• Title/Summary/Keyword: wall boundary

Search Result 1,048, Processing Time 0.029 seconds

Numerical Study of Laminar Flow over a Protruding Surface (I) - Flow Analysis - (돌출된 표면 위의 충류유동에 대한 전산 해석적 연구 (I) -유동 해석-)

  • Hwang, Jong-Yeon;Yang, Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1418-1425
    • /
    • 1999
  • Flow over a protruding surface is investigated using numerical simulation. We consider flow between two parallel plates with a cube mounted on one side of the channel. As the flow approaches the cube, the adverse pressure gradient produces three-dimensional boundary-layer separation, resulting In the formation of horseshoe vortices. The objective of our study is to clarify both the steady and the unsteady characteristics of the vortex system. As the Reynolds number increases, the structure of the vortices near the cube becomes complex and the number of vortices increases. The distribution of skin friction on the cube-mounted wall reflects the effect of the horseshoe vortices. All these results are consistent with the experimental findings currently available.

Effect of various boundary conditions and geometries in steam reformer using numerical analysis (수치해석을 이용한 수증기 개질 반응기의 다양한 경계조건 및 형상의 영향)

  • Park, Joon-Guen;Lee, Shin-Ku;Lim, Sung-Kwang;Bae, Joong-Myeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.41-44
    • /
    • 2007
  • Steam reforming reaction of natural gas is an important process for fuelcell commercialization. In this paper, steam reforming reaction is studied by numerical method. Pseudo-homogeneous model is incorporated for chemical reactions and one medium approach is used to take into account thermally equilibrium phenomena between catalyst and bulk gas. The model is validated with our experimental results under the same operating conditions. Because performance of reformer has relation to heat flux from wall, heat flux profiles was investigated by using Nusselt number. Value of Nusselt number in steam reformer is larger than one in channel, which does not have chemical reaction because steam reforming reaction is an endothermic reaction. When the difference of Nusselt number at the front and the rear is larger, performance is improved.

  • PDF

A Study of Flow Induced Noise for Multilevered Cylinder due to Turbulent Boundary Layer (난류경계층에 의한 다층재질 원통형 실린더의 유체소음 해석 연구)

  • 신구균;홍진숙;이헌곤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.271-276
    • /
    • 1994
  • 본 연구에서는 외부 호스, 내부 충진유 및 탄성체 핵으로 구성된 다층 재질의 무한히 긴 원통형 실린더가 자유 흐름 중에 있을 때, 유체 유동에 의한 난류 경계층내 벽면 압력 변동(wall pressure fluctuation)이 내부 탄성체 핵의 표면에 미치는 영향을 분석하기 위하여 난류 경계층에 의한 다층 재질의 실린더 내부 압력 변동 해석 이론을 정립하였다. 본 해석 이론에서는 파동 방정식을 이용하여 외부 호스 벽면 압력에 대한 전달 함수를 도출하고, 난류 경계층내 벽면 압력 변동은 Corcos Model을 기초로 하여 Strawderman이 제안한 실험식을 사용하여 추정하였다. 또 이를 바탕으로 자유 흐름 속도 변화등에 따른 실린더 내부 압력변도의 변화를 분석하여 보았다.

  • PDF

Numerical Study of Three-Dimensional Compressible Flow Structure Within an S-Duct for Aircraft Engine Inlet

  • Cho, Soo-Yong;Park, Byung-Kyu
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.1
    • /
    • pp.36-47
    • /
    • 2000
  • Three-dimensional compressible turbulent flow fields within the passage of a diffusing S-duct have been simulated by solving the Navier-Stokes equations with SIMPLE scheme. The average inlet Mach number is 0.6 and the Reynolds number based on the inlet diameter is $1.76{\times}10^6$ The extended $k-{\varepsilon}$ turbulence model is applied to modeling the Reynolds stresses. Computed results of the flow in a circular diffusing S-duct provide an understanding of the flow structure within a typical engine inlet system. These are compared with experimental wall static-pressure, total-pressure fields, and secondary velocity profiles. Additionally, boundary layer thickness, skin friction values, and streamlines in the symmetric plane are presented. The computed results depict the interaction between the low energy flow by the flow separation and the high energy flow by the reversed duct curvature. The computed results obtained using the extended $k-{\varepsilon}$ turbulence model.

  • PDF

Elevator Recognition and Position Estimation based on RGB-D Sensor for Safe Elevator Boarding (이동로봇의 안전한 엘리베이터 탑승을 위한 RGB-D 센서 기반의 엘리베이터 인식 및 위치추정)

  • Jang, Min-Gyung;Jo, Hyun-Jun;Song, Jae-Bok
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.1
    • /
    • pp.70-76
    • /
    • 2020
  • Multi-floor navigation of a mobile robot requires a technology that allows the robot to safely get on and off the elevator. Therefore, in this study, we propose a method of recognizing the elevator from the current position of the robot and estimating the location of the elevator locally so that the robot can safely get on the elevator regardless of the accumulated position error during autonomous navigation. The proposed method uses a deep learning-based image classifier to identify the elevator from the image information obtained from the RGB-D sensor and extract the boundary points between the elevator and the surrounding wall from the point cloud. This enables the robot to estimate the reliable position in real time and boarding direction for general elevators. Various experiments exhibit the effectiveness and accuracy of the proposed method.

