• Title/Summary/Keyword: visualization materials

Search Result 278, Processing Time 0.03 seconds

Effectiveness of the Microlux/DLTM Chemiluminescence Device in Screening of Potentially Malignant and Malignant Oral Lesions

  • Ibrahim, Suzan Seif;Al-Attas, Safia Ali;Darwish, Zeinab Elsayed;Amer, Hala Abbas;Hassan, Mona Hassan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6081-6086
    • /
    • 2014
  • Background: To evaluate the effectiveness of Microlux/DL with and without toluidine blue in screening of potentially malignant and malignant oral lesions. Materials and Methods: In this diagnostic clinical trial clinical examination was carried out by two teams: 1) two oral medicine consultants, and 2) two general dentists. Participants were randomly and blindly allocated for each examining team. A total of 599 tobacco users were assessed through conventional oral examination (COE); the examination was then repeated using Microlux/DL device and toluidine blue. Biopsy of suspicious lesions was performed. Also clinicians opinions regarding the two tools were obtained. Results: The sensitivity and, specificity and positive predictive value (PVP) of Microlux/DL for visualization of suspicious premalignant lesions considering COE as a gold standard (i.e screening device) were 94.3%, 99.6% and 96.2% respectively, while they were 100%, 32.4% and 17.9% when considering biopsy as a gold standard. Moreover, Microlux/DL enhanced detection of the lesion and uncovered new lesions compared to COE, whereas it did not alter the provisional clinical diagnosis, or alter the biopsy site. On the other hand, adding toluidine blue dye did not improve the effectiveness of the Microlux/DL system. Conclusions: The Microlux/DL seems to be a promising adjunctive screening device.

Investigation of influence of homogenization models on stability and dynamic of FGM plates on elastic foundations

  • Mehala, Tewfik;Belabed, Zakaria;Tounsi, Abdelouahed;Beg, O. Anwar
    • Geomechanics and Engineering
    • /
    • v.16 no.3
    • /
    • pp.257-271
    • /
    • 2018
  • In this paper, the effect of the homogenization models on buckling and free vibration is presented for simply supported functionally graded plates (FGM) resting on elastic foundation. The majority of investigations developed in the last decade, explored the Voigt homogenization model to predict the effective proprieties of functionally graded materials at the macroscopic-scale for FGM mechanical behavior. For this reason, various models have been used to derive the effective proprieties of FGMs and simulate thereby their effects on the buckling and free vibration of FGM plates based on comparative studies that may differ in terms of several parameters. The refined plate theory, as used in this paper, is based on dividing the transverse displacement into both bending and shear components. This leads to a reduction in the number of unknowns and governing equations. Furthermore the present formulation utilizes a sinusoidal variation of displacement field across the thickness, and satisfies the stress-free boundary conditions on the upper and lower surfaces of the plate without requiring any shear correction factor. Equations of motion are derived from Hamilton's principle. Analytical solutions for the buckling and free vibration analysis are obtained for simply supported plates. The obtained results are compared with those predicted by other plate theories. This study shows the sensitivity of the obtained results to different homogenization models and that the results generated may vary considerably from one theory to another. Comprehensive visualization of results is provided. The analysis is relevant to aerospace, nuclear, civil and other structures.

Making an Emotional Design Book with 5 Senses and Inspiration -Focused on the Art Book 5+1(Five Plus One)- (오감과 영감을 활용한 감성북 편집디자인 연구)

  • Hong, Dong-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.144-151
    • /
    • 2010
  • Five Plus One' is a result of visual expressions on five senses such as the sense of sight, hearing, smell, taste, and touch. Although I searched for the data on five senses, there were only information which was quoted in various languages and scientific bases, and also most of the books written were far from artistic expressions including visual pleasure and emotional expressions. In addition, most materials were mainly textbooks for children's intellectual development, academic papers, and medical publications. Therefore, I made this book that makes us to communicate about five senses and an inspiration even though we have a problem to read writings in both Korean and English. I arranged visual elements using illustrations and typography in various ways based on the scientific evidence.

