• 제목/요약/키워드: viscous

검색결과 2,151건 처리시간 0.024초

Time-resolved Observation of Field-dependent Magnetization Reversal Behavior in Co/Pd Multilayer Film

  • Ryu, Kwang-Su;Lee, Kyeong-Dong;Choe, Sug-Bong;Shin, Sung-Chul
    • Journal of Magnetics
    • /
    • 제8권3호
    • /
    • pp.108-112
    • /
    • 2003
  • We report the experimental finding that there exists a transition of magnetization reversal process with varying the applied field in Co/Pd multilayer. We have measured the wall-motion speed V and the nucleation rate R during magnetization reversal via time-resolved direct domain observation, where the magnetization reversal process of Co/Pd multilayer is found to take a transition from thermal activation process to viscous process at the critical field of about 1.87 H$\_$C/ (coercivity). In the thermal activation regime, we find that the field dependences of two activation volumes for the wall-motion process and the nucleation process are different with each other, which reveals that the wall-motion and nucleation experience completely different interactions. In the viscous regime, we find that the wall-mobility is much smaller than a typical value for the sandwiched Co films, which implies that the Co/Pd interfaces in multilayer substantially contribute to the dynamic dissipation.

정지공기중 점성유체 분류의 분열길이 측정 (Measurement of Breakup Length of Viscous Liquid Jet in Stagnant Air)

  • 임정현;류근영;임성빈;노수영
    • 한국분무공학회지
    • /
    • 제3권4호
    • /
    • pp.1-7
    • /
    • 1998
  • The measurement of breakup length of viscous liquid jet in stagnant air was conducted by a 3CCD digital video camera. The nozzle diameters of 4, 6, 8mm with L/d=50 were selected and the dynamic viscosity of viscous liquid made of glycerine and water was in the range of $1.061\times10^{-6}m^2/s$ to $4.935\times10^{-5}m^2/s$. The critical velocity is decreased and the breakup length is increased with the increase of nozzle diameter at the same dynamic viscosity of liquid. At the same nozzle diameter, the breakup length and the critical velocity are both increased with the increase of dynamic viscosity of liquid. It is found in the theoretical analysis that the initial disturbance level is the main cause of occurrance of critical Reynolds number in the stability curve. The comparison of experimental critical Reynolds number and the empirical correlation by Tanasawa and Toyota reveals the relatively good agreement.

  • PDF

Peristaltic 운동을 이용한 추진에 대한 연구 (Analysis for the Propulsion with Peristaltic Motion)

  • 김문찬
    • 대한조선학회논문집
    • /
    • 제39권4호
    • /
    • pp.11-16
    • /
    • 2002
  • 고점성 유체내에서의 추진력을 얻기 위하여 Peristatic 운동에 의한 추진을 실험적, 수치적 방법으로 연구하였다. 운동을 수치적으로 해석하기 위하여 비 정규격자를 사용한 셀 중심 법을 이용하여 해석하였다. 실험을 위하여 작은 수조를 만들었으며 모형을 끌 수 있는 전차와 고점성 액체인 그리세린을 사용하여 Peristaltic 운동을 구현하였다. 여러 조건 하에서 실험을 수행하였으며, 여러 실험 결과 중에서 가장 비교가 용이한 정지 상태에서 실험한 결과에 대하여 개발된 프로그램을 이용한 해석 결과와 비교하였다. 해석 결과는 실험 결과와 좋은 일치를 보였다. Peristaltic 운동은 압력 차를 이용하여 추진력이 얻어짐을 계산을 통하여 보였으며 더 많은 계산을 통하여 최적 운동조건이나 Peristatic 운동이 효과적인 영역(레이놀즈 수) 등을 찾아낼 수 있으리라 생각된다.

