• Title/Summary/Keyword: volumetric frequency

Search Result 65, Processing Time 0.028 seconds

Low k Materials for High Frequency High Integration Modules

  • Na, Yoon-Soo;Lim, Tae-Young;Kim, Jin-Ho;Shin, Hyo-Soon;Hwang, Jong-Hee;Cho, Yong-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.4
    • /
    • pp.413-418
    • /
    • 2009
  • Glass systems based on Ca, Sr, Ba, and Zn modified alumino-boro silicates were investigated in order to improve the dielectric and mechanical properties of a typical LTCC (low temperature co-fired ceramic) which was developed for high frequency highly-integrated modules. The glass was prepared by a typical melting procedure and then mixed with cordierite fillers to fabricate glass/ceramic composite-type LTCC materials. The amount of cordierite filler was fixed at 50 volumetric%. For an optimal glass composition of 7.5% CaO, 7.5% BaO, 5% ZnO, 10% $Al_2O_3$, 30% $B_2O_3$, and 40% $SiO_2$ in mole ratio, the resultant LTCC composite showed a dielectric constant of 5.8 and a dielectric loss ($tan{\delta}$) of 0.0009 after firing at $900^{\circ}C$. An average bending strength of 160MPa was obtained for the optimal composition.

Design and Fabrication of 2D Array Ultrasonic Transducers with a Conductive Backer (전도성 후면층을 이용한 2D 배열 초음파 트랜스듀서의 설계 및 제작)

  • Woo, Jeongdong;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.502-508
    • /
    • 2013
  • In this paper, 2D array transducers using a conductive backer similar to 1-3 composites have been designed, fabricated, and evaluated. The conductive backer was based on well known manufacturing process of 1-3 composites with affordable ingredients. The 2D array transducer had 4,096 elements designed to have 3.5 MHz center frequency and a fractional bandwidth over 60 %. Fabricated prototype of the transducer satisfied the specifications in the center frequency and bandwidth. Performance over the entire elements was so uniform that the standard deviation was less than 0.81 dB. Thus applicability of the conductive backer proposed in this work to 2D array transducers was verified.

Investigations into the Cylinder Flow Stabilities with a Thin Film Attachment

  • Doh, Deog-Hee;Jo, Hyo-Je;Kwon, Seang-Yong;Kim, Hyoung-June;Cho, Gyeang-Rae;Shin, Byeong-Rog
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.7
    • /
    • pp.957-965
    • /
    • 2011
  • The wakes of a cylindrical body have been investigated. The cylindrical body was attached with a thin film. The film is made of silicon with configurations of 50mm(W) ${\times}$ 150mm(L) ${\times}$ 0.3mm(T). The cylinder wakes have been measured with PIV experiments under the conditions with and without the thin film. The diameter of the installed cylinder body is 30mm and the Reynolds numbers are 2730, 6160 and 9750 with the diameter. The measurement system consists of an Ar-ion laser(6W), a high speed camera(1024 ${\times}$ 992 pixel, 500fps) and a host computer. FFT analyses have been carried out using the velocity vectors obtained by PIV measurements at the point X/D=1.52 and Z/D=0.52. For understanding the three-dimensional flow structures, a new Volumetric PTV(particle tracking velocimetry) has been constructed, in which the same four high-resolution cameras have been used. It has been verified that the flexible film suppresses or damps the vortices separated from the cylinder body, which makes the cylinder's wakes stable. With increase of Re numbers the intensity of the dominant frequency of the wakes become smaller.

Reduction of the residual stresses during the additive manufacturing of a thermo-viscoelastic growing cylinder under non-uniform volumetric heating by electric induction

  • Fekry, Montaser
    • Structural Engineering and Mechanics
    • /
    • v.82 no.2
    • /
    • pp.259-270
    • /
    • 2022
  • The paper investigates the residual stresses arising in a thermoviscoelastic cylinder as a result of layer-by-layer deposition of material on its lateral surface. Internal stresses are caused by incompatible deformations that accumulate in the assembly as a result of joining parts with different temperatures. For the analysis of internal stresses, an analytical solution to the axisymmetric quasi-static problem of thermoelasticity for a growing cylinder is constructed. It is shown that the distribution of residual stresses depends on the scenario of the surfacing process. In this case, the supply of additional heat to the growing body can significantly reduce the unevenness of temperature fields and reduce the intensity of residual stresses. The most effective is uneven heating, which can be realized, by the action of an alternating current with a tunable excitation frequency. The temperature and residual stresses fields on the growing surface is analyzed numerically for Titanium and Copper materials.

