• 제목/요약/키워드: voltage and frequency controller

검색결과 403건 처리시간 0.024초

다수 개 디스크 PZT 를 이용한 밸브리스 압전펌프의 연동구동 파형에 관한 연구 (A study on the peristaltic waveform of valveless PZT pump using disk type multi PZTs)

  • 함영복;박중호;윤동현;김한석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1824-1827
    • /
    • 2005
  • For application to micro fluid control systems such as ${\mu}TAS$ (Micro Total Analysis Systems) and DDS (Drug Delivery Systems), it is very significant to handle precise and minute flow rates with low pressure pulsation. In this study, a novel valveless piezoelectric pump using peristaltic motion with three disk type PZT actuators is presented. The newly devised pump with an effective size of $70mm{\times}60mm{\times}55mm$ has three actuator layers connected in series from inlet to outlet. The PZT actuator has a maximum displacement of 240 ${\mu}m$ and a maximum force of 1.6 N. When the driving voltage for PZT actuators is sequentially applied with a certain phase shift, the pumping is performed by peristaltic motion of liquid volume. The working fluid is shut off without the driving voltage. Three methods for sequential driving are proposed and experimentally investigated. First and second methods utilize an intermittent sinusoidal waveform with phase shift of $90{\circ}\;and\;120^{\circ}$, respectively. Third method uses a rectangular waveform with phase shift of $90^{\circ}$. A controller with multi-phase shifter is designed and fabricated. Then, frequency and voltage-flow rate characteristics and load pressure-flow rate characteristics are experimentally investigated to verify the validity of the developed pump.

  • PDF

GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구 (A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System)

  • 김성주;장석훈;조국희
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현 (Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis)

  • 김성철
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5403-5408
    • /
    • 2012
  • 본 논문에서는 신체 성분 분석을 위한 다주파수 생체전기 임피던스 분석법에 대하여 소개하고 이를 기반으로 다주파수 생체전기 임피던스 분석 시스템을 구현하고 그 과정 및 결과를 제시하였다. 시스템의 구성요소들을 다주파수 교류 신호 발생부, 위상 신호 검출부, 전압 신호 검출부, 제어부, 입 출력부, 전극부, 전원부로 구분하여 설명하고, 구체적으로 구현 기법을 소개하였다. 체성분 데이터의 임상적 의의를 검토하고자 세계 최고 수준의 기술을 적용하여 높은 재현도와 고정밀도의 데이터를 제공하는 전문가용 체성분 분석기로 측정한 데이터와 비교 검토하고 두 측정치간의 상관관계를 구한 결과 시스템에 의한 체성분 분석은 상당히 높은 재현성을 나타낸다고 할 수 있다.

인치웜 리니어 모터 시스템 설계 및 제작에 관한 연구 (A Study on Design and Manufacture of an Inchworm Linear Motor System)

  • 예상돈;정재훈;민병현
    • 한국정밀공학회지
    • /
    • 제21권12호
    • /
    • pp.174-181
    • /
    • 2004
  • Ultra precision positioning mechanism has widely been used on semiconductor manufacturing equipments, optical spectrum analyzer and cell manipulations. Ultra precision positioning mechanism is consisted of several actuators, sensors, guides and control systems. Its efficiency depends on each performance of components. The object of this study is to design, analysis and manufacture all of the inchworm linear motor system, which is one of the equipments embodied in ultra precision positioning mechanism. Inchworm linear motor system is consisted of a controller system and an inchworm linear motor, and its driving form is similar to a motion of spanworm. A design and manufacture of inchworm linear motor, which is consisted of three PZT actuators, a rod, two columns and a guide plate, are performed. Minimizing the von-Mises stress of the hinge using Taguchi method and simulation by FEM software optimizes the structural design in a column of flexure hinge. The designed columns and guide plates are manufactured by a W-EDM and NC-milling. A controller system, which is an apparatus to drive inchworm linear motor, can easily adjust driving conditions by varying resonance frequency and input-output voltage of actuators and amplifiers. The performance of manufactured inchworm linear motor system is verified and valuated. In the future, inchworm linear motor system will be used to make a more precision positioning by reinforcing a sensor and feedback system.

