• Title/Summary/Keyword: volatile substances

Search Result 316, Processing Time 0.021 seconds

Qualities of distilled liquor using Saccharomyces cerevisiae 88-4 separated from traditional Nuruk (전통누룩에서 분리한 효모 88-4로 제조한 술의 증류 특성)

  • Lee, Dae-Hyoung;Lee, Yong-Seon;Seo, Jae-Soon;Won, Seon-Yi;Cho, Chang-Hui;Park, In-Tae;Kim, Tae-Wan;Kim, Jae-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.3
    • /
    • pp.279-285
    • /
    • 2017
  • This study reviews the manufacturing characteristics of distilled liquor prepared using Saccharomyces cerevisiae 88-4 separated from traditional Nuruk. From analysis of soju mash (sool-dut) during the fermentation process, 17.2% of alcohol was detected in the final fermentation with succinic acid present at the highest level ($7,164.3{\pm}85.2ppm$). From the analysis of alcohol content in different distillation conditions, distillation condition No. 6 showed the lowest amount of alcohol ($29.6{\pm}0.0%$), whereas distillation condition No. 4 showed the highest amount ($59.9{\pm}0.1%$). N-propanol has been detected at the highest level in distilled liquor under conditions No. 1 and 4, each being $163.4{\pm}18.3$ and $174.0{\pm} 0.1ppm$, respectively. Isobutanol showed a tendency similar to n-propanol. Distilled liquor in conditions No. 1 and 4 has shown the highest acetaldehyde level, each being $303.4{\pm}4.5$ and $325.4{\pm}13.1ppm$, respectively. After distillation, 14 volatile substances were found in common, with isoamyl alcohol present at the highest levels in all the distilled liquors. Distillation conditions No. 3, 5, 6, and 7 have shown high levels of isobutanol that emits a banana-like fragrance and ethyl octanoate that emits a pleasant fruity and floral fragrance.

A Study on the Water Quality of Reservoir Tank in the Building Complex on Jeonnam Area (대형건축물 저수조의 수질실태 및 개선방안에 관한 연구)

  • Lee, J.H.;Lee, H.H.;Kim, H.B.;Ahn, G.W.;Park, K.N.;Kim, Y.K.;Bae, J.S.;Mun, H.;Park, C.U.;Oh, E.H.;Park, S.I.;Seo, Y.G.
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.59-77
    • /
    • 2000
  • This study was carried out to investigate on several factors, which contaminative the water quality through the water pipe during feeding water, in 42 largescaled apart-ments(total 84 cases) and assayed the Volatile Organic Compounds(VOCs) and concen-tration of heavy metals that inflow and outflow in reservior water in Jeonnam area(Mokpo, Suncheon, Yeosu) from January 1999 to December 1999. The results obtained were summarized as follows ; 1. The quality of the water pipe composition in the order of frequency in the quality of water pipes were Copper(45.2%)> Zinc(38.9%)> Stainless steel(9.5%)> PVC(4.8%)> PM(2.4%) in observing 42 sites. All of the drain pipes were used the cast iron quality. 2. The result of certification curve from 12 items(17kind) of VOCs was $1.0-4.0{\mu{g}}/{\ell}$ range, a coefficient of correlation was shown 0.99 over. A MDL of each substance range was within $0.1-1.0{\mu{g}}/{\ell}$. 3. The result of the assay, 5 kinds(Viny chloride, Dichloromethane, Ethylbenzene, M,P-xylene, Styrene) of the VOCs of 14 kinds was not detected and the other items were detected slightly. The detection rate of one item and over in total VOCs samples, were 25.9% in inflow and 27.9% in outflow. And frequency of detect in inflow/outflow of THM(Chloroform, Bromodichloro-methane, Dibromochloromethane, Bromoform) were shown higher than 94.1%, 97.0% each stages. It comes to the conclusion that all of the samples were reason able for drinking water standards. 4. The coefficient of correlation were reasonable, it shown 0.999 over in $0.1-1.0{\mu{g}}/{\ell}$ of a measuring range conditions of 4kinds in organic substance(Zn, Cu, Fe, Mn). 5. The results were showed suitability in 78 cases(92.9%) and unsuitability in 6 cases (7.1%), in 84 cases of in organic substances. Compare to inflow stage, mean concentrations of heavy metal, were increased slightly in Zn, Cu, Fe except Mn than outflow stage. The result of the mean concentration in organic substance inflow and outflow in the apartment water tank using Pair-compared T-test, in 95% reliance index, were $0.179mg/{\ell}(0.151-0.307mg/{\ell})$ in Zinc, $0.136mg/{\ell}(0.113-0.230mg/{\ell})$ in Copper, $0.052mg/{\ell}(0.048-0.098mg/{\ell})$ in Fe, and there was a bit growing tendency but there was no differece in Mn. 6. The mean concentration of Copper which used Cu pipe as a water supply pipe in apartment were $0.216mg/{\ell}(0.161-0.338mg/{\ell})$ in case of the Zine pipe were $0.286mg/{\ell}(0.204-0.435mg/{\ell})$. It shows that the detection rate was more higher than the other material used in Cu or Zn as the water supply pipe. We supposed to Cu and Zn substance were gushing out water supply pipe.

