• Title/Summary/Keyword: volume source

Search Result 998, Processing Time 0.032 seconds

Design and Implementation of Portable NMR Probe Magnet

  • Junxia, Gao;Yiming, Zhang;Jiashen, Tian
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.14-22
    • /
    • 2017
  • The NMR's probe consists of the static magnetic field generator (magnetic source) and the RF coil. It is very strict for the homogeneity of the static magnetic field intensity of the magnetic source, so the cost of the magnetic source is more expensive in the entire nuclear magnetic resonance instrument. The magnetic source generally consists of electromagnet, permanent magnet and superconducting magnet. The permanent magnet basically needs not to spend on operation and maintenance and its cost of manufacture is much cheaper than the superconducting magnet. Therefore, the permanent magnet may be the only choice for the static magnetic field device if we want to use the magnetic resonance instrument as an analyzer for production by reducing price. A new probe magnet was developed on the basis of the permanent magnet ring in this paper to provide a technological way for reducing the manufacturing cost, weight and volume of the existing nuclear magnetic resonance instrument (including MRI) probe.

A Numerical Study on the Source Mechanism of the Pressure Fluctuation Induced by Propeller Cavitation

  • Seol, Han-Shin;Moon, Il-Sung
    • Journal of Ship and Ocean Technology
    • /
    • v.12 no.2
    • /
    • pp.32-40
    • /
    • 2008
  • This paper deals with the pressure fluctuation induced by propeller cavitation. The main objective of this study is to analyze the source mechanism of the pressure fluctuation induced by propeller cavitation. To analyze the source mechanism of the pressure fluctuation, modem acoustic theory is applied. The governing equation of the pressure fluctuation induced by propeller is derived using Ffowcs Williams-Hawkings proposed time domain acoustic method. The physical mechanism of pressure fluctuation at the blade rate frequency is analyzed using numerically generated cavitation volume variation. Finally the characteristics of the pressure fluctuation induced by a propeller are presented.

The Effects of Financial Development on Foreign Direct Investment (금융 발전이 외국인직접투자에 미치는 영향에 대한 분석)

  • Jung-Whan Cho;Tae-Hwang Kim
    • Korea Trade Review
    • /
    • v.45 no.4
    • /
    • pp.195-205
    • /
    • 2020
  • This study investigates the effects of financial development on the foreign direct investment (FDI) flow in host countries. Using bilateral FDI data from 34 OECD source countries to 146 host countries, we performed panel data analysis based on a gravity FDI equation. We hypothesized that the financial development would increase the volume of FDI flows. The results suggest that the well-functioning finance market of source countries as well as a better accessable financial market of host countries contribute to the increase in FDI of OECD in their partner countries. We found also that the financial development effects of source countries are larger than those of host countries. This result shows that the financial development can play a crucial role to impact the FDI inflows as push factor in source country than as a pull factor in host countries.

Effects of Advanced Modeled Iterative Reconstruction on Coronary Artery Calcium (CAC) Scores (ADMIRE가 관상동맥 칼슘(CAC) 점수에 미치는 영향)

  • Lee, Sang-Heon;Lee, Hyo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.603-612
    • /
    • 2021
  • The effect of Advanced Modeled Iterative Reconstruction (ADMIRE) on the coronary artery calcium (CAC) score of computed tomography was evaluated. Coronary artery calcium images (348 calcium, 6 groups, total of 2088 calcium) were acquired by 128-slice dual-source CT of 89 patients.Volume score and Agatston score were measured from images reconstructed with filtered back projection (FBP) and ADMIRE (1-5). The difference between FBP and ADMIRE Strength (1-5) was confirmed through the Kruskal-Wallis test, and the post-hoc analysis was performed using the Mann-Whitney U test based on FBP. Both volume score and Agatston score showed statistically significant differences between FBP and ADMIRE (1-5) (P=0.015, P=0.0.38). As a result of post hoc analysis, the volume score decreased to 9.5% in ADMIRE 4 (Z=-2.359, P=0.018) and 13.2% in ADMIRE 5 (Z=-3.113, P=0.002) based on FBP. Agatston score decreased to 10.4% in ADMIRE 4 (Z=-2.051, P=0.040) and 14.0% in ADMIRE 5 (Z=-2.718, P=0.007) based on FBP. High ADMIRE strength affected the volume score and Agatston score due to the decrease in calcium area. In addition, the change in the Density factor due to the decrease in Maximum HU may affect the calculation of the Agatston score.

