• Title/Summary/Keyword: volume-up

검색결과 2,505건 처리시간 0.031초

고압하에서 ZrH2에 대한 X-선 회절 연구 (An X-ray Diffraction Study on ZrH2 under High Pressures)

  • 김영호
    • 한국광물학회지
    • /
    • 제9권1호
    • /
    • pp.35-42
    • /
    • 1996
  • Polycrystalline ZrH2 in tetragonal crystal system has been compressed in a modified Bassett-type diamond anvil cell up to 36.0 GPa at room temperature. X-ray diffraction data did not indicate any phase transitions at the present pressure range. The pressure dependence of the a-axis, c-axis, c/a and molar volume of ZrH2 was determined at pressures up to 36.0 GPa. Assuming the pressure derivative of the bulk modulus (K0') to be 4.11 from an ultrasonic value on Zr, bulk modulus (K0) was determined to be 160Gpa by fitting the pressure-volume data to the Birch-Murnaghan equation of state. Same sample was heated at $500^{\circ}C$ at the pressure of 9.8 GPa in a modified Sung-type diamond anvil cell. Unloaded and quenched sample revealed that the original tetragonal structure transforms into a hexagonal structured phase with a zero-pressure molar volume change of ~115.5%.

  • PDF

Shear and impact strength of waste plastic fibre reinforced concrete

  • Karanth, Savithri S;Ghorpade, Vaishali G;Rao, H Sudarsana
    • Advances in concrete construction
    • /
    • 제5권2호
    • /
    • pp.173-182
    • /
    • 2017
  • This paper is aimed at determining the shear and impact strength of waste plastic fibre reinforced concrete. M30 grade of concrete is prepared with waste plastic door fibres cut into 5 mm width and aspect ratios of 30, 50, 70, 90 and 110. Fibres are used in a volume fraction of 0 to 1.5% with an increment of 0.25%. L shaped specimens are cast for shear strength tests and flat plates of size $250{\times}250{\times}30mm$ are used for impact tests. "Drop ball method" is used for checking the impact strength. Shear strength is checked with L shaped specimens under UTM with a special attachment. It was found that up to 1.25% of waste plastic fibres can be effectively used for better strength of concrete both in shear and impact. Shear and impact strength were found to be increasing up to a volume fraction of fibres of 1.25%.

결합재량 및 다짐에너지에 따른 포러스콘크리트의 특성에 관한 연구 (A Study on the Properties of Porous Concrete according to Volume of Binder and Compaction Energy)

  • 이준;박승범;김정환;서대석;김범규;김형석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.513-516
    • /
    • 2004
  • The purpose of this study is to investigate properties of porous concrete according to volume of binder and compaction energy. The result of this study, as compaction energy goes on increasing, the actual measured void ratio is decreased according as a change of compaction energy and volume of binder. The compaction energy has a very near value by target void ratio on the whole when it is $50kN{\cdot}m/m^2,\;50\~75kN{\cdot}m/m^2$ in case of target void ratio is $15\%\;and\;25\%$. As compaction energy goes on increasing, compressive strength of specimens picked up when target void ratio is $20\%\;and\;25\%$. Also, compressive strength of specimens bluntly picked up when compaction energy is over $50\~75kN{\cdot}m/m^2$.

  • PDF

PVA 섬유와 실리카흄 첨가가 알칼리 활성 슬래그의 염화물 침투 저항성에 미치는 영향 (Effect of PVA Fiber and Silica Fume Addition on Chloride Penetration Resistance of Alkali-Activated Slag)

  • 윤현노
    • 도시과학
    • /
    • 제12권2호
    • /
    • pp.13-18
    • /
    • 2023
  • This study investigates the effect of polyvinyl alcohol (PVA) fiber and silica fume addition on the chloride penetration resistance of alkali-activated slag. Silica fume was added to replace slag at the dosage of 0, 5, 10, and 20% by weight of the binder, while PVA fiber was added at the dosage of 0, 1, and 2% by volume of the mixture. Samples were synthesized via alkali activator with 1.0 of silicate modulus and cured at room temperature for 28 days. Compressive strength test, permeable voids volume test, water absorprtion test, and rapid chloride penetration test were conducted for measuring the charaterisitics of alkali-activaed slag. The results showed that increasing silica fume content up to 10% in alkali-activated slag improved compressive strength and chloride penetration resistance. Addition of PVA fibers up to 1% by volume enhanced strength and chloride penetration resistance, but exceeding this led to reduced strength and durability due to increased void formation in the matrix.

