    • /
    • 제8권1호
    • /
    • pp.275-304
    • /
    • 2015
  • The objective of this paper is to investigate the validity of transmitting boundaries in dynamic analysis of soil-structure interaction problems. As a case study, the proposed Baghdad metro line is considered. The information about the dimensions and the material properties of the concrete tunnel and surrounding soil were obtained from a previous study. A parametric study is carried out to investigate the effect of several parameters including the peak value of the horizontal component of earthquake displacement records and the frequency of the dynamic load. The computer program (Mod-MIXDYN) is used for the analysis. The numerical results are analyzed for three conditions; finite boundaries (traditional boundaries), infinite boundaries modelled by infinite elements (5-node mapped infinite element) presented by Selvadurai and Karpurapu, 1988), and infinite boundaries modelled by dashpot elements (viscous boundaries). It was found that the transmitting boundary absorbs most of the incident energy. The distinct reflections observed for the "fixed boundaries" disappear by using "transmitted boundaries". This is true for both cases of using viscous boundaries or mapped infinite elements. The type and location of the dynamic load represent two controlling factors in deciding the importance of using infinite boundaries. It was found that the results present significant differences when earthquake is applied as a base motion or a pressure load is applied at the surface ground. The peak value of the vertical displacement at nodes A, B, E and F (located at the tunnel's crown and side walls, and at the surface above the tunnel and at the surface 6.5 m away from tunnel's centre respectively) increases with the frequency of the surface pressure load for both cases 1 and 2 (traditional boundaries and mapped infinite elements respectively) while it decreases for case 3 (viscous boundaries). The modular ratio Ec/Es (modulus of elasticity of the concrete lining to that of the surrounding soil) has a considerable effect on the peak value of the horizontal displacement at node B (on the side wall of the tunnel lining) increase about (17.5) times, for the three cases (1, 2, and 3).

Magnetisation Reversal Dynamics in Epitaxial Fe/GaAs(001) and Fe/InAs(001) Thin Films

  • Lee, W.Y;Shin, K.H;Kim, H.J;Bland, J.A.C.
    • Journal of Magnetics
    • /
    • 제6권2호
    • /
    • pp.47-52
    • /
    • 2001
  • We present the magnetisation reversal dynamics of epitaxial Fe thin films grown on GaAs(001) and InAs(001) studied as a function of field sweep rate in the range 0.01-160 kOe/s using magneto-optic Kerr effect (MOKE). For 55 and 250 ${\AA}$ Fe/GaAs(001), we find that the hysteresis loop area A follows the scaling relation $A\propto H_{\alpha} \;with\; \alpha=0.03\sim0.05$ at low sweep rates and 0.33~0.40 at high sweep rates. For the 150${\AA}$ Fe/InAs(001) film, $\alpha$is found to be ~0.02 at low sweep rates and ~0.17 at high sweep rates. The differing values of $\alpha$ are attributed to a change of the magnetisation reversal process with increasing sweep rate. Domain wall motion dominates the magnetisation reversal at low sweep rates, but becomes less significant with increasing sweep rate. At high sweep rates, the variation of the dynamic coercivity $H_c{^*}$ is attributed to domain nucleation dominating the reversal process. The results of magnetic relaxation studies for easy-axis reversal are consistent with the sweeping of one or more walls through the entire probed region (~100$\mu m$). Domain images obtained by scanning Kerr microscopy during the easy cubic axis reversal process reveal large area domains separated by zigzag walls.

  • PDF

Development and Evaluation of the V-Catch Vision System

  • Kim, Dong Keun;Cho, Yongjoo;Park, Kyoung Shin
    • 한국컴퓨터정보학회논문지
    • /
    • 제27권3호
    • /
    • pp.45-52
    • /
    • 2022
  • 체감형 스포츠 게임은 센서나 카메라를 이용하여 사용자의 신체 움직임을 추적하고 현실감을 느끼게 하는 운동 게임이다. 최근 체감형 스포츠 게임을 학교 체육활동에 사용하기 위해 가상현실 실내 스포츠룸 시스템을 설치하고 있다. 그러나 이러한 시스템은 주로 화면 터치 사용자 상호작용을 사용한다. 본 연구에서는 2차원 벽 터치 인터랙션이 아닌 3차원 공간에서 사용자의 움직임을 추적할 수 있도록 AI 이미지 인식 기술을 사용하는 브이캐치 비전 시스템을 개발했다. 그리고 본 시스템의 운동 효과를 알아보기 위하여 사용성 평가 실험을 진행했다. 실험에서 피험자에게 혈중 산소 포화도와 실시간 심박변이와 키넥트 골격 이동량, 각도 변화량을 측정하여 정량적 운동 효과를 살펴보았다. 실험 결과 브이캐치 비젼 시스템 사용 시 통계적으로 유의미한 심박수 증가와 신체 움직임양 증가로 운동 효과가 있었던 것으로 나타났다. 실험후 설문조사 주관적 평가 결과에서 대부분의 피실험자들은 이 시스템을 사용한 운동이 재미있고 만족스러워했다.