A Study on the Atomizing Mechanism for the Swirl Nozzle (와권(渦卷) 노즐의 무화기구(霧化機構)에 관(關)한 연구(硏究))

  • Lee, Sang Woo;Sakai, Jun;Ishihara, Akira
    • Korean Journal of Agricultural Science
    • /
    • v.14 no.1
    • /
    • pp.81-97
    • /
    • 1987
  • Two nozzles with different size (Figure 2) were particularly designed to supply air through the swirl core into the central part of the liquid stream in the same parallel direction to produce a well-mixed air and water in the whirl chamber as spray liquid in bubble formation. Atomization was attempted to improve by using both the preliminary break-up process with less viscosity and less surface tension in the whirl chamber and the effects of increased frequency of the band of drops with the raised ambient air density in front of the nozzle orifice. The volumetric ratio between spray liquid and air on four levels was used to investigate the effects of air as a component of the mixture on atomization. The results of the experiment were summarized as follows; Droplet size became progressively finer as the operating pressure was increased in the range of $0.70kg/cm^2$ to $6.33kg/cm^2$, which was similar to the previous works. The new atomizing mechanism so-called 'air-center nozzle' gave a narrower range in droplet size distribution with smaller volumetric median diameter (VMD) than that of the existing spray system at a given pressure, which showed the possibility of improvement of atomization in a certain limit. The volumetric median diameter produced by the new atomizing mechanism was decreased from the central region toward the exterior edges across the spray pattern.

  • PDF

A Study on the Flow Characteristics of Debris Flow Using Small-scaled Laboratory Test (실내 모형실험을 통한 토석류 흐름 특성 연구)

  • Ryou, Kukhyun;Chang, Hyungjoon;Lee, Hojin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.235-245
    • /
    • 2021
  • Recently, the frequency of torrential rain is increasing due to climate change, which causes a large amount of debris flows. The purpose of this study was to understand the flow characteristics of debris flow according to the change in channel slope and volumetric sediment concentration and to analyze the effects of a berm on the flow characteristics of debris flow. The flow characteristics of debris flow, such as flow velocity, flow depth, Froude number, and flow resistance coefficients, were calculated using laboratory tests. The effect of a berm was analyzed by comparing the experimental results of a linear channel with those of a one-stepped channel. The results showed that the channel slope affected the flow velocity and flow depth, and the volumetric sediment concentration affected the flow velocity and flow depth, Froude number, and flow resistance coefficient. Moreover, as a berm was installed, the flow velocity and flow depth decreased by up to 26.1% and 71.2%, respectively. This means that installing a berm reduces the flow velocity, thereby reducing the mobility and kinetic energy. These results provide useful information to understand better the flow characteristics of debris flow and the effectiveness of a berm.

Determination of Proper Irrigation Scheduling for Automated Irrigation System based on Substrate Capacitance Measurement Device in Tomato Rockwool Hydroponics (토마토 암면재배에서 정전용량 측정장치를 기반으로 한 급액방법 구명)

  • Han, Dongsup;Baek, Jeonghyeon;Park, Juseong;Shin, Wonkyo;Cho, Ilhwan;Choi, Eunyoung
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.366-375
    • /
    • 2019
  • This experiment aims to determine the proper irrigation scheduling based on a whole-substrate capacitance using a newly developed device (SCMD) by comparing with the integrated solar radiation automated irrigation system (ISR) and sap flow sensor automated irrigation system (SF) for the cultivation of tomato (Solanum lycopersicum L. 'Hoyong' 'Super Doterang') during spring to winter season. For the SCMD system, irrigation was conducted every 10 minutes after the first irrigation was started until the first run-off was occurred, of which the substrate capacitance was considered to be 100%. When the capacitance threshold (CT) was reached to the target point, irrigation was re-conducted. After that, when the target drain volume (TDV) was occurred, the irrigation stopped. The irrigation volume per event for the SCMD was set to 50, 75, or 100 mL at CT 0.9 and TDV 100 mL during the spring to summer cultivation, and the CT was set to 0.65, 0.75, 0.80, or 0.90 in the winter cultivation. When the irrigation volume per event was set to 50, 75, or 100 mL, the irrigation frequency in a day was 39, 29, and 19, respectively, and the drain rate was 3.04, 9.25, and 20.18%, respectively. When the CT was set to 0.65, 0.75, or 0.90 in winter, the irrigation frequency was about 6, 7, 15 times, respectively and the drain rate was 9.9, 10.8, 35.3% respectively. The signal of stem sap flow at the beginning of irrigation starting time did not correspond to that of solar irradiance when the irrigation volume per event was set to 50 or 75 mL, compared to that of 100 mL. In winter cultivation, the stem sap flow rate and substrate volumetric water content at the CT 0.65 treatment were very low, while they were very high at CT 0.90 was high. All the integrated data suggest that the proper range of irrigation volume per event is from 75 to 100 mL under at CT 0.9 and TDV 100 mL during the spring to summer cultivation, and the proper CT seems to be higher than 0.75 and lower than 0.90 under at 75 mL of the irrigation volume per event and TDV 70 mL during the winter cultivation. It is going to be necessary to investigate the relationship between capacitance value and substrate volumetric water content by determining the correction coefficient.