CFD Study for Wave Run-up Characteristics Around a Truncated Cylinder with Damper

  • Zhenhao Song;Bo Woo Nam
    • 한국해양공학회지
    • /
    • 제37권6호
    • /
    • pp.225-237
    • /
    • 2023
  • In this study, numerical simulations for a single fixed truncated circular cylinder in regular waves were conducted to investigate the nonlinear wave run-up under various dampers and wave period conditions. The present study used the volume of fluid (VOF) technique to capture the air-water interface. The unsteady Reynolds-averaged Navier-Stokes (URANS) equation with the k- 𝜖 turbulence model was solved using the commercial computational fluid dynamics (CFD) software STAR-CCM+. First, a systematic spatial convergence study was conducted to assess the performance and precision of the present numerical wave tank. The numerical scheme was validated by comparing the numerical results of wave run-up on a bare truncated cylinder with the experimental results, and a good agreement was achieved. Then, a series of parametric studies were carried out to examine the wave run-up time series around the truncated cylinder with single and dual dampers in terms of the first- and second-order harmonic and mean set-up components. Additionally, the local wave field and the flow velocity vectors adjacent to the cylinder were evaluated. It was confirmed that under short wave conditions, the high position of the damper led to a noticeable increase in the wave run-ups with significant changes in the first- and second-order harmonic components.

병원 중환자의 경관유동식 공급 현황 및 영양상태 변화 (Degree of Enteral Tube Feeding in the Intensive Care Unit and Change in Nutritional Status)

  • 임현숙;박은경;이종호
    • 대한영양사협회학술지
    • /
    • 제7권3호
    • /
    • pp.217-226
    • /
    • 2001
  • It is important to supply adequate nutrition to critically ill patients, whose gastrointestinal system is properly functioning, through the enteral tube feeding if oral intake is impossible. In this study we investigated the changes in nutritional status with enteral tube feeding according to the volume required. We investigated the volume ordered according to the patient's requirements, volume infused according to the volume ordered in 41 enteral tube feeding patients in intensive care unit from Jannuary to July, 2000. Body weight, serum albumin level, and total lymphocyte count were evaluated to assess nutritional status. The mean fasting period was 5 days before the enteral feeding and patients whose fasting period over 3 days were 51%. The mean enteral tube feeding period was 29 days and method of feeding was nasogastric, bolus feeding 6 times per day. The volume ordered was 69.7% of the patients' recommended calorie and volume infused was 86.6% of their volume prescribed. Accordingly, the volume infused was estimated 61.7% of their volume required. Only 44.6% of their reqiured volume was infused within 3 days after enteral tube feeding was started. It took 16 days in average to meet the patients' recommended calorie; 56% of subjects still did not fully met their requirements by the end point. Among the impeding factors in supplying enteral tube feeding, factors related to the number of feeding were high residual volume in stomach, vomiting, gastrointestinal bleeding, abdominal distension and surgery. Factors related to the acctual infused volume were diarrhea, gastrointestinal bleeding, abdominal distension, airway management and tube reinsertion. Significant correlations were shown between the volume infused and changes in both the patients' weight and serum albumin level. Deviding the subjects into two groups by their infused volume, less than 70% and more than that, we compared the two to come up with a significant difference in their serum albumin level, -0.23 vs 0.21, and their body weight, -4.52 vs 0.12. In enteral tube feeding, the volume delivered in sufficient to the pateints' energy requirement can affect their nutriitional status in critically ill patient; adequate nutritional management plan is essential. It is necessary to make every effort to educate clinical staff and to set up a unified management program to prescribe adequate ammount of energy for the patient's nutritional requirement.

