• Title/Summary/Keyword: wall inlet

Search Result 358, Processing Time 0.023 seconds

Numerical simulations on flow and particle behaviors in the upper part of a syngas cooler for IGCC (IGCC 합성가스 냉각기 상부의 열유동 및 입자거동 특성에 대한 전산해석 연구)

  • Park, Sangbin;Ye, Insoo;Ryu, Changkook;Kim, Bongkeun
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.147-148
    • /
    • 2012
  • The syngas produced from coal gasification is cooled down for gas cleaning by a syngas cooler that produces steam. Due to the presence of fly slag in the syngas, erosion, slagging and corrosion especially in the upper part of the syngas cooler may cause major operational problems. This study investigates the flow, heat transfer and particle behaviors in the syngas cooler of a 300MWe IGCC plant by using computational fluid dynamics. For various operational loads and geometry, the gas and particle flows directly impinged on the wall opposite to the syngas inlet, which may lead to erosion of the membrane wall. In the evaporate channels inside the syngas cololr, the particle flows were concentrated more on the outer channel where slagging becomes more serious. The heat transfer to the wall was mainly by convection which was larger on the side wall below the inlet level.

  • PDF

Numerical Analysis of Transitional Flow in a Stenosed Carotid Artery (협착된 경동맥내 천이 유동 수치 해석)

  • Kim, Dongmin;Hwang, Jinyul;Min, Too-Jae;Jo, Won-Min
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.1
    • /
    • pp.52-63
    • /
    • 2022
  • Direct numerical simulation of blood flow in a stenosed, patient-specific carotid artery was conducted to explore the transient behavior of blood flow with special emphasis on the wall-shear stress distribution over the transition region. We assumed the blood as an incompressible Newtonian fluid, and the vessel was treated as a solid wall. The pulsatile boundary condition was applied at the inlet of the carotid. The Reynolds number is 884 based on the inlet diameter, and the maximum flow rate and the corresponding Womersley number is approximately 5.9. We found the transitional behavior during the acceleration and deceleration phases. In order to quantitatively examine the wall-shear stress distribution over the transition region, the probability density function of the wall-shear stress was computed. It showed that the negative wall-shear stress events frequently occur near peak systole. In addition, the oscillatory shear stress index was used to further analyze the relationship with the negative wall-shear stress appearing in the systolic phase.

Spray combustion with high temperature air in a Gas Turbine Combustor (가스터빈 연소기내의 고온공기 분무연소 해석)

  • Jo, Sang-Pil;Kim, Ho-Young;Park, Sim-Soo
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.192-198
    • /
    • 2004
  • A numerical study was conducted to determine the effects of high temperature air, including equivalent ratio on flow field, temperature, evaporation, and overall temperature distribution in gas turbine combustor. A sector model of a typical wall jet can combustor, featuring introduction of primary air and dilution air via wall jet, was used in calculations. Flow field and temperature distribution were analyzed. Operating conditions such as inlet temperature and overall equivalent ratio were varied from 373 to 1300 K, and from 0.3 to 0.6, respectively, while any other operating conditions were fixed. The RNG ${\kappa}-{\varepsilon}$ model and eddy breakup model were used for turbulence and combustion model respectively. It was found that the increase with the inlet air temperature, velocity in the combustor is accelerated and evaporation of liquid fuel is not affected in primary zone, high temperature inlet air enhances the evaporation and improves overall temperature distribution factor.

  • PDF

Numerical Analysis on the Gas Flows in MOCVD Reactor for the Growth of GaN Epitaxy (GaN 에피층 성장을 위한 MOCVD 반응로의 가스 유동에 관한 수치해석)

  • Shin, C.Y.;Baek, B.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.770-775
    • /
    • 2001
  • Numerical calculation has been performed to investigate the fluid flow, heat transfer and local mass fraction of chemical species in the MOCVD (metalorganic chemical vapor deposition) manufacturing process. The mixing of reactants (trimethylgallium with hydrogen gas and ammonia) was presented by the concentration of each reactants to predict the uniformity of film growth. Effects of inlet size, location, mass flow rate and susceptor/cold wall tilt angle on the concentration were reported. The newly developed reactor, that precursors were supplied at separated inlet to prevent from premixing, was investigated to obtain the quantitative verification. As a results, the optimum mass flow rate, wall tilt angle and inlet conditions were proposed.

  • PDF

Optimization of Pine Flavor Microencapsulation by Spray Drying

  • Lee, Shin-Jo;Lee, Yang-Bong;Hong, Ji-Hyang;Chung, Jong-Hoon;Kim, Suk-Shin;Lee, Won-Jong;Yoon, Jung-Ro
    • Food Science and Biotechnology
    • /
    • v.14 no.6
    • /
    • pp.747-751
    • /
    • 2005
  • Microencapsulation of pine flavors was investigated to determine the optimum wall material and spray drying condition. ${\beta}$-Cyclodextrin, maltodextrin, and a 3:1 mixture of maltodextrin and gum arabic were evaluated as wall materials. The latter mixture was determined to be the best wall material based on dispersion capacity and flavor yield. Spray drying effectiveness was evaluated using a $3^3$ fraction factorial design and statistical analysis. The optimum operation condition was an inlet air temperature of $175^{\circ}C$, inlet airflow rate of $0.65\;m^3/min$ and atomizing pressure of 180 kPa, which resulted in a 93% flavor yield. The best particle shape observed by SEM was a round globular shape obtained under the above spray drying condition, whereas lower temperatures and higher inlet airflow rates resulted in initial and full collapses, respectively. The round globular shapes remained stable for at least one month.

