• Title/Summary/Keyword: void area ratio

Search Result 62, Processing Time 0.03 seconds

An Experimental Study on Water-Purification Properties of Porous Concrete Using Industrial By-Products (산업부산물을 사용한 포러스 콘크리트의 수질정화 특성에 관한 실험적 연구)

  • 조영수;김정환;권혁준;박승범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.717-722
    • /
    • 2002
  • The results of an experiment on the water purification of the porous concrete and its influence on the compressive strength are reported in this paper. Two different sizes of coarse aggregate of 5-10, and 10-20mm, and three absolute volume ratios of paste to aggregate of 30, 40 and 50 percent for a given size of aggregate were used. For the compressive strength, the concrete with the aggregate size of 5-10mm showed much higher strength than that with the aggregate size of 10-20mm. But, the compressive strength is higher when the ratio of paste to aggregate is smaller. In the water purification experiment, the amount of attached an organism on the porous concrete surface indirectly is examined by measuring the consumption of the Dissolved Oxygen (DO). The ability of the water purification is evaluated by the removal amount of the Total Phosphorus(T-P) and Total Nitrogen(T-N). The ability of the removal of the T-N and T-P in the test water is superior to a porous concrete with a smaller size of aggregate and a higher void content. These results are owing to a large specific surface area of the specimen. As a result, porous concrete using by-products has sufficient performance of water purification.

  • PDF

Porosity estimation using electrical resistance Cone Probe in offshore soils (전기저항 콘 프로브를 이용한 해안지반의 간극률 산정)

  • Lee, Jong-Sub;Kim, Joon-Han;Yoon, Hyung-Koo;Cho, Tae-Hyeon;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.127-133
    • /
    • 2008
  • The electrical resistivity methods have been commonly used for figuring out the ground layers. The purpose of this paper, differently from previous methods, is not only to figure out the layers but also to develope a equipment and a method to analyze ground porosity. Equipment has a shape of cone, which can be coupled with drilling rods. A field penetration test was performed to test application in Incheon Chungla area. Through the field test soil resistances were measured. To calculate soil porosity along the depth, Archie's law is applied. The results show that a new equipment and porosity analysis method using Archie's law can distinguish soil layers and precisely measure soil porosity.

  • PDF

The Application of Piezocone Penetration Test at Inchon International Airport (인천국제공항지역의 피에조콘조사와 결과의 적용)

  • 김종국;성기광;김학중;김영웅
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.2
    • /
    • pp.115-123
    • /
    • 2000
  • Piezocone Penetration Test has been performed in the soft ground over the site preparation area at Inchon International Airport(IIA). With the pore pressure dissipation test results, the changes in the permeability and the coefficient of consolidation in clayey soil were checked and the differences of the undrained shear stength verified the soft ground improvement effect from vane test and piezocone test both before and after the improvement. From the results, thin sand seam was found and this caused a big difference in the coefficient of permeability and consolidation. The coefficient of consolidation was high in the upper marine deposit and relatively low in lower marine deposit. It was found that the reduction of void ratio by preloading resulted in the reduction of coefficient of consolidation after the ground improvement. In addition, there were some variations of undrained shear strength when the number of 15 or 18 was used as the coefficient of piezocone(Nkt). However, when the average value of undrained shear strength calculated using Nkt=10 was applied, the result indicated the similar average value with the result of vane test and the increasing rate of strength( Δsu/Δ$\sigma$≒0.38) also showed the similar distribution.

  • PDF

Assessment of Consolidation Properties Using Modified Oedometer for Radial Drainage Condition (개량형 수평배수 압밀시험 장치에 의한 압밀특성 평가)

  • Jeon, Jesung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.143-150
    • /
    • 2009
  • Material functions about effective stress, permeability, coefficient of consolidation and coefficient of volume change has important role to predict consolidation velocity and settlement of soft ground. Modified oedometer for radial drainage is adapted to find out material functions on laboratory tests. Undisturbed sample for laboratory tests were taken from construction sites of industrial complexes on southern coastal area which consists of upper dredged fill and lower original clay layer. For different drainage condition in consolidation process void ratio, effective stress, permeability, coefficient of consolidation and coefficient of volume change has been assessed with results of existing standard oedometer tests. It is worthwhile to note that consolidation material functions could be expressed as regression equation by Stark (2005), heterogeneity for permeability could be assessed from these relationships.

