• Title/Summary/Keyword: virus safety

Search Result 265, Processing Time 0.03 seconds

Investigating Organ Toxicity Profile of Tenofovir and Tenofovir Nanoparticle on the Liver and Kidney: Experimental Animal Study

  • Peter, Aniekan Imo;Naidu, Edwin CS;Akang, Edidiong;Ogedengbe, Oluwatosin O;Offor, Ugochukwu;Rambharose, Sanjeev;Kalhapure, Rahul;Chuturgoon, Anil;Govender, Thirumala;Azu, Onyemaechi O
    • Toxicological Research
    • /
    • v.34 no.3
    • /
    • pp.221-229
    • /
    • 2018
  • Tenofovir nanoparticles are novel therapeutic intervention in human immunodeficiency virus (HIV) infection reaching the virus in their sanctuary sites. However, there has been no systemic toxicity testing of this formulation despite global concerns on the safety of nano drugs. Therefore, this study was designed to investigate the toxicity of Tenofovir nanoparticle (NTDF) on the liver and kidney using an animal model. Fifteen adult male Sprague-Dawley (SD) rats maintained at the animal house of the biomedical resources unit of the University of KwaZulu-Natal were weighed and divided into three groups. Control animals (A) were administered with normal saline (NS). The therapeutic doses of Tenofovir (TDF) and nanoparticles of Tenofovir (NTDF) were administered to group B and C and observed for signs of stress for four weeks after which animals were weighed and sacrificed. Liver and kidney were removed and fixed in formal saline, processed and stained using H/E, PAS and MT stains for light microscopy. Serum was obtained for renal function test (RFT) and liver function test (LFT). Cellular measurements and capturing were done using ImageJ and Leica software 2.0. Data were analysed using graph pad 6, p values < 0.05 were significant. We observed no signs of behavioural toxicity and no mortality during this study, however, in the kidneys, we reported mild morphological perturbations widening of Bowman's space, and vacuolations in glomerulus and tubules of TDF and NTDF animals. Also, there was a significant elevation of glycogen deposition in NTDF and TDF animals when compared with control. In the liver, there were mild histological changes with widening of sinusoidal spaces, vacuolations in hepatocytes and elevation of glycogen deposition in TDF and NTDF administered animals. In addition to this, there were no significant differences in stereological measurements and cell count, LFT, RFT, weight changes and organo-somatic index between treatment groups and control. In conclusion, NTDF and TDF in therapeutic doses can lead to mild hepatic and renal histological damage. Further studies are needed to understand the precise genetic mechanism.

Serological responses and protection levels in chickens administered with Newcastle disease vaccines

  • Geumji Seung;Jiye Kim;Hyobi Kim;Ji-Yeon Kim;Yang-Ho Jang;Yeon-Hee Kim;Moon Her;Seong-Joon Yi;Keun-Woo Lee;Il Jang;Young Ju Lee
    • Korean Journal of Veterinary Research
    • /
    • v.62 no.4
    • /
    • pp.29.1-29.7
    • /
    • 2022
  • Vaccination against Newcastle disease (ND) is the most effective means of controlling the disease, and these vaccines are commercialized only after their safety and effectiveness have been verified through tests that comply with Korean Standards of National Lot Release for Veterinary Biologics. This study investigated whether a relatively convenient and safe serological test can be used in place of the challenge test using highly virulent ND virus. Hemagglutination inhibition (HI) assay and enzyme-linked immunosorbent assay (ELISA) were considered positive of log2 2 or more and cutoff value of 200 or more, respectively, in both live and inactivated vaccines. However, when the antibody levels of the live and inactivated vaccines induced using the Ulster 2C, KBNP-C4152R2L, and K148/08 strains were compared, the antibody titers for inactivated vaccines were significantly higher than those for live vaccines in both the HI assay and ELISA. A strong positive correlation was observed between HI and ELISA antibody titers. The live vaccines corresponded to a survival rates of ≥ 80% and the inactivated vaccines corresponded to 100% survival rates. This study confirmed that standard efficacy tests can serve as serological tests, and can replace the challenge test and that the vaccine approval process can be improved.

