• Title/Summary/Keyword: volatile substances

Search Result 316, Processing Time 0.025 seconds

Preparation of Natural Wall Paint by Using Sericite Clay (견운모를 이용한 벽마감용 천연페인트 제조)

  • Kim, Munui;Lalhmunsiama, Lalhmunsiama;Lee, Seung-Mok;Jin, Kang-Jung
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.501-505
    • /
    • 2017
  • Due to the rapid urbanization and increased population, there is an increase in airtight nature of buildings which causes serious indoor air pollution. Among several indoor air pollutants, volatile organic compounds (VOCs) emitted from paint are of major concern. Therefore, there is an urge for the development of environmental friendly paint products. In this wok, a natural wall paint (NWP) was prepared by utilizing a natural clay material "sericite" as a main component. A small chamber test was carried out to identify the toxic substances release from NWP and the results were compared with two eco-friendly commercial paints. The total VOCs were detected in trace level inside the test chamber and their concentrations were below the recommended indoor air quality standards. Toluene was not detected for NWP, whereas formaldehyde was observed in trace level. The toxicity index results were compared with two commercial paints and found that NWP exhibited less harmful gas emission. Based on certification rating of building materials, NWP can be classified as the first grade of building materials. Due to the above advantages, the use of sericite as a major component in NWP will be a useful technique to maintain the indoor air quality.

Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station (소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성)

  • Kim, Soo Jin;Ham, Seunghon;Jeon, Jeong Seok;Kim, Won
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.140-151
    • /
    • 2019
  • It is to assess the indoor air quality of the chemical hazardous materials exposed to the fire after firefighters returned to the fire scene. The research subject randomly selected four fire stations located in Seoul, Korea. Two fire stations were set up as control groups after the return of the firefighting activities at the actual fire scene, and two other fire stations were set up as control groups to measure the air quality of the room at normal levels regardless of the action. We conducted 24-hour monitoring for all fire accidents that occurred in Seoul Metropolitan using fire safety map computer system. Also, indoor air quality was measured immediately after homecoming if the experiment group was to be dispatched due to an accident of intermediate or larger scale. 11 hazardous substance items such as fine dust, formaldehyde, volatile organic compounds, PAH, VCM, acidity, asbestos, CO2, NO2, O3 were measured according to the process test method. Three of 11 types of harmful substances exceeded domestic and foreign standards, and one of them was found to be close to foreign standards. In particular, total volatile organic compounds, carbon dioxide and sulfuric acids were 2.5 times, 2.2 times and 1.1 times higher than the standard. Also, for formaldehyde and sulfuric acid, it was measured higher in the control group than in the case group. This findings could be used in policies to improve indoor air quality in the fire station of the Seoul Metropolitan Government.

Adsorption Characteristics of Heavy Metal and VOCs of Pyrolysis Char from Organic Waste Sludge (유기성 폐슬러지의 열분해 차르에 대한 중금속 및 VOCs 흡착특성)

  • Park, Sang-Sook;Kang, Hwa-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.130-137
    • /
    • 2005
  • This research programme include investigation of the adsorption behavior of heavy metals and VOCs by Pyrolysis char for using landfill cover material. The volatile potions in the sludge gasified during the pyrolysis period and gave birth to porosity throughout the matrix. The result of the ad/desorption experiment of nitrogen to find out the formation of some pore by the gasification of the volatile matter, we can certify that the pyrolysis char($14.56\;m^2/g$) has increased twice more than the organic wasted sludge($6.68\;m^2/g$) in specific surface area. The pyrolysis char has the adsorption characteristic of medium type of Type II and V in BDDT classification, and showed a little micro pore. In the adsorption experiment of ethylbenzene and toluene, as a result of applying the Freundlich adsorption isotherms, the pyrolysis char was higher in the adsorptivity of ethylbenzene and toluene than the granite and the organic wasted sludge. The results of the heavy metal adsorption test for the char indicated that it had some ability of adsorption. It is suggest that pyrolysis char has some advantages for utilizing as landfill covers because the pyrolysis char can adsorb/absorb hazardous substances from the landfill sites and inhibit the ground water and soil contamination.

