• 제목/요약/키워드: voltage capacity

검색결과 978건 처리시간 0.039초

선로사고 및 선로용량을 고려한 전력계통 최적운영에 관한 연구 (Study on the Calculation of the Optimal Power System Operation Considering Line Contingencies and Line Capacities)

  • 박영문;백영식;서보혁;신중린
    • 대한전기학회논문지
    • /
    • 제36권9호
    • /
    • pp.609-615
    • /
    • 1987
  • The optimal operation of power system is developed by alternately using real power dispatch and reactive power dispatch problem. The real power system scheduling process is formulated as an optimization problem with linear inequality constraints. A.C. loadflow method is used for the problem solution and line losses are considered. The constraints under consideration are generator power limits, load scehdling limits and line capacity limits. In solving the objective function the Dual Relaxation method is adopted. Tests indicate that the method is practical for real time application. The reactive power control problem uses the Dual Simplex Relaxation method as in the real scheduling case. Insted of minimizing the cost of power system, the objective is selected as to determine the highest possible voltage schedule. The constraints under consideration are the voltage limits at each node and the possibilities of supply or absobtion of reactive energy by generator units and the compensation facilities. Tests indicate that the method is practical for real time applications. The overall optimization methods developed in this paper proved to obtained fine results in minimizing object function compared with the method without using voltage control. And the overall voltage profiles were also improved.

  • PDF

유한요소법을 이용한 친환경 자동차용 고전압 커넥터 설계에 관한 연구 (A Study on the Design of High-Voltage Connector for Green Car using FEM)

  • 김성웅;최정욱;김형락;권영석;강남진;최경석;박형필;차백순
    • 한국정밀공학회지
    • /
    • 제28권6호
    • /
    • pp.716-723
    • /
    • 2011
  • The battery capacity of electric/hybrid vehicle is much larger than present automobile. For that reason, the connector of Green Car should be designed to transmit the high-electric voltage. In addition, the electromagnetic wave should be shielded to protect communication and signal circuits. In this study, shielding performance of the connector was analyzed through electromagnetic shield analysis, and a connector of Green Car was designed using thermoelectrical analysis, which is capable of transmitting the high-electric power. In the design of connector structure, the improved stability and workability was considered.

4-병렬 제어 기법을 적용한 6kW 영전압 스위칭 승압형 컨버터 개발 (Development of 6kW ZVS Boost Converter by 4-Parallel Operation)

  • 노민식
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.86-92
    • /
    • 2009
  • This paper presents development of 6kw ZVS(Zero Voltage Switching) boost converter by 4-parallel operation. To realize a high capacity converter with 6 kw, 4-parallel operation of 1.5kW unit module is proposed in this paper. To meet high ratio input to output voltage, isolated type booster converter is designed. To achieve ZVS operation of 4-switches of full bridge and protect a voltage overshoot caused by switch turn-off, simple active-clamp circuit is applied to the primary side. For parallel operation of 4-modules, master-slave control method is proposed to achieve input current sharing of 4-unit converter modules accurately. For performance tests, simulation is carried out. Also, load and experimental tests of the developed booster converter, 230Vdc/6kW, are carried out under various conditions. For field tests, the developed converter is applied for boosting a battery power to high DC_link voltage for a VSI inverter which starts a micro-turbine(MT) installed in vehicle and it's performance is verified through high speed motoring a MT up to tens of thousands of rpm.

병렬운전 변압기 전압제어 및 저압축 모선보호방식연구 (A Study of Voltage Control for Lower Side Parallel Transformer)

  • 윤기섭;백승도;최종혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.233-236
    • /
    • 2001
  • Parallel operation scheme to several transformers is adopted because of the load increase, economic problem, or load shedding. For the transformer's parallel operation, loads proportional to each transformer's capacity must be allotted, and circulation currents must be limited as much as without causing any problem in a real operation. But, both transformers in parallel operation can be tripped when either faults at lower voltage side of a transformer or faults in a bus occurs. Therefore, parallel operation scheme to distribution transformers in Korea is not adopted in a normal state but only when loaded or load-shedded. These are due to the insufficiency of the construction in communication network and AVR scheme. Besides that, those are because bus bar protection scheme to lower voltage side of a transformer is not applied. In spite of enormous initial investment costs, advanced countries take so much account of power system reliability and stable supply that they adopt the parallel operation scheme in a normal state. One of the problems in parallel operation is the overheat of transformers due to the excessive circulation currents. This paper presents the scheme that controls voltages between both transformers using circulation currents that occurs in parallel operation.

