• Title/Summary/Keyword: visual defect

Search Result 191, Processing Time 0.03 seconds

Comparison between Moberg Flap and Second Toe Pulp Free Flap for Coverage of Tip Amputation of Thumb (무지 첨부 절단 환자 재건에서 Moberg Flap과 2족지 수질부 유리피판술의 비교)

  • Jung, Gang Jae;Ki, Sae Hwi;Kim, Jin Soo;Lee, Dong Chul;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.527-532
    • /
    • 2008
  • Purpose: Transverse type or volar oblique type of defect of thumb tip can be covered by Moberg flap or second toe pulp free flap. We compared these two methods in functional result, patients' satisfaction, and sensation, etc. to find a better way to cover the defect of the thumb tip. Methods: From 2003 to 2006, we chose the patients randomly with preoperative pictures. The patients had the defect of the thumb tip which is either transverse or volar oblique type. The 6 patients were treated with Moberg flap and other 6 patients were treated with second toe pulp free flap. We have analyzed the results by 2 point discrimination, side pinching power test, pulp to pulp pinching power test, pain scales (visual analogue scale), satisfaction scales of the patients (functional and aesthetic), the degree of the range of motion, etc. Results: All flaps survived without any complications. In the cases of Moberg flaps, the value of static 2 point discrimination test was 5.6 mm, and the value of moving 2 point discrimination test was 4.8 mm. In the cases of second toe pulp free flaps, the values were 9.6 mm and 9.3 mm. In the cases of Moberg flaps, the value of the Side pinch power test was 6.6 kg, 4.4 kg. In the case of second toe pulp free flaps, the values were 4.8 kg and 2.5 kg. The value of aesthetic satisfaction scale of the patients in Moberg flaps was 5.6, the value of functional satisfaction scale of the patients was 3.6. In cases of second toe pulp free flaps, the values were 5.6 and 3.6. The active range of motion of Interphalangeal joint in the cases of Moberg flaps was 46.6 degree, and the active range of motion of metacarpophalangeal joint was 55 degree, in the cases of second toe pulp free flaps, the values were 36.6 degree and 59 degree. Conclusion: As a result, when the defect of the thumb tip is transverse or volar oblique type, we suggest that the operators choose Moberg flap to cover the defect of the thumb tip.

Sensor Fusion System for Improving the Recognition Performance of 3D Object (3차원 물체의 인식 성능 향상을 위한 감각 융합 시스템)

  • Kim, Ji-Kyoung;Oh, Yeong-Jae;Chong, Kab-Sung;Wee, Jae-Woo;Lee, Chong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.107-109
    • /
    • 2004
  • In this paper, authors propose the sensor fusion system that can recognize multiple 3D objects from 2D projection images and tactile information. The proposed system focuses on improving recognition performance of 3D object. Unlike the conventional object recognition system that uses image sensor alone, the proposed method uses tactual sensors in addition to visual sensor. Neural network is used to fuse these informations. Tactual signals are obtained from the reaction force by the pressure sensors at the fingertips when unknown objects are grasped by four-fingered robot hand. The experiment evaluates the recognition rate and the number of teaming iterations of various objects. The merits of the proposed systems are not only the high performance of the learning ability but also the reliability of the system with tactual information for recognizing various objects even though visual information has a defect. The experimental results show that the proposed system can improve recognition rate and reduce learning time. These results verify the effectiveness of the proposed sensor fusion system as recognition scheme of 3D object.

  • PDF

A study on the development of dimension inspect Program for the vehicle axle casing nut welding part using digital image processing (디지털 화상처리를 이용한 차축 Casing Nut 용접부 치수 검사 프로그램 개발에 관한 연구)

  • 김재열
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.5
    • /
    • pp.135-143
    • /
    • 2000
  • The vision system is easy to use the exclusive use as a independent computer system but it is not much popularization by reason of expensive and difficult to adapt to the various fields, because it is easy to the existed computer system, the price is cheap and also it can use to the various measurement purpose which user wanted and programed. The measurement method of the vehicle axle casing nut welding part is that measure the value of the welding part to adapt the actual operation program from using the ratio between the actual length of the standard specimen and the length of image, to measure the ratio between the actual product and the camera image. A defect is found by the assembled visual inspection system. The inspection algorithm which estimates the quality of welded product is developed and also, the software program which processes the automatic test function of the inspection system. We make the foundation of the inspection automatic system and we will help to apply other welding machine.

