• Title/Summary/Keyword: von Mises stresses

Search Result 155, Processing Time 0.025 seconds

Sensitivity analysis of shoulder joint muscles by using the FEM model

  • Metan, Shriniwas.S.;Mohankumar, G.C.;Krishna, Prasad
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.2
    • /
    • pp.115-127
    • /
    • 2016
  • Shoulder pain, injury and discomfort are public health and economic issues world-wide. The function of these joints and the stresses developed during their movement is a major concern to the orthopedic surgeon to study precisely the injury mechanisms and thereby analyze the post-operative progress of the injury. Shoulder is one of the most critical joints in the human anatomy with maximum degrees of freedom. It mainly consists of the clavicle, scapula and humerus; the articulations linking them; and the muscles that move them. In order to understand the behavior of individual muscle during abduction arm movement, an attempt has been made to analyze the stresses developed in the shoulder muscles during abduction arm movement during the full range of motion by using the 3D FEM model. 3D scanning (ATOS III scanner) is used for the 3D shoulder joint cad model generation in CATIA V5. Muscles are added and then exported to the ANSYS APDL solver for stress analysis. Sensitivity Analysis is done for stress and strain behavior amongst different shoulder muscles; deltoid, supraspinatus, teres minor, infraspinatus, and subscapularies during adduction arm movement. During the individual deltoid muscle analysis, the von Mises stresses induced in deltoid muscle was maximum (4.2175 MPa) and in group muscle analysis it was (2.4127MPa) compared to other individual four rotor cuff muscles. The study confirmed that deltoid muscle is more sensitive muscle for the abduction arm movement during individual and group muscle analysis. The present work provides in depth information to the researchers and orthopedicians for the better understanding about the shoulder mechanism and the most stressed muscle during the abduction arm movement at different ROM. So during rehabilitation, the orthopedicians should focus on strengthening the deltoid muscles at earliest.

Failure Probability Assessment of Natural Gas Pipeline under Combined Stresses (복합하중에 의한 천연가스 배관의 파손확률 평가)

  • Baek, Jong-Hyun;Chang, Yun-Chan;Kim, Ik-Jung;Kim, Cheol-Man;Kim, Young-Pyo
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.10-17
    • /
    • 2020
  • The structural reliability assessment can be used to improve the reliability in the asset integrity management of the pipeline by using a geometric variation, mechanical characteristics, load change and operating condition as evaluation factors. When evaluating structural reliability, the failure probability of the natural gas pipe is evaluated by the relationship of the resistance of the pipe material to external loads. The failure probability of the natural gas pipe due to the combined stresses such as the internal pressure, thermal stress and bending stress was evaluated by using COMREL program. When evaluating the failure probability of the natural gas pipe, a buried depth of 1.5 to 30 m, a wheel load of 2.5 to 20 ton, a temperature difference of 45℃, an operating pressure of 6.86MPa, and a soil density of 1.8 kN/㎥ were used. The failure probabilities of the natural gas pipe were evaluated by the Von-Mises stress criterion as the maximum allowable stress criterion under the combined stresses.

STRESS DISTRIBUTION OF THREE NITI ROTARY FILES UNDER BENDING AND TORSIONAL CONDITIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS (세가지 니켈 티타늄 파일의 휨과 비틀림 조건에서의 응력 분포에 관한 3차원 유한요소 연구)

  • Kim, Tae-Oh;Lee, Chan-Joo;Kim, Byung-Min;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.323-331
    • /
    • 2008
  • Flexibility and fracture properties determine the performance of NiTi rotary instruments. The purpose of this study was to evaluate how geometrical differences between three NiTi instruments affect the deformation and stress distributions under bending and torsional conditions using finite element analysis. Three NiTi files (ProFile .06 / #30, F3 of ProTaper and ProTaper Universal) were scanned using a Micro-CT. The obtained structural geometries were meshed with linear, eight-noded hexahedral elements. The mechanical behavior (deformation and von Mises equivalent stress) of the three endodontic instruments were analyzed under four bending and rotational conditions using ABAQUS finite element analysis software. The nonlinear mechanical behavior of the NiTi was taken into account. The U-shaped cross sectional geometry of ProFile showed the highest flexibility of the three file models. The ProTaper, which has a convex triangular cross-section, was the most stiff file model. For the same deflection, the ProTaper required more force to reach the same deflection as the other models, and needed more torque than other models for the same amount of rotation. The highest von Mises stress value was found at the groove area in the cross-section of the ProTaper Universal. Under torsion, all files showed highest stresses at their groove area. The ProFile showed highest von Mises stress value under the same torsional moment while the ProTaper Universal showed the highest value under same rotational angle.