전동기 구동 시스템의 왜형률 가시화에 의한 전력 파라미터 분석 및 평가 (Power Parameters Analysis and Evaluation using Visualization of Distortion Factor for Motor Drive System)

  • 임영철;정영국
    • 전력전자학회논문지
    • /
    • 제3권1호
    • /
    • pp.15-22
    • /
    • 1998
  • 전동기의 전기적/기계적 파라미터 측정에 관한 연구는 브리시리스 전동기 적용에 까지, 비교적 오랜기간에 걸쳐 체계적인 연구가 진행되어져 왔다. 그러나 효율적인 전기 에너지 관리를 위해 전동기 구동시스템의 전력 파라미터의 분석 및 평가에 관한 체계적인 연구는 미진한 형편이다. 따라서 본 연구에서는 PC 화면상에 다양한 그래픽 화면과 수치로 디스플레이 가능한 사용자 위주의 전동기 구동장치의 전력 파라미터 분석 및 평가법을 제안하고 시스템을 개발하였다. 분석 및 평가시스템은 586-PC, DSP보드, 전력 파라미터의 분석 및 평가 소프트웨어 및 전동기 구동시스템으로 구성되어 있다. 전력 파라미터는 전압, 전류파형의 상호상관함수 알고리즘에 의해 분석되며, 이 분석 알고리즘을 DSP가 전담하여, 전력 파라미터를 실시간 분석하였다. 3차원 전류좌표계에 의하여 분석결과의 가시화를 행하였으며, 종래의 시간/주파수 영역에서의 2차원적인 평가법과 비교하였다. 적용대상 전동기로는 기동 토오크가 크며, 역률, 효율이 좋다는 장점 때문에 널리 이용되고 있는 단상 캐패시터 구동형 유동 전동기와 싸이리스터로 제어되는 구동 시스템을 선정하였다. 캐패시터 구동형 단상 유동전동기의 속도제어를 위하여 싸이리스터의 위상각을 변화시켰으며, 위상각 변화에 따른 전동기의 전력 파라미터를 분석 평가하여 본 연구의 유용성을 확인하였다.

Feedback control strategies for active control of noise inside a 3-D vibro-acoustic cavity

  • Bagha, Ashok K.;Modak, Subodh V.
    • Smart Structures and Systems
    • /
    • 제20권3호
    • /
    • pp.273-283
    • /
    • 2017
  • This paper presents and compares three feedback control strategies for active control of noise inside a 3-D vibro-acoustic cavity. These are a) control strategy based on direct output feedback (DOFB) b) control strategy based on linear quadratic regulator (LQR) to reduce structural vibrations and c) LQR control strategy with a weighting scheme based on structural-acoustic coupling coefficients. The first two strategies are indirect control strategies in which noise reduction is achieved through active vibration control (AVC), termed as AVC-DOFB and AVC-LQR respectively. The third direct strategy is based on active structural-acoustic control (ASAC). This strategy is an LQR based optimal control strategy in which the coupling between the various structural and the acoustic modes is used to design the controller. The strategy is termed as ASAC-LQR. A numerical model of a 3-D rectangular box cavity with a flexible plate (glued with piezoelectric patches) and with other five surfaces treated rigid is developed using finite element (FE) method. A single pair of collocated piezoelectric patches is used for sensing the vibrations and applying control forces on the structure. A comparison of frequency response function (FRF) of structural nodal acceleration, acoustic nodal pressure, and piezoelectric actuation voltage is carried out. It is found that the AVC-DOFB control strategy gives equal importance to all the modes. The AVC-LQR control strategy tries to consume the control effort to damp all the structural modes. It is seen that the ASAC-LQR control strategy utilizes the control effort more intelligently by adding higher damping to those structural modes that matter more for reducing the interior noise.

UHF 대역 공진 주파수 및 반사 손실 오토튜닝 마이크로스트립 안테나 설계 (Design of UHF Band Microstrip Antenna for Recovering Resonant Frequency and Return Loss Automatically)

  • 김영로;김용휴;허명준;우종명
    • 한국전자파학회논문지
    • /
    • 제24권3호
    • /
    • pp.219-232
    • /
    • 2013
  • 본 논문에서는 손과 같은 물체가 안테나에 접근하였을 때 이탈된 공진 주파수와 임피던스를 자동으로 복원하여 무선기기의 송수신 성능을 항상 최적의 상태로 유지하도록 할 수 있는 UHF 특정 소출력 무선주파수 대역(425 MHz)의 소형 마이크로스트립 안테나를 설계, 제작하였다. 반파장 마이크로스트립 방사체의 양쪽 끝단을 접지면 쪽으로 폴딩하여 소형화하고, 역시 방사체와 접지면 사이에 바랙터 다이오드에 의한 캐패시턴스를 장하한 다음, 각각 역바이어스 전압 조절에 의한 용량을 비대칭적으로 변화시킴으로써, -30 dB 이하의 일률적인 반사 손실을 유지하면서 395 MHz에서 455 MHz까지 연속적인 공진 주파수 조절이 가능한 전압 제어 안테나를 설계하였다. RF 모듈로부터 시험 신호를 안테나에 송출하여, 부정합에 의해 안테나로부터 되돌아 온 반사 신호 레벨을 RSS(Receive Signal Strength) 검출 회로와 오프셋 증폭기를 통하여 마이크로콘트롤러에 입력하고, 그 레벨이 최소가 되도록 안테나의 바이어스 전압을 자동 조절하는 펌웨어를 설계, 시스템을 완성하여 시험한 결과, 손, 금속판, 유전체 등의 물체를 접근시켰을 때 틀어졌던 안테나의 특성이 수 초 이내에 완전하게 복원됨을 확인하였다.