A Study on the Tracking of Count-Based Volumetric Changes in Nuclear Medicine Imaging (핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰)

  • Ji-Hyeon Kim;Jooyoung Lee;Hoon-Hee Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.57-69
    • /
    • 2024
  • Purpose: Quantitative analysis through count measurement in nuclear medicine planar images is limited by analysis techniques that are useful for obtaining various clinical information or by organ overlap or artifacts in actual clinical practice. On the other hand, the use of SPECT tomography images is quantitative analysis using volume rather than planar, which is not only free from problems such as projection overlap, but also has excellent quantitative accuracy. In the use of developing SPECT quantitative analysis technology, this study aims to compare the accuracy of quantitative analysis between ROI of the conventional planar images and VOI of the SPECT tomographic images in evaluating the count change happened by the volume change of the source. Materials and Methods: A 99mTcO4- source(200.17 MBq) was filled with sterilized water in the syringe to create a phantom with an inner diameter volume of 60 cc, and a planar image and a SPECT image were obtained by reducing the volume by 15 cc (25%) respectively. ROI and VOI(threshold: 1~45%, 5% interval) were set for each image obtained to estimate true count and measure the total count, and compared with the preseted volumetric change rate(%). Results: When volume changes of 25%, 50%, and 75% occurred in the initial volume of 60 cc(100%) of the phantom, the average count changes of the measured planar image were 26.8%, 53.2%, 77.5%, and the average count changes of the SPECT image were 24.4%, 50.9%, and 76.8%. In this case, the VOI size(cm3) set showed an average change rate of 25.4%, 51.1%, and 76.6%. The highest threshold value for the accuracy of radioactive concentration by VOI size (average error -1.03%) was 35%, and the VOI size of the same threshold had an error of -17.1% on average compared to the actual volume. Conclusion: On average, the count-based volumetric change rate in nuclear medicine images was able to track changes more accurately using VOI than ROI, but there was no significant difference with relatively similar value. However, the accuracy of radioactive concentration according to individual VOI sizes did not match, but it is considered that a relatively accurate quantitative analysis can be expected when the size of VOI is set smaller than the actual volume.

Quality Assessment of the Nationwide Water Pollution Source Survey Results on the Prioritized Toxic Water Pollutants from Industrial Sources in the Geum-River Basin by Exploratory Data Analysis (금강유역 산업계 특정수질유해물질 배출현황에 대한 탐색적 데이터 분석을 통한 전국오염원조사 결과 적합성 평가)

  • Kim, Eun-Ah;Kim, Yeon-Suk;Kim, Yong Seok;Rhew, Doug Hee;Jung, Je Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.585-595
    • /
    • 2014
  • The temporal trends of the prioritized toxic water pollutants generated and discharged from the industrial facilities in the Geum-River basin, Korea were analyzed with the results of the nationwide Water Pollution Source Survey conducted in 2001 - 2012. The statistical results indicated rapid increase in the volume of raw toxic wastewaters whereas the amount of each toxic pollutant kept fluctuating for 12 years. Serious discrepancies in the survey data of the same type of industries demonstrated a low reliability of the survey result, which stemmed from several error factors. A unit-load for each type of industrial facility was devised to estimate the amount of prioritized toxic water pollutant based on the total volume of industrial wastewater generated from the same type of industrial facilities. The supplementary measures with an effective permit issuance policy and adding survey parameters of terminal wastewater treatment plants to use them as references to the Water Pollution Source Survey were suggested as means to minimize the errors associated with the false reports from the industries.

