• Title/Summary/Keyword: wall motion

Search Result 593, Processing Time 0.023 seconds

Numerical Investigation of Deformation of Thin-walled Tube Under Detonation of Combustible Gas Mixture (가연성 연소 가스의 데토네이션에 의한 얇은 관 변형 모델링)

  • Gwak, Mincheol;Lee, Younghun;Yoh, Jai-Ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.11-19
    • /
    • 2015
  • We present the results of a multi-material numerical investigation of the propagation of a combustible gas mixture detonation in narrow metal tubes. We use an experimentally tuned one step Arrhenius chemical reaction and ideal gas equation of state (EOS) to describe stoichiometric $H_2-O_2$ and $C_2H_4-O_2$ detonations. The purely plastic deformations of copper and steel tubes are modeled using the Mie-Gruneisen EOS and Johnson-Cook strength model. To precisely track the interface motion between the detonating gas and the deforming wall, we use the hybrid particle level-sets within the ghost fluid framework. The calculated results are validated against the experimental data because the results explain the process of the generation and subsequent interaction of the expansion wave with the high-strain-rate deformation of the walls.

A rare type of single coronary artery with right coronary artery originating from the left circumflex artery in a child

  • Kim, Jong Min;Lee, Ok Jeong;Kang, I-Seok;Huh, June;Song, Jinyoung;Kim, Geena
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.1
    • /
    • pp.37-40
    • /
    • 2015
  • The presence of a single coronary artery is a rare congenital anomaly; such patients often present with severe myocardial ischemia. We experienced the case of a 13-year-old girl with the right coronary artery originating from the left circumflex artery. She visited our Emergency Department owing to severe chest pain; her cardiac enzyme levels were elevated, but her initial electrocardiogram (ECG) was normal. Echocardiography showed normal anatomy and normal regional wall motion. When she presented with recurrent chest pain on admission, the ECG showed significant ST-segment elevation in the left precordial leads and inferior leads with ST-segment depression in aVR lead, suggesting myocardial ischemia, and her cardiac enzyme levels were also elevated. We performed coronary angiography that showed a single right coronary artery originating from the left circumflex artery without stenosis. We confirmed the presence of a single coronary artery using coronary computed tomography. In addition, the treadmill test that was performed showed normal results. She was discharged from the hospital without any medications but with a recommendation of a regular followup.

The Performance Estimation of Rotor in Wind Fence by Rotor Analysis Solver based on Actuator Disk Model (Actuator Disk Model 기반의 로터 해석자를 사용한 방풍 구조물 내부의 로터 성능 예측)

  • Kim, Taewoo;Oh, Sejong;Kang, Hee Jung;Yee, Kwanjung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.6
    • /
    • pp.429-439
    • /
    • 2013
  • The purpose of current study is to develop the rotor analysis solver and perform a rotor aerodynamic analysis in the wind fence. To this end, the rotor analysis solver based on actuator disk model was employed. To consider the asymmetric effect of the rotor in the wind fence, the flapping motion analysis was conducted with blade element theory for the effective angle of attack calculation. The validation cases which are the rotor with wall and ground were accomplished by developed solver. The decrease of rotor performance by wind fence was confirmed. The wind fence configuration was suggested which guarantees more than 95% rotor performance compared with the no fence case.

Tailings Behavior and Performance of the Tailings Return Unit of the Head-feed Combine(II) -Theoretical and Experimental Analysis of Tailing Behavior- (자탈형(自脫型) 콤바인 환원장치(還元裝置)의 환원물(還元物) 유동현상(流動現象)과 환원성능(還元性能) 개선(改善)에 관한 연구(硏究)(II) -환원물(還元物) 유동(流動)의 이론해석(理論解析)과 실험분석(實驗分析)-)

  • Cho, Y.K.;Chung, C.J.;Choi, K.H.;Park, P.K.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.2
    • /
    • pp.133-141
    • /
    • 1991
  • This study was undertaken to investigate the structural and configurational characteristics of the tailings return-unit in the commercially available head-feed combines and to study the aero-dynamical behavior of the tailings in the units. The mathematical model of the motion of tailings in the thrower casing was developed and the simulated trajectories for different type of units was analyzed to compare with the measured ones. The air-stream velocity profile in various locations along the tailings returning duct was measured to find the effect of configurational characteristics and blade tip speed. The results of the study are summerized as follows. 1. The ejecting angle, which is the angle between the direction of the particle velocity ejecting from the blade and the horizontal axis, was found to be about $66^{\circ}$ in both the simulation and experiment. The angle was much greater than the setting angle of actual duct of the combines studied, which were $48{\sim}56^{\circ}$. By comparison of these results, it was suggested to change duct setting angle so as to reduce the frictional force, between the duct wall and tailings, by reducing the difference between the ejecting and setting angles. 2. The velocity of the air stream in the duct was in general higher in the upper bound of the duct compared to the lower and decreased as the stream went toward the end of duct. The comparison of the tailings units among the combines studied showed a superior performance with the tapered duct having small diameter in the outlet and with greater number of thrower blade.

