• 제목/요약/키워드: vinyl chloride

검색결과 269건 처리시간 0.023초

Ultrathin Polymer Networks of Itaconic Acid Copolymers and Poly(allkylamine) by the ;angmuir-Blodgett Technique

  • 최기선;이범종;장상목;권영수
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권6호
    • /
    • pp.493-498
    • /
    • 1995
  • Ultrathin networks of itaconic acid copolymers and poly(allylamine) were produced by a Langmuir-Blodgett (LB) technique employing a double-chain amine as a monolayer template which was subsequently removed by extraction after thermal crosslinking. Itaconic acid copolymers used were copoly (itaconic acid-ethyl vinyl ether) and copoly (itaconic acid-n-butyl vinyl ether). The polyion-complexed monolayers of three components consisting of template amine, itaconic acid copolymer and poly (allylamine) were formed at the air-water interface. The Langmuir film properties have been studied by the surface pressure-area isotherm and fluorescence microscopy. The monolayers were transferred on solid substrates and were characterized by FT-IR spectroscopy, X-ray photoelectron spectroscopy, and scanning electron microscopy (SEM). Two-dimensional polymer networks were formed through imide or amide linkages by heat treatment under vacuum. The heat-treated films were extracted with chloroform after immersion in aq. sodium chloride to remove the template amines. SEM observation of a LB film on a porous fluorocarbon membrane filter with pore diameter of 0.1 μm showed covering of the pores by six layers in the polyion complex state.

스프링클러 시스템에서 조도계수에 따른 CPVC 배관 마찰손실 영향의 연구 (A study on the effects of Friction loss of CPVC pipe according to Roughness coefficient in a sprinkler system)

  • 강웅일
    • 한국산학기술학회논문지
    • /
    • 제17권11호
    • /
    • pp.355-362
    • /
    • 2016
  • 배관 내에 유체가 흐를 때 사용되는 유체의 물리 화학적 성질에 따라 배관재질이 선택이 결정된다. 수계소화설비에 사용하는 유체는 대부분 물을 사용하므로 물속에 용해된 각종 이물질들은 관 벽에 스케일을 발생시키고 부식 및 배관 노후화를 촉진하여 마찰손실을 증가시켜 펌프의 효율을 저하시킨다. 이러한 요인을 가져오는 강관의 대체가능한 CPVC 배관은 부식에 강하고, 매끄러운 조도를 가지고 있어서 유체이송능력이 뛰어나고 배관무게가 가볍고 접착제결합 방식의 배관작업으로 시공성이 우수한 점을 들 수 있다. 그래서 설계 및 시공단계에서 마찰손실을 줄이기 위해 Hazen-Williams식을 CPVC(Chlorinated Poly-Vinyl Chloride)배관에 적용하여 조도계수에 따라 마찰손실을 조사하였다. 실제 아파트 현장에서의 적용사례를 통해 조도계수의 차이에 따라 손실수두를 조사한 결과 조도계수의 수치가 120인 강관일 때 마찰손실은 76.64MPa이고 150인 CPVC배관일 때 마찰손실은 50.72 MPa로서 34% 정도의 마찰손실이 개선되었음을 확인하였다. 또한 시공비 절감차원에서는 강관으로 시공할 때 1,585,158원이고 CPVC배관으로 시공 시에는 931,842원으로 41%정도의 시공비가 절감되는 것을 확인하여 전체 설비용량의 감소로 인한 소화시스템의 안정성 향상 및 시공비를 절감할 수 있는 것을 알 수 있었다.

