• Title/Summary/Keyword: vsc

Search Result 276, Processing Time 0.025 seconds

Control of a VSC-HVDC Transmission System based on Modular Multilevel Converters (모듈형 멀티레벨 컨버터로 구성된 고압직류 송전시스템의 제어)

  • Cui, Shenghui;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.341-342
    • /
    • 2014
  • VSC-HVDC system based on Modular Multilevel Converter (MMC) is an emerging technology since compared to the conventional VSC-HVDC system an MMC presents several advantages such as modularity, low dv/dt, low harmonics, and low switching losses. In this paper, a comprehensive control strategy of an MMC-based VSC-HVDC system is proposed. In contrast to the conventional system control strategy, the DC side of the MMC operates as a controlled voltage source by the proposed method, and the dynamics of the transmission line voltage and current can be actively controlled. Validity of the proposed strategy was verified by 201-level full-scale computer simulation.

  • PDF

A Study on the Relationship Between Oral Malodor and Periodontal Disease (구취와 치주질환의 상관성에 관한 연구)

  • Kwon, Jin-Hee;Chang, Moon-Taek;Ryu, Sung-Hoon;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.1
    • /
    • pp.203-212
    • /
    • 2000
  • Putrefactive activity within the oral cavity is the principal cause of halitosis. The most common intraoral sites of oral malodor production are tongue, interdental and subgingival areas. The other foci may include faulty restorations, sites of food impaction and abscesses. Periodontal disease frequently involves pathological oral malodor, which is caused mainly by volatile sulfur compounds(VSC), such as hydrogen sulfide, methyl mercaptan, and dimethyl sulfide. The purpose of this study is to evaluate the association between oral malodor and periodontal status. Volatile sulfur compounds in mouth air were estimated by portable sulfide monitor($Halimeter^{TM}$). The results were as follows : 1. The levels of volatile sulfur compounds were significantly greater in a periodontitis group than in a control group(P<0.01). The amounts of VSC in mouth air from patients with periodontal involvement were four times greater than those of the control group. 2. The significant positive correlation was found between VSC concentrations and the number of pocket depth above 4mm(P<0.01), but correlation between VSC concentrations and plaque score was not statistically significant(P>0.05). 3. In the periodontitis group, VSC concentrations of pre-treatment significantly decreased after scaling and root planing(P<0.01). 4. No statistically significant correlation was found between VSC concentrations and sex / age in the periodontitis group. The above results indicate that periodontal disease may play a role as an important factor of oral malodor and deep periodontal pockets are a source of volatile sulfur compounds.

  • PDF

LCL Filter Design Method for Grid-Connected PWM-VSC

  • Majic, Goran;Despalatovic, Marin;Terzic, Bozo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1945-1954
    • /
    • 2017
  • In recent years, several LCL filter design methods for different converter topologies have been published, many of which use analytical expressions to calculate the ideal converter AC voltage harmonic spectrum. This paper presents the LCL filter design methodology but the focus is on presentation and validation of the non-iterative filter design method for a grid-connected three-phase two-level PWM-VSC. The developed method can be adapted for different converter topologies and PWM algorithms. Furthermore, as a starting point for the design procedure, only the range of PWM carrier frequencies is required instead of an exact value. System nonlinearities, usually omitted from analysis have a significant influence on VSC AC voltage harmonic spectrum. In order to achieve better accuracy of the proposed procedure, the system nonlinear model is incorporated into the method. Optimal filter parameters are determined using the novel cost function based on higher frequency losses of the filter. An example of LCL filter design for a 40 kVA grid-connected PWM-VSC has been presented. Obtained results have been used to construct the corresponding laboratory setup and measurements have been performed to verify the proposed method.

Application of energy function control strategy to VSC based UPFC Model (전압원 컨버터 기반의 UPFC 모델에 대한 에너지 함수 제어전략의 적용)

  • Kook, Kyung-Soo;Oh, Tae-Kyoo;Chun, Yeong-Han;Kim, Hak-Man;Kim, Tai-Hyun;Jeon, Jin-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.259-261
    • /
    • 2000
  • UPFC(Unified Power Flow Controller) consists of two voltage sourced converter(VSC)s inserted into AC system through series and parallel coupling transformer, where two VSCs are linked by capacitor at DC-side. Since VSC acts as an AC voltage source behind a reactance, where both magnitude and phase angle of the source are controllable, UPFC can be represented by the equation related to input-output relation of two VSCs. Voltage control of DC-link capacitor provides the path of real power flow between two VSCs. While UPFC is controlled for maintaining the given reference value in steady state, it should be controlled for damping power oscillation in dynamics. For such a control objective, the control strategy based on the energy function was proposed and has been shown to be effect and robust for damping power oscillation of power system. In this paper, UPFC model based on the VSC was analysed and applied to power-flow control and stability analysis. The control strategy based on the energy function is adopted for damping power oscillation of power system. The effectiveness of proposed control strategy was verified by simulation study

  • PDF

Evaluation on Tongue Coating, Volatile Sulfur Compounds, Salivary Flow Rate and Secretory Immunoglobulin A in Saliva in Patients with Oral Malodor (구취환자의 설태, 휘발성 황화합물, 타액분비율 및 타액내 secretory Immunoglobulin A에 대한 평가)