  • PDF

The Effect of Ankle Kinesio Taping on Postural Control Functions in University Students: a randomized control trial (발목관절의 키네지오 테이핑 적용이 대학생들의 운동 수행 시 자세조절기능에 미치는 영향)

  • Eom, Se-Young;Lee, Won-Jun;Lee, Jae-Il;Lee, Eun-Hee;Lee, Hye-Young;Chung, Eun-Jung
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.1
    • /
    • pp.11-19
    • /
    • 2018
  • Purpose : The purpose of this study was to examine the effects of ankle kinesio taping on postural control function during exercise in university students. Method : Thirty subjects were randomly allocated to three groups: Y taping group (n=20), I taping group (n=20) and Non-taping group (n=20). All groups underwent the same exercise program including stretching for 30 minutes. The exercise program proceeded in the following order: five minutes of stretching, a 20-minutes exercise program, and additional five 5 minutes of stretching. Of the eight exercise methods suggested by Purcell et al, seven were chosen (lateral shuffle, forward & backward running, agility ladder, figure-of-8, forward jogging while jumping over cones, wall jumps and zigzags); $90^{\circ}$ cuts with lateral shuffle were omitted. The postural control functions was measured participants's perceptions of stability, confidence, and reassurance using methods suggested by Purcell et al,. Result : The confidence was significant difference in I taping group compared to Non taping group. The reassurance was significant difference in Y taping group and I taping group compared to Non taping group. Conclusion : The Kinesio taping increased confidence, and reassurance during exercise in university students. Additional research on Kinesio taping for improving range of motion and agility is need.

Experimental Studies on the Second Intermediate Host of Clonorchis sinensis I. Survey on the metacercariae of some trematodes in fresh-water shrimps and experimental infection of Palaemon spp. with Clonorchis cercariae (간흡충(肝吸蟲)의 제이중간숙주(第二中間宿主)에 관(關)한 연구(硏究) I. 민물 새우의 metacercaria 조사(調査) 및 간흡충(肝吸蟲) cercaria의 Palaemon spp.에 대(對)한 감염시험(感染試驗))

  • Rhee, Jae Ku
    • Korean Journal of Veterinary Research
    • /
    • v.9 no.1
    • /
    • pp.71-78
    • /
    • 1969
  • The present studies were undertaken to determine accurately whether Korean native fresh-water shrimps can serve as the second intermediate host of Clonorchis sinensis. The experimental results obtained were as follows; 1. Metacercaria of Clonorchis sinensis was not discovered in 36 Macrobranchium nipponensis (De Hann), 1992 Palaemon paucidens (De Hann) and Palaemon madestus Heller, and 860 Caridina leucastica Stimpson, collected in Kimhae district, which were digested in artificial gastric juice, using binocular dissecting microscope. 2. Cercariae of the Chinese liver fluke could not approach the body wall of young shrimps due to streaming caused by their motion. 3. Young Palaemon spp. of 247 were divided into two groups and placed in two different room aquariums, one is at high temperature, the other is normal. Then they were contacted with the cercariae. Only 11 degenerated metacercariae were found in 9 Palaemon spp. It was suggested that they had died immediately or within a few days after penetration. Furthermore the temperature did not affect the infective ratio. 4. At the field experimental aquarium, no metacercaria of Clonorchis sinensis was discovered tn 100 Palaemon spp. which had been brought into contact with 5000 Parafossarulus manchouricus two trials. 5. Specific changes in the cercariae mixed with the extract of shrimps meat were not observed through the dissecting microscope. 6. These results suggest that the Korean native shrimps cannot serve as the intermediate host of Clonorchis sinensis.