폴리카프로락톤 (PCL)/폴리염화비닐(PVC) 블렌드의 기계적 성질 및 반가소화 현상 (Mechanical Properties and Antiplasticization Phenomena of Poly(${\varepsilon}$-caprolactone)(PCL)/Poly(vinyl chloride)(PVC) Blends)

  • 김욱수;김일형;강선철;;;하기룡
    • 폴리머
    • /
    • 제25권4호
    • /
    • pp.521-527
    • /
    • 2001
  • 폴리카프로락톤 (PCL)/폴리염화비닐(PVC) 블렌드 시스템에서 PCL 조성 5 ~ 23%에 대한 상용성, 기계적 성질과 분자간의 상효작용에 대하여 연구하였다. 유리전이온도(T$_g$) 거동을 토대로 용융 혼합된 블렌드의 상용성을 측정한 결과 분자 수준으로 혼합되었다는 것을 관찰하였으며, PCL의 함량이 증가함에 따라 블렌드의 T$_g$는 낮은 온도 쪽으로 이동하였다. 또한 PCL/PVC 블렌드에 대하여 Fox식을 이용하여 예측한 T$_g$값과 실험에서 측정된 T$_g$값은 잘 일치하였다. 따라서 PCL/PVC 블렌드 시스템은 PCL 함량이 5 ~ 23%에서 무정형 고분자임을 나타낸다. 또한 분자간의 상호작용이 기계적 물성에 미치는 영향을 관찰하기 위하여 인장 강도, 탄성률 및 항복 강도와 같은 기계적 물성을 측정하여 관찰하였다. 그 결과 탄성률과 항복 강도 값은 PCL 함량이 약 5%에서, 인장 강도 값은 PCL 함량이 11%에서 최대값을 나타내었다. 그리고 PCL 함량 13%이상까지는 인장 강도 값이 순수 PVC보다 높았으며, 신장률은 낮은 값을 나타내었다. 결과적으로 PCL/PVC 블렌드 시스템은 PCL 함량이 약 13%까지 T$_g$값은 내려가고, 인장 강도는 증가하면서 신장률은 감소하는 반가소화 현상을 나타내었다.

  • PDF

스피노달 분해와 기핵성장에 따른 상분리 과정의 광산란 패턴의 관찰 (The Observation of Scattering Patterns During Membrane Formation: Spinodal Decomposition and Nucleation Growth)

  • 강종석;허훈;이영무
    • 멤브레인
    • /
    • 제12권2호
    • /
    • pp.97-106
    • /
    • 2002
  • Polysulfone (PSf/NMP/alcohol 용액과 chlorinated poly(vinyl chloride) (CPVC)/THF/Alcohol 용액에 대한 광산란 패턴을 SALS (Small angle light scattering)와 FE-SEM (field emission scanning electron microscope)을 이용하여 조사하였다. PSf 용액에서는 시간에 따라 q값의 최대 산란 강도를 보이는 광산란 거동을 나타내어 스피노달 (SD) 상분리 거동을 나타내는 반면, CPVC 용액에서는 q값이 증가함에 따라 광산란 강도가 줄어드는 핵성장 (NG) 거동을 나타냈다. 각 고분자 용액에서 상분리 중반과 후반부에서 비용매 첨가제로 사용된 알코올의 탄소수가 증가할수록 농도분극의 증가율은 줄어들었다. 또한, SD에서의 초반부의 시간에 따른 산란 강도는 비용매 첨가제의 종류에 무관하게 Cahn의 건형 이론에 잘 부합되었다. 또한, SALS 장치로 얻어진 기공크기와 전자현미경으로 얻어진 영역 크기는 상호간에 비교되었다. 20PSf/70NMP/10n-butano1 (w/w%) 용액에 대한 산란 패턴은 초기 상분리 거동에서부터 후기 거동까지 매우 선명하게 관측되었고, 초반, 중반, 그리고 후반부에 대한 SD에 대한 이론적 결과와 잘 일치하였다. 최고의 산란강도를 나타낸 각도의 크기는 n-butanol>n-propanol>methanol>no alcohol 순으로 관찰되었으며, 이 순서로 최종 형성된 막 단면의 기공 크기가 감소되는 것으로 조사되었다.