Dynamics of CO Rebinding to Protoheme in Viscous Solutions

  • Lee, Tae-Gon;Park, Jae-Heung;Kim, Joo-Young;Joo, Sang-Woo;Lim, Man-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권1호
    • /
    • pp.177-182
    • /
    • 2009
  • We present the geminate rebinding kinetics measurements of CO to 2-methylimidazole (2-MeIm) bound ferrous protoporphyrin- IX (FePPIX) in alkaline glycerol/water mixtures at 293 K after photolysis. The kinetics was probed by monitoring the CO stretching mode using femtosecond vibrational spectroscopy. When 2-MeIm is used in excess, heme dimers that typically form in low viscosity solutions disappear as the viscosity of the solvent increases. Heme aggregates formed in low viscosity solutions turn monomeric as more 2-MeIm is added, suggesting that 6-coordinated heme, including a strong proximal histidine tends to be in the monomeric form. The vibrational band of CO in the 2-MeIM-FePPIX-CO is well described by a single Gaussian function centered at 1958 $cm^-1$ and 28 $cm^-1$ full width at half maximum. The efficiency and rate of the geminate rebinding of CO to the heme increase with viscosity of the solvent, suggesting that retention of the dissociated CO near the heme, for a longer period by the viscous solvent media, accelerates rebinding.

인장과 휨변형하에서 목재의 응력이완 및 이론모형 (Stress Relaxation of Wood and Theoretical Models under Tensile and Bending Strain)

  • 장상식;강춘원
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권4호
    • /
    • pp.13-19
    • /
    • 1998
  • Stress relaxation tests have been performed under five different tensile strain levels and five different bending strain levels. Three different theoretical models have been developed based on four-element Burger's model, viscoelastic theory and viscous-viscoelastic theory. Experimental data were used to obtain parameters of the models and to verify accuracy of the models. Among the three theoretical models developed in this study, three-integral model (Model 3) based on viscous-viscoelastic theory showed the most exact estimations of stress relaxation under both tensile and bending strains and their correlation coefficients were greater than 0.99 for all the strain levels. Model 1 showed little initial stress relaxation. Model 2 showed excessive initial relaxation and, then, no relaxation after about 20 minute of strain application. Stress retention under strain decreased as strain increased, which means increased stress relaxation as strain increases. When the strain level was less than proportional limit, the effect of strain level on stress relaxation was not clearly shown. However, this effect was increased as strain level increased when strain level was greater than proportional limit.

  • PDF

점성 손실모델 도입에 의한 축류 압축기 준 3차원 압축성 유동해석 (A Study on the Quasi-3-Dimensional Compressible Flow Calculation by Introduction of Viscous Loss Model in Axial-Flow Compressor)

  • 조강래;이진호;김주환
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.1044-1051
    • /
    • 1989
  • 본 연구에서는 Wu가 제시한 수학적 모델에 기초를 둔 비점성 준3차원 유동해 석에 실제 유체의 점성효과 및 2차유동 등에 의해 발생하는 손실들을 손실모델로 반영하여 그 타당성 유무를 검토하는 데 목적을 두었다.

A Study for the Viscous Flow of Sodium Chloride Through a Cuprophane Membrane

  • Jee Jong-Gi;Kwun Oh Cheun;Jhon Mu Shik;Ree Taikyue
    • Bulletin of the Korean Chemical Society
    • /
    • 제3권1호
    • /
    • pp.23-30
    • /
    • 1982
  • For the study of transport phenomena of an aqueous NaCl solution through a cuprophane membrane, a new apparatus was constructed. The volumc flow rate Q, the permeability coefficient U, and the permeability constant K were measured or determined by using this apparatus. The experimental temperature range was 5 to $35^{\circ}C$, and the applied pressure increments were 10 to 40 psi. By assuming that the cuprophane membrane is composed of n parallel cylindrical capillaries of circular cross-section and that the flow of the solution through the capillaries follows the Poiseulle law, the mean radius r of the capillaries and the number n of the latter in the membrane were evaluated. By using a reasonable assumption concerning the radius ${\eta}'$ of the species diffusing through the membrane, it was concluded that the contribution of the diffusive flow to the total flow rate Q is less than 10%. Thus, the Q was treated as the rate due to the viscous flow, and the viscosity ${\eta}_m$ of the solution in the membrane phase was evaluted, and it was found that ηm is nearly equal to ${\eta}_b$, the bulk viscosity of the solution. From this fact, it was concluded that in the capillaries, no change occurs in the physical state of the NaCl solution. The value of ( = 4.27 kcal/mole) and ${\Delta}Sm^{\neq}$(4.28 eu) were obtained for the viscous flow. A possible explanation was given.

