• Title/Summary/Keyword: wall displacement

Search Result 791, Processing Time 0.029 seconds

A Study on Assessment of Composite Couplings for Helicopter Rotor Blades with Multi-cell Sections

  • Jung, Sung-Nam;Park, Il-Ju;Shi, Eui-Sup;Chopra, Inderjit
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • In this work, a closed-form analysis is performed for the structural response of coupled composite blades with multi-cell sections. The analytical model includes the effects of shell wall thickness, transverse shear, torsion warping and constrained warping. The mixed beam approach based on Reissner's semi-complementary energy functional is used to derive the beam force-displacement relations. The theory is validated against experimental test data and other analytical results for coupled composite beams and blades with single-cell box-sections and two-cell airfoils. Correlation of the present method with experimental results and detailed finite element results is found to be very good.

The Characteristics of Piezoelectric Strian Constants on PNN-PZ-PT Ceramics (PNN-PZ-PT계 세라믹스의 압전변위특성)

  • 정수태;남효덕;조상희
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.6
    • /
    • pp.802-810
    • /
    • 1989
  • The temperature dependence of piezoelectric strain constant and the electric field induced strain are investigated as a function of PT in 0.5[xPT-(1-x)PZ]-0.5PNN ceramics. The piezoelectric strain constant d31 has the highest value(360$\times$10-12m/V) at PT=0.68. The temperature dependence of d31 is improved as Curie temperature of sample is increased, and the electric field dependence of induced strain is decreased with the coercive field increased. This ceramic system shows both piezoelectric effect and electrostrictive effect under the applied electric field. The piezoelectric of tetragonal phase is higher than that of rhombohedral phase, and the magnitude of electrostrictive constant is appeared in the order of morphotropic, rhombohedral and tetragonal phase. The piezoelectric strain constant with applied field must be considered theelectrostrictive effect due to 90$^{\circ}$domain wall displacements, and the displacement of bimorph type actuator agrees with the calulated value well.

  • PDF

Effects of Intake Port Swirl and Fuel Injection System on the Performance and Exhaust Emissions in a Turbocharged DI Diesel Engine (터보 차져 DI 디젤엔진에 있어서 성능 및 배기배출물에 미치는 흡기 포트 선회 유동 및 연료 분사계의 성능)

  • Yoon, Jun-Kyu;Cha, Kyung-Ok
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.45-53
    • /
    • 2005
  • The purpose of this study is to analyze that intake port swirl and fuel injection system have an effect on the engine performance in a turbocharged D.I. diesel engine of the displacement 9.4L. As result of steady flow test, when the valve eccentricity ratio moved to cylinder wall, the flow coefficient and swirl intensity is increased. And as the swirl is increased, the mean flow coefficient is decreased, whereas the Gulf factor is increased. Through this engine test, it can be expected to meet performance and emissions by the following applied parameters; the swirl ratio is 2.43, injection timing is BTDC 13oCA and compression is 15.5.

  • PDF

Analysis of Effects of Stiffness Increment Factors for Deciding the Initial Structural System of Tall Buildings (초고층건물 초기 구조시스템 선정을 위한 강성증가요인 효과 분석)

  • Lee, Jae-Cheol;Jung, Jong-Hyun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.857-862
    • /
    • 2007
  • The purpose of this research is to compare the stiffness increment effects with the floor plan shapes by the stiffness increment factors. For this, we generated the standard floor plans with Box and T type shapes. Then applied the stiffness increment factors -outrigger, material strength, member section- to those floor plans, and generated several alternative analysis models that make the effects of the factors to the lateral displacement exposed. Finally, we analyzed the stiffness increment effects and compared with each other by the stiffness increment factors. As a result, we found that the increment effects have not influence to floor plan shapes, and orders of stiffness increment effects are outrigger, core wall and material strength. We expect that the results of this study could be effectively utilized in the schematic structural design of tall buildings.

  • PDF

Applications of BOTDR fiber optics to the monitoring of underground structures

  • Moffat, Ricardo A.;Beltran, Juan F.;Herrera, Ricardo
    • Geomechanics and Engineering
    • /
    • v.9 no.3
    • /
    • pp.397-414
    • /
    • 2015
  • Three different applications for monitoring displacements in underground structures using a BOTDR-based distributed optical fiber strain sensing system are presented. These applications are related to the strain measurements of (1) instrumented PVC tube designed to be attached to tunnel side wall and ceiling as a sensor; (2) rock bolts for tunnels; and (3) shotcrete lining under loading. The effectiveness of using the proposed strain sensing system is evaluated by carrying out laboratory tests, in-situ measurements, and numerical simulations. The results obtained from this validation process provide confidence that the optical fiber is able to quantify strain fields under a variety of loading conditions and consequently use this information to estimate the behavior of rock mass during mining activity. As the measuring station can be located as far as 1 km of distance, these alternatives presented may increase the safety of the mine during mining process and for the personnel doing the measurements on the field.

