• Title/Summary/Keyword: voltage capacity

Search Result 978, Processing Time 0.03 seconds

Fabrication and Characteristics of Transformers for High Power Density SMPS (고밀도 SMPS 용 변압기의 제조와 특성)

  • Kim, Hyun-Sik;Kim, Jong-Ryung;Huh, Jung-Sub;Oh, Yong-Woo;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.7-10
    • /
    • 2002
  • We designed the flyback planar transformer, which had 8W capacity, with 70V input voltage and 8.2V output voltage for the establishment of design method and the confirmation of application possibility. The numerical value of inductance measured under the switching frequency of 120 kHz was 1650 ${\mu}H$, which was the inductance efficiency of 85~87% against theoretical value. The A.C. resistance of primary and secondary coil was 4.2 ${\Omega}$ and 0.25 ${\Omega}$ respectively. On the other hand, the quality factor for each wound numbers showed quite a high value of 158 and 75 respectively. And the Coupling Factor was 0.96~0.97 under 120 kHz switching frequency. And the shape of the output wave of the planar transformer at 70V input voltage was a stable square wave.

  • PDF

Analysis and optimization of Wiel-Dobke synthetic testing circuit parameters (Weil-Dobke 합성단락 시험회로의 Parameter 분석과 최적화)

  • Kim, Maeng-Hyun;Rhyou, Hyeong-Kee;Park, Jong-Wha;Koh, Hee-Seog
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.623-627
    • /
    • 1995
  • This paper describes analysis and optimization of Weil-Dobke synthetic testing circuit parameters, which is efficient and economical test method in high capacity AC circuit breaker. In this paper, analysis of synthetic short-circuit test circuit parameter proposed nondimensional factor that is reciprocal comparison value of circuit parameter and is not related to rated of circuit breaker, in particular, this study induce minimization of required energy of critical TRV generation specified in IEC 56 standards and present optimal design of synthetic short circuit testing facilities.

  • PDF

Conceptual Design of an HTS large power transformer with continuously transposed coated conductors

  • Lee, Se-Yeon;Park, Sang-Ho;Kim, Woo-Seok;Lee, Ji-Kwang;Park, Il-Han;Chol, Kyeong-Dal;Hahn, Song-Yop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.2
    • /
    • pp.5-8
    • /
    • 2011
  • This paper shows results of a design work of a program that is to develop a large power single phase high temperature superconducting (HTS) transformer. The program forms a part of a national project in Korea. A target of the design work is an HTS power transformer with rated voltages of 154 kV/22.9 kV and material for windings is supposed to be coated conductor. The design results presents in this paper will include: 1)HTS winding structures for high voltage in liquid nitrogen, 2)design result of continuously transposed coated conductor (CTCC), 3)conceptual design of high voltage bushings, 4)cooling system. A feasibility study will succeed to this design work for construction of a prototype HTS power transformer with capacity/voltage of 33 MVA/154 kV.

A Study on the Optimal PV-module Design for Efficiency Improvement of Photovoltaic System (태양광발전시스템의 효율 향상을 위한 태양전지 모듈의 최적 설계에 관한 연구)

  • Kim, Min;Lee, Gi-Je;Lee, Jin-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.328-330
    • /
    • 2001
  • The construct of photovoltaic module array, main power source of photovoltaic system, is very important to the efficiency improvement of whole photovoltaic system. Photovoltaic modules are usually connected in series or parallel to meet power capacity required. Since output characteristics of a photovoltaic module are greatly fluctuated on the variation of insolation, temperature and its type, the maximum open circuit voltage and output operating voltage of photovoltaic module array must exist in the admissible input voltage range of inverter system under any operating conditions. In this paper, we present the selection and array method of photovoltaic modules through simulation for the coupling loss reduction between photovoltaic modules and a inverter.

