• 제목/요약/키워드: wall height

검색결과 897건 처리시간 0.021초

Experimental study on effect of underground excavation distance on the behavior of retaining wall

  • Lee, Seok-Won
    • Geomechanics and Engineering
    • /
    • 제17권5호
    • /
    • pp.413-420
    • /
    • 2019
  • The changes in earth pressure and ground settlement due to underground excavation near an existing retaining wall were studied experimentally according to the separation distance between the underground excavation and the retaining wall. In addition, this study attempted to experimentally prove that the arching phenomenon occurred during the construction of the underground space. A model tank having 120 cm in length, 160 cm in height, and 40 cm in width was manufactured to simulate underground excavation through the use of five separated base wall bodies. The variation of earth pressure on the retaining wall was measured according to the underground excavation phase through the use of 10 separated right wall bodies. The results showed that the earth pressure on the retaining wall was changed by the lowering of the first base bottom wall; however, the earth pressure was not changed significantly by the lowering of the third base bottom wall, since the third base wall had sufficient separation distance from the retaining wall. Lowering of the first base wall induced a decrease in the earth pressure in the lower part of the retaining wall; in contrast, lowering of the first base wall induced an increase in the earth pressure in the middle part of the retaining wall, proving the arching effect experimentally. It is necessary to consider the changes in earth pressure on the retaining wall in designing earth retaining structures for sections where the arching effect occurs.

3차원 수치해석에 의한 표준트럭하중에 의해 옹벽에 작용하는 수평토압의 등가높이 산정 (Assessment of Equivalent Heights of Soil for the Lateral Earth Pressure Against Retaining Walls Due to Design Truck Load by 3D Numerical Analysis)

  • 서승환;진현식;김동욱;정문경
    • 한국지반신소재학회논문집
    • /
    • 제18권4호
    • /
    • pp.75-85
    • /
    • 2019
  • 차량하중에 의해 옹벽에 전달되는 수평토압은 등가상재하중높이로 표현하며, 표준트럭의 축하중 크기와 위치에 따라 그 영향이 달라진다. 한계상태설계법은 2015년부터 국내 도로교 설계에 적용되어 왔다. 하지만 우리나라 실정을 고려한 토압하중계수(등가상재하중높이)가 제시되어 있지 않아 설계에 적용하는데 어려움이 있다. 본 연구에서는 국내 표준트럭의 축하중 크기 및 위치를 반영한 등가상재하중높이를 산정하였다. 3차원 수치해석 방법으로 등가상재하중높이를 산정하였으며, AASHTO 기준치와 차별화된 등가상재하중 높이를 제시하였다. 우리나라 표준트럭의 축하중은 미국과 달리 축하중이 집중되는 구조를 가지고 있어 옹벽의 높이가 낮은 경우 등가상재하중높이가 AASHTO에서 제안한 값보다 다소 크게 평가 되었다. 따라서 우리나라 교통하중으로부터 도출된 등가상재하중높이는 옹벽 구조물의 장기 안정성을 확보하는 측면에서 AASHTO 기준치보다 보수적으로 제시하는 것이 합리적일 것이다.

양측면 수축/확대 사각채널에서 한면에 설치된 리브의 각도가 열성능에 미치는 효과 (Effect of Rib Angle on Thermal Performance in a Two Wall Convergent/Divergent Channel with Ribs on One Wall)

  • 안수환;이명성;배성택
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.195-200
    • /
    • 2015
  • The thermal performance in the channels with two-wall rectangular convergent/divergent cross-sectional areas along the axial distance was investigated experimentally. The ribbed rectangular convergent/divergent channels were manufactured with a fixed rib height (e) = 10 mm and the ratio of rib spacing (p) to height (e) = 10. Three different parallel angled ribs (a = $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$) were each placed on the channel's one sided wall only. The convergent channel of $D_{ho}/D_{hi}=0.67$ and the divergent channel of $D_{ho}/D_{hi}=1.49$ were considered. The ribbed divergent channel produced better thermal performance than the ribbed convergent channel in three different restrictions; identical flow rate, identical pumping power, and identical pressure loss.

