Fabrication of Prototype vuv Spectrometer & Liquid Target System Containing Hydrogen

  • Lee, Yun-Man;Kim, Jae-Hun;Kim, Jin-Gon;An, Byeong-Nam
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.586-586
    • /
    • 2012
  • The vuv spectrometer for ITER main plasma measurement is designed as a five-channel spectral system. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The overall system performance was verified by comparing the measured spectral resolutions with the calculated spectral resolutions. And we also have developed liquid jet target system. This study is about a neutron generator, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the ones operating at high neutron fluxes and maintained relatively thin with no need for water cooling. In this study, liquid target containing hydrogen has been developed and tested.

  • PDF

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF

Synthesis and Screening of the System $SrO-Gd_2O_3-Al_2O_3$Doped with Tb by Polymerized-Complex Combinatorial Chemistry (고분자 착체 조합 화학법을 이용한 Tb이 첨가된 $SrO-Gd_2O_3-Al_2O_3$계 형광물질의 합성 및 탐색)

  • Jeong, Yang Sun;Kim, Chang Hae;Park, Hee Dong;Park, Joon Taik;Kang, Sung Kwon
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.5
    • /
    • pp.461-469
    • /
    • 2001
  • The combinatorial approach has been applied to discover and optimize the composition of the novel or enhanced materials. In this study, we screened the optimum composition of the system SrO-Gd$_2$O$_3$-Al$_2$O$_3$ doped with $Tb^{3+}$ by a polymerized-complex combinatorial chemistry method. Mixtures with compositions of Sr, Gd and Al component that is in the range from 0 to 1 in about 0.05 increments could be tested. The sample powders were synthesized by a polymerized complex method. To prepare appropriately polymeric precursors, we used the metallic nitrates, citric acid and ethylene glycol. The luminescence properties of the synthesized powders are investigated using the UV and VUV (Vacuum-UV: 147 nm) photoluminescence spectrometer. In addition, the crystallinity and morphology of powder were monitored by X-ray diffraction spectrometer and scanning electron microscopy. In result of VUV PL works, there are good luminescent samples with the composition of 0.595 < x < 0.733 and 0.016 < y < 0.017 in Gd1-x-yAlxTbyO$\delta$ and 0.049 < x < 0.064 and 0.02 < y < 0.039 in $Sr_xAl_{1-x-y}Tb_yO_$\delta$$, their materials can be applicable to plasma display panels as the green phosphor.

  • PDF

Effect of pH and Drying Temperature on Luminescent Properties of Zn2SiO4:Mn,Al Green Phosphors by Sol-Gel Technique (졸-겔 합성에서 pH 및 건조온도가 Zn2SiO4:Mn,Al 녹색 형광체의 발광특성에 미치는 영향)

  • Sung, Bu-Yong;Han, Cheong-Hwa;Park, Hee-Dong
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.5 s.276
    • /
    • pp.333-337
    • /
    • 2005
  • In order to improve the performance of green emitting phosphors for plasma display panel, the $Zn_2SiO_4:Mn,Al$ phosphors were synthesized using sol-gel technique and studied using SEM and VUV photoluminescence spectrometer. pH values of the starting solutions (pH = 0.5$\~$2.34) were controled by HCl as the catalysis of hydrolysis and wet gels were dried at $80^{\circ}C$ and $120^{\circ}C$, respectively. We investigated the effects of pH and drying temperatures during sol-gel processes. The results indicated that the phosphor prepared at pH = 1 showed the maximum emission intensity in both drying conditions and the effect of pH of the starting solution on morphology were increased with particle size as HCl and phosphor dried at high temperature showed more spherical and smaller particles than at low.