Transmission Loss Analysis of Simple Expansion Chambers with Multiple Inlets and Outlets (다입력/다출력관을 갖는 확장관의 투과손실 해석)

  • 박기춘;김양한
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.807-813
    • /
    • 1998
  • Transmission loss of the simple expansion chamber with multiple inlet and outlet ports is obtained. Transfer matrices which represent the relation between the power variables(pressure and velocity) of inlets and outlets depend on the input relatons as well as the acoustic system parameters(i.e. geometry of the chamber, wall admittance, etc.). The analysis has been performed analytically, including the effects of higher order modes for the 2-inlet/1-outlet, 1-inlet/2-outlet and 2-inlet/2-outlet systems. This study yeilds that phase difference between the inlet ports can significantly increase the transmission loss in low frequency range.

  • PDF

SUPERSONIC INLET BUZZ CONTROL USING CORRECTED BLEED MODEL (보정한 Bleed 모델을 이용한 초음속 흡입구 버즈 제어)

  • Kwak, E.;Lee, S.
    • Journal of computational fluids engineering
    • /
    • v.18 no.4
    • /
    • pp.82-89
    • /
    • 2013
  • Database of a bleed model has been corrected and numerical simulations have been performed to control buzz using the corrected bleed model. The existing bleed model, which was developed as a part of a boundary condition model for porous bleed walls, underestimates bleed flow rate because flow accelerations near the bleed regions are ignored. Also, it overpredicts the sonic flow coefficient when the bleed plenum pressure ratio is high. To correct these problems, and to enhance the performance of the bleed model, the database has been corrected using CFD simulations to compensate for the flow acceleration near the bleed region. Futhermore, the database of the bleed model is extended with the second order extrapolation. The corrected bleed model is validated with numerical simulations of a shock-boundary layer interaction problem over a solid wall with a bleed region. Using the corrected bleed model, numerical simulations of supersonic inlet buzz are performed to find the deterrent effects of bleed on buzz. The results reveal that bleed is effective to prevent buzz and to enhance the inlet performance.

The Survey for Ventilation Systems of Weaned Pig House in Korea (국내 이유자돈사 환기시설 실태 조사)

  • Lee, Jun-Yeob;Jeon, Jung-Hwan;Song, Jun-Ik
    • Journal of Animal Environmental Science
    • /
    • v.20 no.1
    • /
    • pp.9-14
    • /
    • 2014
  • This survey was conducted to give the basic information for ventilation systems of weaned pig house to establish the acceptable ventilation system in Korea. A total of 11 farms were surveyed in this study and 1 more farm in each province was regionally selected. The general information, inlet and outlet ventilation system, alley in house, space allowance of weaned pigs and manure management were surveyed. Space allowance of weaned pig in 82% of surveyed farms met the legal standard. Side wall inlet and outlet ventilation system were 82% and 73% of surveyed farms, respectively. Moreover, 73% farms have alley in the pig house to control temperature of inlet air. In this survey, both planar slot and circular duct inlet system and side wall fan outlet system could be a favorable ventilation system in weaned pig house.

Temperature Distribution of an Air-Cooled PCB Mounted with Finned and Finnless Modules (휜이 부착된 강제 공랭 모듈을 실장한 기판의 온도분포에 관한 연구)

  • Shin, D.J.;Park, S.H.;Lee, I.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.624-629
    • /
    • 2001
  • An experimental study was performed to investigate adiabatic wall temperature and heat transfer coefficient around on a module with longitudinal fin heat sink cooled by forced air flow. In the first method, inlet air flow(1-7m/s) and input power(3-5W) was varied after a heated module were placed on an adiabatic floor($320{\times}550{\times}1mm^{3}$). An adiabatic wall temperature was determinated to use liquid crystal film(LCF). In the second method to determinate heat transfer coefficient, inlet air flow(1-7m/s) and the heat flux of rubber heater($0.031-0.062\;W/cm^{2}$) was varied after an adiabatic module was placed on rubber heater covering up an adiabatic floor. In addition, surface oil-film visualization were performed to characterize the macroscopic flow-field around a module.

  • PDF

Mathematical analysis on thermal regeneration of ceramic monolith filter in diesel engine (CI기관에서 세라믹 모노리스 필터의 열재생에 관한 수학적 해석)

  • 강호인;조재명;한영출
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.60-66
    • /
    • 1992
  • This study describes a theoretical analysis for the wall temperature of ceramic filter trap and pressures of inlet and outlet channel in the filter trap. In this study, the maximum wall temperature through filter trap length with time during the regeneration period showed a tendency moving from forward to backward. The pressure change of filter trap increased at the initial combustion but decreased with the combustion to be activated. So the pressure difference between initial and end regeneration at the inlet channel showed about 2kPa. The thermal regeneration period of this filter trap in the theoretical analysis showed about 200seconds in which the wall temperature was similar to the case of initial condition and the pressure showed about 1 kPa.

  • PDF