Chemical Analysis on Biologically Active Substances among Habitats of Allium victorialis for a High Income Crop (산마늘의 고소득 작물화를 위한 기능성 물질 분석)

  • 박희준
    • Korean Journal of Plant Resources
    • /
    • v.11 no.1
    • /
    • pp.51-59
    • /
    • 1998
  • When the contents of the constituents such as total amino acids, free amino acids, volatile organosulfuric compounds and steroidal saponins among three origins in the aerial-and underground parts of Allium victorialis, it was suggested that the characteristic components regarding to quality evaluation could be differed according to the purpose of utilization. For the utilization of amino acids, underground parts of this plant was shown to be better than aerial part. In addition, Ulung island origin was found to contain the highest amino acids content among the three origins though the difference was small. The amino acids showing remarkably high contents were appeared to be arginine, glutamine and asparagine. In the volatile organosulfuric compounds, the origina of Mt. Odae and Mt. Chiri positioned in inland showed higher contents than Ulung island origin geographically positioned in the ocean. Inland origins were shown to contain higher organosulfurie component contents in aerial parts than in underground parts while those of Ulung island origin were higher in underground parts than aerial parts. Underground parts, regarding to saponin constituents, showed higher contents than aerial parts. Underground parts of Ulung island origin were shown to contain more saponins than those of other two origins and the sequence of the contents was in the order of Ulung island>Mt. Chiri>Mt Odac.

  • PDF

Exposure Characteristics of Construction Painters to Organic Solvents

  • Park, Hyunhee;Park, Hae Dong;Jang, Jae-Kil
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.63-71
    • /
    • 2016
  • Background: Construction painters have not been studied well in terms of their hazards exposure. The objective of this study was to evaluate the exposure levels of total volatile organic compounds (TVOCs) for painters in the construction industry. Methods: Activity-specific personal air samplings were carried out in three waterproofing activities [polyurethane (PU), asphalt, and cement mortar] and three painting activities (epoxy, oil based, and water based) by using organic-vapor-monitor passive-sampling devices. Gas chromatograph with flame ionization detector could be used for identifying and quantifying individual organic chemicals. The levels of TVOCs, by summing up 15 targeted substances, were expressed in exposure-index (EI) values. Results: As arithmetic means in the order of concentration levels, the EIs of TVOCs in waterproofing works were 10.77, 2.42, 1.78, 1.68, 0.47, 0.07, and none detected (ND) for indoor PU-primer task, outdoor PU-primer task, outdoor PU-resin task, indoor PU-resin task, asphalt-primer task, asphalt-adhesive task, and cement-mortar task, respectively. The highest EI for painting works was 5.61 for indoor epoxyprimer task, followed by indoor epoxy-resin task (2.03), outdoor oil-based-spray-paint task (1.65), outdoor water-based-paint task (0.66), and indoor oil-based-paint task (0.15). Assuming that the operations were carried out continuously for 8 hours without breaks and by using the arithmetic means of EIs for each of the 12 tasks in this study, 58.3% (7 out of 12) exceeded the exposure limit of 100% (EI > 1.0), while 8.3% (1 out of 12) was in 50e100% of exposure limit (0.5 > EI > 1.0), and 4 tasks out of 12 were located in less than 50% of the limit range (EI < 0.5). Conclusion: From this study, we recognized that construction painters are exposed to various solvents, including carcinogens and reproductive toxins, and the levels of TVOC concentration in many of the painting tasks exceeded the exposure limits. Construction workers need to be protected from chemical agents during their painting works by using personal protective devices and/or work practice measures. Additional studies should focus on the exposure assessment of other hazards for construction workers, in order to identify high-risk tasks and to improve hazardous work environments.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Transportation and City Gas: Design and Operation Guideline (고품질화 바이오가스 이용 기술지침 마련을 위한 연구(III): 도시가스 및 수송용 - 기술지침(안) 중심으로)