Numerical Simulation of Directivity for Probe and Surface Defect (탐촉자와 표면 결함에 대한 지향성의 수치 실험에 관한 연구)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.1
    • /
    • pp.291-298
    • /
    • 1995
  • An ultrasonic testing uses the directivity of the ultrasonic wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. This paper studied the directivity of shear waves emitted from angle probes and scattered from surface defects by using visualization method. These experimental results were compared with the theory which was based on the continuous wave. The applicability of continuous wave theory was discussed in terms of the parameter $d/{\lambda}$; where d is transducer or defect size and ${\lambda}$ is the wavelength. In the case of angle probes, the experimental results show good agreement with theoretical directivity on the principal lobe. When defect size was smaller than the wavelengths, clear directivity in the reflected wave was observed. In the case of the same ratio of defect size to wavelength, the directivity of reflected waves from the defect show almost the same directivity in spite of frequency differences. When the $d/{\lambda}$ is greater than 1.5, measured directivities almost agreed with the theoretical one.

  • PDF

Visualization of Virtual Slave Manipulator Using the Master Input Device (주 입력장치를 이용한 가상 슬레이브 매니퓰레이터의 시각화)

  • 김성현;송태길;이종열;윤지섭
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.388-394
    • /
    • 2003
  • To handle the high level radioactive materials such a spent fuel, the master-slave manipulators (MSM) are widely used as a remote handling device in nuclear facilities such as the hot cell with sealed and shielded space. In this paper, the Digital Mockup which simulates the remote operation of the Advanced Conditioning Process(ACP) is developed. Also, the workspace and the motion of the slave manipulator, as well as, the remote operation task should be analyzed. The process equipment of ACP and Maintenance/Handling Device are drawn in 3D CAD models using IGRIP. Modeling device of manipulator is assigned with various mobile attributes such as a relative position, kinematics constraints, and a range of mobility, The 3D graphic simulator using the external input device of space ball displays the movement of manipulator. To connect the external input device to the graphic simulator, the interface program of external input device with 6 DOF is deigned using the Low Level Tele-operation Interface(LLTI). The experimental result shows that the developed simulation system gives much-improved human interface characteristics and shows satisfactory response characteristics in terms of synchronization speed. This should be useful for the development of work's education system in the virtual environment.

  • PDF

The Effects of 3-D Computer Animation on Educational Visual Presentation -Focused on Color Theory Study- (3D 컴퓨터 애니메이션을 이용한 시청각 교재가 어린이의 학습에 미치는 효과에 대한 연구 -색채이론학습을 중심으로-)

  • 최유미
    • Archives of design research
    • /
    • v.15 no.1
    • /
    • pp.49-58
    • /
    • 2002
  • Advances in computer technology have made it possible for educators to design and develop their own multimedia instructional materials using visuals such as animation. Although, it generally believed that the Mew attribute of computer animation facilitates student's foaming, there is still relatively little research regarding the way in which student benefit from multimedia instruction using 3-D animation. The purpose of this research was to examine and determine whether the use of 3-D computer generated images is an effective teaching device for hoping children to understand color theory, and enhancing the tractional methods. In this study, a 3-D computer generated presentation was creative and it demonstrated the mixing of primary color to obtain secondary color. Three research hypotheses were developed in this research. The first hypothesis stated that 3-D computer generated presentation will be an effective device for teaching color theory. The second was that the presentation will be eye-catching and it will hold the children's attention. The third was presentation would enhance the children's memory of color. Results of this study show that visualization technology and the use of 3-D graphics ends can be employed in the field of art education to increases a chi1d's understanding of color theory. Also, it was proved that teaching children through 3-D graphic is an highly effective teaching tool. Thus this research is a oontribution to both children's au education and the relatively new field of computer animation.

