• 제목/요약/키워드: voltage capacity

검색결과 978건 처리시간 0.035초

전압조정 측면에서 본 소형 열병합발전 배전계통 도입량 평가 (Evaluation of Interconnection Capacity of SCOGNs to the power Distribution Systems from the Viewpoint of Voltage Regulation)

  • 최준호;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권9호
    • /
    • pp.1096-1102
    • /
    • 1999
  • This paper discusses the evaluation of interconnection capacity of small cogeneration(SCOGN) systems to the power distribution systems from the viewpoint of voltage regulation. Power utilities are required to keep the customers' voltage profile over a feeder close to the rated value under all load conditions. However, it is expected that the interconnection of SCOGNs to the power distribution systems impacts on the existing voltage regulation method and customers' voltage variations. Therefore, SCOGNs should be integrated to the automated power distribution systems to prevent interconnection problems and supply high quality electricity to the customers. For these reasons, we should proceed with the evaluation of interconnection capacity of SCOGNs to the power distribution systems. However, it is generally impossible to perform actual testing on the power distribution systems, and standardized methodologies and guidelines are not developed to evaluate it. The criterion indexes for voltage regulation and variations are presented in order to evaluate the interconnection capacity of SCOGNs to the power distribution systems. In addition, the evaluation methodology of interconnection capacity of SCOGNs for power distribution systems is presented. It is expected that the resulted of this paper are useful for power system planners to determine the interconnection capacity of SCOGNs and dispersed storage and generation (DSG) systems to the power distribution systems.

  • PDF

전기철도 일형식 부하 크기에 따른 전압강하 측정 및 분석 (Test and Analysis of Voltage Drop according to Load Capacity in Traction Power Supply System)

  • 김주락;장동욱;창상훈;이영흠
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.940-947
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

전압안정도를 고려한 경제적인 발전가능전력의 산정알고리즘에 관한 연구 (A Study on Assesment Algorithm for the Economical Generation Capability considering Voltage Stability)

  • 문현호;이종주;윤창대;안비오;최상열;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.536-543
    • /
    • 2006
  • This paper uses Monte Carlo technique, which is one of probabilistic methods of estimating the economical quantity of electric power generation in consideration of voltage stability in the aspect of power generation companies. In the power exchange system in Korea, when power generation companies participate in tenders for power generation capacity at the power exchange, they need to determine their power supply capacity considering the stability of electric power system. Thus, we purposed to propose an algorithm for estimating economical power generation capacity in theaspect of power generation companies, through which we can estimate the margin for voltage stability through P-V curve analysis by capacity according to the change of power generation capacity in a simulated system and to conduct Monte Carlo simulation in consideration of the margin

전압변동과 부하량을 고려한 저압배전계통의 분산전원 설치용량 분석 (The Study on Permissible Capacity of Distributed Generation Considering Voltage Variation and Load Capacity at the LV Distribution Power System)

  • 문원식;조성민;신희상;이희태;한운기;추동욱;김재철
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.100-105
    • /
    • 2010
  • This paper describes a capacity of distributed generation which will be interconnected at low voltage distribution systems. In order to set the capacity of distributed generation, a voltage variation of distribution system is considered. Besides, the capacity of distributed generation is classified according to a capacity of pole transformer and loads. The system constructions in this paper are analyzed by using PSCAD/EMTDC. In the immediate future, it is expected to increase the installation of New and renewable energy systems which are generally interconnected to distribution power systems in the form of distributed generations like photovoltaic system, wind power and fuel cell. So the study of this kind would be needed to limit the capacity of distributed generation.

전기철도 급전시스템의 안정화를 위한 전압강하 측정 결과 분석 (Measurement and Analysis of Voltage Drop in Traction Power Supply System)

  • 김주락;이영흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2210-2211
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

배전계통의 전압조정기 운영방법에 따른 분산형전원 최대 도입 용량 산출 (The Maximum Installable DG Capacity According to Operation Methods of Voltage Regulator in Distribution Systems)

  • 김미영
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1263-1269
    • /
    • 2009
  • Stable and sustainable power supply means maintaining a certain level of power quality and service while securing energy resource and resolving environmental issues. Distributed generation (DG) has become an essential and indispensable element from environmental and energy security perspectives. It is known that voltage violation is the most important constraint for load variation and the maximum allowable DG. In distribution system, sending voltage from distribution substation is regulated by ULTC (Under Load Tap Changer) designed to maintain a predetermined voltage level. ULTC is controlled by LDC (Line Drop Compensation) method compensating line voltage drop for a varying load, and the sending voltage of ULTC calls for LDC parameters. The consequence is that the feasible LDC parameters considering variation of load and DG output are necessary. In this paper, we design each LDC parameters determining the sending voltage that can satisfy voltage level, decrease ULTC tap movement numbers, or increase DG introduction. Moreover, the maximum installable DG capacity based on each LDC parameters is estimated.