Wind pressure measurements on a cube subjected to pulsed impinging jet flow

  • Mason, M.S.;James, D.L.;Letchford, C.W.
    • Wind and Structures
    • /
    • v.12 no.1
    • /
    • pp.77-88
    • /
    • 2009
  • A pulsed impinging jet is used to simulate the gust front of a thunderstorm downburst. This work concentrates on investigating the peak transient loading conditions on a 30 mm cubic model submerged in the simulated downburst flow. The outflow induced pressures are recorded and compared to those from boundary layer and steady wall jet flow. Given that peak winds associated with downburst events are often located in the transient frontal region, the importance of using a non-stationary modelling technique for assessing peak downburst wind loads is highlighted with comparisons.

Electrical and optical characteristics AZO transparent conductivity thin films by solid state diffusion method (고상확산법에 의해 제조된 AZO 투명전도막의 전기-광학특성)

  • Lim, Kwang-Soo;Pyo, Jin-Gu;So, Soon-Jin;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.785-787
    • /
    • 2002
  • Conductivity and transmittancy of ZnO is very excellent and the price is low. So the study of transparent electrode materials and electromagnetic wave shielding wall is actively in progress. We add $Al_2O_3$(0.0, 2.0, 3.0, 5.0wt%) to ZnO and observe microscopic structure and conductivity. For XRD observation, Al peak of AZO is increased by increasing the amount of $Al_2O_3$. We observe that the size of grain is reduced by increasing the liquid phase of grain boundary to SEM observation. Conductivity of AZO is increased by increasing the amount of $Al_2O_3$. We confirm the application possibility of the materials for electromagnetic wave reflection materials.

  • PDF

Characteristics of Fluid Flow and Heat Transfer in a Fluidized Bed Heat Exchanger (순환유동층 열교환기내 유동과 열전달 특성)

  • 안수환;이병창;김원철;이윤표
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.315-323
    • /
    • 2002
  • The commercial viability of heat exchanger is mainly dependent on their long-term fouling characteristics because the fouling increases the pressure loss and degrades the thermal performance of a heat exchanger. An experimental study was performed to investigate the characteristics of fluid flow and heat transfer in a fluidized bed heat exchanger with circulating various solid particles. The present work showed that the drag force coefficients of particles in the internal flow were higher than those in the external flow, in addition, the solid particle periodically hitting the tube wall broke the thermal boundary layer, and increased the rate of heat transfer. Particularly when the flow velocity was low, the effect was more pronounced.

A Study of Particle Diffusion from a Cavity in Flow Tube (유동관에 형성된 Cavity로부터의 입자확산현상 연구)

  • Lee, J.W.;Goo, J.H.;Kim, H.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.29-38
    • /
    • 1994
  • Particle contamination into and out of a cavity-cylindrical cavities with aspect ratios(width/depth) less than, equal to 1 and langer than 1, and also three dianensional T's attached to a cylindrical flow tube was studied numerically, using a finite difference method. In the process of unsteady particle diffusion, the particles contained in a concentration boundary layer near the tube wall plays an important role in the initial stage, after which a quasi-steady concentration profile is developed inside the cavity, resulting in an exponential change of concentration with time. Average concentration and its rate of change are observed to be closely correlated by a power law function in terms of Reynolds number and the logarithm of Schmidt number. Effects of the three parameters-Re, Sc, and aspect ratio-are analysed and well explained.

  • PDF

Investigation of wind-induced dynamic and aeroelastic effects on variable message signs

  • Meyer, Debbie;Chowdhury, Arindam Gan;Irwin, Peter
    • Wind and Structures
    • /
    • v.20 no.6
    • /
    • pp.793-810
    • /
    • 2015
  • Tests were conducted at the Florida International University (FIU) Wall of Wind (WOW) to investigate the susceptibility of Variable Message Signs (VMS) to wind induced vibrations due to vortex shedding and galloping instability. Large scale VMS models were tested in turbulence representative of the high frequency end of the spectrum in a simulated suburban atmospheric boundary layer. Data was measured for the $0^{\circ}$ and $45^{\circ}$ horizontal wind approach directions and vertical attack angles ranging from $-4.5^{\circ}$ to $+4.5^{\circ}$. Analysis of the power spectrum of the fluctuating lift indicated that vertical vortex oscillations could be significant for VMS with a large depth ratio attached to a structure with a low natural frequency. Analysis of the galloping test data indicated that VMS with large depth ratios, greater than about 0.5, and low natural frequency could also be subject to galloping instability.