  • Moon, HeeSung;Kwon, Junhwa;Park, Hoyeon;Jeon, Taewan;Shin, Sunkyung;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.67-73
    • /
    • 2019
  • In this study, to optimize the production and utilization of biogas for organic waste resources, the precision monitoring of on-site facilities and the energy balance by facility were analyzed, and the solutions for field problems were investigated, and the design and operation guidelines for pretreatment facilities and generators were presented. Gas pre-treatment is required to solve frequent failures and efficiency degradation in operation of high quality refining facilities, and processing processes such as desulfurization, dehumidification, deoxidization, dust treatment, volatile organic compounds, etc. Since these processes are substances that are also eliminated from the high-quality process, quantitative guidelines are not presented in the gas pretreatment process, but are suggested to operate during the processing process as a qualitative guideline. In particular, dust, siloxane, and volatile organic compounds are the main cause of frequent failure of high-quality processes if they are not removed from the gas pretreatment process. Design of the biogas high-quality process. The operation guidelines provide quality standards [Methane content (including propane) of 95% or more] with 90% or more utilization of the total gas generation, two systems, and a margin of 10% or more. It also proposed installing gas equalization tank, installing thermal automatic control system for controlling equalization of auxiliary fuel, installing dehumidification device at the back of high quality for removing moisture generated in the process of gas compression, installing heat-resisting facilities to prevent freezing of facilities in winter and reducing efficiency, and installing membrane facilities in particular.

Effect of Different Packaging Atmosphere on Microbiological Shelf Life, Physicochemical Attributes, and Sensory Characteristics of Chilled Poultry Fillets

  • Nauman, Kashif;Jaspal, Muhammad Hayat;Asghar, Bilal;Manzoor, Adeel;Akhtar, Kumayl Hassan;Ali, Usman;Ali, Sher;Nasir, Jamal;Sohaib, Muhammad;Badar, Iftikhar Hussain
    • Food Science of Animal Resources
    • /
    • v.42 no.1
    • /
    • pp.153-174
    • /
    • 2022
  • This trial was conducted to evaluate the effect of overwrap, vacuum, and modified atmosphere packaging (MAP) on poultry breast fillets' microbiological, biochemical shelf life and sensory attributes. The fillets were divided into 4 groups, and each of the treatments was replicated 3 times with 60 breast fillets. The first group was a control group with overwrap packaging; the second group was vacuum packed (VP); the third and fourth groups were MAP-1: 0% O2, 40% CO2, 60% N2, and MAP-2: 20% O2, 40% CO2, 40% N2. The microbiological and biochemical analyses were performed for the total viable count, coliform count, Pseudomonas count, Salmonella count, total volatile basic nitrogen (TVB-N), pH, cooking loss, color, lipid oxidation, tenderness, and sensory analysis. The data were analysed through two-way ANOVA by Minitab (Minitab 17.3.1). Meat treated with understudy MAP compositions and vacuum packaging reduced total viable count, Pseudomonas count, and total coliform count than control (p<0.05). TVB-N remained below the recommended limit throughout storage except aerobic packaging (p<0.05). Cooking loss (%) was lowered and showed non-significant results (p>0.05) between vacuum packaging and both MAP concentrations. The meat stored in MAP-2 was characterised by higher (p<0.05) visual scores. Whilst MAP-1 showed higher (p<0.05) L* values and overall acceptability. Sample packaged under aerobic packaging showed significant (p<0.05) results for b* and thiobarbituric acid reactive substances (TBARS). Meat stored in aerobic packaging showed higher (p<0.05) shear force values. The outcome of this trial may help to promote the application of understudy MAP compositions and rapid detection of microbes by biochemical analysis under local conditions.