  • PDF

Taste Compounds and Reapprearance of Functional Flavoring Substances from Low-Utilized Shellfishes (연안산 저활용 패류를 이용한 기능성 풍미소재의 정미성분 및 정미발현)

  • OH Kwang-Soo;HEU Min-Soo;PARK Hee-Yul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.6
    • /
    • pp.799-805
    • /
    • 1998
  • In present paper, we examined the flayer constituents and functionality of two stage enzyme hydrolysates (TSEH) of purplish clam and oyster, and also examined reappearance of oyster flavors through repreparation of individual flayer constituents. Total free amino acid contents in TSEH was $1943.0mg\%$ for purplish clam and was $5066.2 mg\%$ for oyster, respectively, Major free amino acids in purplish clam extracts were taurine, glutamic acid, glycine, alanine, Iysine and arginine, and in oyster extracts were taurine, asparagine, glutamic acid, valine, leucine, alanine, Iysine and arginine. As for nucleotides and related compounds, AMP was the principal component though small amounts in TSEH of purplish clam and oyster, and also contents of TMAO, total creatinine, and betaine were $41.2 mg\%,\;35,9 mg\%$ and $220.9 mg\%$ for that of purplish clam and $3.51 mg\%,\;33.4 mg\%$ and $380.9 mg\%$ that of oyster, respectively. The major inorganic ions in TSEH of both samples were Na, K, P, Cl and $PO_4$, and major non-volatile organic acid was succinic acid. The TSEH of purplish clam and oyster revealed very higher inhibition effect ($84.1\%,\;77.0\%$) in ACE inhibition than that ($0\~44.7\%$) of water and autolytic extract. A synthetic oyster extract prepared from pure chemicals on the basis of the analytical data on the TSEH, satisfactorily reproduced the taste of the natural extract except for a slight lack of mildness and odor. From the omission test the major taste compounds of oyster extract were free amino acid and inorganic ions. The quaternary ammonium bases, nucleotides and related compounds seemed to net an auxiliary role in taste of that.

  • PDF

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Quality Characteristics of Aerobic Packed Pork during Storage after Fermentation with Soy Sauce, Red Pepper and Soybean Paste Seasonings (간장, 고추장 및 된장 양념으로 발효시킨 함기포장 돈육의 저장기간 동안 품질 특성)

  • Jin, S.K.;Kim, I.S.;Hah, K.H.;Lyou, H.J.;Park, K.H.;Lee, J.R.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.679-690
    • /
    • 2005
  • This study was carried out to evaluate the quality characteristics of aerobic packed pork during storage after fermentation with soy sauce, red pepper and soybean paste seasonings. The ham of pork were cut to cube($7{\time}10{\time}2$cm) and Korea traditional seasonings such as soy sauce(T1), red pepper paste(T2), soybean paste(T3) were seasoned by the proportions of meat to seasonings(1:1), respectively. The seasoned sample were fermented by fill into plastic box at $1{\pm}1^{\circ}C$ for 10 days. And then, the fermented meat from each pack was aerobic packed and stored at $1{\pm}1^{\circ}C$ for up to 28 days. The pH of T1 were significantly(P<0.05) lower compared to T2 and T3 at 1 day of storage, but were significantly(P<0.05) higher at 14 and 28 days of storage. The water-holding capacity of T1were significantly(P<0.05) higher compared to T2 and T3 at 1 and 28 days of storage. The shear force of T3 were significantly(P<0.05) lower compared to T1 during storage. The surface meat L* values of T3 were significantly(P<0.05) higher than those of T1 and T2, but a* and b* values of T2 were significantly(P<0.05) higher. The volatile basic nitrogen(VBN) of T3 were significantly(P<0.05) lower compared to T2 at 1 and 14 days of storage, but T1 were significantly(P<0.05) lower at 28 days of storage. The thiobarbituric acid reactive substances(TBARS) of T3 were significantly(P<0.05) lower compared to T1 and T2. The total plate counts of T1 were significantly(P<0.05) lower compared to T2 and T3 at 1 day of storage, but T2 were significantly(P<0.05) lower at 14 and 28 days of storage. The Escherichia coli of T1 and T3 were significantly(P<0.05) lower compared to T2 at 1 day of storage. The Lactobacilli spp. of T2 were significantly(P<0.05) lower compared to T1 and T3.

