• 제목/요약/키워드: visual fixation

검색결과 189건 처리시간 0.025초

A modified method of augmented distal clavicle fracture osteosynthesis with a Fibertape coracoclavicular cerclage

  • Wu, ChengHan;Teo, Timothy Wei Wen;Wee, Andy Teck Huat;Toon, Dong Hao
    • Clinics in Shoulder and Elbow
    • /
    • 제25권3호
    • /
    • pp.230-235
    • /
    • 2022
  • Background: Unstable distal clavicles experience high non-union rates, prompting surgeons to recommend surgery for more predictable outcomes. There is a lack of consensus on the optimal method of surgical fixation, with an array of techniques described in the literature. We describe an alternative method of fixation involving the use of a distal clavicular anatomical locking plate with Fibertape cerclage augmentation in our series of patients. Methods: Nine patients (8 males and 1 female), with a mean age of 36 years, who sustained unstable fracture of the distal clavicle in our institution were treated with our described technique. Postoperative range of motion, functional and pain scores, and time to radiographic union were measured over a mean follow-up period of 10 months. Incidences of postoperative complications were also recorded. Results: At the last patient consult, the mean visual analog scale score was 0.88±0.35, with a mean Disabilities of the Arm, Shoulder, and Hand (DASH) score of 1.46±0.87 and American Shoulder and Elbow Surgeons (ASES) score of 94.1±3.57. The mean range of motion achieved was forward flexion at 173°±10.6°, abduction at 173°±10.6°, and external rotation at 74.4°±10.5°. All patients achieved internal rotation at a vertebral height of at least L2 with radiographical union at a mean of 10 weeks. No removal of implants was required. Conclusions: Our described technique of augmented fixation of the distal clavicle is effective, produces good clinical outcomes, and has minimal complications.

Anatomic coracoclavicular ligament reconstruction with triple flip-buttons leads to good functional outcomes and low reduction loss: a case series

  • Raul Aguila;Gonzalo Gana;J Tomas Munoz;Diego Garcia de la Pastora;Andres Oyarzun;Gabriel Mansilla;Sebastian Coda;J Tomas Rojas
    • Clinics in Shoulder and Elbow
    • /
    • 제26권2호
    • /
    • pp.140-147
    • /
    • 2023
  • Background: The management of acromioclavicular (AC) joint dislocation remains controversial. Recently, anatomic coracoclavicular (CC) fixation with a double clavicular tunnel and three flip-buttons has shown promising results. This study aimed to evaluate functional and radiological outcomes in patients with high-grade AC joint dislocation treated with anatomic CC fixation using double clavicular tunnels and three flip-buttons. Methods: A retrospective, unicentric study was performed. The study included patients with high-grade AC joint dislocation who underwent surgery with anatomic CC fixation using double clavicular tunnels and three flip-buttons. Demographic data were obtained from medical records. A functional evaluation using subjective shoulder value (SSV), visual analog scale (VAS), and disabilities of the arm, shoulder, and hand (DASH) questionnaires was performed, and an evaluation of preoperative and postoperative comparative Zanca view images was performed. Factors associated with functional outcomes and radiological AC reduction were analyzed. Results: A total of 83 patients completed follow-up and were included in the analysis. The mean SSV, VAS, and DASH scores were 92.8, 0.8, and 6.4, respectively. Patients who had complications experienced significantly worse functional outcomes (DASH: P=0.037). Suboptimal final AC reduction was observed in nine patients (11.1%), and significantly more frequently in patients older than 40 years (P=0.031) and in surgeries performed more than 7 days after injury (P=0.034). There were two reoperations (2.4%). Conclusions: Anatomic CC fixation with a double clavicular tunnel and three flip-buttons leads to good functional outcomes, low complication rates, and high rates of optimal AC reduction.