  • PDF

Classification of Blowout Fracture (안와 파열 골절의 분류)

  • Lee, Jun Ho;Ryu, Min Hee;Kim, Yong Ha
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.719-723
    • /
    • 2007
  • Purpose: Blowout fracture can lead to functional impairments and esthetic deformities such as impairment of ocular movement, diplopia, visual loss and enophthalmos. The object of this study is to present a classification and its analysis according to the computed tomographic scan in blowout fractures. We classified blow out fractures into three types according to the anatomical location of fracture, the size of the bone defect and the degree of periosteal injury by using the computed tomography scan. Each progress and complications were analyzed more than mean 1 year. Methods: Among the 155 cases during 4 years, there were 11 cases of medial orbital wall fracture, 97 cases of inferior orbital wall fracture, 47 cases of combined type. The mean age of patients was 31.2 years, ranged from 8 to 84 years. Results: According to our classification, surgical treatments through the nasoendoscopic approach, the subciliary approach, the transconjunctival approach or their combinations were performed in 116 patients, and conservative treatments were done in 46 patients. Presurgical clinical findings of diplopia, impairment of ocular movement, enophthalmos of more than 2 mm were present in 62 patients. After surgical treatment, clinical findings were remained in 7 patients. Conclusion: We think that our classification according to computed tomographic scan is helpful for the indication and it may decrease the complications such as impairment of ocular movement, diplopia, visual loss and enophthalmos.

Quantitative Evaluation of Delamination Inside of Composite Materials by ESPI (ESPI를 이용한 복합재료 박리결함의 정량평가)

  • Kim, Koung-Suk;Yang, Kwang-Young;Kang, Ki-Soo;Ji, Chang-June
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.246-252
    • /
    • 2004
  • Electronic speckle pattern interferometry (ESPI) for quantitative evaluation of delaminations inside of a composite material plate is described. Delaminations caused by the impact on composite materials are difficult to detect visual inspection and ultrasonic testing due to non-homeogenous structure. This paper proposes the quantitative evaluation technique of the defects made in the composite plates by impact load. Artificial defects are introduced inside of the composite plate for the development of a reliable ESPI inspection technique. Real defects produced by impact tester are inspected and compared with the results of visual inspection which shows a good agreement within 5% error.

Research and Development of Electrode Surface Inspection System (전극 표면 검사 장치 연구 개발)

  • Oh, Choonsuk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.123-128
    • /
    • 2016
  • In manufacturing processing of a secondary battery, the visual inspection system is studied and developed to check the surface defects of the electrode plates. It consists of two parts, one is the hardware control and the other software implementation. The former is made up to the system configuration and the design of the optical system, the illuminations and the controllers. The latter is the detection algorithms of the surface defects. This system achieves the quality improvement of the electrode process and the price competitiveness. By using the proposed defects detection algorithms this system demonstrates the high reliability of spot, line, manhole, extraneous substance, scratch, and crater defect of a electrode plate surface.

TFT-LCD Defect Enhancement Using Frequency Sensitivity of HVS (인간 시각시스템의 주파수 감도를 이용한 TFT-LCD 결함 강조)

  • Oh, Jong-Hwan;Park, Kil-Houm
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.5
    • /
    • pp.20-27
    • /
    • 2007
  • Generally, the TFT-LCD image signal have nonuniform brightness and are composed of largely varying background signal, noise signal and abruptly changing Mura signal within Mura region. In this paper, Mura region enhancing algorithms using the proposed modified-MTF, which describes how human-visual-system's sensitivity varies in frequency domain, is proposed. The validity of the proposed algorithm was demonstrated ideal 1-dimensional signal and also then it was also tested TFT-LCD image. By the experimental results, the proposed algorithm is very effective in TFT-LCD image Mura enhancement.

