• Title/Summary/Keyword: vibration sensitive equipment

Search Result 44, Processing Time 0.023 seconds

Transportation of KSLV-I FM unit 2 VEB Assembly (KSLV-I 발사2호기 VEB 조합체 이송)

  • Choi, Sang-Hyeon;Park, Jong-Chan;Won, You-Jin;Lee, Soo-Jin;Chung, Eui-Seung
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.20-29
    • /
    • 2011
  • There are a lot of electrical and electronic components and pneumatic parts sensitive to vibration and shock in the VEB assembly which KARI directly transports among the KSLV-I upper stage transportation items. So, the special attention in the transportation is required. The transportation container with the apparatus for controlling environment was made in order to meet the requirements. The transportation tests using the engineering model were performed 4 times to verify the performance of the transportation container and to conform the transportation conditions(transportation velocity, route, etc.). In this document, the previous transportation history of the VEB assembly, the overview and the result of the KSLV-I FM unit 2 VEB assembly transportation are described.

Seismic isolation performance sensitivity to potential deviations from design values

  • Alhan, Cenk;Hisman, Kemal
    • Smart Structures and Systems
    • /
    • v.18 no.2
    • /
    • pp.293-315
    • /
    • 2016
  • Seismic isolation is often used in protecting mission-critical structures including hospitals, data centers, telecommunication buildings, etc. Such structures typically house vibration-sensitive equipment which has to provide continued service but may fail in case sustained accelerations during earthquakes exceed threshold limit values. Thus, peak floor acceleration is one of the two main parameters that control the design of such structures while the other one is peak base displacement since the overall safety of the structure depends on the safety of the isolation system. And in case peak base displacement exceeds the design base displacement during an earthquake, rupture and/or buckling of isolators as well as bumping against stops around the seismic gap may occur. Therefore, obtaining accurate peak floor accelerations and peak base displacement is vital. However, although nominal design values for isolation system and superstructure parameters are calculated in order to meet target peak design base displacement and peak floor accelerations, their actual values may potentially deviate from these nominal design values. In this study, the sensitivity of the seismic performance of structures equipped with linear and nonlinear seismic isolation systems to the aforementioned potential deviations is assessed in the context of a benchmark shear building under different earthquake records with near-fault and far-fault characteristics. The results put forth the degree of sensitivity of peak top floor acceleration and peak base displacement to superstructure parameters including mass, stiffness, and damping and isolation system parameters including stiffness, damping, yield strength, yield displacement, and post-yield to pre-yield stiffness ratio.

A Study on HVDC Underwater Cable Monitoring Technology Based on Distributed Fiber Optic Acoustic Sensors (분포형 광섬유 음향 센서 기반 HVDC 해저케이블 모니터링 기술 연구)

  • Youngkuk Choi;Hyoyoung Jung;Huioon Kim;Myoung Jin Kim;Hee-Woon Kang;Young Ho Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.199-206
    • /
    • 2023
  • This study presents a novel monitoring technique for underwater high-voltage direct current (HVDC) cables based on the Distributed Acoustic Sensor (DAS). The proposed technique utilizes vibration and acoustic signals generated on HVDC cables to monitor their condition and detect events such as earthquakes, shipments, tidal currents, and construction activities. To implement the monitoring system, a DAS based on phase-sensitive optical time-domain reflectometry (Φ-OTDR) system was designed, fabricated, and validated for performance. For the HVDC cable monitoring experiments, a testbed was constructed on land, mimicking the cable burial method and protective equipment used underwater. Defined various scenarios that could cause cable damage and conducted experiments accordingly. The developed DAS system achieved a maximum measurement distance of 50 km, a distance measurement interval of 2 m, and a measurement repetition rate of 1 kHz. Extensive experiments conducted on HVDC cables and protective facilities demonstrated the practical potential of the DAS system for monitoring underwater and underground areas.

Vibration Analysis of Network Communication Equipment (네트워크 통신장비의 진동 해석)

  • Lee, Jae-Hwan;Kim, Young-Joong;Kim, Jin-Sup
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.463-468
    • /
    • 2007
  • Some network equipments made in Korea were exposed to severe earthquake in Japan several years ago. More than a hundred slim base transfer network stations had been seized with the severe earthquake at Nigata and it was reported that less than fifteen sets showed blackout by interruption of electricity, not by the structural failure. The purpose of this paper is to check the structural safety of the network equipments by performing table test, and the static and dynamic finite element analysis. For the dynamic test, the station weighing 200 kg was subjected to the Zone 3 earthquake loading of GR-63-CORE on the shaking table to obtain the dynamic responses to compare with the analysis results. It is shown that the FE analysis results are a little bit larger than that of the experimental values. And the sensitivity analysis and optimization for the natural frequency is performed and it is found that the first natural frequency is sensitive to small design change as shown in the results. And the dynamic response of optimized design is less than the original design.