• Title/Summary/Keyword: vibrator

Search Result 296, Processing Time 0.03 seconds

Design of Vibrating Transducer for Implantable Middle Ear Hearing Aid (이식형 중이 청각보조기를 위한 진동 트랜스듀서의 설계)

  • 박형욱
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.535-544
    • /
    • 1996
  • In this paper, we analyzed the coil-magnet type vibrating transducer for the implantable middle ear hearing aid which is appropriate for patient's hearing level, and an experimental transducer system is designed For the objective and quantitative analysis of the transducer, a theoretical equivalent model containing coil, magneto and inner ear is developed To perform effective evaluation of the transducer, a transforming ratio Tr is introduced and its range that is suitable for practical implantable middle ear hearing device is foun4 The result of applying physical parameters of ear system to the proposed analytical model shows that frequency response of the coil magrlet type vibrator is predominantly governed by resistive impedance of the coil rather than inertia effect of the magnet and the inner parameters. In addition, we realized an experimental middle ear hearing aid system to show the theoretical validity of designed system and this will provide the basis of the development for actually implantable system.

  • PDF

BONE CONDUCTION TELEPHONE FOR THE HEARING IMPAIRED

  • Kang, Kyeongok;Kang, Seonghoon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.1064-1069
    • /
    • 1994
  • In order to realize the function of human interface of telecommunications whose objective is to interchange useful information among persons, we developed a bone conduction telephone with which hearing impaired persons with conductive or noise-induced hearing loss and presbycusis can communicate with each other without any other additional devices such as hearing aids. The bone conduction telephone we developed has chatacteristics as follows : (i) a hearing impaired person and a normal hearing person can communicate by bone and air conduction hearings, respectively, using only this telephone set because, as its receiver, it uses a bone conduction vibrator with which we can realize such function with the voice coil and damper of a small speaker unit, the vibrating plate, etc., (ii) it has tone control function compensating hearing losses of hearing impaired persons according to their hearing loss/frequency chatacteristics. Using the tone control function together with a received volume control, it has the received volume range of 20dB in loudness rating; and (iii) it has the function of three emergency calls and a bell lamp as the visual display of a received call.

  • PDF

Displacements of the flexible ring for an electromechanical integrated harmonic piezodrive system

  • Xu, Lizhong;Li, Huaiyong;Li, Chong
    • Structural Engineering and Mechanics
    • /
    • v.60 no.6
    • /
    • pp.1079-1092
    • /
    • 2016
  • In this paper, an electromechanical integrated harmonic piezodrive system is proposed. The operating principle of the drive system is introduced. The equation of the relationship between the displacements of the flexible ring and the rotating angle of the rotor is deduced. Using the equation, the displacements of the flexible ring for the drive system and their changes along with the system parameters are investigated. The results show that the displacements of the flexible ring changes periodically along with the rotation of the vibrator; there are abrupt changes in the displacements of the flexible ring at some points where there are abrupt changes in the number of the mesh teeth pair; the length of the flexible ring, the excitation voltage, and the speed ratio have obvious effects on the displacements of the flexible ring. The results are useful for the design of the drive system. ;

Structural and Vibration Analysis of On-shore Drilling System Consisting of Shale Shaker (시추용 육상 드릴링 시스템의 셰일 쉐이커 구조 및 진동해석)

  • Ban, Im-jun;Lim, Chae-og;Shin, Sung-chul
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.1033-1042
    • /
    • 2020
  • Shale shaker which is one of the mud circulation systems is composed of a basket, a vibrator and a screen. Its purpose of a shale shaker is to induce drilling fluid to flow through a screen, transport solids across a screen surface, and discharge solids off the end of the screen. The new shale shaker for the on-shore drilling system is designed to be smaller than the original shale shaker which has the same capacity with the new on to enable to transport and to operate on the trailer. In this study, structural and vibrational analysis of shale shaker was carried out to evaluate the appropriateness of the design in terms of the structural stability.

