• Title/Summary/Keyword: wake control

Search Result 210, Processing Time 0.022 seconds

A 1.8 V 0.18-μm 1 GHz CMOS Fast-Lock Phase-Locked Loop using a Frequency-to-Digital Converter

  • Lee, Kwang-Hun;Jang, Young-Chan
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.2
    • /
    • pp.187-193
    • /
    • 2012
  • A 1 GHz CMOS fast-lock phase-locked loop (PLL) is proposed to support the quick wake-up time of mobile consumer electronic devices. The proposed fast-lock PLL consists of a conventional charge-pump PLL, a frequency-to-digital converter (FDC) to measure the frequency of the input reference clock, and a digital-to-analog converter (DAC) to generate the initial control voltage of a voltage-controlled oscillator (VCO). The initial control voltage of the VCO is driven toward a reference voltage that is determined by the frequency of the input reference clock in the initial mode. For the speedy measurement of the frequency of the reference clock, an FDC with a parallel architecture is proposed, and its architecture is similar to that of a flash analog-to-digital converter. In addition, the frequency-to-voltage converter used in the FDC is designed simply by utilizing current integrators. The circuits for the proposed fast-lock scheme are disabled in the normal operation mode except in the initial mode to reduce the power consumption. The proposed PLL was fabricated by using a 0.18-${\mu}m$ 1-poly 6-metal complementary metal-oxide semiconductor (CMOS) process with a 1.8 V supply. This PLL multiplies the frequency of the reference clock by 10 and generates the four-phase clock. The simulation results show a reduction of up to 40% in the worstcase PLL lock time over the device operating conditions. The root-mean-square (rms) jitter of the proposed PLL was measured as 2.94 ps at 1 GHz. The area and power consumption of the implemented PLL are $400{\times}450{\mu}m^2$ and 6 mW, respectively.

Control of vortex shedding from circular cylinder by acoustic excitation (원통내부의 음향여기에 의한 와류유출제어)

  • Kim, Gyeong-Cheon;Bu, Jeong-Suk;Lee, Sang-Uk;Gu, Myeong-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1649-1660
    • /
    • 1996
  • The flow around a circular cylinder was controlled by an acoustic excitation issued from a thin slit along the cylinder axis. The static pressure distributions around the cylinder wall and flow characteristics in the near wake have been measured. Experiments were performed under three cases of Reynolds number, 7.8 * 10$\^$4/, 2.3 * 10$\^$5/ and 3.8 * 10$\^$5/. The effects of excitation frequency, sound pressure level and the location of the slit were examined. Data indicate that the excitation frequency and the slit location are the key parameters for controlling the separated flow. At Re$\_$d/, = 7.8 * 10$\^$4/, the drag is reduced and the lift is generated to upward direction, however, at Re$\_$d/, =2.3 * 10$\^$5/ and 3.8 * 10$\_$5/, the drag is increased and lift is generated to downward direction inversely. It is thought that the lift switching phenomenon is due to the different separation point of upper surface and lower surface on circular cylinder with respect to the flow regime which depends on the Reynolds number. Vortex shedding frequencies are different at upper side and lower side. Time-averaged velocity field shows that mean velocity vector and the points of maximum intensities are inclined to downward direction at Re$\_$d/ = 7.8 * 10$\^$4/, but are inclined to upward direction at Re$\_$d/ = 2.3 * 10$\^$5/.

Power consumption estimation of active RFID system using simulation (시뮬레이션을 이용한 능동형 RFID 시스템의 소비 전력 예측)

  • Lee, Moon-Hyoung;Lee, Hyun-Kyo;Lim, Kyoung-Hee;Lee, Kang-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1569-1580
    • /
    • 2016
  • For the 2.4 GHz active RFID to be successful in the market, one of the requirements is the increased battery life. However, currently we do not have any accurate power consumption estimation method. In this study we develop a simulation model, which can be used to estimate power consumption of tag accurately. Six different simulation models are proposed depending on collision algorithm and query command method. To improve estimation accuracy, we classify tag operating modes as the wake-up receive, UHF receive, sleep timer, tag response, and sleep modes. Power consumption and operating time are identified according to the tag operating mode. Query command for simplifying collection and ack command procedure and newly developed collision control algorithm are used in the simulation. Other performance measures such as throughput, recognition time for multi-tags, tag recognition rate including power consumption are compared with those from the current standard ISO/IEC 18000-7.