THE AKARI FIR ALL-SKY POINT SOURCE CATALOGUES: IMPROVEMENT ACTIVITIES

  • Makiuti, Sin'itirou;Yamamura, Issei;Koga, Tatsuya;Nakada, Tatsuya;AKARI team
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.17-19
    • /
    • 2017
  • The first version of the AKARI far-infrared All-Sky Bright Source Catalogue (BSC ver.1) was released to public in March 2010. It has been widely used for various astrophysical researches. We are continuing efforts to produce the next edition. The new version is expected to be improved in accuracy and reliability, as well as its volume. Many improvements to the next version are in progress. The time-line signal is being re-examined throughout the entire data processing. Correction processes for signal linearity and detector responsivity, and procedure for masking signal anomaly are revised. The source extraction process is further tuned and operating parameters will be optimized. These bring better reliability of the source detection and possibly an increase of source numbers. The position accuracy is expected to be improved. Systematic position error seen around the Galactic plane will also be corrected. We also plan to deliver the Faint Source Catalogue version 1.

Prediction of Interior Noise Caused by Tire Based on Sound Intensity and Acoustic Source Quantification (공기 기인 소음 분석과 음향 인텐시티법을 이용한 타이어에 의한 실내 소음 예측)

  • Shin, Kwang-Soo;Lee, Sang-Kwon;Hwang, Sung-Uk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.315-323
    • /
    • 2013
  • Tire noise is divided into a road noise(structure-borne noise) and a pattern noise(air-borne noise). Whilst the road noise is caused by the structural vibration of the components on the transfer path from tire to car body, the pattern noise is generated by the air-pumping between tire and road. In this paper, a practical method to estimate the pattern noise inside a passenger car is proposed. The method is developed based on the sound intensity and airborne source quantification. Sound intensity is used for identifying the noise sources of tire. Airborne source quantification is used for estimating the sound pressure level generated by each noise source of a tire. In order to apply the airborne source quantification to the estimation of the sound pressure, the volume velocity of each source should be obtained. It is obtained by using metrics inverse method. The proposed method is successfully applied to the evaluation of the interior noises generated by four types of tires with different pattern each other.

Effect of Ginseng Saponin, Gypsophila Saponin, and Detergents on Volume Changes and Fragility of Red Blood Cells (인삼(人蔘) Saponin, 은시호(銀柴胡) Saponin 및 계면활성제(界面活性劑)가 적혈구(赤血球)의 용적변화(容積變化) 및 Fragility에 미치는 영향(影響))

  • Lee, Shin-Woong;Lee, Jeung-Soo;Lee, Soo-Kun;Ok, Chang-Kun;Kim, Young-Hie
    • YAKHAK HOEJI
    • /
    • v.33 no.1
    • /
    • pp.15-19
    • /
    • 1989
  • The effects of Gypsophila saponin, sodium dodecylsulfate (SDS) and Triton X-100 on volume changes and fragility of red blood cells were compared to ginseng saponin to elucidate whether there are any difference in their action on membrane lipid. Cell volume was decreased to about 38% in 1M NaCl and increased to about 20% in 1/10M NaCl. Hematocrit value was decreased by Gypsophila saponin, SDS, and Triton X-100 which caused hemolysis in isotonic NaCl solution. These detergents also inhibited increase of cell volume and accelerated hemolysis in hypotonic solution. However, ginseng saponin did not influence to osmotic volume changes and hemolysis of red blood cells. These results suggest that the disruptive effect of plant saponin on membrane barriers induced by removing membrane lipid is different from their source and ginseng saponin has very low affinity to membrane lipid.

  • PDF

Exploiting Programmable Shaders in Hardware-Assisted Volume Rendering (PC용 그래픽스 가속기의 쉐이더 기능을 이용한 볼륨 렌더링)

  • Im, In-Seong;Gang, Byeong-Gwon
    • Journal of the Korea Computer Graphics Society
    • /
    • v.8 no.2
    • /
    • pp.23-29
    • /
    • 2002
  • In this paper, we describe an implementation technique that extends the classification and shading capabilities offered by previously reported hardware-assisted volume rendering algorithms. In designing our rendering scheme, we exploited the programmable shader technology supported by the latest consumer PC graphics hardware. Our direct volume rendering technique enables to simultaneously display up to four materials, and to dynamically control gradient magnitude to emphasize or de-emphasize surface boundaries. It can easily create lighting effects such as light source attenuation, depth cueing, and multiple light sources that were often difficult to realize in previous hardware-assisted volume rendering.

  • PDF