평형감각 측정기술의 개발 (Development for a method of measurement in equilibrium sense)

  • 이문영;정영자;김규겸;이성호;박병림
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1999년도 춘계학술발표논문집 논문집
    • /
    • pp.3-6
    • /
    • 1999
  • The study was performed to evaluate the sense of equilibrium by means of rotary chair system in middle school girls with dance learning. Control of equilibrium, which is the most important function in dancing, is maintained by vestibular, visual, and proprioceptive inputs. Experimental groups were divided into trained group with dance (experimental group, 13~14 ys, n=15) and untrained group (control group, 13~14 ys, n=15). experimental group was trained by programmed dancing for 12 weeks, 45 min/day and 5 day/week. Gain of eye movement was measured for vestibulocular reflex (VOR), visual vestibular stimulation (VVOR), optokinetic stimulation(OKN), and visual fixation (VFX). The gain of eye movement at higher than 0.08 hz was significant decrease in experimental group, and VVOR showed the similar fashion to VOR. The gain in OKN and VFX was not significant difference between experimental and control groups. These results suggest that programmed training of dancing improves control of balance by adaptation of the vestibular function, and rotary chair system would be useful to evaluate the sense of equilibrium ability.

  • PDF

초등 교사들의 과학교과서 그래프 이해 과정에 대한 안구 운동 분석 (Eye Movement Analysis on Elementary Teachers' Understanding Process of Science Textbook Graphs)

  • 신원섭;신동훈
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제31권3호
    • /
    • pp.386-397
    • /
    • 2012
  • The purpose of this study was to find a way to improve the science textbook graph through analyzing teachers' interpretation process with eye movement tracking when they try to read the science textbook graph. Participants in this project were 10 elementary school teachers while bar graphs, line graphs, pie charts in 2007 revision science textbooks were used as materials. SMI (SensoMotoric Instruments)' iView X TM RED 120 Hz was used in order to collect eye movement data. Although subjects paid attention to the title of the graph at first, the consequence of the eye fixation was changed by the composition of the graph in case of the rest of areas. In particular, the flow of visual attention and fixation time were affected by the form and configuration of the graph. The diversity of graph construction caused confusion in interpreting graphs; the manner of presenting title, the difference of background colors, size of characters, the name of X-axis and Y-axis. Out results showed that the conformation of graphs as well as the presentation of each factor should be composed in accordance with the educational purpose for helping users to easier understanding.

아이트래킹을 활용한 인기 애니메이션 캐릭터의 시각적 주의에 관한 연구 (A Study on the Visual Attention of Popular Animation Characters Utilizing Eye Tracking)

  • 황미경;권만우;박민희;은석함
    • 한국콘텐츠학회논문지
    • /
    • 제19권6호
    • /
    • pp.214-221
    • /
    • 2019
  • 사람의 눈을 통해 획득된 시각정보는 시각적 자극을 어떻게 보는지에 대한 많은 정보를 포함하고 있는데, 아이트래킹기술을 활용하면 소비자의 시각정보를 정량적 데이터로 획득하여 분석가능하다. 이러한 측정은 소비자가 무의식적으로 느끼게 되는 감성 측정이 가능하며, 시선추적을 통한 캐릭터의 탐색반응을 계량적으로 수치화하여 직접 수집할 수 있다. 본 연구에서는 캐릭터의 관심영역(AOI)을 추적하여, 시선고정 도출 측정값 중 시선고정평균시간, 횟수, 시선방문평균시간, 횟수, 마지막으로 처음 시선고정이 일어난 평균시간을 분석하였다. 분석결과, 전체적으로 시선고정과 시선방문이 주로 이루어진 지점은 캐릭터의 몸매보다는 얼굴에서 많은 인지적 처리과정이 일어났으며 시각적 주의가 높게 나타났다. 또한 매력요소의 시각적 주의를 통해 매력요소가 캐릭터에 대한 선호도를 결정하는 중요한 요인으로 제시되고 있음을 검증할 수 있었다. 향후 본 연구결과를 토대로 더 많은 캐릭터의 추가 연구가 수행되어 정량적 해석 방법이 제시된다면 캐릭터 개발의 기초자료로 그리고 캐릭터디자인 결정시 고려해야 할 요소로 활용될 수 있을 것이다.