  • PDF

주택용 단상 ESS-PCS의 LC 필터위치에 따른 상용변압기의 특성 (Characteristics of Utility Transformer on Household Single-Phase ESS-PCS According to LC Filter Location)

  • 김용중;김효성
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.101-105
    • /
    • 2018
  • Shortage of electric power occurs frequently along with increased electric power demand. ESS is a precaution to solve this issue. Household ESS has a capacity of approximately 3 kW/7 kWh. Household ESS batteries are typically designed with nominal voltages between 40 and 50 V. To connect household ESS with a 220 V AC system, low battery voltages in power conditioning system (PCS) should be boosted. To boost low battery voltage and match it with AC grid voltage, the use of a transformer for a commercial frequency can be considered. To attenuate switching harmonics of the household single-phase ESS-PCS, LC filter can be installed in two positions: on the primary side or on the secondary side of a transformer. A method has been used generally in single-phase inverters for the ESS-PCS. In another method, however, the output efficiency of the ESS-PCS may be decreased. Parasitic components of the transformer can affect voltage losses, when the square wave with the switching frequency in the ESS-PCS is passed through the transformer windings. In this work, the characteristics of the transformer according to the position of an LC filter are investigated for household single-phase ESS-PCS.

PPTC 소자를 사용한 저전압 직류차단기의 아크소호기술 (Arc Extinguishment for Low-voltage DC (LVDC) Circuit Breaker by PPTC Device)

  • 김용중;나재호;김효성
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.299-304
    • /
    • 2018
  • An ideal circuit breaker should supply electric power to loads without losses in a conduction state and completely isolate the load from the power source by providing insulation strength in a break state. Fault current is relatively easy to break in an Alternating Current (AC) circuit breaker because the AC current becomes zero at every half cycle. However, fault current in DC circuit breaker (DCCB) should be reduced by generating a high arc voltage at the breaker contact point. Large fire may occur if the DCCB does not take sufficient arc voltage and allows the continuous flow of the arc fault current with high temperature. A semiconductor circuit breaker with a power electronic device has many advantages. These advantages include quick breaking time, lack of arc generation, and lower noise than mechanical circuit breakers. However, a large load capacity cannot be applied because of large conduction loss. An extinguishing technology of DCCB with polymeric positive temperature coefficient (PPTC) device is proposed and evaluated through experiments in this study to take advantage of low conduction loss of mechanical circuit breaker and arcless breaking characteristic of semiconductor devices.

Thyristor의 반파전압에 의한 특성분석에 관한 연구 (A Study on Analysis of Thyristors by the Half-sine wave Voltage)

  • 박호철;원학재;한승문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1327-1329
    • /
    • 2000
  • The thyristor among the power-semi-conductor elements, which has large current capacity and high voltage, is used widely nowadays. When the thyristor was being used to the long time, this element may be able to arise the system trip caused by changing the characteristic and dropping the performance. Therefore, it would be necessary to analyze the characteristic of element to maintain the stable operation of the system. In oder to analyze this characteristic, it would be need to test forward direction, reverse direction and leakage current by supplying the half-sine wave voltage. Among these testing, transient current condition is generated from the testing of leakage current. This transient current may be the main factor of the error in the precise measurement of leakage current. Therefore, this paper analyzes the relationship between supply voltage and transient current in measuring leakage current of the SCR, and then suggests the condition and cause of transient current as appearing the leakage current in the testing the leakage current.