Development and evaluation of a triplex real-time quantitative reverse transcription-polymerase chain reaction for rapid and differential detection of three feline respiratory viral pathogens

  • Ji-Su Baek;Jong-Min Kim;Hye-Ryung Kim;Ji-Hoon Park;Yeun-Kyung Shin;Hae-Eun Kang;Jung-Hoon Kwon;Won-Jae Lee;Min Jang;Sang-Kwon Lee;Ho-Seong Cho;Yeonsu Oh;Oh-Deog Kwon;Choi-Kyu Park
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.4
    • /
    • pp.269-281
    • /
    • 2023
  • In this study, a new triplex real-time quantitative reverse transcription polymerase chain reaction (tqRT-PCR) assay was developed for the rapid and differential detection of three feline viral pathogens including feline calicivirus (FCV), feline herpesvirus 1 (FHV-1), and influenza A virus (IAV) in a single reaction. The assay specifically amplified three targeted viral genes with a detection limit of below 10 copies/reaction. The assay showed high repeatability and reproducibility, with intra- and inter-assay coefficients of variation of less than 1%. Based on the diagnostic results of the assay using 120 clinical samples obtained from cats with feline respiratory disease complex (FRDC)-suspected signs, the prevalence of FCV, FHV-1, or IAV was 43.3%, 22.5%, or 0%, respectively, indicating that the diagnostic sensitivity was comparable or superior to those of previously reported monoplex qRT-PCR/qPCR assays. The dual infection rate for FCV and FHV-1 was 8.3%. These results indicate that FCV and FHV-1 are widespread and that co-infection with FCV and FHV-1 frequently occur in the Korean cat population. The developed tqRT-PCR assay will serve as a promising tool for etiological and epidemiological studies of these three bacterial pathogens, and the prevalence data for three feline viruses obtained in this study will contribute to expanding knowledge about the epidemiology of FRDC in the current Korean cat population.

The Comparison of Results Among Hepatitis B Test Reagents Using National Standard Substance (국가 표준물질을 이용한 B형 간염 검사 시약 간의 결과 비교)

  • Lee, Young-Ji;Sim, Seong-Jae;Back, Song-Ran;Seo, Mee-Hye;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.203-207
    • /
    • 2010
  • Purpose: Hepatitis B is infection caused by Hepatitis B virus (HBV). Currently, there are several methods, Kits and equipments for conducting Hepatitis B test. Due to ununiformed methods, it would cause some differences. To manage these differences, it needs process evaluating function of test system and reagent using particular standard substance. The aim of this study is to investigate tendency of RIA method's reagent used in Asan Medical Center through comparing several other test reagents using national standard substance. Materials and Methods: The standard substance in National Institute of Food and Drug Safety Evaluation's biology medicine consists of 5 things, 4 antigens and 1 antibody. We tested reagents using A, B company's Kits according to each test method. All tests are measured repeatedly to obtain accurate results. Results: Test result of "HBs Ag Mixed titer Performance panel" is obtained match rate compared S/CO unit standard with RIA method and EIA 3 reagents, CIA 2 reagents is that company A's reagent is 94.4% (17/18), 83.3% (15/18), B is 88.9% (16/18), 77.8% (14/18). Test result of "HBs Ag Low titer Performance panel" is obtain that EIA 2 reagents is shown 7 posive results, CIA 3 reagents is 11, and RIA method's company A's reagent is 3, B is 2 of 13 in low panel. "HBV surface antigen 86.76 IU/vial" tested dilution. A is obtain positive results to 600 times(0.14 IU/mL), B is 300 times (0.29 IU/mL). Case of "HBV human immunoglobulin 95.45 IU/vial", A is shown positive result to 10,000 times (9.5 mIU/mL) and B is 4,000 times (24 mIU/mL). Test result of "HBs Ag Working Standards 0.02~11.52 IU/mL" is shown that Company A's kit concentration level was 0.38IU/mL, company B was 2.23 IU/mL and higher level of concentration was positive results. Conclusion: When comparing various test reagents and RIA method according to National Standard substances for Hepatitis B test, we recognized that there were no significant trends between reagents. For hepatitis B virus antigen-antibody titers even in parts of the test up to 600 times the antigen, antibodies to 10,000 times the maximum positive results could be obtained. Therefore, we confirmed that results from Asan Medical Center are performed smoothly by reagents and system for hepatitis B virus test.

  • PDF

Simplified Procedure for Detection of Poliovirus and Norovirus in Oysters (굴로부터 오염된 폴리오바이러스 및 노로바이러스의 검출)