Effect of Cryoprotectants on Quality Properties of Chicken Breast Surimi (냉동변성방지제의 종류가 닭가슴살 수리미의 품질 특성에 미치는 영향)

  • Jin, S.K.;Kim, I.S.;Kim, S.J.;Jeong, K.J.;Lee, J.R.;Choi, Y.J.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.6
    • /
    • pp.847-856
    • /
    • 2007
  • This study was conducted to determine the effect of cryoprotectants(sugar, sorbitol, polyphosphate) on quality properties of chicken breast surimi manufactured by pH adjustment(pH 11.0) during frozen storage. Final surimi was divided into experimental units to which the following treatments were randomly assigned: C(Alaska pollack surimi, two times washing, 4% sugar+5% sorbitol+0.3% polyphosphate additive); T1(chicken breast surimi, 0.3% polyphosphate additive); T2(chicken breast surimi, 5% sorbitol +0.3% polyphosphate additive); T3(chicken breast surimi, 4% sugar+5% sorbitol+0.3% polyphosphate additive). All amino acid contents of control were higher than those of all treatments, while T2 was higher in amino acid contents among the treatments. Shear force of all treatments were higher than that of control, but the breaking force, deformation and gel strength were lower. The TBARS(thiobarbituric acid reactive substances) and VBN(volatile basic nitrogen) values of all treatments were lower than those of control, The TBARS values of all treatments were increased with increased storage period. In sensory evaluation, the score of appearance, meat color and overall acceptability of control were higher than those of all treatments, but aroma, juiciness and tenderness were lower than those for all treatments.

Effect of Gas Mixture Ratio of Modified Atmosphere Packaging on Quality of Chicken Breast (CO2와 N2 혼합 비율에 따른 포장 닭고기 가슴육의 냉장 저장 중 품질 특성)

  • Chae, Hyun-Seok;Na, Jae-Cheon;Choi, Hee-Cheol;Kim, Min-Ji;Bang, Han-Tae;Kang, Hwan-Ku;Kim, Dong-Wook;Suh, Ok-Seok;Ham, Jun-Sang;Jang, Ae-Ra
    • Food Science of Animal Resources
    • /
    • v.31 no.1
    • /
    • pp.100-106
    • /
    • 2011
  • The physicochemical characteristics of chicken breast were determined to identify the optimal ratio of $CO_2$ and $N_2$ to maintain chicken breast quality during cold storage for 6 d. The mixing ratios of $CO_2$ and $N_2$ were 20:80, 40:60, 60:40, and 80:20, respectively. The pH of the chicken breast packed with 80% $CO_2$ and 20% $N_2$ was lower than that of the control on day 1 (p<0.05). The lightness ($L^*$) of the breast increased with increasing $CO_2$ during storage (p<0.05), whereas no difference was found for redness ($a^*$) and yellowness ($b^*$). A lower volatile basic nitrogen level was found for chicken breasts exposed to higher $CO_2$ levels. Furthermore, lipid oxidation of the chicken breast packed with $CO_2$ decreased with increasing $CO_2$ level, and 40% $CO_2$ significantly reduced 2-thiobarbituric acid reactive substances (TBARS) values on days 1 and 6. The total number of microbes was reduced in chicken breast exposed to more than 40% $CO_2$ during storage days 3 and 6 (p<0.05); however, Escherichia coli was not affected by $CO_2$ level. Coliforms of chicken breast were reduced in the 40% $CO_2$ level on storage day 3. Moreover, tray-packed chicken breast exposed to 40% $CO_2$ did not collapse. These results suggest that 40% $CO_2$ and 60% $N_2$ were the optimal conditions for packaging chicken breasts during cold storage.

