An Experimental Study on the Accuracy of Concrete Unit-Water Content Using High-frequency Water Fraction Sensors (고주파수분센서를 이용한 콘크리트 단위수량 평가 정확도에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Yu, Seung-Hwan;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.61-62
    • /
    • 2022
  • The unit quantity is an important factor influencing the durability, workability, and quality of concrete. Methods for measuring the unit quantity include a high frequency heating method, a unit volume mass method, a capacitance method, and a microwave method. However, these methods have disadvantages of poor measurement method, time required, and accuracy, and a relatively experimental method compensating for these disadvantages was used to measure the unit quantity using a high frequency main sensor (FDR) capable of simple and fast measurement. In addition, the unit quantity was evaluated by analyzing the measurement data through deep learning.

  • PDF

An Experimental Study on the Evaluation of Unit-Water Content Acoording to Concrete Aggregate Variables through FDR Sensor (FDR 센서를 통한 콘크리트 골재 변수에 따른 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.70-71
    • /
    • 2021
  • The unit quantity that affects the workability, shrinkage cracking, and durability of concrete is an important factor. Methods for measuring the unit quantity include a high frequency heating method, a capacitance method, a unit volume mass method, and a simple method. However, these methods have the disadvantage of poor measurement method, time required, and precision. To solve this problem, a relatively simple and fast measurement method was adopted to compensate for the shortcomings through a Frequency Domain Reflection (FDR) sensor, and the unit quantity was used. In addition, the measurement data was analyzed by deep learning to evaluate the unit quantity of concrete.

  • PDF

Study on the Influence of Mixing Effect to the Measurement of Particle Size Distribution using DMA and CPC (혼합효과가 DMA와 CPC를 이용한 입자분포 측정에 미치는 영향에 관한 연구)

  • Lee, Youn-Soo;Ahn, Kang-Ho;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.326-333
    • /
    • 2003
  • In the measurement using DMA and CPC in series, there is some time delay for particles classified in DMA to detect in CPC. During this time, the DMA time-response changes due to the velocity profile of sampling tube and the diffusion of particles in the volume that exists between the DMA exit and the detector of ultra-fine CPC. This is called mixing effect. In the accelerated measurement methods like the TSI -SMPS, the size distribution is obtained from the correlation between the time-varying electrical potential of the DMA and the corresponding particle concentrations sampled in DMA. If the DMA time -response changes during this delay time, this can cause the error of a size distribution measured by this accelerated technique. The kernel function considering this mixing effect using the residence time distribution is proposed by Russell et al. In this study, we obtained a size distribution using this kernel to compare to the result obtained by the commercial accelerated measurement system, TSI -SMPS for verification and considered the errors that result from the mixing effect with the geometric mean diameters of originally sampled particles, using virtually calculated responses obtained with this kernel as input data.

The Effect of Sample Handling on the Rheological Measurement of Regenerated Silk Fibroin Formic Acid Solution using Parallel Plate Geometry

  • Cho, Hee-Jung;Um, In-Chul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.22 no.1
    • /
    • pp.5-10
    • /
    • 2011
  • The effect of sample handling condition on the rheological measurement of regenerated silk fibroin formic acid solution using parallel plate geometry was investigated. In case of loading method, the loading by pouring sample solution resulted in the best reproducibility of rheological measurement. Loading with spoon showed a high variance of viscosity value at low shear rate region ($0.01{\sim}1sec^{-1}$) while loading with syringe exhibited a low reproducibility of viscosity at high shear region ($1{\sim}100sec^{-1}$) with a disappearance of shear thinning phenomenon. It was revealed that the sample loading with small extra amount lead to the most reproducible result. The sample loading with the exact amount for the measuring plate resulted in a lack of reproducibility of high shear viscosity, while the loading with large extra volume produced a limited consistency of low shear viscosity. It was turned out that 3 min. of waiting time before measurement was the optimum condition for reliable result. When the waiting time was less than 1 min., the low shear viscosity was obtained with a lack of consistency. On the other hand, the sample solution started drying when the waiting time increased up to 5 min.