발목 골절 및 탈구 혹은 경골 천정 골절 환자들의 수술에 있어 경종골핀을 이용한 발목 외고정 장치를 적용했을 때의 임상적 효용성 (Efficacy of Temporal Fixation Using Threaded Trans-Calcaneal Pin in Patients with Ankle Fracture-Dislocation or Tibia Pilon Fractures)

  • 박대현;곽희철;김정한;이창락;권용욱;추혜정;박철순
    • 대한족부족관절학회지
    • /
    • 제24권2호
    • /
    • pp.81-86
    • /
    • 2020
  • Purpose: Ankle fractures with dislocations and pilon fractures at the distal tibia are usually associated with soft tissue damage caused by high-energy damage. Recently, a two-stage operation to perform internal fixation after the application of external fixation devices for stabilizing soft tissues has been accepted as the treatment of choice. This paper reports the clinical result of these injuries treated with threaded trans-calcaneal pin external fixation devices. Materials and Methods: Thirty-three patients diagnosed with ankle fractures with dislocations or tibial pilon fractures without open wounds. They underwent surgical treatment with threaded trans-calcaneal pin external fixation from January 2008 to February were enrolled in this study. This study evaluated the visual analogue scale (VAS), foot function index (FFI), and Olerud & Molander score as well as whether complications occurred. Results: The average VAS showed a meaningful decrease (p<0.001) from 7.4 before surgery to 2.6 after application of the external fixation device, and 1.4 at 12 months after surgery. The FFI also decreased significantly from 84.3 preoperatively to 20.3 at 12 months postoperatively (p<0.001). The Olerud & Molander score averaged 71.4 points, showing good clinical results. Complete bone union was observed in all patients. One patient each underwent debridement due to wound necrosis and infection in the pin insertion site. At the final follow-up, seven patients had posttraumatic ankle joint arthritis, according to a radiological examination. Conclusion: Manual reduction and external fixation using a threaded trans-calcaneal pin is a suitable surgical technique that is easy to perform and shows good clinical outcomes in stabilizing soft tissue damage in fractures and dislocations of ankle fracture or tibia pilon fractures in foot and ankle injury.

강선 고정술을 이용한 관골골절의 치료 (Intraoral Approach and K-Wire Fixation of Zygomatic Tripod Fractures)

  • 최시호
    • Journal of Yeungnam Medical Science
    • /
    • 제5권1호
    • /
    • pp.85-92
    • /
    • 1988
  • 저자는 관골 골절 환자중 일부 안서 골절로 안와내용물의 탈출이 동반된 관골 골절, 경구개 골절이 동반된 관골 골절, 소아의 관골 골절을 제외한 대다수의 삼격면 관골 골절 환자 37례를 구강내 절개와 K-강선고정술을 이용하여 수술 하였던 바, 첫째, 안면부 반흔을 남기지 않고, 둘째, 간단하며, 셋째, 직시하 수술이 가능하며 만족할 만한 결과를 얻을 수 있었다.

  • PDF

개방형 자동굴절검사기의 주시거리에 따른 굴절이상도와 가상주시형 자동굴절 검사기의 굴절이상도와의 비교 연구 (A Study of Comparison Between Refractive Errors by Fixation Distance Variation with N-vision(open-view type) Auto-refractor and Refractive Error with Canon(Internal Fixation Target Type) Auto-refractor)

  • 김재도;김대현;전인철
    • 한국안광학회지
    • /
    • 제16권4호
    • /
    • pp.433-438
    • /
    • 2011
  • 목적: 개방형과 가상주시형 자동굴절검사기에 의한 굴절이상도를 비교하여 그 차이를 알아보고 개방형 검사기를 이용하여 정적굴절검사를 시행할 때 주시시표와 피검자와의 최소거리를 알아보고자 하였다. 방법: 교정시력 1.0 이상이고 안과적 질환이 없는 성인(22.2${\pm}$3.4세) 21명(42안)을 대상으로 자동굴절검사기에 의한 굴절검사를 실시하였다. 굴절검사는 가상주시형(RK-F1, Canon, Japan)을 사용하였으며 개방형(N-vision-K5001, Shin-nippon, Japan)을 사용하여 1 m, 3 m, 4 m, 6 m의 위치를 주시하는 상태에서 거리에 따른 굴절이상도를 비교하였다. 결과: 1 m 주시거리에서 개방형에 의한 전체대상자의 평균 굴절이상도(-2.75${\pm}$1.84 D)는 가상주시형에 의한 평균 굴절이상도(-2.95${\pm}$2.04 D)와 유의적인 차이가 없었다(p=0.06). 그러나 3 m, 4 m, 6m 주시거리에서 개방형에 의한 평균굴절이상도는 가상주시형에 의한 굴절이상도보다 낮은 근시성 굴절이상도를 보였다(p<0.05). 결론: 정적굴절검사를 위해 개방형 굴절검사기를 사용하는 경우 5~6 m의 검사거리를 확보하지 않더라도 3 m 이상의 측정거리에서도 가능하다.

