• 제목/요약/키워드: voltage contrast

검색결과 285건 처리시간 0.036초

병렬커패시터를 사용한 DC chopper의 특성연구 (A study on the characteristics of DC chopper using a parallel chpacitor)

  • 김한성
    • 전기의세계
    • /
    • 제31권3호
    • /
    • pp.226-234
    • /
    • 1982
  • DC choppers are usually used to control the DC motor by varying the average value of DC input voltage to the DC motors. In this paper, a chopper circuit is suggested and reconstructed by replacing the free-wheeling diode with the parallel capacitor in the conventional ones. It is demonstrated that this chopper circuit with capacitor can reduce the ripples of the output voltage and current in contrast to those of the chopper with diode, and it can be controlled the output waveforms smoothly at high power demand.

  • PDF

Accurate Voltage Parameter Estimation for Grid Synchronization in Single-Phase Power Systems

  • Dai, Zhiyong;Lin, Hui;Tian, Yanjun;Yao, Wenli;Yin, Hang
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1067-1075
    • /
    • 2016
  • This paper presents an adaptive observer-based approach to estimate voltage parameters, including frequency, amplitude, and phase angle, for single-phase power systems. In contrast to most existing estimation methods of grid voltage parameters, in this study, grid voltage is treated as a dynamic system related to an unknown grid frequency. Based on adaptive observer theory, a full-order adaptive observer is proposed to estimate voltage parameters. A Lyapunov function-based argument is employed to ensure that the proposed estimation method of voltage parameters has zero steady-state error, even when frequency varies or phase angle jumps significantly. Meanwhile, a reduced-order adaptive observer is designed as the simplified version of the proposed full-order observer. Compared with the frequency-adaptive virtual flux estimation, the proposed adaptive observers exhibit better dynamic response to track the actual grid voltage frequency, amplitude, and phase angle. Simulations and experiments have been conducted to validate the effectiveness of the proposed observers.

On the Lightning Induced Voltage Along Overhead Power Distribution Line

  • Izadi, Mahdi;Ab Kadir, Mohd Zainal Abidin;Hajikhani, Maryam
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1694-1703
    • /
    • 2014
  • Lightning induced voltage is a major factor that causes interruptions on distribution lines. In this paper, analytical expressions are proposed to evaluate a lightning induced voltage on power lines directly in the time domain without the need to apply any extra conversions. The proposed expressions can consider the widely used current functions and models in contrast to the earlier analytical expressions which had a number of limitations related to the simplification of the channel base current and the current along the lightning channel. The results show that the simulated values based on the proposed method are in good agreement with the previous studies and the proposed expressions can be used for optimizing the insulation and protection level of existing and new lines being designed.

Optimized Design of Bi-Directional Dual Active Bridge Converter for Low-Voltage Battery Charger

  • Jeong, Dong-Keun;Ryu, Myung-Hyo;Kim, Heung-Geun;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.468-477
    • /
    • 2014
  • This study proposes an optimized design of a dual active bridge converter for a low-voltage charger in a military uninterrupted power supply (UPS) system. The dual active bridge converter is among various bi-directional DC/DC converters that possess a high-efficiency isolated bi-directional converter. In the general design, the zero-voltage switching(ZVS) region is reduced when the battery voltage is high. By contrast, efficiency is low because of high conduction losses when the battery voltage is low. Variable switching frequency is applied to increase the ZVS region and the power conversion efficiency, depending on battery voltage changes. At the same duty, the same power is obtained regardless of the battery voltage using the variable switching frequency. The proposed method is applied to a 5 kW prototype dual active bridge converter, and the experimental results are analyzed and verified.

Optimal Conditions for Defect Analysis Using Electron Channeling Contrast Imaging

  • Oh, Jin-Su;Yang, Cheol-Woong
    • Applied Microscopy
    • /
    • 제46권3호
    • /
    • pp.164-166
    • /
    • 2016
  • Electron channeling contrast imaging (ECCI) is a powerful analyzing tool for identifying lattice defects like dislocations and twin boundaries. By using diffraction-based scanning electron microscopy technique, it enables microstructure analysis, which is comparable to that obtained by transmission electron microscopy that is mostly used in defect analysis. In this report, the optimal conditions for investigating crystal defects are suggested. We could obtain the best ECCI images when both acceleration voltage and probe current are high (30 kV and 20 nA). Also, shortening the working distance (6 mm) enhances the quality of defect imaging.

심장혈관조영촬영(心臟血管造影撮影)의 촬영조건(撮影條件)에 대(對)한 검토(檢討) (A Study on Optimum Technics in Angiocardiography)

  • 안봉선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제4권1호
    • /
    • pp.37-44
    • /
    • 1981
  • It is a experimental report to investigate optimum exposure technics in angiocardiography. Because of x-ray absorption and rapid voluntary motion in the heart region, it bound that discrimination ability of the exposed film is being decreased in ACG To circumvent these disadvantage it must be necessary to use short time exposure technics and also high capacity equipment in ACG. But in the case of using the low tube voltage to improve contrast on the exposed film, it will be result in a many difficulties in interpretation of the image due to increased contrast in vertebral images. Therefore the ranges 80 kVp to 90 kVp of could be suitable for the purpose of good contrast and an excellent discrimination ability and under this circumstance the optimum grid ratio for ACG was 8:1 to 12:1.