펌프 섬프장 흡입 조건에 따른 자유표면 보텍스 변동에 관한 연구 (A Study on the Change of Free Surface Vortex according to Intake Conditions in the Pump Sump)

  • 박영규;이규명;최윤환;이연원
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.74-79
    • /
    • 2011
  • In this study the change of free surface vortex is represented at different times according to height of water and with or without curtain wall installation. The air volume fraction is investigated at each condition of water level and the influence about creation of vortex is analyzed. The height of sump intake is taken as 100mm and the water level is divided into 5 steps. The sump model is the TSJ model and the curtain wall is applied by HI standard of America. The results shows that the free surface vortex can be identified on the isotropic surface at air volume fraction 1%~5% and the vortices make an air column from the free surface to the sump intake and are created and destroyed repeatedly. In the higher water level, less air is absorbed into the intake pipe. After curtain wall installation, the suction rate of the air volume fraction is decreased by 6.7%. The result of the vortex motion according to time, works on a cycle.

돌출높이와 초기온도 변화에 따른 연소실 벽면에서의 열유속에 관한 연구 (A Study of Heat Flux According to the Initial Temperature of Combustion Chamber and Blight of Probe in a Constant Volume Combustion Chamber)

  • 이치우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1055-1062
    • /
    • 2004
  • As for the Production of internal combustion engines there has been further movement toward development of high Performance engines with improved fuel efficiency as well as a lightweight and a small size. These tendencies help to solve the problems in engines for example, such as thermal load. abnormal combustion and so on. In order to investigate these Problems, a thin film-type probe for measuring instantaneous temperature has been suggested. A method for manufacturing such a probe was established in this study The instantaneous surface temperature of a constant volume combustion chamber was measured by using this probe and the heat flux was obtained through Fourier analysis In order to thoroughly understand the characteristics of combustion. authors measured wall temperature of combustion chamber and calculated heat flux through a cylinder wall while varying the protrusion height of probe. For these Purposes, the instantaneous surface temperature probe was developed. thereby making possible the analysis of instantaneous temperature of wall surface and the detection of unsteady heat flux in the constant volume combustion chamber.

안정해석을 통한 공동 일체식 옹벽의 최적높이 평가 (Evaluation on Optimal Height of the Bin Wall using Stability Analysis)

  • 배우석
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.48-54
    • /
    • 2009
  • Structures to support against slop failures or resist earth pressure like masonry retaining walls or retaining walls have continued to advance and evolve to new eco-friendly, easy-to-construct, crib retaining walls with varied forms and construction methods, meeting the needs of the times. Researches until now, however, have focused on the analyses of site displacement or stability of the whole site including structures like retaining walls, and thus, researches on rational design or method for stability analysis are lacking. Therefore, this study was conducted on a number of stability analyses, such as the visual power line or stability on sliding, being presented for bin walls, which enable vegetation to grow and were developed and applied in varied forms, meeting the development demands for eco-friendly retaining wall structures. This study compared the results of stability analyses, determined their feasibility, and evaluated their stability according to the height and facade slope of retaining walls. According to the results of this study, traditional masonry retaining wall analysis showed rather conservative stability evaluation results in the stability evaluation of bin walls, and the method using the visual power line seems to be objective because it produced similar results to the stability evaluation method on sliding or turnover.

Study on the Unsteady Wakes Past a Square Cylinder near a Wall

  • Kim Tae Yoon;Lee Bo Sung;Lee Dong Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제19권5호
    • /
    • pp.1169-1181
    • /
    • 2005
  • Experimental and numerical studies on the unsteady wake field behind a square cylinder near a wall were conducted to find out how the vortex shedding mechanism is correlated with gap flow. The computations were performed by solving unsteady 2-D Incompressible Reynolds Averaged Navier-Stokes equations with a newly developed ${\epsilon}-SST$ turbulence model for more accurate prediction of large separated flows. Through spectral analysis and the smoke wire flow visualization, it was discovered that velocity profiles in a gap region have strong influences on the formation of vortex shedding behind a square cylinder near a wall. From these results, Strouhal number distributions could be found, where the transition region of the Strouhal number was at $G/D=0.5{\sim}0.7$ above the critical gap height. The primary and minor shedding frequencies measured in this region were affected by the interaction between the upper and the lower separated shear layer, and minor shedding frequency was due to the separation bubble on the wall. It was also observed that the position (y/G) and the magnitude of maximum average velocity $(u/u_{\infty})$ in the gap region affect the regular vortex shedding as the gap height increases.