Synthesis and Properties of Photo-curable Biomass-based Urethane Acrylate Oligomers (광경화형 바이오매스계 우레탄 아크릴레이트 올리고머의 합성 및 물성 연구)

  • Se-Jin Kim;Lan-Ji Baek;Byungjin Koo;Jungin Choi;JungMi Cheon;Jae-Hwan Chun
    • Journal of Adhesion and Interface
    • /
    • v.24 no.1
    • /
    • pp.26-35
    • /
    • 2023
  • Generally, solvent-type coatings generate a large amount of volatile organic chemicals(VOC), which are carcinogenic substances, in the manufacturing process, and their use is regulated due to environmental problems. There is also the problem of resource depletion due to limited fossil fuels. Therefore, in this study, UV-curable urethane acrylate oligomers were synthesized with different contents of isosorbide, which is a biomass material, and proceeded to evaluate the physical properties of coatings. As the isosorbide contents increased, the viscosity, glass transition temperature, tensile strength, stain resistance, and pencil hardness increased, but elongation and flexibility decreased, and BOI-3 showed the best adhesion. The isosorbide content of the oligomer fixed at 20%, UV-curable urethane acrylate oligomer was synthesized according to the content ratio of polycaprolactone diol(PCL) and Ecoprol H1000(Ecoprol). As the PCL/Ecoprol content ratio increased, the glass transition temperature, elongation, and flexibility increased, but the tensile strength and pencil hardness decreased. It was confirmed that the adhesion and stain resistance increased by improving the surface bonding strength of PCL. All films of oligomers synthesized were transparent without discoloration.

Comparison of Instrument Characteristics on the Total Organic Carbon Analysis Method in Water Samples (수질분야 총유기탄소 분석방법에 따른 장비별 특성 비교)

  • Hye-Sung Kim;Eun-Tae Hwang;Chan-Geun Lee;Young-Cheol Cho
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.353-362
    • /
    • 2023
  • TOC, which can measure more than 90% of organic substances, can be measured quickly and easily,replacing BOD and COD, which were indicators of organic pollutants. According to water quality pollution control standards, when measuring TOC, if the inorganic carbon ratio in the sample is over 50%, the NPOC (Non-Purgeable Organic Carbon) method should be used. If volatile organic compounds (VOCs) are present at a certain concentration, the TC-IC (subtracting inorganic carbon from total carbon) method should be used. To validate the limitations of these analytical conditions, experiments were conducted by varying the ratio of TOC to IC in purified water and measuring the concentration of TOC in test solutions. The results showed no significant difference between the TC-IC method and the NPOC method. When measuring samples with added VOC standard solutions, it was observed that the carbon loss due to purging was not significant when using the NPOC method. Therefore, it is concluded that the choice of analytical method does not lead to significant differences when VOCs are present in the sample. To account for potential variations in results based on water quality pollution control standards and regulations regarding the approval and testing of environmental measurement devices, a comparison of field sample concentration values was made using two widely used types of TOC analyzers in Korea. The results showed variations of 0.02 to 0.83 mg/L between methods depending on the manufacturer, highlighting the need for caution when selecting an instrument.

Development of an Analytical Method for Chloropicrin Determination in Hulled Rice by GC-ECD and GC-MS (GC-ECD 및 GC-MS를 이용한 현미 중 chloropicrin의 잔류시험법 개발)

  • Do, Jung-Ah;Choi, Jeong-Heui;Park, Hyejin;Park, Yong-Chun;Yoon, Hae-Jung;Choi, Dongmi;Oh, Jae-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.222-226
    • /
    • 2013
  • A simple and sensitive analytical method was developed using gas chromatograph with electron capture detector (GC-ECD) and gas chromatograph-mass spectrometer (GC-MS) for determination and identification of chloropicrin. Because of small molecular weight and high volatile properties of chloropicrin, analytical method was developed utilizing headspace extraction and direct injection to the GC. The developed method was validated using hulled rice sample spiked with chloropicrin at different concentration levels, 0.1 and 0.5 mg/kg. Average recoveries of chloropicrin (using each concentration three replicates) ranged 77.7~79.3% with relative standard deviations less than 10% and calibration solutions concentration in the range $0.005{\sim}0.5{\mu}g/mL$, and limit of detection (LOD) and limit of quantification (LOQ) were 0.004 and 0.01 mg/kg, respectively. The result showed that developed analytical methods was successfully applied to detect a small amount of chloropicrin in hulled rice.