  • PDF

도시철도 통합접지망에서의 위험전압에 따른 연접접지봉의 최적 분기간격에 관한 연구 (A Study on the Optimal Divergence Spacing of the Connecting Grounding Rod to the Dangerous Voltage in the Global Earthing Network of Urban Rail Transit)

  • 정호성;박영;김형철;김진희;김재문;조대훈
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1374-1379
    • /
    • 2012
  • Urban rail transit tends to global grounding system in order to control ground potential rise and potential differences between electric equipments. In addition, global grounding system can discharge the large capacity surge current to the ground safely. Since some railway electric equipments are installed all section of line, the global grounding system connected with the connecting grounding wire is more effectively. However, if the fault occurred in the connecting grounding wire area, some dangerous voltage is generated. So, the installation of additional grounding rod will be required. In this study, the global grounding system is simulated using CDEGS program to analyze the divergence spacing of additional ground rod depending on dangerous electric potential characteristics. Grounding net of the each station is modelled in depending on the size of the platform, and the spacing of the connecting grounding rod are compared 50m, 100m, 250m and 400m. Simulation results considering of earth resistivity and underground condition of the connecting grounding wire, spacing of the connecting grounding rod is that less than 250m to spacing of the ground rod was appropriately confirmed.

One Chip Microcomputer를 이용한 유도전동기 구동용 3동 전류형 인버어터시스템 (The Triple Current Source Inverter System for Induction Motor Drive Using a One Chip Microcomputer)

  • Chung, Yon-Tack;Jang, Seong-Chil;Hwang, Lak-Hoon;Lee, Hoon-Goo
    • 대한전기학회논문지
    • /
    • 제40권2호
    • /
    • pp.162-172
    • /
    • 1991
  • In proportion to the capacity enlargement of the induction motor system controlled by current source inverter, the capacitance of the commutating capacitor is enlarged and then the spike value of output voltage is increased at the moment of charge and discharge. Moreover, the output currnet includes a number of harmonic components. Such voltage spike and harmonics generate the torque ripple and lead to bad effects on the performance of the induction motor. In this study, all the harmonics excluding 17th and 19th harmonics were mostly elimunated by adopting 18-phase Triple High Frequency Current Source Inverter(HFCSI), and the spike component of output voltage was reduced by adding the Voltage Clamping Circuit(VCC). As a result, the torque ripple and the commutation loss were reduced and the performance of the system was improved. Experiments for speed control were carried out in the tripple current source inverter system for induction motor drive. Overall system was controlled by ONE CHIP MICROCOMPUTER(INTEL 8751). Control circuits were simplified and good experimental results in the constant V/F control were obtained due to the flexibility of the microcomputer.

  • PDF

SEPIC 컨버터를 이용한 형광등용 자려 발진형 전자식 안정기 개발 (Development of Self Oscillating Electronic Ballast for Fluorescent Lamp Using SEPIC Converter)

  • 김왕식;한재현;조계현;박종연
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.20-25
    • /
    • 2003
  • 본 논문은 기존 전자식 안정기에 사용되던 Boost 컨버터 형태의 역률 개선 부분을 SEPIC 컨버터 형태를 갖는 역률 개선 방식으로 대치하여 특성을 확인한 논문이다. Boost 컨버터 형태를 갖는 역률 개선 방식의 출력 DC 전압은 일반적으로 400[V]이며, 최소 전압은 입력 전원의 실효값 이상이어야만 한다. 하지만 SEPIC 컨버터 구조를 이용하면, 역율 개선 효과뿐만 아니라, 입력 전원의 실효값 보다 작은 출력 DC 전압을 얻을 수 있다는 장점을 가지고 있다. 본 논문에서는 SEPIC 컨버터 구조를 갖는 역율 개선 방식과 링코어를 이용한 자려식 발진 방식을 적용한 전자식 안정기를 제작하였고, 낮은 출력 전압을 이용하여 소자의 용량과 크기를 감소시켰다.