  • Ha, Sook-Hee;Woo, Gun-Jo;Kwak, Hyo-Sun;Hwang, In-Gyun;Choi, Weon-Sang
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1018-1023
    • /
    • 2005
  • Simplified procedure was developed for concentrating and detecting poliovirus and norovirus in oysters. Viruses were seeded into oyster tissue homogenates and concentrated through polyethylene glycol (PEG) precipitation, chloroform or Freon extraction, with additional PEG precipitation. Amount of viruses was evaluated using poliovirus plaque assay. Virus recovery during concentration procedure was approximately 16.4-26.0%. For defection, viral RNAs in oysters were examined using one-step RT-PCR after extraction with Trizol. Dilution or capturing of viral RNA using silica gel membrane allowed viruses to be detected by RT-PCR, whereas viruses could not be removed using $QIAshredder^{TM}$ Homogenizer, which is effective in removing RT-PCR inhibitors in lettuce and hamburgers. Freon extraction, generally used to concentrate viruses found in food, could be substituted with chloroform extraction using this procedure; no difference could be observed between detection limits of whole oyster extracts and digestive organ extracts indicating that RT-PCR inhibitors were distributed evenly throughout whole tissues. Nested PCR greatly improved efficiency of this procedure. Overall, this procedure could remove sufficient amount of inhibitors to allow detection of norovirus in oysters.

Profiling and Priority Selection of Foodborne Pathogens in Fresh Produce (국내 신선 농산물 생물학적 위해요소 우선순위 설정)

  • Lee, Chaeyoon;Sung, Dongeun;Oh, Sangsuk
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.356-365
    • /
    • 2012
  • There have been growing concerns among people about food safety due to insufficient information on foodborne pathogens. In this study, we developed a risk priority of 15 foodborne pathogens. For the priority determination we collected risk profile criteria information from CODEX Alimentarius Commission and developed countries. The basis for criteria we selected from information of surveillance were frequency and severity of disease, frequency of consumption and probability of cross-contamination. We also considered foodborne pathogens which have been managed in developed countries though those pathogens are not currently managed appropriately in Korea. Priorities were divided into three groups following these consideration. The first priority group includes Norovirus, pathogenic E. coli, Salmonella spp, Clostridium botulinum and Listeria monocytogenes. The second priority group includes Vibrio parahaemolyticus, Stapylococcus aureus, Campylobacter jejuni and Bacillus cereus, and the third priority group includes Clostridium perfringens, Yersinia enterocolitica, Shigella spp, Cronobacter sakazakii and Hepatitis A virus. Our results could be applied to prevent foodborne illness from fresh produce.

Designing a Molecular Diagnostic Laboratory for Testing Highly Pathogenic Viruses (고병원성 바이러스 검사를 위한 분자진단검사실 구축)

  • Jung, Tae Won;Jung, Jaeyoung;Kim, Sunghyun;Kim, Young-Kwon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.2
    • /
    • pp.143-150
    • /
    • 2021
  • The recent spread of novel and highly variant pathogenic viruses, including the coronavirus (SARS-CoV-2), has increased the demand for diagnostic testing for rapid confirmation. This has resulted in investigating the functional capability of each space, and preparing facility guidelines to secure the safety of medical technologists. During viral evaluations, there is a requirement of negative pressure facilities along with thread separation, during pre-treatment of samples and before nucleic acid amplification. Space composition therefore needs to be planned by considering unidirectional air flow. This classification of safety management facilities is designated as biosafety level 2, and personal protective equipment is placed accordingly. In case of handling dangerous materials, they need to be carried out of the biosafety cabinet, and sterilizers are required for suitable disposal of infectious agents. A common feature of domestic laboratories is maintenance of the sample pre-treatment space at a negative pressure of -2.5 Pa or less, and arranging separate pre-treatment and reagent preparation spaces during the test process. We believe that the data generated in this study is meaningful, and offers an efficient direction and detailed flow for separation of the inspection process and space functions. Moreover, this study introduces construction of the laboratory by applying the safety management standards.

Safety, tolerability, and immunogenicity of PIKA-adjuvanted recombinant SARS-CoV-2 spike protein subunit vaccine in healthy adults: an open-label randomized phase I clinical trial