  • PDF

모터링 시동 및 시동정지 사이클에서 경사진 축을 갖는 저어널베어링의 마모 해석 - Part II: 경사진 축을 지지하는 두 저어널베어링의 마모해석 (Wear Analysis of Journal Bearings Operating in a Shaft During Motoring Start-up and Coast-down Cycles - Part II: Wear Analysis of two Journal Bearings Supporting a Misaligned Shaft)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제33권4호
    • /
    • pp.168-186
    • /
    • 2017
  • This paper presents a wear analysis procedure for calculating the wear of journal bearings during the start-up and coast-down cycles of a motoring stripped-down single cylinder engine operating with a tilted shaft. In order to decide whether the lubrication state of a journal bearing is in the mixed-elasto-hydrodynamic lubrication regime, we utilize lift-off speed and MOFT (most oil film thickness) under mixed-elasto-hydrodynamic lubrication regime at the corresponding aligned shaft. We formulate an equation for the modified film thickness in a misaligned journal bearing considering the additional wear volume described in Part I of this study. For this, we use the calculation results of the degree of misalignment and tilting angle obtained after finding the eccentricities of the two bearings supporting the crankshaft of a single cylinder engine. In this Part II, we calculate the wear of journal bearings using the fractional film defect coefficient, the asperity load sharing factor, and the modified specific wear rate for the application of mixed-elasto-hydrodynamic lubrication regime. We show that the accumulated wear volume after turning the ignition switch on and off once, increases to ${\sigma}=39{\mu}m$ and then decreases from ${\sigma}=39{\mu}m$ with increasing in surface roughness.

삼차원 적층복합재 구멍의 형상 최적화 (Shape Optimization of Three-Dimensional Cutouts in Laminated Composite Plates)

  • 한석영;마영준
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.275-280
    • /
    • 2004
  • Shape optimization was performed to obtain the precise shape of cutouts including the internal shape of cutouts in laminated composite plates by three dimensional modeling using solid element. The volume control of the growth-strain method was implemented and the distributed parameter chosen as Tsai-Hill fracture index for shape optimization. The volume control of the growth-strain method makes Tsai-Hill failure index at each element uniform in laminated composites under the initial volume. Then shapes optimized by Tsai-Hill failure index were compared with those of the initial shapes for the various load conditions and cutouts. The following conclusions were obtained in this study. (1) It was found that growth-strain method was applied efficiently to shape optimization of three dimensional cutouts in a laminate composite, (2) The optimal shapes of the various load conditions and cutouts were obtained, (3) The maximum Tsal-Hill failure index was reduced up to 67% when shape optimization was peformed under the initial volume by volume control of growth-strain method.

  • PDF

Theoretical Prediction of Lung Hyperinflation(LHI) Due to Asymmetric Pressure-Flow Characteristics of Human Airways During High Frequency Ventilation (HFV)

  • Cha, Eun-Jong
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권2호
    • /
    • pp.195-202
    • /
    • 1990
  • The hypothesis of asymmetric resistance to explain the phenomenon of lung hyperinflation (LHI) during hlgh frequency ventilation (HFV) was quantitatively studied. LHI was predicted by modeling the ism-volume pressure-flow (IVPF) data from 5 human subjects using the empirical Rohrer's equation. Non-steadiness during HFV was compensated by em- ploying recently proposed volume-frequency diagram. Tidal volume and ventilation frequency were 100 ml and 20 Hz, respectively. Airflow pattern was a symmetric sinusoid. The predic- tion results of mean pressure drop across the airways were averaged for those 5 subjects, and compared with zero by one-sided student's t-test. A marginally significant (P<0.1) increase in mean pressure drop was observed during HFV at low lung volumes (below FRC) , which could increase mean lung volume up to one liter When the lung volume was above FRC, no significant LHI (P >0.25) was resulted. LHI seemed to be inversely related to the lung volume. These results recommend to clinically apply HFV only at lung volumes above FRC.

  • PDF

혼화재를 다량 사용한 저발열 콘크리트의 모의부재실험 (Mock-up Test of Low Heat Concrete Using High Volume Mineral Admixture)

  • 김용로;송영찬;김효락;박종호;유정훈;정용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 2부
    • /
    • pp.31-34
    • /
    • 2011
  • In this study, for the evaluation of field application of low heat concrete using high volume mineral admixture, the characteristics of hydration heat generation and engineering properties of low heat concrete was investigated by mock-up test according to the replacement ratio of mineral admixture. Also, it was evaluated the compressive strength of low heat concrete with curing temperatures and ages for effective concrete mix design considering seasonal change.

  • PDF