Wind-Tunnel Experiment for the Steady and Unsteady Torques of a Control Panel (제어판의 정상 및 비정상 토크에 관한 풍동시험)

  • M.S. Suh;S. Kauh;S.H. Kang
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.4
    • /
    • pp.98-103
    • /
    • 1992
  • The dynamic and static torque characteristics of a three dimensional control panel installed behind a guide panel were investigated in a wind tunnel. The panel was tested for various wind speeds, angles of attack and positions of the panel. The effects of the rotational speed and the amplitude of the sinusoidal motion were also studied. The increasing rate of torque coefficients with the angular position of the panel is small when the panel remains in the wake region, but is linear when it reaches the external stream. In case of a sinusoidal motion of the pannel, a hysterisis appears in the dynamic torque. The hysterisis becomes strong as the wind speed and the angular speed of the panel increase. The unsteady torque is considered quasi-steady when the angular speed is less than 5.5rad/s, i.e. the reduced frequency is less than 0.035.

  • PDF

An Energy-Efficient Asynchronous Sensor MAC Protocol Design for Wireless Sensor Networks (무선 센서 네트워크를 위한 에너지 효율적인 비동기 방식의 센서 MAC 프로토콜 설계)

  • Park, In-Hye;Lee, Hyung-Keun;Kang, Seok-Joong
    • Journal of IKEEE
    • /
    • v.16 no.2
    • /
    • pp.86-94
    • /
    • 2012
  • Synchronization MAC Protocol such as S-MAC and T-MAC utilize duty cycling technique which peroidically operate wake-up and sleep state for reducing energy consumption. But synchronization MAC showed low energy efficiency because of additional control packets. For better energy consumption, Asychronization MAC protocols are suggested. For example, B-MAC, and X-MAC protocol adopt Low Power Listening (LPL) technique with CSMA algorithm. All nodes in these protocols joining a network with independent duty cycle schedules without additional synchronization control packets. For this reason, asynchronous MAC protocol improve energy efficiency. In this study, a low-power MAC protocol which is based on X-MAC protocol for wireless sensor network is proposed for better energy efficiency. For this protocol, we suggest preamble numbering, and virtual-synchronization technique between sender and receive node. Using TelosB mote for evaluate energy efficiency.

Survey on Research and Development of Field Emission Electric Propulsion Thrusters (전계방출 전기추진 추력기 연구개발 현황)

  • Park, Jeongjae;Lee, Bok Jik;Jeung, In-Seuck
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.5
    • /
    • pp.36-52
    • /
    • 2021
  • As the application of nano-satellites constellation increases worldwide in the wake of New Space era, there is growing demand for the development of thrusters for precise attitude and orbit control of small satellites. Field Emission Electric Propulsion(FEEP) thruster uses a liquid metal as a propellant and accelerates the ionized liquid metal through a strong electric field at the tip of the metal surface. FEEP thruster technology is suitable for nano-satellites which require various missions for attitude and orbit control, because it provides thrust ranging from 1 µN to 1 mN with high specific impulse up to about 10,000 s and can be miniaturized due to its simple structure. In this paper, the basics of FEEP thrusters are introduced, then the current status of research and development of FEEP thrusters are presented.

Power Consumption Analysis of Asynchronous CSL mode MAC in Wi-SUN (Wi-SUN에서 비동기 CSL 모드 MAC의 전력소모 분석)

  • Yoon, Mi-Hee;Kim, Dongwon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.59-63
    • /
    • 2022
  • In recent years, research on smart factory wireless mobile communication technology that wirelessly remotely controls utilities is being actively conducted. The Wi-SUN(Wireless Smart Utility Network) Alliance proposed Wi-SUN protocol structure suitable for building a platform such as a smart factory as a new wireless communication standardization standard based on EEE802.15.4g/e. It analyzes the performance of the IEEE802.15.4e CSL(Coordinated Sampled Listening) Mode MAC(Media Access Control) in terms of power consumption and looks at considerations for efficient operation. Although CSL-MAC can dramatically reduce power consumption at the receiving end in an asynchronous manner, it has been found that the transmitting end has a disadvantage in that power consumption occurs due to an excessive wake-up sequence.

Relatively Decreased Level of Subjective Daytime Sleepiness and Its Associated Factors in Patients with Primary Insomnia (일차성 불면증 환자에서의 주간 졸림증과 연관된 수면변인에 대한 연구)