Shaking table experiment on a steel storage tank with multiple friction pendulum bearings

  • Zhang, Ruifu;Weng, Dagen;Ge, Qingzi
    • Structural Engineering and Mechanics
    • /
    • v.52 no.5
    • /
    • pp.875-887
    • /
    • 2014
  • The aim of the shaking table experiment is to verify the isolation effect of a storage liquid tank with multiple friction pendulum bearings. A 1:20 scale model of a real storage liquid tank that is widely used in the petroleum industry was examined by the shaking table test to compare its anchored base and isolated base. The seismic response of the tank was assessed by employing the time history input. The base acceleration, wave height and tank wall stress were used to evaluate the isolation effect. Finally, the influences of the bearing performance that characterizes the isolated tank, such as the friction force and residual displacement, were discussed.

Static Performance of Reinforced Soil Segmental Retaining Wall (블록식 보강토 옹벽의 정적성능 평가)

  • Koh Tae-Hoon;Lee Sung-Hyuck;Lee Jin-Wook;Hwang Seon-Keun;Park Sung-Hyun;Lee Seung-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.46-52
    • /
    • 2003
  • In this study, the full scale testing method of the geogrid-reiuorced soil Segmental Retaining Walll(SRW) under the simulated train loading were proposed in order to evaluate the applicability of reinforced soil SRW in railway embankment. The train loading was simulated by the design static wheel load and the impact coefficient due to the train passing velocity. This test was focused on the static performance of reinforced soil SRW in terms of the following measuring systems ; the horizontal earth pressure displacement acting on the facing block and the tensile strain along the geogrid. The data gathered from this full scale testing was compared with numerical analysis results by FLAC.

  • PDF

A Case Study on The Stability and Reinforcement Method at a Rock Slope (암반사면의 안정성검토 및 보강방안에 관한 사례연구)

  • Chun, Byung-Sik;Lee, Seung-Eun;Kong, Jin-Young;Lim, Joo-Heon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1369-1375
    • /
    • 2006
  • This study analyzes stability and the reason of slope failure about cut slope on stony mountain in Acheondong, Guri and suggests the reasonal reinforce method. Based on the results of the subsurface exploration, laboratory tests, and the numerical analysis of finite element method, the potentials of plane and wedge failure are highly estimated. The safety factor was 1.2 under dry and 1.06 wet condition. The most proper reinforce method to raise the safety factor more than 1.5 was the way to control displacement by using step retaining wall, earth anchor, wire mesh, and rock anchor.

  • PDF

Effect of soil flexibility on bridges subjected to spatially varying excitations

  • Li, Bo;Chouw, Nawawi
    • Coupled systems mechanics
    • /
    • v.3 no.2
    • /
    • pp.213-232
    • /
    • 2014
  • Pounding is a major cause of bridge damage during earthquakes. In an extreme situation, it can even contribute to the unseating of bridge girders. Long-span bridges will inevitably experience spatially varying ground motions. Soil-structure interaction (SSI) may play a significant role in the structural response of these structures. The objective of this research is to experimentally investigate the effect of spatially varying ground motions on the response of a three-segment bridge considering SSI and pounding. To incorporate SSI, the model was placed on sand contained in sandboxes. The sandboxes were fabricated using soft rubber in order to minimise the rigid wall effect. The spatially varying ground motion inputs were simulated based on the New Zealand design spectra for soft soil, shallow soil and strong rock conditions, using an empirical coherency loss function. The results show that with pounding, SSI can amplify the pier bending moments and the relative opening displacements.

A Study on Stress Concentration Phenomena in Cylindrical Structures due to Stractural Incontinuty by Finite Element Method (構造的 不連續에 기인하는 圓筒構造物의 應力集中現象에 관한 有限要素法에 의한 硏究)

  • Kim, Doo-Man;Chung, Sei-Heon
    • Journal of the Korean Society of Safety
    • /
    • v.3 no.2
    • /
    • pp.25-34
    • /
    • 1988
  • The stress concentration phenomena due to the structural incontinuty are studied by finite element method. In this study, a circular cylinder is treated. Under the axial load, the membrance action is dominate and the 24 D.O.F. cylindrical membrane finite element is used. The assembly of this element can successfully represent the original structure geometrically. The internal displacement function is such organized that the inter element compatibility condition is fully satisfied. In this study, the stress concentration factors due to the presence of a hole on the cylinder wall are obtained, and the factors versus the location of the hole is computed and plotted. It is found that the hole effect on the stress concentration disappears beyond the neighboring region of the hole size form the edge of the hole. Those results are useful for practical design in determining the region where the re-inforcing is necessary.

  • PDF