공기중 염화비닐단량체의 포집시 공기 포집량이 파과에 미치는 영향 (Effect of sampling volume on the breakthrough of charcoal tube during vinyl chloride monomer sampling)

  • 윤존중;임남구;김치년;노재훈
    • 한국산업보건학회지
    • /
    • 제11권3호
    • /
    • pp.241-248
    • /
    • 2001
  • The main factors of breakthrough are known to sampling time, flow rate, concentration of the sample, temperature, humidity, and the physical characteristics of the solid sorbent tube. However, no study has been reported the effect of temperature and sampling volume on the breakthrough of acharcoal tube during vinyl chloride monomer (VCM) sampling. The objective of this study is to suggest the optimal sampling condition during VCM sampling based on National Institute for Occupational Safety and Health (NIOSH) method. To evaluate adequate sampling volume for VCM without breakthrough, volume of 1, 2, 3, 4, and 5 L each from VCM of 1, 5, 10, 15, and 20ppm at flow rate of 0.05 L/min were sampled in $22^{\circ}C$ and $40^{\circ}C$. At $22^{\circ}C$, in the case of 1, 5, 10, and 15ppm, VCM was adsorbed completely in first section of charcoal tube regardless of sampling volume. But in 20ppm, detection rates are 99.56% in first section and 0.44% in second section. At $40^{\circ}C$ of 1ppm, VCM was adsorbed completely in first section. In 10, 15, and 20ppm, detection rates of second, third, and forth sections were decreased significantly by reduction of sampling volume. In determination of breakthrough based on NIOSH method, no breakthrough was occurred in 20ppm at $22^{\circ}C$. At $40^{\circ}C$, breakthrough was occurred in 10, 15, and 20ppm when sampling volume was 5L. Although no breakthrough was occurred when sampling volume was 3L. Finally, in environment of temperature around $22^{\circ}C$, breakthrough may not occurred up to 20ppm during sampling for VCM. During sampling for VCM in environment of temperature around $40^{\circ}C$, no breakthrough occurred in 1-5ppm and 10-20ppm when sampling volume is 5L and 3L respectively. This result suggests that the sampling volume should be considered when VCM sampling under hot conditions (> $22^{\circ}C$) by the NIOSH method No. 1007.

  • PDF

일부 PVC 수지 제조 및 가공 근로자의 염화비닐 폭로 평가와 대책에 관한 조사 연구 (A Study on the Control and Exposure Assessment to Vinyl Chloride in the Factory Processing and Producing PVC Resin)

  • 박동욱;신용철;이나루;이광용;오세민;정호근
    • 한국산업보건학회지
    • /
    • 제4권1호
    • /
    • pp.33-42
    • /
    • 1994
  • This study was carried out to assess worker exposure to vinyl chloride monomer (VCM) and to present control measures in the factories processing and producing polyvinyl chloride (PVC) resin. The conclusion remarks are as follows. Only two personal samples in the factory ("E") processing polyvinyl chloride resin were analysed to be 27.6 ppm and 12.6 ppm, respectively. But, these concentration exceed 1 ppm, Permissible Exposure Limits (PEL) of OSHA. So, worker's exposure to VCM at "E" factory should be reevaluated. In "A", "B" and "C" factory producing polyvinyl chloride resin, the average worker's exposures to VCM were 0.12 ppm, 0.86 ppm and 1.23 ppm, respectivery. Worker exposure to VCM at distillation and dry process was higer than other processes at "A" factory. The average exposure concentration of worker at polymerization process of "B" and "C" factory was 1.23 ppm, and 1.46 ppm respcetively. These concentration exceed 1 ppm, Permissible Exposure Limits of OSHA. Control room of "B" and "C" factory had 0.91 ppm and 0.65 ppm of worker's exposure concentration respectively. "A" factory was evaluated to be "acceptable", but "B" and "C" factories were evaluated to be "not acceptable", by the workplace exposure assessment program of AIHA. Process other than bagging and control room of "A" factory was evaluated to "not acceptable". Immediate correction measures for preventing workers from exposure to VCM should be performed in the factories or process that were evaluated to be "not acceptable". After these control measures are taken, worker exposure to VCM must be reevaluated through personal air monitoring. Control measures presented by this study are complete sealing of connecting pipe lines, flanging, packing, bolting and nutting. Periodic leak test for leak parts is also required. And positive pressure facility should be constructed at control room of "B" and "C" factory. Fresh air through cleaner such as HEPA filter should be supplied to control room. In addition to these control measures, periodic personal monitoring for evaluating worker exposure to VCM should be performed.