Effect of Replacing Antibiotics by Herb Extracts and Digestive Enzymes Containing Vitamin E and Oriental Medicinal Plants Byproduct on Blood Serum Cholesterol and Meat Qualities in the Hog Loin Meat (항생제 대체를 위한 비타민 E 및 한방부산물을 포함한 허브추출물 및 효소제 복합처리가 거세돈의 혈액콜레스테롤 및 식육의 품질에 미치는 영향)

  • Kang, Suk-Nam;Kim, Jong-Duck;Kim, Il-Suk;Jin, Sang-Keun;Lee, Moo-Ha
    • Food Science of Animal Resources
    • /
    • v.27 no.1
    • /
    • pp.87-94
    • /
    • 2007
  • This study was carried out to know the effect of the oriental medicinal plants byproduct containing vitamin E and 0.1% antibiotics (T1) and the oriental medicinal plants byproduct containing vitamin E and the replacing antibiotics by 0.03% herb extracts (T2) and 0.1% aminolevulinic acid (T3) on production performance of finishing hog and its meat qualities. There were no significant differences in the daily weight gain, feed intake, and feed conversion rate values between all treatment groups. However, the T2 group tends to have a higher daily weight gain (g/day) than the other groups (p>0.05). The T2 group showed lower total-cholesterol and LDL-cholesterol contents (114.71 and 68.09 mg/dl, respectively) than the control in the blood serum (p<0.001), and all the treated groups of oriental medicinal plants byproduct and vitamin E increased HDL-cholesterol and decreased LDL-cholesterol contents in the blood serum. Content of vitamin E in muscles from the group T1, T2 and T3 (2.11, 2.21 and 2.18 mg $kg^{-1}$, respectively) showed higher levels than those of control. The presence of antibiotics (chlortetracycline) in hog loin meat were detected (0.08 ppm) in control sample. However, there was no antibiotic in other treated hog loin meats (T1, T2 and T3, respectively). The thiobarbituric acid reactive substances and volatile basic nitrogen values of the groups T2 (0.06 mg MA $kg^{-1}$ and 11.21 mg%, respectively) and T3 (0.05 mg MA $kg^{-1}$ and 8.23 mg%, respectively) were significantly (p<0.05) lower than that of control in loin meat. However, there was no significant difference between treated samples (T1, T2 and T3, respectively) and control in cooking loss and drip loss.

Comparison of the Quality of Gamma Ray- or Electron Beam-irradiated Minced Pork and Pork Patties (감마선 또는 전자선 조사된 분쇄돈육과 돈육패티의 저장 중 품질특성 비교)

  • Song, Beom-Seok;Park, Jin-Gyu;Kim, Wang-Geun;Kim, Jae-Hun;Choi, Jong-Il;Yoon, Yo-Han;Byun, Myung-Woo;Kim, Cheon-Jei;Lee, Ju-Woon
    • Food Science of Animal Resources
    • /
    • v.29 no.2
    • /
    • pp.194-202
    • /
    • 2009
  • This study was conducted to determine the effects of gamma and e-beam irradiation on the quality of minced pork and pork patties. Each sample was irradiated at 5 to 20kGy, and its quality characteristics were then evaluated during storage at 30. The results of the total bacterial populations in the minced-pork and pork patty samples showed that the antimicrobial effect of gamma irradiation was superior to that of e-beam irradiation. The 2-thiobarbituric acid reactive substances (TBARS) value of all the samples significantly increased (p<0.05) as the irradiation dose and storage period increased. In addition, the gamma-irradiated (GI) samples had higher (p<0.05) TBARS values than the e-beam-irradiated (EI) samples. The volatile basic nitrogen contents of the GI samples were lower (p<0.05) than those of the EI samples. The color values, such as the $L^*$(brightness), $a^*$(redness), and $b^*$(yellowness) of the minced pork and pork patties, were increased (p<0.05) by irradiation. The hardness and sensory properties, such as the color, chewiness, taste, and overall acceptability of the pork patties, were decreased when the irradiation dose increased, and the hardness and sensory scores of the GI samples were lower than those of the EI samples.

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.