전압 불평형시 콘덴서 전압, 전류, 용량 특성 해석 (Characteristics Analysis for Voltage, Current & Capacity of Condenser at Voltage Unbalance)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.145-151
    • /
    • 2010
  • 전압 불평형은 수용가 설비에서 상당히 중요한 전기 품질의 하나로 간주되고 있다. 전압은 송전선로 계통에서는 평형에 가깝지만, 수용가에서의 전압 레벨은 시스템 임피던스의 불평형과 단상 부하의 고르지 못한 배분 등으로 인해 불평형이 될 수 있다. 콘덴서는 역률 보상으로도 사용되며, 비선형 부하에서 발생하는 고조파를 저감하기 위해 리액터와 함께 사용되고 있다. 전압 불평형이 존재할 경우 전류 불평형으로 콘덴서에서는 용량변화가 일어난다. 콘덴서와 리액터를 함께 사용하는 경우 사고 발생이 높은 편이다. 그래서 콘덴서 설비에 전압 불평형이 존재할 경우 전압, 전류 그리고 용량의 변화가 어떻게 진행되는지 확인하는 것이 매우 중요하다. 본 연구에서는 전압 불평형률이 존재할 경우 콘덴서 단독운전과 리액터의 부착시 전압, 전류 및 용량의 크기가 규정에서 제시한 범위 이내인지를 계산하였다.

ULTC 와 SVR 이 설치된 배전계통에서 LDC Parameters 을 고려한 최대 DG 용량 산정 (The Installable Maximum DG Capacity Considering LDC Parameters of ULTC and SVR in Distribution Systems)

  • 김미영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.27-28
    • /
    • 2008
  • For stable and sustainable energy supply, distributed generator (DG) has become an essential and indispensable element from environmental and energy security perspectives. However, installation of DG in distribution systems may cause negative affects on feeders because power outputs of DG could be changed irregularly. One of major negative affects is variation in voltage profile. In general, voltage regulation devices such as under load tap changer (ULTC) at distribution substation and step voltage regulator (SVR) along feeder in distribution system are used to maintain customers' receiving voltage within a predetermined range. These regulators are controlled by line drop compensation (LDC) method which calls for two parameters; the equivalent impedance and the load center voltage. Therefore, consideration of DG outputs in the LDC parameter design procedure may give large impact on the installable DG capacity. This paper proposes a method that estimates maximum Installable DG capacity considering LDC parameters of ULTC and SVR. The proposed algorithm is tested with model network.

  • PDF

활성탄 종류에 따른 아연공기전지용 Cathode의 전기화학적 특성 연구 (A Study on the Electrochemical Properties of the Cathode upon Different Kinds of Activated carbon in Zinc/Air Battery)

  • 김지훈;엄승욱;문성인;윤문수;김주용;박정식;박정후
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.415-421
    • /
    • 2004
  • The voltage profile of Zinc/Air battery during discharge has very flat pattern in a given voltage range, But, if not enough the porosity in cathode, as a result of that capacity, energy and discharge voltage of batteries become low. Therefore, we focused the pore effects in activated carbon for cathode. We examined discharge voltage, specific capacity, specific energy, resistance and characteristics during the GSM pulse discharge upon different kinds of activated carbon in Zinc/Air battery, Also we measured porosity of the air cathode according to the ASTM. So we achieved improvement of specific capacity, specific energy and discharge voltage according to increase meso pores of activated carbon. We found the optimized activated carbon material for Zinc/Air battery.

EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석 (Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP)

  • 권영목;김재철
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.82-93
    • /
    • 2006
  • 본 논문에서는 인버터 구동 고압유도전동기 운전시 스위칭 서지로 인하여 고압유도 전동기 단자에서 발생하는 과도과전압을 저감하기 위한 필터로 인버터 출력단자에서 dv/dt를 저감하는 LCR 필터와 전동기 입력단자에서 케이블과 유도전동기 특성임피던스를 매칭시키는 RC필터에 대한 과도과전압 저감특성을 분석하였다. 이 필터를 고압에 대용량 유도전동기에 적합하도록 EMTP(ElectroMagnetic Transients Program)를 이용하여 모델링 및 케이블 영향에 의한 필터의 과도과전압 저감효과를 전압파형과 고조파 스펙트럼으로 비교분석하고, 이를 토대로 고압 대용량 유도전동기에 사용될 필터를 제시하였다. 인버터 스위칭 서지에 의한 과도과전압은 유도전동기 고정자 권선에 심각한 전압 스트레스를 발생시켜 절연파괴를 일으키는 주요원인이 된다. 이러한 과도과전압을 저감위한 필터설계는 고압유도전동기 시스템에서 필수적인 요소임을 보였다. 또한 제시된 필터는 과도과전압을 효과적으로 저감시키는 것을 EMTP 시뮬레이션을 통하여 입증하였다.