  • PDF

Pre-Service Elementary Teachers' Views on 'Action and Reaction': Focused on their Understandings and Typically-Perceived-Situations (TPS) (초등예비교사의 '작용과 반작용' 개념 -이해 정도와 전형적 인식상황 분석을 중심으로-)

  • Joung, Yong Jae
    • Journal of The Korean Association For Science Education
    • /
    • v.36 no.6
    • /
    • pp.851-866
    • /
    • 2016
  • The purpose of this study is to investigate pre-service elementary teachers' views of the law of action-reaction by examining their degrees of understanding and Typically-Perceived-Situations (TPS). Data were collected from 177 Grade 3 pre-service elementary teachers. The results of analyzing these data show: First, the participants did not sufficiently understand about the law of action-reaction, and their degrees of understanding were different depending on the situation provided in the questionnaire. Second, in relation to the TPSs of the law of action-reaction, the participants thought of irrelevant situations to the law of action-reaction such as "a situation generated by inertia" as well as commonly relevant ones such as "a person pushing a wall", and had somewhat biased TPSs in terms of 'action type' and 'result motion type' of action-reaction. Finally, several suggestions on the science education for promotion of understanding about the law of action-reaction were given.

A Case Report of Takotsubo Cardiomyopathy During Breast Augmentation (유방확대술 중 발생한 Takotsubo 심근병 1례)

  • Lee, Kyoung-Mook;Kim, Youn-Hwan;Kim, Jeong-Tae;Hwang, Won-Jung;Shin, Jin-Ho
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.85-88
    • /
    • 2011
  • Purpose: Takotsubo cardiomyopathy is a relatively uncommon type of stress-induced cardiomyopathy characterized by transient left ventricular regional wall motion abnormalities. Emotional and physical stresses play a key role in this type of cardiomyopathy in postmenopausal women. The current hypothesis is that the syndrome represents a form of catecholamine surge due to stress or epinephrine-mediated acute myocardial stunning. Methods: A 44-year-old woman had suffered premature ventricular contraction following a cardiogenic shock during a breast augmentation surgery under enflurane anesthesia and tumescent solution infiltration. She was treated with cardiopulmonary resuscitation at a local clinic. Then she was brought to the Emergency Department of the authors' hospital. Results: The woman's echocardiogram showed an ejection fraction of 20~25% with associated basal hyperkinesis and left ventricular apical ballooning. The patient was admitted to the ICU and required inotropic support for two weeks. The patient's condition dramatically improved, and her ejection fraction returned to 70%. Conclusion: It is believed that there were multiple triggering factors of the onset of Takotsubo cardiomyopathy in the woman's social and family history, including infiltration of a large volume of the tumescent solution and VPCs induced by enflurane anesthesia without premedication. The importance of careful history-taking, careful pre-operative consultation on psychological suffering especially for breast surgery, premedication before surgery, patient reassurance, and post-operative psychosocial and emotional assistance was again seen in this case.

Effect of the Inner Material and Pipe Geometry on the Flow and Induced Radiated Noise (파이프 내 흡음재 및 형상에 따른 유동 및 방사소음에 대한 수치해석적 연구)

  • Lee, Su-Jeong;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.423-430
    • /
    • 2014
  • Noise and vibration, which occur in a pipe, are usually caused by the interaction between the turbulent flow and nearby wall. Although it can be estimated by a simple case of expanded pipes having complex turbulent flow, the radiated noise is highly dependent upon the size, shape, and thickness of the given model. In addition, the radiated noise propagates and has serious interference and destabilization effects on the surrounding systems, which can lead to fatigue fracture and failure. This study took advantage of the variety of commercial programs, such as FLUENT (flow solver), NASTRAN (dynamic motion solver of complex structures) and VIRTUAL LAB (radiated noise solver) based on the boundary element method (BEM), to understand the underlying physics of flow noise. The expanded pipe has separation and a high pressure drop because of the abrupt change in the cross-section. Based on the radiated noise calculations, the noise level was reduced to around 20 dB in the range of 100-500 Hz.

The Magnetic Properties of FeBSiNb Alloy Ribbons with High Glass forming Ability (고 비정질 형성능을 가진 FeBSiNb 합금 리본의 자기적 특성)

  • Noh, Tae-Hwan;Kim, Gu-Hyun
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.4
    • /
    • pp.154-159
    • /
    • 2002
  • Amorphous FeBSiNb alloy ribbons having bulk glass forming ability and high saturation magnetic flux density were produced by single-roller melt spinning apparatus in the thickness range of 22∼102㎛. With the increase of thickness, the coercive force and squareness ratio decreased, while maximum permeability and AC permeability increased. However electrical resistivity was almost constant. Furthermore refined and complex magnetic domain structure was observed in thicker ribbons owing to the change in internal magnetic anisotropy. For the alloy with the thickness of 81㎛, small coercive force of 24 mOe and high effective permeability of 12,000 at 1㎑ were obtained, those are considered to be better comparing to the conventional soft magnetic amorphous alloys (∼20 ㎛). The good soft magnetic properties of the thick FeBSiNb amorphous alloys were attributed to the decrease in surface pinning effect during wall motion, appearance of perpendicular anisotropy and resulted domain refinement.