Vertical isolation of a structure based on different states of seismic performance

  • Milanchian, Reza;Hosseini, Mahmood;Nekooei, Masoud
    • Earthquakes and Structures
    • /
    • 제13권2호
    • /
    • pp.103-118
    • /
    • 2017
  • In vertical seismic isolation (VSI), a building is partitioned intentionally by vertical layers into two dynamically different substructures for seismic response reduction. Initially, a 1-story frame was partitioned into two substructures, interconnected by viscous and visco-elastic links, and seismic responses of the original and the vertically isolated structures (VIS) were obtained, considering a large number of stiffness and mass ratios of substructures with respect to the original structure. Color contour graphs were defined for presentation and investigation of large amounts of output results. Dynamic characteristics of the isolated structures were studied by considering the non-classical damping of the system, and then the effects of viscous and visco-elastic link parameters on the modal damping ratios were discussed. On this basis, three states of mass isolation, interactional state, and control mass were differentiated. Response history analyses were performed by Runge-Kutta numerical method. In these analyses, interaction of isolation ratios and link parameters, on response control of VIS was studied and the appropriate ranges for link parameters as well as the optimal ranges for isolation ratios were suggested. Results show that by using the VSI technique, seismic response reduction up to 50% in flexible substructure and even more in stiff substructure is achievable.

고점도 용액 정밀토출을 위한 노즐 직경 및 표면젖음성 특성 연구 (Study of the Geometry and Wettability of Nozzles for Precise Ejection of High Viscous Liquids)

  • 이상현;배재현;이상민
    • 한국기계가공학회지
    • /
    • 제20권12호
    • /
    • pp.123-128
    • /
    • 2021
  • Liquid dispensing systems are extensively used in various industries such as display, semiconductor, and battery manufacturing. Of the many types of dispensers, drop-on-demand piezoelectric jetting systems are widely used in semiconductor industries because of their ability to dispense minute volumes with high precision. However, due to the problems of nozzle clogging and undesirable dispensing behavior in these dispensers, which often result in device failure, the use of highly viscous fluids is limited. Accordingly, we studied the behaviors of droplet formation based on changes in viscosity. The effects of surface energy and the inner diameters of needle-type nozzles were also studied. Results showed that nozzles with lower surface energies reduced the ejection volume of droplets when a smaller nozzle diameter (0.21 mm in this study) was applied. These results indicate that the hydrophobic treatment of nozzle surfaces and the use of smaller nozzle diameters are critical factors enabling the use of highly viscous fluids in precision dispensing applications.

Effects of shear keys on seismic performance of an isolation system

  • Wei, Biao;Li, Chaobin;Jia, Xiaolong;He, Xuhui;Yang, Menggang
    • Smart Structures and Systems
    • /
    • 제24권3호
    • /
    • pp.345-360
    • /
    • 2019
  • The shear keys are set in a seismic isolation system to resist the long-term service loadings, and are cut off to isolate the earthquakes. This paper investigated the influence of shear keys on the seismic performance of a vertical spring-viscous damper-concave Coulomb friction isolation system by an incremental dynamic analysis (IDA) and a performance-based assessment. Results show that the cutting off process of shear keys should be simulated in a numerical analysis to accurately predict the seismic responses of isolation system. Ignoring the cutting off process of shear keys usually leads to untrue seismic responses in a numerical analysis, and many of them are unsafe for the design of isolated structure. And those errors will be increased by increasing the cutting off force of shear keys and decreasing the spring constant of shear keys, especially under a feeble earthquake. The viscous damping action postpones the cutting off time of shear keys during earthquakes, and reduces the seismic isolation efficiency. However, this point can be improved by increasing the spring constant of shear keys.