Design of Manipulator End Effectors for Pier Column Construction (교각 기둥시공을 위한 매니퓰레이터 엔드 이펙터 설계)

  • Chung, Taeil;Lee, Sang-Won;Lee, Sang-Yoon;Ryu, Jee-Hwan
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.3
    • /
    • pp.207-215
    • /
    • 2021
  • There is a risk of serious injury to workers who work at height in pier construction process. By using auto climbing formwork system that does not need to dismantle and reinstall formworks, it is possible to improve work efficiency and safety of workers. However, auto climbing formwork system still requires workers to work on a pier for rebar connection works and so on. In order to eliminate works by workers on the pier, robot manipulators with special end effectors are proposed. Through analysis of works on the pier, three specialized end effectors which are a gripper, a rebar coupler press, and a concrete vibrator, are suggested. Also, new pier construction scenario by the suggested system is confirmed using 3d modeling. It is expected that the proposed system and method enables pier construction without workers on piers. It will increase safety and efficiency of pier construction.

After Hemorrhoidectomy Korean Medicine Treatment with Whidam's SuGi Therapy: A Case Report (치핵근치술 후 휘담식 수기요법을 병행한 한방관리 증례 1)

  • Hyungil Choi;Na Young Kim;Hun Mo Ahn
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.22 no.1
    • /
    • pp.72-82
    • /
    • 2023
  • Objective : The purpose of this study is to report about a 50's female patient after Hemorrhoidectomy, whose symptoms were relieved after Korean medicine treatment with Whidam's SuGi Therapy. Methods : The patient in this study received Korean medicine treatment such as herbal medication, acupuncture treatment, cupping therapy and specially Whidam's SuGi therapy. Results : After the treatment, the symptoms of pains were relieved. Vas fell from 9 to 2 and overall, the body condition has improved. Conclusions : This study showed that Whidam's SuGi therapy added with Korean Medicine treatment can be an effective choice for after Hemorrhoidectomy.

Oxygen Consumption and Ammonia Excretion in Cultured Soft-Shelled Turtle, Pelodiscus sinensis Exposed Vibration Stress (진동 스트레스에 따른 양식 자라, Pelodiscus sinensis의 산소소비 및 암모니아 배설)

  • Lee, Jeong-Yeol;Sung, Young-Sik;Hur, Jun-Wook
    • Journal of Aquaculture
    • /
    • v.20 no.1
    • /
    • pp.60-64
    • /
    • 2007
  • We examined the effects of the vibration stress on oxygen consumption and ammonia excretion of cultured soft-shelled turtle, Pelodiscus sinensis. For the stressed group vibration of $45{\sim}78\;dB$ (V) from electric vibrator was turned on for 15 min with 2-h intervals during daytime hours ($08:00{\sim}18:00$) for 28 days. Two different sizes of soft-shelled turtle, large (carapace length: $12{\sim}16\;cm$, body weight: $300{\sim}600\;g$, large size turtle: LST) and middle ($16{\sim}20\;cm,\;700{\sim}1,000\;g$, middle size turtle: MST) were used. The oxygen consumption of LST the beginning of the experiment (1 day) was 124.30 mg $O_2/kg/hr$, and after 7, 14, 21 and 28 days of stress decreased by 47.2, 71.6, 79.1 and 86.0%, respectively. In MST, oxygen consumption of beginning day was 66.04 mg $O_2/kg/hr$, and after 28 days of stress decreased by 76.5%. Ammonia nitrogen excretion showed a similar pattern to that of oxygen consumption. Ammonia nitrogen excretion of beginning of the experiment was 0.537 mg N/kg/hr, and after 28 days of stress decreased by 75.4% for LST, and by 74.3% for the middle ones. From in this study it was showed that the physiological activity was reduced by 50% following 8.4 days of vibration stress for LST, and 15.5 days for MST.