Clinical and Radiological Results of Hook Plate Fixation in Acute Acromioclavicular Joint Dislocations and Distal Clavicle Fractures

  • Oh, Joo Han;Min, Seunggi;Jung, Jae Wook;Kim, Hee-June;Kim, Jae Yoon;Chung, Seok Won;Kim, Joon Yub;Yoon, Jong Pil
    • Clinics in Shoulder and Elbow
    • /
    • 제21권2호
    • /
    • pp.95-100
    • /
    • 2018
  • Background: The purpose of this study was to evaluate the clinical outcomes and complications of hook plate fixation in acromioclavicular (AC) joint dislocations and distal clavicle fractures. Methods: We retrospectively reviewed a series of 60 consecutive patients with hook plate fixation for AC joint dislocation (group I) and distal clavicle fracture (group II). Groups I and II had 39 and 21 patients, respectively. Clinical results were evaluated using the pain visual analogue scale (VAS), simple shoulder test, and Constant-Murley scores. In addition, subacromial erosion and stiffness were evaluated as complications. Results: At the removal, the pain VAS was $2.69{\pm}1.30$ and $4.10{\pm}2.14$ in groups I and II, respectively, which were significantly different (p=0.003). The simple shoulder test score was $9.59{\pm}1.60$ and $7.81{\pm}2.67$ in groups I and II, respectively, which were also significantly different (p=0.002). Subacromial erosion was significantly more frequent in group II (14/21 patients, 66.7%) than in group I (15/39 patients, 38.5%) (p=0.037), and stiffness was also higher in group II (17/21 patients, 81.0%) than in group I (22/39 patients, 56.4%), but it was not significant. Conclusions: Hook plate fixation showed good clinical and functional results for the treatment of acute unstable AC joint dislocation and distal clavicle fracture. But, in distal clavicle fractures, there are more subacromial erosion and stiffness compare with acute unstable AC joint dislocation.

Coracoclavicular Ligament Suture Augmentation with Anatomical Locking Plate Fixation for Distal Clavicle Fracture

  • Lim, Tae Kang;Shon, Min Soo;Ryu, Hyung Gon;Seo, Jae Sung;Park, Jae Hyun;Ko, Young;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • 제17권4호
    • /
    • pp.175-180
    • /
    • 2014
  • Background: For Neer type IIB fracture of distal clavicle with coracoclavicular ligament injury, various surgical treatments have been used in literatures. However, there was no consensus on the optimal treatment. The aim of this study is to report the clinical and radiological results of open reduction and internal fixation of unstable distal clavicle fracture and suture augmentation of disrupted coracoclavicular ligament. Methods: A prospective study was performed in 23 patients with Neer type IIB distal clavicle fracture in Seoul Medical Center, Eulji Hospital, and National Medical Center. Firstly, suture anchors are inserted in the base of coracoid process and preliminary reduction was achieved by tie-off of three suture limbs around the clavicle. Then, the final fixation was completed with anatomical locking plate. Bony union and the distance between coracoclavicular ligaments were evaluated. Clinical results and complications including stiffness and secondary procedures were evaluated. Results: Bony union was achieved in all cases except one (22 of 23). At mean 14.9 months, no significant difference in the mean coracoclavicular distance was observed compared to uninjured shoulder ($8.2{\pm}7.9mm$ versus $7.3{\pm}3.4mm$, p=0.14). Pain visual analogue scale, American Shoulder and Elbow Surgeons score, Constant score, and Disabilities of the Arm, Shoulder and Hand score were 0.5, 83.4, 78.5, and 6.2, respectively. Revision surgery was performed in one case of nonunion. Four patients who complained of skin irritation underwent implant removal. Conclusions: In cases of an unstable distal clavicle fracture with coracoclavicular ligament disruption, satisfactory clinical results were obtained by locking plate fixation and coracoclavicular ligament suture augmentation concurrently.