  • PDF

Optimal Operation of Reactive Power Compensation Devices for Voltage Control of Emegency Status (비상상태 전압제어를 위한 무효전력보상설비의 최적 운용)

  • Ahn, Chang-Han;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.661-666
    • /
    • 2015
  • This paper proposes a method for solving running cost problem by minimizing switching reactive power compensation devices. An objective function was modeled by calculating the weighting value of cost, and a solution was derived using ILP. This paper suggests optimal coordinative control method between FACTS, Shunt Reactors, Capacitors and OLTC. Therefore, it is valuable for decision maker in determining order and capacity of devices which gaining a voltage stabilization. As a result, the objectives of voltage stabilization and cost minimization were achieved simultaneously. This realizes the economic efficiency of the system. We start by showing how to solve systems of linear equations using the language of pivots and tableaus. The effectiveness of this technique is demonstrated in modified PSS/E MIGUM 45 bus system. The simulation results show the effectiveness of this algorithm by comparing the outcome withseveral established methods.

Auxiliary Power Unit Control Algorithm for Input Voltage Disturbance Suppression (입력 급변 대응을 위한 철도 차량용 보조전원장치 외란 억제 알고리즘 구현)

  • Kim, Ji-Chan;Baek, Seoung-Gil;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1810-1817
    • /
    • 2015
  • The railway vehicle has an auxiliary power unit for supplying power to the associated electronic control devices and passenger service unit. Typically, input voltage from the catenary for rolling stock is highly fluctuating according to the substation capacity, vehicle propulsion and regeneration. Especially, the frost and freezing on contact wire in winter can cause a blackout inside vehicle, and also brings about electronic components damaging and the system down. To prevent this problem, a large filter and capacitor is used. But this is not a perfect solution, because it is increasing weight of the unit. In this paper, a new algorithm is proposed to suppress the disturbance without adding devices. Simulation and experimental results show that the proposed algorithm has performance to suppress the disturbance at the sudden input voltage variations.

The Selection of the Condenser Positions for the Improvement Power Factor of the High Voltage Induction Motors (고압유도전동기의 역률개선을 위한 콘덴서 위치 선정 방안)

  • Lee, Eun-Chun;Jeon, Il-Bang;Kim, Chang-Bum;Choe, Yeong-Gyu;Shin, Kang-Uk;Hong, Sung-Taek;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1068-1070
    • /
    • 2005
  • This study sorted high voltage motors by the voltage and the capacity and analyzed the property of motor-start. So we found out some problems of the starting circuit from several sites, and made the answers of the problems. If these results of our study are utilized in new WTPs, the safety of the starting circuit will be improved and the life of electric power system will be longer. We recommend this study as a reference when our company founds the standard of electric facility design.

  • PDF

220Vrms Series Arc Characterization Depending on load capacity For Arc Fault Detection (아크사고 검출을 위한 부하용량별 220Vrms 직렬아크특성)

  • Choi, Su-Kyung;Kwon, Wan-Sung;Kim, Chong-Min;Bang, Sun-Bae;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.213-214
    • /
    • 2010
  • The Arc fault is primary reason of electric fire. so we must detect. the purpose of this study is to extend our knowledge of AC-arc characteristics and detect. The Arcs are produced by separating two electrodes made with graphite and copper. A very low separation speed allows arcs to reinitiate, as in arc fault in wires. Power is 220Vrms-60Hz and the load is light bulbs and capacities are 220W, 660W and 1100W. I measured Arc voltage and current. and defined voltage and current Max level, voltage plateau and Arc-power at each cycle.

  • PDF

A Program for Short-Circuit Capacity Calculations of Low-Voltage Circuit using the VISUAL BASIC (VISUAL BASIC을 이용한 저압회로의 단락용량계산 프로그램 개발)

  • Choi, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.94-102
    • /
    • 2007
  • With the recent expansion of electric capacity, troubles in the electric system threatening the stable electricity supply are rapidly increasing. However, most of the current short-circuit capacity calculations have been made manually. This research focuses on the development of a program which uses the Visual Basic. We can obtain the stability in the system diagram and the reliability of the loaded facilities by calculating an exact breaking capacity for each electric facility with this method. We expect that this research can be widely used for the design and construction of the electric facilities in the future.

A Study on the Development of Single-phase Linear Induction Motor (단상 Linear Induction Motor의 개발연구)

  • Dal Ho Im
    • 전기의세계
    • /
    • v.26 no.5
    • /
    • pp.65-73
    • /
    • 1977
  • This paper work treats with the basic characteristics to be investigated in development of a single-phase linear induction motor. The results of this research work have established some important characteristics which should be taken into consideration in the design and construction of this linear motor, And it is also proven that the development of high-voltage linear machine with large capacity is possible.

  • PDF