Optimal Design of the Tractrix Die Used in the DDI Process for Manufacturing CG Pressure Vessels (CNG 압력용기 제작을 위한 D.D.I. 공정의 Tractrix 다이 최적설계)

  • Lee, Kwang O;Sim, Hyeon Dae;Kwak, Hyo seo;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.10
    • /
    • pp.879-886
    • /
    • 2016
  • Tractrix dies, used in the deep drawing process, can be used to form CNG pressure vessels without a blank holder. Previous studies had only applied tractrix profiles to perform the first deep drawing process of DDI; but an optimal design of the tractrix die that focuses on improving die life and reducing production cost has not been performed yet. In this study, finite element analyses of deep drawing processes were conducted according to heights of the tractrix die by using translating asymptotes. In addition, researchers analyzed von-Mises stresses at the part of stress concentration of the die according to the forming punch loads in order to propose an optimal tractrix die design.

A Study for Relation Between Fatigue and Structural Members on Othortropic Steel Deck (직교이방성 강바닥판 피로와 구조부재의 관계에 대한 연구)

  • Park, Jong In;Hong, Sung Nam;Kim, Tae Wan;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.41-50
    • /
    • 2012
  • Improvement of steel material quality made fatigue problems more critical than failure of the material itself. In many cases, cracks on the welded parts of steel deck bridges are reported against the failure of steel materials. And the cracks are caused by alternate stress on the welded parts due to live loads on the bridge. The range of alternate stress on the welded part is related to property of the sections which compose othortropic steel deck. Othortropic steel deck is mainly composed of deck plate, ribs and floor beams, wearing surface, etc. In this paper, a methology to estimate the alternate stress for pthortropic steel deck using Pelikan-Esslinger method and signed Von-Mises equivalent stress is proposed first. Parametric study served references for fatigue stresses when designing or repairing othortropic steel deck bridges, by analyzing relationship between alternate stress range and properties of steel deck members.

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

Stresses in FGM pressure tubes under non-uniform temperature distribution

  • Eraslan, Ahmet N.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.4
    • /
    • pp.393-408
    • /
    • 2007
  • The effects of material nonhomogeneity and nonisothermal conditions on the stress response of pressurized tubes are assessed by virtue of a computational model. The modulus of elasticity, the Poisson's ratio, the yield strength, and the coefficient of thermal expansion, are assumed to vary nonlinearly in the tube. A logarithmic temperature distribution within the tube is proposed. Under these conditions, it is shown that the stress states and the magnitudes of response variables are affected significantly by both the material nonhomogeneity and the existence of the radial temperature gradient.

A Study on the Structural Design in Automatic Transport System (자동반송장치의 구조설계에 관한 연구)

  • 김홍건
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.258-262
    • /
    • 1998
  • A structural design based of finite element analysis has been performed to investigate the reliable automatic transport system. For the procedure, different cross-sectional geometric factors were calculated and compared in detail. The von-Mises stresses were chosen to maintain a solid loading braring capacity for the safe design. Parametric studies showed that it is more inportant for the plate bending problem than the vertical loads of hanging bar to assess the safe and economic structural design.

  • PDF

Design and analysis of a newly devised linear flexure bearing(KIMM-LFB) for small precision reciprocating machines (소형 정밀 왕복동 기기용 선형 탄성 베어링 고유 모델(KIMM-LFB)의 설계 및 해석)

  • Choe Sang Gyu;Park Seong Je;Hong Yong Ju;Kim Hyo Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.344.1-344
    • /
    • 2002
  • A newly devised linear flexures bearing (KIMM-LFB) for reciprocating machines is disclosed having improved reliability for long lift. KIMM-LFB is an integrated device comprising a axially moving diaphragm with circumferentially arranged arc-shaped flexure blades secured between rim and hub spacers, which turn out to have higher radial stiffness and lower Von-Mises peak stresses than the one with circumferential tangent cantilever flexure blades. (omitted)

  • PDF

Finite Element Analysis and Experiment Study of Motorcycle Helmet (모터 싸이클 헬멧의 유한 요소 해석 및 실험 연구)

  • Thai, Huu-Tai;Kim, Seung-Eock
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.451-456
    • /
    • 2007
  • A finite element analysis and experiment study of a motorcycle helmet are presented in this paper. The finite element LS-DYNA3D code is used to analyze the helmet. The test specimen, instruments, and setup procedures are described. Since the displacements and Von-Mises stresses obtained by numerical analysis and experiment agree well, the numerical simulation is proved to be valid.

  • PDF