Closed-form and numerical solution of the static and dynamic analysis of coupled shear walls by the continuous method and the modified transfer matrix method

  • Mao C. Pinto
    • Structural Engineering and Mechanics
    • /
    • 제86권1호
    • /
    • pp.49-68
    • /
    • 2023
  • This study investigates the static and dynamic structural analysis of symmetrical and asymmetrical coupled shear walls using the continuous and modified transfer matrix methods by idealizing the coupled shear wall as a three-field CTB-type replacement beam. The coupled shear wall is modeled as a continuous structure consisting of the parallel coupling of a Timoshenko beam in tension (with axial extensibility in the shear walls) and a shear beam (replacing the beam coupling effect between the shear walls). The variational method using the Hamilton principle is used to obtain the coupled differential equations and the boundary conditions associated with the model. Using the continuous method, closed-form analytical solutions to the differential equation for the coupled shear wall with uniform properties along the height are derived and a numerical solution using the modified transfer matrix is proposed to overcome the difficulty of coupled shear walls with non-uniform properties along height. The computational advantage of the modified transfer matrix method compared to the classical method is shown. The results of the numerical examples and the parametric analysis show that the proposed analytical and numerical model and method is accurate, reliable and involves reduced processing time for generalized static and dynamic structural analysis of coupled shear walls at a preliminary stage and can used as a verification method in the final stage of the project.

분무액적과 벽의 상호작용에 대한 연구 (Study of Spray Droplet/Wall Interaction)

  • 양희천;유홍선;정연태
    • 한국자동차공학회논문집
    • /
    • 제6권4호
    • /
    • pp.86-100
    • /
    • 1998
  • The impingement of the fuel spray on the wall within the combustion chamber in compact high-pressure injection engines and on the intake port wall in port-fuel-inje- ction type engines is unavoidable. It is important to understand the characteristics of impinging spray because it influences on the rate of fuel evaporation and droplet distrib- ution etc. In this study, the numerical study for the characteristics of spray/wall interaction is performed to test the applicability and reliability of spray/wall impingement models. The impingement models used are stick model, reflect model, jet model and Watkins and Park's model. The head of wall-jet eminating radilly outward from the spray impingement site contains a vortex. Small droplets are deflected away from the wall by the stagnation flow field and the gas wall-jet flow. While the larger droplets with correspondingly higher momentum are impinged on the wall surface and them are moved along the wall and are rolled up by wall-jet vortex. Using the Watkins and Park's model the predicted results show the most reasonable trend. The rate of increase of spread and the height of the developing wall-spray is predicted to decrease with increased ambient pressure(gas density).

  • PDF

압밀주입에 의한 지반개량 특성고찰 (The Evaluation on Behavior of Segmental Grid Retaining Wall by Model Test)

  • 김상수;배우석;이종규
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.162-171
    • /
    • 2006
  • Segmental Grid Retaining Wall is one of the segmental grid retaining walls using headers and stretchers to establish the framework of the wall In this method, grids formed by the intersection of headers and stretchers are generally filled with the gravel to maintain the weight of the wall Therefore, the construction can be carried out with higher speed and much economically when compared with the concrete retaining wall Furthermore, it has high drain capacity, and environmentally friendly aspects also have been pointed out because the possibility of the planting at the front of the wall However, in the segmental grid retaining wall method, the relative movement between the individual headers and stretchers was generally recognized, and stress redistribution in the gravel filling was also observed when subjected to the external loading and self-weight of filling Therefore, it has been thought that the distribution of the earth pressure in the segmental grid retaining wall system differ from that of the concrete retaining wall In this study, the surcharge tests using the scaled model segmental grid retaining wall was carried out to observe the distribution of the earth pressure in the segmental grid retaining wall The earth pressure was measured in the six specified height of wall, and the distribution of the pressure was analyzed. Furthermore, the earth pressure by computation or by the test using the concrete retaining wall was also considered to make comparison

  • PDF