  • PDF

X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향 (Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus)

  • 이후민;윤준;김현주
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.187-193
    • /
    • 2014
  • 본 연구는 X선 진단장치의 고압정류방식이 그리드 성능을 측정하는 선택도(selectivity)와 대조도 향상능력(contrast improvement ability : K factor)에 미치는 영향을 분석하고자 산란선 함유율을 측정하였다. 정류방식이 서로 다른 X선발생장치를 대상으로 각 장치의 관전압과, 관전류량을 측정하여 출력선량의 정확도를 측정 및 교정한 후 각 장치별 노출조건을 동일하게 설정하고 형광량계를 이용하여 아크릴을 투과한 X선의 산란선 함유율을 측정하였다. Grid 미사용 시 피사체를 투과한 X선의 산란선 함유율 측정 결과는 단상정류방식장치에서 가장 낮은 함유율(34.158%)이 측정되었고, 인버터 정류방식(37.043%)과 삼상24피크 정류방식(37.447%)은 산란선 함유율이 증가하였다. 각 장치들의 산란선 함유율 차이는 최저 0.404%에서 최고 3.289%의 차이를 보였다. 8:1 Gird 사용 시 피사체를 투과한 X선의 산란선 함유율을 측정한 결과는 단상정류방식장치에서 가장 낮은 함유율(18.258%)로 측정되었고, 인버터정류방식(25.502%)과 삼상24피크정류방식에서 산란선 함유율(24.217%)이 증가하였다. 그리드 선택도에 따라 단상정류방식과 정전압(인버터와 삼상24피크)정류방식에서 산란선함유율의 차이는 최저 1.285%에서 최고 7.244%의 차이를 보였다. 통계분석 결과 단상정류방식 및 정전압정류방식에서 대조도 향상계수(K factor)에서도 유의한 차이를 보였다. 결론적으로 그리드 선택도와 대조도 향상계수는 정전압정류방식보다는 단상전파방식에서 모두 증가하여 그리드의 사용으로 선택도 향상과 대조도의 개선효과가 증가함을 알 수 있었다.

A New Pixel Structure for Active-Matrix Organic Light Emitting Diode

  • Choi, Sang-Moo;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.881-884
    • /
    • 2003
  • We propose a new pixel structure for Active Matrix OLED (AMOLED). The proposed pixel structure can display full color images by compensating threshold voltage (Vth) variation of driving TFTs. And we obtain an improved contrast ratio(C/R) of higher than 600:1

  • PDF

MCM/PCB 회로패턴 검사에서 SEM의 전자빔을 이용한 측정방법 (Characterization Method for Testing Circuit Patterns on MCM/PCB Modules with Electron Beams of a Scanning Electron Microscope)

  • 김준일;신준균;지용
    • 전자공학회논문지D
    • /
    • 제35D권9호
    • /
    • pp.26-34
    • /
    • 1998
  • 본 논문은 주사전자현미경(SEM)의 전자총을 이용하여 MCM 또는 PCB 회로기판의 신호연결선에서 전압차를 유도시켜 개방/단락 등의 결함을 측정 검사하는 방법을 제시한다. 본 실험에서는 주사전자현미경의 구조를 변형시키지 알고 회로기판의 개방/단락 검사를 실시할 수 있는 이중전위전자빔(Dual Potential) 검사방법을 사용한다. 이중전위전자빔(Dual Potential) 측정검사 방법은 이차전자수율 값 δ의 차이를 유기시키는 δ < 1 인 충전 전자빔과 δ > 1 인 읽기 전자빔을 사용하여 한 개의 전자총이 각각 다른 가속전압에 의해 생성된 두 개의 전자빔으로 측정하는 방법으로 특정 회로네트에 대한 개방/단락 등의 측정 검사가 가능하다. 또한 읽기 전자빔을 이용할 경우 검사한 회로 네트를 방전시킬 수 있어 기판 도체에 유기된 전압차를 없앨 수 있는 방전시험도 실시할 수 있어, 많은 수의 회로네트를 지닌 회로 기판에 대해 측정 검사할 때 충전되어 있는 회로네트에 대한 측정오류를 줄일 수 있다. 측정검사를 실시한 결과 glass-epoxy 회로기판 위에 실장된 구리(Cu) 신호연결선은 7KeV의 충전 전자빔으로 충전시키고 10초 이내에 주사전자현미경을 읽기 모드로 바꾸어 2KeV의 읽기 전자빔으로 구리표면에서의 명암 밝기 차이를 읽어 개방/단락 상태를 검사할 수 있었다. 또한 IC 칩의 Au 패드와 BGA의 Au 도금된 Cu 회로패드를 검사한 결과도 7KeV 충전 전자빔과 2KeV 읽기 전자빔으로 IC칩 내부회로에서의 개방 단락 상태를 쉽게 검사할 수 있었다. 이 검사방법은 주사전자현미경에 있는 한 개의 전자총으로 비파괴적으로 회로 기판의 신호 연결선의 개방/단락 상태를 측정 검사할 수 있음을 보여 주었다.

  • PDF

두께 변화에 따른 Gate Oxide의 전기적 특성 (The Electrical Properties of Gate Oxide due to the Variation of Thickness)

  • 박정구;홍능표;이용우;김왕곤;홍진웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1931-1933
    • /
    • 1999
  • In this paper, the current and voltage properties on the gate oxide film due to the variation of thickness are studied. The specimen is used for n-ch power MOSFET. It is shows the leakage current and current density characteristics due to the applied electric field when the oxide thickness is each $600[\AA],\;800[\AA]$ and $1000[\AA]$, respectively. We known that the leakage current is a little higher when the voltage as reverse bias contrast with forward bias in poly gate is applied. In order to experiment for AC properties is measured for capacitance characteristics. It is confirmed that the value of input capacitance have been a lot of influenced on $SiO_2$ thickness contrast with the value of output capacitance.

  • PDF