The Development of the Components of the Length Measurement Concept in the Procedure of Measurement Using a Ruler

  • Antic, Milica D.;Dokic, Olivera J.
    • Research in Mathematical Education
    • /
    • v.22 no.4
    • /
    • pp.261-282
    • /
    • 2019
  • The research related to testing pupils' achievement in the field of Measurement and Measure in initial teaching of geometry points to an insufficient adoption of the basic components of the length measurement concept among pupils. In order to discover the cause, we looked at the basic components on which the procedure of measuring length using a ruler is based, highlighted the possibilities of introducing the procedure in measuring length, and determined pupils' achievement during the procedure of measuring length using a ruler. The research sample consisted of 145 pupils, out of which 72 were the 2nd grade pupils and 73 were the 4th grade pupils. A descriptive method was applied in the research. The technique we used was testing, and for the statistical data processing we used a χ2 test. The results of the research show that, when drawing a straight line of a given length using a ruler, there is no statistical difference in achievement between the 2nd and 4th grade pupils, nor in the pupils' knowledge regarding drawing a ruler independently, while drawing a straight line of a given length using a "broken" ruler 4th grade pupils are statistically better. The results of the research indicate that pupils' achievement is better in doing standard tasks than in non-standard ones, given that the latter require conceptual knowledge. The components of the concept of length measurement using ruler have not been sufficiently developed yet, and these include: zero-point, partitioning a measured object in a series of consecutive measurement units and their iteration. We shed more light on the critical stage in the procedure of length measurement - the transition from non-standard to standard units and the formation of the length measurement scale. For further research, we propose to look at the formation of the concept of length measurement using the ruler through all its components and their inclusion in the mathematics curriculum, as well as examining the correlation of pupils' achievement in the procedure of measuring length with their achievement in measuring area (and volume).

The Study on the Biomechanical Body Segment Parameters of Korean Adults with References to Sasang Constitutional Medicine (한국인 신체분절에 관한 사상의학적 연구)

  • Lee, Eui-ju;Lee, Jae-koo;Kim, Jeong-yun;Song, Jeong-mo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.1
    • /
    • pp.143-160
    • /
    • 1998
  • PURPOSE This studied the biomechanical body segment parameters of Korean adults with reference to Sasang Constitutional Medicine(SCM). We anlyzed the characteristics of Sasang constitution through Body Measurement, Immersion Method, and Reaction Board Method. SUBJECT Subjects were 72 persons. There were made 49 and Female 23. Mean age was . And There were Taeumin 30, Soyangin 17, and Soeumin 25. METHOD The items of Body Measurement were 51. Limbs were measured right side. Volume was gained with Immersion Method and Weight was calculated with the density equation for limbs from Drills and Contini. Center of Mass was gained with Reaction Board Method. RESULT 1. In Body Measurement there were the significant differences with each constitution of man's circumference. 2. In Volume there were the significant differences between Taeumin and Soeumin in mand. And the volume rate of head and neck, hand, and foot was the lowest in Taeumin, but the highest in Soeumin. 3. In center of mass Soyangin was higher than others.

  • PDF

Interfacial Properties and Sensing of Carbon Nanofiber/Tube and Electrospun Nanofiber/Epoxy Composites Using Electrical Resistance Measurement and Micromechanical Technique (전기저항측정 및 미세역학시험법을 이용한 탄소나노섬유/튜브 및 전기방사된 나노섬유/에폭시 복합재료의 계면특성 및 감지능 연구)

  • Jung Jin-Gyu;Kim Sung-Ju;Park Joung-Man
    • Composites Research
    • /
    • v.18 no.4
    • /
    • pp.21-26
    • /
    • 2005
  • Nondestructive damage sensing and load transfer mechanisms of carbon nanotube (CNT) and nanofiber (CNF)/epoxy composites have been investigated by using electro-micromechanical technique. The electrospun PVDF nanofibers were also prepared as a piezoelectric sensor. The electro-micromechanical techniques were applied to evaluate sensing response of carbon nanocomposites by measuring electrical resistance under an uniform cyclic loading. Composites with higher volume content of CNT showed significantly higher tensile properties than neat and low volume$\%$ CNT composites. CNT composites showed humidity sensing within limited temperature range. CNT composites with smaller aspect ratio showed higher apparent modulus due to high volume content in case of shorter aspect ratio. Thermal treated electrospun PVDF nanofiber showed higher mechanical properties than the untreated case due to crystallinity increase, whereas load sensing decreased in heat treated case. Electrospun PVDF nanofiber web also showed sensing effect on humidity and temperature as well as stress transferring. Nanocomposites and electrospun PVDF nanofiber web can be applicable for sensing application.