Giant Sellar Xanthogranuloma after Surgical Treatment of Symptomatic Rathke's Cleft Cyst

  • Cho, Sung-Min;Cho, Hyok-Rae;Park, Yong-Seok;Chang, Hee-Gyeong
    • Brain Tumor Research and Treatment
    • /
    • v.6 no.2
    • /
    • pp.82-85
    • /
    • 2018
  • Extremely massive sellar xanthogranuloma (XG) are rare, and the surgical outcome and prognosis are not well known. XG remain unknown whether they are derived from Rathke's cleft cysts (RCCs) or craniopharyngiomas (CPs) following extensive inflammation and metaplasia, to the point that no epithelium is readily identifiable. These lesions usually tend to occur in younger patients (mean 28.3 years), have a smaller diameter, and remain primarily intrasellar region with infrequent calcification. This 36-year-old man presented our hospital with visual deterioration. At the time of visit, there were no neurological problems other than visual field defect and hormonal disorder. He visited our hospital in 2007 due to headache and decreased vision, and underwent transphenoid surgery for pituitary RCC. Since then, he has received treatment at our hospital for postoperative hormonal disorders. Through preoperative imaging study, the author suspected CP and underwent surgery. During the operation, the adhesion of the tumor to the surrounding major neurovascular structures was severe in the naked eyes, but the tumor could be removed more easily than expected. The postoperative histological findings were confirmed as XG. The postoperative course was uneventful. Compared to the previous literature, this case is a case where the size of XG is very large in a sellar region and it can be proved that it originated from the RCC. And regular follow-up is necessary to confirm the prognosis after surgery.

A Study on the Development of Quality Inspection System for Connector Components Used in Automotive Wiring (자동차 배선용 커넥터 부품의 품질 검사 시스템 개발에 관한 연구)

  • Ryu, Jeong-Tak;Kim, Pil-Seok;Lee, Hyeong-Ju
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.26 no.6
    • /
    • pp.11-16
    • /
    • 2021
  • In this paper, a quality inspection system was developed to identify the defective assembly of connectors used in automobile wiring. For waterproof connectors, an internal seal must be inserted for waterproofing. However, there are cases where it is omitted or double-inserted during production. An automatic inspection jig was designed using photosensors and touch switches to classify good and bad connector components. In the case of the existing visual inspection, 6,400 connectors were inspected when 5 people inspected for 8 hours. However, when using the inspection jig developed under the same conditions, 20,000 pieces were inspected. In other words, the productivity is greatly improved compared to the conventional visual inspection.

The Effect of Bromocriptine Treatment for Invasive Prolactinoma (침습성 프로락틴 분비 뇌하수체 선종에서 Bromocriptine의 치료효과)

  • Yang, Moon-Sool;Kim, Sun-Ho;Lim, Seung-Gil;Lee, Seung-Koo
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.4
    • /
    • pp.275-281
    • /
    • 2005
  • Objective: The prolactinoma is the most common pituitary tumor and sometimes shows severe invasiveness to the adjacent cavernous sinus, especially in the male patient. The dopamine agonist can be used as an alternative treatment modality to surgery. But, the transsphenoidal or transcranial approach for tumor removal has been more preferred treatment option of neurosurgeons in invasive prolactinoma. Especially rapid decompression of mass effect and resolution of the neurologic deficit is demanded. The prospective study is done in order to identify the therapeutic efficacy of bromocriptine as an initial treatment option for the invasive prolactionomas. Methods: Twenty patients with invasive prolactinoma were studied. Preoperative neurological and endocrinological evaluations were done, and size and invasiveness of the tumor was estimated on MRI. Bromocriptine was administrated by increasing dose planning reaching maximum dose at 1 month of treatment, with close neurological and endocrinological monitoring. At 3months after treatment, MRI was taken and decision was made whether to continue bromocriptine or to have surgical intervention. Results: Thirteen patients showed excellent result with only bromocriptine treatment. These patients showed not only marked reduction of tumor volume and prolactin level, but also, improving clinical symptoms and other hormonal deficits. 13patients who had visual field defect and decreased visual acuity had all improved visual symptoms. But, the remaining 4patients required surgical treatment due to insufficient reduction of tumor size inspite of normalized prolactin level within 3months. Remaining 2patients had $20{\sim}30%$ of tumor size reduction, but prolactin level was not normalized. One patient required radiation therapy. Conclusion: Bromociptine can be used as initial treatment for the invasive prolactinomas with careful monitoring of the neurological and endocrinological status. It should be carefully followed up for tumor size reduction within 3 months after initiation of treatment.