  • PDF

PVC의 방사선 안정화에 관한 연구 (I) (Study on the Radiation Stabilization of Poly(vinyl chloride) (I))

  • 김기엽
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제5권2호
    • /
    • pp.237-243
    • /
    • 1992
  • 무독성 혼합안정제인 Zn/Ca-stearate의 방사선 안정화 효과를 증진시키기 위해서 안정화 조제로 알코올들을 PVC에 배합하여 방사선 조사하였을 때 PVC의 색차변화를 측정하여 이들 안정화 조제의 방사선 안정화 효과를 비교 검토하였다. 2가알코올에 의한 PVC 안정화 효과는 2가알코올의 주쇄길이에 비례하여 나타나고 있으나 sorbitol을 제외한 다가알코올에 의한 PVC 안정화 효과는 거의 없는 것으로 나타났다. 이들 알코올에 의한 PVC의 방사선 안정화는 2가알코올이 PVC에서 발생된 고분자 라디칼에 대한 라디칼 포착제로서 작용하기 때문인 것으로 판단된다.

  • PDF

공기분위기에서 ZnO를 첨가한 PVC와 PS 혼합물의 분해특성에 관한 연구 (A Study on the Decomposition Characteristics of PVC and PS Mixtures with ZnO in Air Atmosphere)

  • 오세천;정명욱;전현철;김희택;이해평
    • 공업화학
    • /
    • 제17권2호
    • /
    • pp.229-234
    • /
    • 2006
  • 공기분위기에서 PVC와 PS의 혼합 분해시 ZnO의 영향에 관한 연구를 혼합비율 및 반응온도를 변화시키며 TG와 GC-MS를 이용하여 수행하였다. 본 연구로부터 혼합물에 있어서 PS의 양이 증가할수록 액상 생성물은 증가하였으며 기상 생성물은 감소함을 알 수 있었다. 또한 혼합물에 있어서 ZnO의 첨가량이 증가할수록 가스 생성물과 염화수소의 발생량은 감소하였으며 ZnO/Mixture = 0.5인 경우 ZnO의 영향에 의하여 염화수소가 거의 생성되지 않음을 확인할 수 있었다.

새로운 캘릭스[4]아렌 유도체를 이용한 $Pb^{2+}$ 이온 친화성 막전극 (The $Pb^{2+}$ Ion Affinitive Membrane Electrode Based on New Calix[4]arene Ionophore)

  • 김은진;김민규;남궁미옥;백경수;윤영자
    • 대한화학회지
    • /
    • 제42권5호
    • /
    • pp.531-538
    • /
    • 1998
  • 캘릭스[4]아렌 유도체(호스트 1)를 이온선택성 물질로 사용하고, 지지체로 poly(vinyl chloride)(PVC), 가소제로 dioctylsebacate(DOS)를 사용하여 이온 선택성 막전극을 제작하였다. 호스트 1 막전극을 지시전극으로 사용하여 알칼리, 알칼리 토금속 양이온 그리고 전이 금속 양이온에 대하여 각각의 감응전위를 측정한 결과, 바탕 전해질이 탈 이온수 일때 $Pb^{2+}$의 감응전위가 $1.0 \times10^-6M~1.0 \times 10^-1 M$ 농도 범위에서 이론적인 Nernstian 감응전위 기울기에 가까운 26.5mV/decade를 보여 주었다. 또한 pH 영향을 조사해 본 결과 pH 4.00∼12.00 범위에서 감응전위값이 일정하게 유지되었다. 따라서 본 연구에서 제작된 호스트 1 막전극은 탈이온수 상에서 $Pb^{2+}$에 친화성을 갖는 이온 막전극으로 나타났다.

  • PDF