  • PDF

Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography (영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF

Analysis on Anisotropy of Void Distribution and Stiffness of Lightweight Aggregate using CT Images (CT 이미지를 활용한 경량 골재의 방향에 따른 공극 분포 및 강성도의 이방성 분석)

  • Chung, Sang-Yeop;Han, Tong-Seok;Yun, Tae Sup;Youm, Kwang Soo;Jeon, Hyun-Gyu;Kang, Dong Hun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.3
    • /
    • pp.227-235
    • /
    • 2012
  • The void distribution in concrete materials strongly affects its material properties. Therefore, the identification of spatial distribution of void is important to understand and estimate material behavior. To examine and quantify the void distribution inside lightweight aggregates, CT(computed tomography) image is used. 3D lightweight aggregate images are generated by stacking of cross-sectional images from CT. Spatial distribution of void of aggregate along the direction is visualized on the sphere using probability distribution function. Stiffness of lightweight aggregate for the directions is also examined. It is confirmed that direction-based probability distribution and stiffness from CT images are effective in characterizing void distributions of aggregates.

The effect of different radiographic parameters on the height, width and visibility of cross-sectional image of mandible in spiral tomography (나선형 단층방사선사진촬영에서 촬영조건이 악골 단면상의 높이, 폭 및 인지도에 미치는 영향)

  • Lee Tae-Wan;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.43-49
    • /
    • 2003
  • Purpose : To evaluate the differences in bone height, bone width, and visibility of posterior spiral tomographic images according to various exposure directions, image layer thickness, and inclination of the mandibular inferior border. Materials and Methods: Six partially and completely edentulous dry mandibles were radiographed using Scanora spiral tomography. Spiral tomography was performed at different exposure directions (dentotangential and maxillotangential projection), image layer thicknesses (2 mm, 4 mm and 8 mm), and at various inclinations to the mandibular border (+ 100, 00 and -10°). The bone height and width was measured using selected tomographic images. The visibility of mandibular canal, crestal bone, and buccal and lingual surfaces were graded as 0, 1, or 2. Results : The bone width at the maxillo-tangential projection was wider than at the dento-tangential projection (p < 0.05). The visibility of buccal and lingual surface at the maxillo-tangential projection was higher than at the dento-tangential projection (p<0.05). Thinner image layer thicknesses resulted in greater visibility of buccal and lingual surfaces (p < 0.05). Bone height was greatest in the -10° group, and at the same time the bone width of the same group was the narrowest (p < 0.05). The visibility of alveolar crest and buccal surface of the + 10° group was the highest, while the visibility of the mandibular canal was greatest in the 00 group. Conclusion: When spiral tomography is performed at the mandibular posterior portion for visualization prior to implant surgery, it is important that the inferior border of mandible be positioned as parallel as possible to the floor. A greater improvement of visibility can be achieved by maintaining a thin image layer thickness when performing spiral tomography.

  • PDF

Real-time Vessel Navigation Using Indocyanine Green Fluorescence during Robotic or Laparoscopic Gastrectomy for Gastric Cancer

  • Kim, Mina;Son, Sang-Yong;Cui, Long-Hai;Shin, Ho-Jung;Hur, Hoon;Han, Sang-Uk
    • Journal of Gastric Cancer
    • /
    • v.17 no.2
    • /
    • pp.145-153
    • /
    • 2017
  • Purpose: Identification of the infrapyloric artery (IPA) type is a key component of pylorus-preserving gastrectomy. As the indocyanine green (ICG) fluorescence technique is known to help visualize blood vessels and flow during reconstruction, we speculated that this emerging technique would be helpful in identifying the IPA type. Materials and Methods: From August 2015 to February 2016, 20 patients who underwent robotic or laparoscopic gastrectomy were prospectively enrolled. After intravenous injection of approximately 3 mL of ICG (2.5 mg/mL), a near-infrared fluorescence apparatus was applied. The identified shape of the IPA was confirmed by examining the actual anatomy following infrapyloric dissection. Results: The mean interval time between ICG injection and visualization of the artery was 22.2 seconds (range, 14-30 seconds), and the mean duration of the arterial phase was 16.1 seconds (range, 9-30 seconds). The overall positive predictive value (PPV) of ICG fluorescence in identifying the IPA type was 80% (16/20). The IPA type was incorrectly predicted in four patients, all of whom were obese with a body mass index (BMI) of more than $25kg/m^2$. Conclusions: Our preliminary results indicate that intraoperative vascular imaging using the ICG fluorescence technique may be helpful for robotic or laparoscopic pylorus-preserving gastrectomy.