  • Lee, Yu-Jin;Lee, Jin-Sung;Sohn, Chang-Ho;Lee, Eun-Hye;Moon, Pil-Sung;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.12 no.2
    • /
    • pp.117-121
    • /
    • 2005
  • Objectives: The purpose of this study was to assess the difference of subjective daytime sleepiness level between primary insomnia patients and healthy control subjects. We also investigated the relationship between subjective daytime sleepiness level and variables of nocturnal polysomnograghic sleep architecture of insomnia patients. Method: Total subjects were 87 patients with primary insomnia diagnosed with polysomnography and 88 normal controls. The daytime sleepiness level in each group was measured by Korean version of Epworth Sleepiness Scale (ESS). The correlations of ESS score and nocturnal polysomnographic variables were calculated in the patient group. Results: Patients with insomnia had the lower ESS scores than the control group. In patients group, the ESS score showed significant negative correlations with total sleep time, sleep efficiency%, and stage 2 sleep time%. The ESS score also showed significant positive correlations with number of awakenings, number of awakenings more than 2 minutes, and wake after sleep onset time. Conclusions: Insomnia patients showed lower level of subjective daytime sleepiness that may indicate their higher alertness comparing to control subjects. Daytime sleepiness of patients with insomnia was associated with polysomnographic variables including total sleep time, sleep efficiency%, stage 2 sleep time% and disrupted continuity of nocturnal sleep.

  • PDF

Work Hours and Cognitive Function: The Multi-Ethnic Study of Atherosclerosis

  • Charles, Luenda E.;Fekedulegn, Desta;Burchfiel, Cecil M.;Fujishiro, Kaori;Hazzouri, Adina Zeki Al;Fitzpatrick, Annette L.;Rapp, Stephen R.
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.178-186
    • /
    • 2020
  • Background: Cognitive impairment is a public health burden. Our objective was to investigate associations between work hours and cognitive function. Methods: Multi-Ethnic Study of Atherosclerosis (MESA) participants (n = 2,497; 50.7% men; age range 44-84 years) reported hours per week worked in all jobs in Exams 1 (2000-2002), 2 (2002-2004), 3 (2004-2005), and 5 (2010-2011). Cognitive function was assessed (Exam 5) using the Cognitive Abilities Screening Instrument (version 2), a measure of global cognitive functioning; the Digit Symbol Coding, a measure of processing speed; and the Digit Span test, a measure of attention and working memory. We used a prospective approach and linear regression to assess associations for every 10 hours of work. Results: Among all participants, associations of hours worked with cognitive function of any type were not statistically significant. In occupation-stratified analyses (interaction p = 0.051), longer work hours were associated with poorer global cognitive function among Sales/Office and blue-collar workers, after adjustment for age, sex, physical activity, body mass index, race/ethnicity, educational level, annual income, history of heart attack, diabetes, apolipoprotein E-epsilon 4 allele (ApoE4) status, birth-place, number of years in the United States, language spoken at MESA Exam 1, and work hours at Exam 5 (β = -0.55, 95% CI = -0.99, -0.09) and (β = -0.80, -1.51, -0.09), respectively. In occupation-stratified analyses (interaction p = 0.040), we also observed an inverse association with processing speed among blue-collar workers (adjusted β = -0.80, -1.52, -0.07). Sex, race/ethnicity, and ApoE4 did not significantly modify associations between work hours and cognitive function. Conclusion: Weak inverse associations were observed between work hours and cognitive function among Sales/Office and blue-collar workers.

Effect of the HVAC Conditions on the Smoke Ventilation Performance and Habitability for a Main Control Room Fire in Nuclear Power Plant (원자력발전소 주제어실 화재 시 공조모드가 배연성능 및 거주성에 미치는 영향 분석)

  • Kim, Beom-Gyu;Lim, Heok-Soon;Lee, Young-Seung;Kim, Myung-Su
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.74-81
    • /
    • 2016
  • This study evaluated the habitability of operators for main control room fires in nuclear power plants. Fire modeling (FDS v.6.0) was utilized for a fire safety assessment so that it could determine the performance of the smoke ventilation and operator habitability with the main control room. For this study, it categorized fire scenarios into three cases depending on the conditions in the HVAC system. As a result of fire modelling, it showed that Case 1 (with HVAC) would give rise to the worst situation associated with the absolute temperature, radiative heat flux, optical density, and smoke layer height as deliberating the habitability and smoke ventilation. On the other hand, it showed that Cases 2 (w/o HVAC) and 3 can maintain much safer situations than Case 1. In the case of temperature at 820 s, Cases 2 and 3 were up to approximately 63% greater than Case 1 in the wake of ignition. In addition, the influence of radiative heat flux of Case 1 was even larger than Cases 2 and 3. That is, the radiative heat fluxes of Cases 2 and 3 were approximately 68% higher than Case 1. Furthermore, when it comes to considering the optical density, Case 1 was approximately 93% greater than Cases 2 and 3. Accordingly, it expected that the HVAC system can influence a the performance on the smoke ventilation that can be sustainable for operator habitability. On the other hand, it revealed an inconsecutive pattern for the smoke layer height of Cases 2 and 3 because supply vents and exhaust vents were installed within the same surface.