An Enhanced Power Sharing Strategy for Islanded Microgrids Considering Impedance Matching for Both Real and Reactive Power

  • Lin, Liaoyuan;Guo, Qian;Bai, Zhihong;Ma, Hao
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.282-293
    • /
    • 2017
  • There exists a strong coupling between real and reactive power owing to the complex impedances in droop based islanded microgrids (MGs). The existing virtual impedance methods consider improvements of the impedance matching for sharing of the voltage controlled power (VCP) (reactive power for Q-V droop, and real power for P-V droop), which yields a 1-DOF (degree of freedom) tunable virtual impedance. However, a weak impedance matching for sharing of the frequency controlled power (FCP) (real power for $P-{\omega}$ droop, and reactive power for $Q-{\omega}$ droop) may result in FCP overshoots and even oscillations during load transients. This in turn results in VCP oscillations due to the strong coupling. In this paper, a 2-DOF tunable adaptive virtual impedance method considering impedance matching for both real and reactive power (IM-PQ) is proposed to improve the power sharing performance of MGs. The dynamic response is promoted by suppressing the coupled power oscillations and power overshoots while realizing accurate power sharing. In addition, the proposed power sharing controller has a better parametric adaptability. The stability and dynamic performances are analyzed with a small-signal state-space model. Simulation and experimental results are presented to investigate the validity of the proposed scheme.

d-q 변환에서의 고조파 맥동 제거 (A Rejection of Harmonic Ripples for d-q Transformation)

  • 최남열;이치환
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.83-87
    • /
    • 2015
  • This paper presents a simple notch filter, which is so suitable for three-phase unbalanced and distorted power line. In the d-q synchronous transformation, three-phase unbalanced and distorted voltages generate lots of ripple voltages on d-q axes. The ripples make disturbances on controllers such as PLL of phase tracking. Unbalanced state makes ripple of double the frequency of power line. Odd harmonics 5th and 7th on the line make even 4th and 6th ripples on d-q axes due to the rotating reference frame, respectively. Cascaded two comb filters, delay lines 1/4T and 1/8T, are adopted for the ripple rejection. The filter rejects harmonics 2nd, 4th, 6th, 10th and so on. They are very effective to remove the ripples of both unbalance and distortion. The filter, implemented by two FIFOs on an experimental system, is adopted on a PLL controller of power line phase tracking. Through the simulation and experimental results, performance of the proposed comb filter has been validated.

교통신호의 자동최적점제어를 위한 마이크로파 FM-CW 검지계통에 관한 연구 (A Study on Microwave-FM-CW Detection System for the Sutomatic Optimal Point Traffic Control)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • 제22권1호
    • /
    • pp.35-41
    • /
    • 1973
  • An automatic point traffic control method is recommended for more idealistic traffic flow over coarse road netowrks. The automatic control apparatus recommended, consists of a transceiver, amplifier, digital-to-analog converter, signal light controller for emergency and steady state, and digital counter as monitor. The transmitter sends a signal to the target vy means of Microwave-FM-CW and a diode detector picks up the echo signal. Thus the operation of the entire system will be carried out through an open loop state. Some factors necessary for an ideal detector system are rapid response, longevity and stability. An analytical method of the Doppler effect substitutes the conventional frequency deviation into the amplitude of detector output. The changing rate of amplitude is proportional to the voltage of the detector output. Some induced formula from Maxwell's radiation field theory ensures this new method, and, new method, and proves the fact with an experimental data presentation. Stability depends upon Klystron as an oscillator and a diode as a detector. the transceiver installation affects on the response and sensitivity of the system. In accordance with the detector output, several targets are easily classified by amplitudes on the scope. The traffic flow, i.e., target movement which is analyzed by the amplitude method, is shown through the scope and indicates it on the digital counter. The best efficiency for the amplitude analysis can be attained through use of an antenna having the highest sensitivity.

  • PDF