  • PDF

GROUND TREATMENT CASE HISTORY OFR SOFT CLAY LAYER AND EVALUATION OF ITS IMPROVEMENT (연약지반처리와 개량효과 평가사례)

  • Lee, Yeong-Nam;Lee, Hyeong-Ju;Sim, Dong-Hyeon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.10a
    • /
    • pp.113-120
    • /
    • 1992
  • The construction of container terminal at Brani, Singapore required the improvement of soft clay layer having the thickness of about 6.5m, average moisture content of 79.4%, liquid limit of 90.4%, plastic limit of 21.8%, field vane strength of 10 to 25 KPa, pre-consolidation pressure of 225 to 60 KPa and compression index of 0.4 to 1.0. For the improvement of this layer, Colbon drains of 1.3m spacing in triangular pattern were installed to the bottom of the layer and surcharge of more than 11.25m high sand fill was later applied to the treated area. The settlement and lateral displacement of the ground were measured and the speed of surcharge filling was controlled, based on these readings. The removal of surcharge was determinied using the estimated time for the 90% degree of consolidation under the design pressure of 180KPa. The field and laboratory test results show that the soft clay layer has been improved substantially in its strength and consolidation characteristics: increase in strength of about 50KPa and pre-consolidation pressure and decrease in void ratio and compression index.

  • PDF

Physical Properties of Soils in Relation to Forest Composition in Moist Temperate Valley Slopes of the Central Western Himalaya

  • Sharma, C.M.;Gairola, Sumeet;Ghildiyal, S.K.;Suyal, Sarvesh
    • Journal of Forest and Environmental Science
    • /
    • v.26 no.2
    • /
    • pp.117-129
    • /
    • 2010
  • The present study was undertaken in moist temperate forest of Mandal-Chopta area in the Garhwal region of Uttarakhand, India. The aim of the present study was to assess the physical properties of soils in relation to the forest structure and composition. Twelve forest types according to the altitude, slope aspect and species compositions were selected for the study. Physical properties of soil i.e., soil colour, soil texture (per cent of sand, silt and clay), moisture content, water holding capacity, porosity, bulk density (gm/$cm^3$) and void ratio were analyzed for three different depths viz., (i) 'upper' (0-10 cm), (ii) 'middle' (11-30 cm) and (iii) 'lower' (31-60 cm) in all the selected forest types. Phytosociological and diversity parameters viz. total basal cover ($Gha^{-1}$), stem density ($Nha^{-1}$), tree species richness, Simpson concentration of dominance and Shannon-Wiener diversity index were also calculated for each forest type. This study also provides the comparisons between the results of physical analysis of the present study with numerous other previous studies in the temperate Himalayan region of the Uttarakhand.

Development of the Linear Regression Analysis Model to Estimate the Shear Strength of Soils (흙의 전단강도 산정을 위한 선형회귀분석모델 개발)

  • Lee, Moon-Se;Ryu, Je-Cheon;Kim, Kyeong-Su
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.177-189
    • /
    • 2009
  • The shear strength has been managed as an important factor in soil mechanics. The shear strength estimation model was developed to evaluate the shear strength using only a few soil properties by the linear regression analysis model which is one of the statistical methods. The shear strength is divided into two part; one is the internal friction angle (${\phi}$) and the other is the cohesion (c). Therefore, some valid soil factors among the results of soil tests are selected through the correlation analysis using SPSS and then the model are formulated by the linear regression analysis based on the relationship between factors. Also, the developed model is compared with the result of direct shear test to prove the rationality of model. As the results of analysis about relationship between soil properties and shear strength, the internal friction angle is highly influenced by the void ratio and the dry unit weight and the cohesion is mainly influenced by the void ratio, the dry unit weight and the plastic index. Meanwhile, the shear strength estimated by the developed model is similar with that of the direct shear test. Therefore, the developed model may be used to estimate the shear strength of soils in the same condition of study area.