  • Kim, Jin-Sung;Eom, Guk-Hyeon
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.1
    • /
    • pp.258-264
    • /
    • 2008
  • Objectives : The aim of this study was to confirm the characteristics of oral malodor patients by evaluating the differences of salivary flow rate, secretory immunoglobulin A (sIgA) level in saliva between the patient and control groups, and the correlation with the tongue coating, volatile sulfur compound (VSC), salivary flow rate and sIgA level in saliva in the patients group. Methods : Forty-seven patients with oral malodor and twenty healthy volunteers were included in this study. Their tongue coating was assessed with the Winkel tongue coating index, and salivary flow rate, sIgA concentrations in saliva and the level of VSC in oral cavity were measured. Results : There were no significant differences of the salivary flow rate and the sIgA level in saliva between the patient and control groups, but there was a significant relationship between the accumulation of tongue coating and the level of VSC in oral cavity. Conclusions : Our results suggest that tongue coating is closely related to oral malodor, but further studies are needed to confirm the relationship between tongue coating and sIgA level in saliva.

  • PDF

Improvement of LCC-HVDC Input-Output Characteristics using a VSC-MMC Structure

  • Kim, Soo-Yeon;Park, Seong-Mi;Park, Sung-Jun;Kim, Chun-Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_1
    • /
    • pp.377-385
    • /
    • 2021
  • High voltage direct current(HVDC) systems has been an alternative method of a power transmission to replace high voltage alternate current(HVAC), which is a traditional AC transmission method. Due to technical limitations, Line commutate converter HVDC(LCC-HVDC) was mainly used. However, result from many structural problems of LCC-HVDC, the voltage source converter HVDC(VSC-HVDC) are studied and applied recently. In this paper, after analyzing the reactive power and output voltage ripple, which are the main problems of LCC-HVDC, the characteristics of each HVDC are summarized. Based on this result, a new LCC-HVDC structure is proposed by combining LCC-HVDC with the MMC structure, which is a representative VSC-HVDC topology. The proposed structure generates lower reactive power than the conventional method, and greatly reduces the 12th harmonic, a major component of output voltage ripple. In addition, it can be easily applied to the already installed LCC-HVDC. When the proposed method is applied, the control of the reactive power compensator becomes unnecessary, and there is an advantage that the cut-off frequency of the output DC filter can be designed smaller. The validity of the proposed LCC-HVDC is verified through simulation and experiments.

A Robust Scheme for Emergency Message Delivery in Vehicle Communications on Freeway (고속도로상의 차량간 통신에서 에러에 강한 긴급메시지 전달 기법)

  • Park, Jeong-Seo;Park, Tae-Keun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12A
    • /
    • pp.1113-1121
    • /
    • 2010
  • The Vehicle Safety Communications (VSC) is one of VANET applications for preventing vehicle accidents, and it utilizes vehicle-to-vehicle communication to exchange emergency messages. To propagate such messages in VSC, several schemes based on selective flooding have been proposed. Their common idea is that an emergency message is relayed by one of vehicles receiving the message. However, the schemes do not consider the transmission errors and duplications of an emergency event. In the schemes, if there are transmission errors and a vehicle detects a hazard, there may be vehicles which fail to receive an emergency message. If k vehicles detect a hazard, k emergency messages are created and propagated. The duplications of an event increase reliability of the message delivery but decrease efficiency. In this paper, we propose an emergency message delivery scheme which is efficient and robust to transmission errors. Our proposed scheme utilizes clustering for massage aggregation and retransmissions in a cluster. It also uses an acknowledgment mechanism for reliable inter-cluster communication. Our simulation results show that the proposed scheme outperforms Least Common Neighbor Flooding which is one of the selective flooding schemes.

Association Between Halitosis and Periodontal Disease Related Parameters in Dogs (개에서 구취와 치주질환 지표의 상관성에 관한 연구)

  • Kim, Se-Eun;Shim, Kyung-Mi;Yoo, Kyeong-Hoon;Ryu, Ji-Won;Koh, Hong-Bum;Moon, Chang-Jong;Kim, Jong-Choon;Kim, Sung-Ho;Kang, Seong-Soo;Bae, Chun-Sik
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.192-196
    • /
    • 2007
  • Oral malodor in companion animals is noticed by owners at first and it makes owners unpleasant. Therefore oral malodor affects the relationship between pet and owner. Oral malodor is produced by some putrefactive bacteria which putrefy proteins to volatile sulfur compounds (VSC) such as methyl mercaptan, hydrogen sulfide and dimethyl sulfide in the food remnants. And oral malodor is mostly consisted with these VSC. On oral examinations in dogs with oral malodor, it is common that plaque and calculus index were increased than normal dogs'. But organoleptic method is subjective to evaluate halitosis, in this study we measured VSC using organoleptic method and portable sulfide monitor to clarify the relationship between halitosis and periodontal disease in dogs with halitosis. And we found that plaque index and calculus index were significantly related with VSC (P<0.05, P<0.05) in measurement using Halimeter. However there was not significant relationship between gingivitis index and VSC. In conclusion, there was the significant, positive relationship between periodontal disease and halitosis.