Structural and Piezoelectric Properties of MnO2-Doped PZT-PSN Ceramics for Ultrasonic Vibrator (초음파 진동자용 MnO2가 Doping된 PZT-PSN 세라믹스의 구조 및 압전 특성)

  • Cha, Yoo-Jeong;Kim, Chang-Il;Kim, Kyoung-Jun;Jeong, Young-Hun;Lee, Young-Jin;Lee, Hai-Gun;Paik, Jong-Hoo
    • Korean Journal of Materials Research
    • /
    • v.19 no.4
    • /
    • pp.198-202
    • /
    • 2009
  • For use in ultrasonic actuators, we investigated the structural and piezoelectric properties of $(1\;-\;x)Pb(Zr_{0.515}Ti_{0.485})O_3$ - $xPb(Sb_{1/2}Nb_{1/2})O_3$ + 0.5 wt% $MnO_2$ [(1 - x)PZT - xPSN + $MnO_2$] ceramics with a variation of x (x = 0.02, 0.04, 0.06, 0.08). All the ceramics, which were sintered at $1250^{\circ}C$ for 2 h, showed a typical perovskite structure, implying that they were well synthesized. A homogeneous micro structure was also developed for the specimens, and their average grain size was slightly decreased to $1.3{\mu}m$ by increasing x to 0.8. Moreover, a second phase with a pyrochlore structure appeared when x was above 0.06, which resulted in the deterioration of their piezoelectric properties. However, the 0.96PZT-0.04PSN+$MnO_2$ ceramics, which corresponds with a morphotropic phase boundary (MPB) composition in the (1 - x)PZT - xPSN + $MnO_2$ system, exhibited good piezoelectric properties: a piezoelectric constant ($d_{33}$) of 325 pC/N, an electromechanical coupling factor ($k_p$) of 70.8%, and a mechanical quality factor ($Q_m$) of 1779. The specimens with a relatively high curie temperature ($T_c$) of $305^{\circ}C$ also showed a significantly high dielectric constant (${\varepsilon}_r$) value of 1109. Therefore, the 0.96PZT - 0.04PSN + $MnO_2$ ceramics are suitable for use in ultrasonic vibrators.

The Fabrication and Characteristics of Small Disk-Type Ultrasonic Motor (소형 원판형 초음파 모터의 시작 및 특성)

  • Park, C.H.;Lee, J.S.;Jeong, S.H.;Chai, H.I.;Lee, K.W.;Kim, H.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1720-1722
    • /
    • 1999
  • In this paper, we studied the properties of small-size disk-type ultrasonic motor using travelling wave for the application to the precise control robotic joint motor and fabricated it. The diameter of the ultrasonic motor fabricated was 13mm. Also, the piezoelectric vibrator was constructed by piezoelectric ceramic and elastic material. The piezoelectric ceramic was composed to PZ-PT-PMN which was shown the high electromechanical stability under high vibration level and stainless steel was used as the elastic material in which configuration was disk-type. To conform the capability of application to robotic motor, we measured the change of rotational speed according to applied voltage and applied frequency. As the results, the small-size disk-type ultrasonic motor was able to fabricate, and the revolution speed was 350 [rpm] when input voltage was 55 [Vrms] and applied frequency 160.4 [kHz] under pre-load.

  • PDF

Development of a Lateral Mode Piezoelectric Oscillator Sensor to Detect Damages in a Structure (구조물 손상 탐지를 위한 경 방향 모드 압전 오실레이터 센서 개발)

  • Roh, Yong-Rae;Kim, Dong-Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.125-132
    • /
    • 2006
  • This paper presents the feasibility of a lateral mode piezoelectric oscillator to detect damages in civil infrastructures. The lateral mode oscillator sensor is composed of an electronic feedback oscillator circuit and a piezoelectric lateral mode vibrator to be attached to a structure of interest. Damage to the structure causes a change in the impedance spectrum of the structure, which results in a corresponding change of a resonant frequency of the structure. The oscillator sensors can instantly detect the frequency change in a very simple manner. Feasibility of the piezoelectric oscillator sensor was verified in this work with a sample aluminum plate where artificial cracks of different lengths and number were imposed in sequence. Validity of the measurement was confirmed through comparison of the experimental data with the results of finite element analyses of a plate with cracks.