Physical Properties of Sandy Sediment in the Southeastern Coast of Korea (한국 남동해역 사질퇴적물의 물리적 성질)

  • KIM Gil-Young;KIM Dae-Choul;PARK Soo-Chul;YOO Dong-Geun;CHOI Jin-Hyuk;KIM Jeong-Chang
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.5
    • /
    • pp.663-676
    • /
    • 1996
  • Physical properties and textural parameters of thirty-five piston tore samples recovered from the southeastern coast of Korea (Korea Strait), were investigated using the autopycnometer. The physical properties (porosity, water content, wet bulk density, dry bulk density, gram density, and void ratio) were measured at rather uniform intervals along each core. Sediment texture (grain size, sand, silt, and clay contents) was also measured at the same subbottom depth. The measured and calculated results are; mean grain size $0.57\~8.09\phi(average:3.67\phi)$, porosity $26\~81\%\;(average:\;55\%)$, water content $16.7\~61.4\%(average:\;31.6\%)$, wet bulk density $1.37\~2.18g/cm^3\;(average:\;1.85g/cm^3)$, dry bulk density $2.55\~3.11g/cm^3\;(average:\;2.35g/cm^3)$, grain density $2.40\~3.10g/cm^3\;(average:\;2.85g/cm^3)$, and void ratio $0.56\~2.54$ (average: 0.94). The sediment texture generally coincides well with the bathymetry indicating the influence of Pleistocene-Holocene sea level changes. Also the contours of physical properties are closely related to the sediment texture. Fluctuation of physical properties are similar to the textural variation. It seems that sediment texture is a significant factor in determining physical property in this study area.

  • PDF

Initial Shear Strength of Hollow Sectional Columns Subjected to Lateral Force (횡하중을 받는 RC 중공단면 기둥의 초기전단강도)

  • Sun, Chang-Ho;Kim, Ick-Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.1-14
    • /
    • 2009
  • Ductility-based seismic design is strongly required for the rational and cost-effective design of RC piers, and a reliable evaluation of shear strength is indispensable for its success. Unlike the flexural behavior of RC columns, shear behavior is highly complex, due to its many effects such as size, aspect ratio, axial force, ductility and so on. To address this, many design and empirical equations have been proposed considering these effects. However, these equations show significant differences in their evaluation of the initial shear strength, and the reduction in strength with the increase of ductility. In this study, the characteristics of initial shear strength of hollow sectional columns were investigated using experiments with the parameters of aspect ratios, void ratios, web area ratios and load patterns. The test results were analyzed through a comparison with the values predicted by empirical equations. On the basis of the mechanical characteristics and test results, a new empirical equation was proposed, and its validity was assessed.

Frost-Heaving Characteristics of Soil Mixed with Discarded Tire Powder (폐타이어 파우더 혼합토의 동상 특성)

  • Kim, Hak-Sam;Seo, Sang-Youl;Nakamura, Dai;Fukuda, Masami;Yamashita, Satoshi;Suzuki, Teruyuki
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.4
    • /
    • pp.15-26
    • /
    • 2010
  • To determine the frost heave suppressing mechanism of soil mixed with tire powder, we conducted three kinds of laboratory experiments: measurement of unfrozen water, evaluation of thermal conductivity, and a frost heave. In this research, we focused on changes in the coefficient of permeability of the mixed soil, and first found that of the unsaturated soil. Next, in the case of the presence of ice, we took the ice-impeding factor into consideration to derive the coefficient of permeability of the frozen fringe from the area ratio of the soil and tire powder in mixed soil. The results show a positive correlation between the water intake rate and the coefficient of permeability. Moreover, we found that the frost heave decreased thanks to a reduction in the permeability and a fall in the unfrozen water content of the soil mixed with tire powder. We also calculated the weight of the water content of the soil and tire powder void quantitatively using the result of the volumetric ratio of mixed soil.