  • Renan James Lim;Xiangyan Qiu;Robert Neil Leong;Jose Limuel Gutierrez;Ahmad Halima;Mohamed Mostafa;Yasser Ghoneim;Mostafa Abdrabo;Moaz Rashad;Suad Hannawi;Yuan Liu;Zenaida Mojares
    • Clinical and Experimental Vaccine Research
    • /
    • v.13 no.4
    • /
    • pp.315-328
    • /
    • 2024
  • Purpose: This phase I study aimed to assess the safety, tolerability, and immunogenicity of the PIKA-adjuvanted recombinant severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike (S) protein subunit vaccine in healthy adults aged 18 years and older. Materials and Methods: This is a phase I, open-label, dose-escalation study at three dose levels (5 ㎍, 10 ㎍, and 20 ㎍) of the PIKA coronavirus disease 2019 (COVID-19) vaccine administered intramuscularly. The three vaccine arms are (A) subjects who have never received any COVID-19 vaccination or have had COVID-19 infection for >6 months prior to enrolment; (B1) subjects whose COVID-19 primary vaccination series was completed with an inactivated COVID-19 vaccine; and (B2) subjects whose primary series was completed with messenger RNA COVID-19 vaccine. Results: Subjects who reported solicited adverse events (AEs) within seven days post-vaccination ranged from 35% to 60% within each vaccine arm. Most solicited AEs were mild local pain and tenderness. Systemic solicited AEs were only reported in Arm A. In all three vaccine arms, neutralizing antibody geometric mean titers were highest at day 28 (Arms B1 and B2) or day 35 (Arm A) than at baseline for all dose levels against the Wuhan (wild original SARS-CoV-2 virus, Wuhan-Hu-1), Delta (B.1.617.2), and Omicron (B.1.1.529) variants. These were sustained at day 183. Seroconversion rates at day 35 (Arm A, 85.7%-92.9%) or day 183 (Arms B1, 90.9%-100.0%, and B2, 18.2%-36.4%) and geometric mean fold rises were highest in the 5-㎍ dose level against all three variants. Conclusion: The PIKA-adjuvanted recombinant SARS-CoV-2 S protein subunit vaccine showed promising immunogenicity profile with no safety concerns. A dose-dependent immune response was observed, with slight advantages seen in low-dose (5 ㎍ and 10 ㎍) groups (ClinicalTrials.gov registration number: NCT05305300).

Pharmacokinetic Propertiese of Entecavir 1 mg in Korean Healthy Volunteers (건강한 한국인 피험자에서 Entecavir 1 mg 제제의 약동학적 특성 평가)

  • Jeon, Ji-Young;Hwang, Min-Ho;Im, Yong-Jin;Kim, Yun-Jeong;Han, Su-Mi;Im, Sung-Hyuk;Chae, Soo-Wan;Kim, Min-Gul
    • Korean Journal of Clinical Pharmacy
    • /
    • v.21 no.3
    • /
    • pp.224-227
    • /
    • 2011
  • Entecavir is a potent and selective guanosine analogue that has demonstrated a significant antiviral efficacy against hepatitis B virus (HBV). The aim of this study was to evaluate the safety and pharmacokinetic profile after a single dose of entecavir 1 mg administration in Korean healthy male subjects. Eight volunteers were enrolled. After a single dose of 1 mg entecavir was orally administered, blood samples were collected at specific time intervals from 0-168 hours. The plasma concentrations of entecavir were determined by LC-MS/MS. The pharmacokinetic parameters were determined from the plasma concentration-time profiles. The mean values for $AUC_{last}$ and $AUC_{inf}$ were $14.84{\pm}7.81ng{\cdot}hr/mL$ and $20.71{\pm}8.80ng{\cdot}hr/mL$, respectively. The mean value for $C_{max}$ was $9.19{\pm}4.91ng/ml$ and median value for $t_{max}$ was 0.58 hr. No adverse events were reported by subjects or found on analysis of vital signs or laboratory tests. The results are suggested to be useful in clinical trials of entecavir in Korean subject including bioequivalence study.

Characterization of the Repetitive Sequences Present in the ORF25 Genomic Region of Megalocytiviruses from Ornamental Fishes (관상어로부터 분리한 Megalocytiviruses에서 나타나는 ORF25 유전자 부위의 반복서열 특성 분석)

  • Jin, Ji-Woong;Nam, Jeong-Hee;Kim, Kwang-Il;Hong, Su-Hee;Byon, Ju-Young;Jeong, Hyun-Do
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.4
    • /
    • pp.352-358
    • /
    • 2011
  • The presence of ISKNV-like viruses in various freshwater ornamental fish species imported from Asia was confirmed by polymerase chain reaction(PCR) amplification of the ATPase(adenosine triphosphatase) gene. Interestingly, molecular analyses of the Open Reading Frame 25(ORF25) region of these isolates based on the ISKNV(Infectious spleen and kidney necrosis virus) genome revealed the presence of various repetitive sequences. ORF25 repeat sequence length had no effect on cumulative mortality of rock bream Oplegnathus fasciatus challenged with tissue homogenates of infected pearl gourami, Trichogaster leeri; silver gourami, Trichogaster microlepis; blue gourami, or Trichogaster trichopterus. All isolates induce cumulative mortalities after 12 days of infection, confirming that ORF25 polymorphism did not affect the pathogenicity of ornamental fish megalocytiviruses that cross infect rock bream, a seawater fish. Also, no statistically significant differences in spleen index or viral copy number in infected tissues was detected between isolates with varying ORF25 repeat sequence lengths. However, further studies are necessary to fully characterize the functional characteristics of these polymorphisms in megalocytivirus disease in ornamental fishes.