Scheduling Non-drainage Irrigation in Coir Substrate Hydroponics with Different Percentages of Chips and Dust for Tomato Cultivation using a Frequency Domain Reflectometry Sensor (토마토 수경재배에서 FDR(Frequency Domain Reflectometry) 센서를 활용한 무배액 시스템에 적합한 코이어 배지의 Chip과 Dust 비율 구명)

  • Choi, Eun-Young;Choi, Ki-Young;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.248-255
    • /
    • 2013
  • This study examined an automated irrigation technique by a frequency domain reflectometry (FDR) sensor for scheduling irrigation for tomato (Solanum lycopersicum L. 'Starbuck F1') cultivation aimed at avoiding effluent from an open hydroponic system with coir substrate containing different ratios of chip-to-dust (v/v) content. Specifically, the objectives were to undertake preliminary measurements of irrigation volumes, leachate volume, volumetric water content and electrical conductivity (EC) in the substrate, plant growth, fruit yield, and water use efficiency resulting from variation in chip content as an initial experiment. Commercial coir substrates containing different percentages of chips and dust (0 and 100%, 30 and 70%, 50 and 50%, or 70 and 30%), two-story coir substrates with different percentages of chips in the lower layer and dust in the upper layer (15 and 85%, 25 and 75%, or 35 and 65%), or rockwool slabs were used. The results showed that a negligible or no leachate was found for all treatments when plants were grown under a technique for scheduling non-drainage irrigation using a frequency domain reflectometry (FDR) sensor. Daily irrigation volume was affected by chip content in both commercial and two-story slabs. The highest plant growth, marketable fruit weight, and water-use efficiency were observed in the plants grown in the commercial coir slab containing 0% chips and 100% dust, indicating that the FDR sensor-auto-mated irrigation may be more useful for tomato cultivation in coir substrate containing 0% chips and 100% dust using water efficiently and minimizing or avoiding leachate and thus increasing yield and reducing pollution. Detailed experiment is necessary to closely focus on determining appropriate irrigation volume at each of irrigation as well as duration of each individual irrigation cycle depending on different physical properties of substrates using an automated irrigation system operated by the FDR sensor.

Thin film thickness profile measurement using white light scanning interferometry (백색광 주사 간섭법을 이용한 박막의 두께 형상 측정법)

  • 김기홍;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.373-378
    • /
    • 1999
  • White light scanning interferometry is increasingly used for precision profile metrology of engineering surfaces, but its current application is primarily limited to opaque surfaces with relatively simple optical reflection behaviors. In this paper, a new attempt is made to extend the interferometric method to the thickness profile measurement of transparent thin film layers. An extensive frequency domain analysis of multiple reflection is performed to allow both the top and bottom interfaces of a thin film layer to be measured independently at the same time using nonlinear least squares technique. This rigorous approach provides not only point-by-point thickness probing but also complete volumetric film profiles digitized in three dimensions.

  • PDF

A Sliding Mode Control for an Engine Mount Using Magneto-Rheological Fluid (MR유체를 이용한 엔진마운트의 슬라이딩모드제어)

  • 이동길;안영공;정석권;양보석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1144-1149
    • /
    • 2001
  • In this paper, a sliding mode controller of a fluid engine mount using MR (Magneto-Rheological) fluid was discussed When the MR fluid is applied to a fluid mount, resistance of MR fluid can be controlled by electro-magnetic valve installed in the inertia track. Since the rheological property of the MR fluid shows a function of shear rate, the damping characteristics of the mount will be change according to the frequency. Changing an applied magnetic field to the valve changes the property of the mount, such as the resistance of the MR fluid, the notch and the resonant frequencies due to the fluid passing, quantity of the fluid passing, the effective piston area of the volumetric damping and stiffness. Therefore, the fluid mount using MR fluid can be regarded as a variable structure system The sliding mode control known well as a particular type of variable structure control was introduced in this study. The sliding mode control, which has inherent robustness, is also expected to improve the control performance in the engine mount The sliding mode controller for the mount formatted by taking into account the response property with a time constant to MR fluid and the variable mount property. The motion equations of the fluid mount are derived from Newton's law of motion and used in numerical simulation. Numerical simulations illustrate the effectiveness of the sliding mode controller.

  • PDF