A suggestion of Aortic wall Stiffness Evaluation Technique Independent on Changeable Blood Pressure : Aortic Distensibility Index (변화하는 혈압의 영향을 받지 않는 동맥 벽의 강화도 측정 방법 제안 : 대동맥 확장지수)

  • Seo, Jee-Hye;Choi, Dong-Ho;Wu, Zhuqing;Rienmueller, Rainer;Lee, Jong-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.151-158
    • /
    • 2008
  • To evaluate aortic wall stiffness without influence of different background blood pressure, a new technique was developed and verified. At eight swine descending aortae, volume-pressure measurement was performed using custom-made system. Based on averaged pressure-volume curve, aortic distensibility index was formulated to evaluate aortic wall stiffness regardless of variable blood pressure and aortic size. The variability of aortic distensibility index by pressure change was compared with other parameters for wall stiffness evaluation. Subsequently, the aortic distensibility index was calculated at 100 contrast-enhanced EBCT data sets of normal volunteers in regular health screening program. The measured aortic distensibility index was compared with age, coronary calcium score, and aortic calcium score. Between 50 and 360 mmHg of blood pressure, the coefficient of variance of aortic distensibility index was 22.00% as comparing with 88.99% of classical compliance. Based on age, aortic distensibility index showed correlation coefficient of 0.55, whereas classical compliance showed 0.26. The correlation coefficient with modified aortic calcification was 0.43. Linear regression study revealed statistical significance of correlation coefficients. The aortic distensibility index, the method to evaluate aortic wall stiffness free from variable blood pressure and aortic size, was developed and verified with significant practical feasibility.

Effects of the Neck Stabilizing Exercise Combined With the Respiratory Reeducation Exercise on Deep Neck Flexor Thickness, Forced Vital Capacity and Peak Cough Flow in Patients With Stroke (목 안정화와 호흡 재교육 운동이 만성 뇌졸중 환자의 목 깊은 굽힘근육의 두께, 노력성 폐활량과 최대 기침 유량에 미치는 효과)

  • Lee, Myoung-Hyo;Hwang-bo, Gak
    • Physical Therapy Korea
    • /
    • v.22 no.1
    • /
    • pp.19-29
    • /
    • 2015
  • Impaired respiratory function is common in patients with stroke. The purpose of this study were to investigate the effectiveness of exercises and to assess forced vital capacity and peak cough flow after completion of neck stabilizing and respiratory reeducation exercises (combining diaphragmatic breathing and pursed-lip breathing exercises). The 45 participants were randomly assigned to an experimental group 1 ($n_1=15$), experimental group 2 ($n_2=15$), and a control group ($n_3=15$). All subjects performed conservative physical therapy for 30 minutes. Experimental group 1 undertook the neck stabilizing exercise and the respiratory reeducation exercise. Experimental group 2 undertook the respiratory reeducation exercise. Additional exercise did not exceed 30 minutes, five times a week for six weeks. The subjects were assessed for deep neck flexor thickness and breathing function (forced vital capacity, forced expiratory volume at one second, forced expiratory volume at one second/forced vital capacity, peak expiratory flow, and manual assisted peak cough flow) at pre-post value. The results of this study were as follows. Experimental group 1 showed a significant increase only in deep neck flexor thickness change rate (p<.05). All groups showed significant increases in forced vital capacity, forced expiratory volume at one second, and peak expiratory flow in pre-post measurement (p<.05). Experimental groups 1 and 2 showed an increase in manual assisted peak cough flow in pre-post measurement (p<.05). There was no significant difference between experimental group 1 and experimental group 2, but experimental group 1 improved more than experimental group 2 in respiratory function as a whole. In conclusion, these findings suggest that the neck stabilizing exercise in combination with the respiratory reeducation exercise can improve forced vital capacity and peak cough flow in patients with stroke.

Uncertainty Analysis of the Calculated Radioactivity in Liquid Effluent Released as Batch Mode from a Nuclear Power Plant (발전용원자로에서 뱃치방식으로 배출되는 액체상 방사성물질의 방사능 평가결과에 대한 불확도 해석)

  • 정재학;박원재
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.562-571
    • /
    • 2003
  • A series of factors such as sampling, pretreatment measurement, volume estimation which induces uncertainty of the calculated radioactivity in liquid effluent released from a nuclear power plant were analyzed. It is innately impossible to estimate exact error of the calculated radioactivity, since most of the input parameters are determined by a single measurement and true value of the released radioactivity cannot be known. In this paper, a systematic model to calculate uncertainty of the released liquid radioactivity was developed based upon the guidance report published by the ISO in 1993, and the model was applied to a set of hypothetical batch release conditions. As a result, the Priority of each input parameter was turned out to be (1) wastewater volume, (2) sample volume, and (3) measured radioactivity of the sample. In addition, probability distribution of the released radioactivity was simulated by Monte Carlo method combining the probability distribution of each input parameter It was shown that the radioactivity released to the environment, which has been reported as a single value, has a certain form of probability distribution.

  • PDF