The July 2, 2017, Lantian landslide in Leibo, China: mechanisms and mitigation measures

  • He, Kun;Ma, Guotao;Hu, Xiewen;Liu, Bo;Han, Mei
    • Geomechanics and Engineering
    • /
    • 제28권3호
    • /
    • pp.283-298
    • /
    • 2022
  • Landslides triggered by the combination of heavy precipitation and anthropological disturbance in hilly areas cause severe damage to human lives, properties, and infrastructure constructions. A comprehensive investigation of the influencing factors and failure mechanisms of landslides are significant for disaster mitigation and prevention. This paper utilized the combination of detailed geological investigation, physical experimental testing as well as numerical modelling to determine the failure mechanism, and proposed a countermeasures of the Lantian landslide occurred on 2, July 2017. The results reveal that the Lantian landslide is a catastrophic reactivated slide which occurred in an active tectonic region in Southwest China. Because of the unique geological settings, the fully to highly weathered basalts in the study area with well-developed fractures favored the rainwater infiltration, which is the beneficial to slide reactivation. Engineering excavation and heavy precipitation are the main triggering factors to activate the slide motion. Two failure stages have been identified in the landslide. The first phase involves a shallow mass collapse originated at the upper slopes, which extends from the road to platform at rear part, which is triggered by excavation in the landslide region. Subjected to the following prolonged rainfall from 19 June to 2 July, 2017, the pore water pressure of the slope continually increased, and the groundwater table successively rise, resulting in a significant decrease of soil strength which leads to successive large-scale deep slide. Thereinto, the shallow collapse played a significant role in the formation of the deep slide. Based on the formation mechanisms of the landslide, detailed engineering mitigation measures, involving slope cutting, anchor cable frame, shotcrete and anchorage, retaining wall and intercepting ditch were suggested to reduce the future failure risk of the landslide.

Clinical outcomes and characteristics of acute myocardial infarction patients with developing fever after percutaneous coronary intervention

  • Jae-Geun Lee;Yeekyoung Ko;Joon Hyouk Choi;Jeong Rae Yoo;Misun Kim;Ki Yung Boo;Jong Wook Beom;Song-Yi Kim;Seung-Jae Joo
    • Journal of Medicine and Life Science
    • /
    • 제19권2호
    • /
    • pp.46-56
    • /
    • 2022
  • The incidence of fever complicating percutaneous coronary intervention (PCI) is rare. However, little is known regarding the cause of fever after PCI. Therefore, this study aimed to determine the clinical characteristics of patients with acute myocardial infarction (AMI), with or without fever, after PCI. We enrolled a total of 926 AMI patients who underwent PCI. Body temperature (BT) was measured every 4 hours or 8 hours for 5 days after PCI. Patients were divided into two groups according to BT as follows: BT<37.7℃ (no-fever group) and BT ≥37.7℃ (fever group). The 2 years clinical outcomes were compared subsequently. Fever after PCI was associated with higher incidence of major adverse cardiac events (MACE) (hazard ratio [HR], 1.56; 95% confidence interval [CI], 1.07-2.28; P=0.021), all-cause death (HR, 2.32; 95% CI, 1.18-4.45; P=0.014), cardiac death (CD) (HR, 2.57; 95% CI, 1.02-6.76; P=0.049), and any revascularization (HR, 1.69; 95% CI, 1.02-2.81; P=0.044) than without fever. In women, prior chronic kidney disease, lower left ventricular (LV) ejection fraction, higher LV wall motion score index, white blood cell count, peak creatine kinase-myocardial band level, and longer PCI duration were associated with fever after PCI. Procedures such as an intra-aortic balloon pump, extracorporeal membrane oxygenation, continuous renal replacement therapy, central and arterial line insertion, and cardiopulmonary resuscitation were related to fever after PCI. Fever after PCI in patients with AMI was associated with a higher incidence of MACE, all-cause death, CD, and any revascularization at the 2 years mark than in those without fever.