• 제목/요약/키워드: vibration measuring device

검색결과 52건 처리시간 0.024초

연속주조기 Mold Oscillation 진단시스템 개발 (Development of Diagnostic System for Mold Oscillation in a Continuous Slab Casting Machine)

  • 이성진;전형일;이경순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.387-392
    • /
    • 2002
  • A portable mould oscillation analyzer with an integrated computer, developed by POSCO, records the movement of the mould in every spatial direction. The system uses the gap sensors to measure the mould movement (displacement) in two horizontal directions according to the mould narrow and broad faces and the vertical strokes in the four corners of mould. The gap sensor is a non-contacting minute displacement-measuring device using the principle of high frequency eddy current loss. The mould oscillation diagnostic system integrates the gap sensors, their converters and the industrial portable computer with plug-in data acquisition boards. In an own expert module, which is included in the diagnosis program, one can obtain much information about the mould oscillation equipment.

  • PDF

차대 동력계에서 자동차 구속조건에 따른 거동 특성 비교 (Vehicle dynamic behavior comparison between two different constraining methods on a chassis dynamometer)

  • 강연준;김희수;;민동우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.1000-1003
    • /
    • 2014
  • The primary purpose of this study is to observe the dynamic behavior within a vehicle on chassis dynamometer throughout cleat impact testing with two different constraining setups (Tie-down strap and one point fixation). Throughout this empirical experiment, no outstanding dynamic behavior characteristics are observed between two setups and thus, the performance of the one point fixation device is validated. Neither the interior noise nor acceleration at driver seat rail and knuckle is heavily influenced by two different constraining methods. However, one point fixation is far more advantageous considering its shorter set up time and its capability of measuring traction force with its built in force sensor.

  • PDF

BLDC 모터의 온도 및 진동 특성 연구 (Study on Temperature and Vibration of BLDC Motor)

  • 예정우;손문규;최명환;김대화;조연수;이현석;심재술
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.43-51
    • /
    • 2014
  • In this paper, transient temperature and vibration characteristics of a brushless DC (BLD(c) motor are studied for external load (165W~495W) and rotational speed (2000 rpm~4000 rpm). For experiment, a simple measurement system is developed to allow a change in load and speed for measuring transient temperature and vibration simultaneously. Temperature and vibration were also measured under the conditions of natural convection and forced convection. Vibrations in the directions of x-axis (#Ch1), y -axis (#Ch2) and z -axis (#Ch3) were obtained by three accelerometers and temperature was obtained by a thermo-couple with respect to time until the motor is steady. Experimental results show that the amplitude of vibration is higher in the order of z-axis (#Ch3), x -axis (#Ch1) and y-axis (#Ch2) and the amplitude of vibration at the forced convection conditions is 10.6% to 17.8% lower than that of vibration at the natural convection. However, the ratio of the vibration value is similar on average regardless of external convection condition.

회전기기 실시간 동작상태 모니터링을 위한 자가발전 기반 센서모듈 (Self-Powered Integrated Sensor Module for Monitoring the Real-Time Operation of Rotating Devices)

  • 김창일;여서영;박범근;정영훈;백종후
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.311-317
    • /
    • 2019
  • Rotating devices are commonly installed in power plants and factories. This study proposes a self-powered sensor node that is powered by converting the vibration energy of a rotating device into electrical energy. The self-powered sensor consists of a piezoelectric harvester for self-power generation, a rectifier circuit to rectify the AC signal, a sensor unit for measuring the vibration frequency, and a circuit to control the light emitting diode (LED) lighting. The frequency of the vibration source was measured using a piezoelectric-cantilever-type vibration frequency sensor. A green LED was illuminated when the measured frequency was within the normal range. The power generated by the piezoelectric harvester was determined, and the LED operation was assessed in terms of the vibration frequency. The piezoelectric harvester was found to generate a power of 3.061 mW or greater at a vibration acceleration of 1.2 g ($1g=9.8m/s^2$) and vibration frequencies between 117 and 123 Hz. Notably, the power generated was 4.099 mW at 122 Hz. As such, our self-powered sensor node can be used as a module for monitoring rotating devices, because it can convert vibration energy into electrical energy when installed on rotating devices such as air compressors.

발전소 회전기기 정밀진단을 위한 휴대용 진동분석기 개발 (Development of a Portable Vibration Analyzer for Precision Diagnosis of Plant's Rotating Equipment)

  • 노형호;유호선
    • 플랜트 저널
    • /
    • 제17권4호
    • /
    • pp.53-60
    • /
    • 2021
  • 본 연구에서는 국내 진동감시시스템 제작업체인 (주)나다와 발전소 회전기기 진동데이터 취득 및 분석에 효과적인 휴대용 진동분석기를 개발하고자 하였다. 개발된 휴대용 진동분석기의 하드웨어는 측정기기의 교정을 위한 측정 불확도를 통해 얻은 측정값을 시스템에서 보정함으로써 측정오차를 최소화하였고, 고속 데이터 처리로 높은 분해능을 가진 신호처리 장치로 구성되었다. 소프트웨어 구조는 다양한 진동 플롯을 구현하여 상세한 분석프로그램을 실행하며, 회전기기 운전 중 외란으로 발생하는 노이즈 측정 및 제거에 효과적인 알고리즘을 적용하였다. 개발품은 사용자의 이동 편의성 증대 및 고속 데이터 처리로 분해능을 높임으로써 성능향상은 물론, 국산화 개발에 따른 구입비용 절감에도 크게 기여하였다.

Measurements of pedestrian's ioad using smartphones

  • Pan, Ziye;Chen, Jun
    • Structural Engineering and Mechanics
    • /
    • 제63권6호
    • /
    • pp.771-777
    • /
    • 2017
  • The applications of smartphones or other portable smart devices have dramatically changed people's lifestyle. Researchers have been investigating useage of smartphones for structural health monitoring, earthquake monitoring, vibration measurement and human posture recognition. Their results indicate a great potential of smartphones for measuring pedestrian-induced loads like walking, jumping and bouncing. Smartphone can catch the device's motion trail, which provides with a new method for pedestrain load measurement. Therefore, this study carried out a series of experiments to verify the application of the smartphone for measuring human-induced load. Shaking table tests were first conducted in order to compare the smartphones' measurements with the real input signals in both time and frequency domains. It is found that selected smartphones have a satisfied accuracy when measuring harmonic signals of low frequencies. Then, motion capture technology in conjunction with force plates were adopted in the second-stage experiment. The smartphone is used to record the acceleration of center-of-mass of a person. The human-induced loads are then reconstructed by a biomechanical model. Experimental results demonstrate that the loads measured by smartphone are good for bouncing and jumping, and reasonable for walking.

리니어 엔코더를 이용한 선박 엔진용 무선 크랭크 샤프트 디플렉션 검사 장치 개발 (Development of Wireless Device for Inspecting Crankshaft Deflection Using Linear Encoder)

  • 김장규;이민철
    • 한국정밀공학회지
    • /
    • 제26권5호
    • /
    • pp.104-111
    • /
    • 2009
  • A ship engine operator should compensate the crankshaft assembly of ship engine after inspecting crankshaft deflection error in the crank throw regularly to avoid engine vibration and abrasions. In the previous method, the operator enters the bed plate and measures crankshaft deflection using dial gauge on rotating crankshaft manually. However, this method can cause dangerous situation to the operator as well as uncomfortable in an inferior environment. In order to solve the problems, this paper studies the method which makes the operator measure the error outside of the bed plate. In this paper, it is suggested that BlueTooth wireless communication transfers the error data to the outer standing operator with digitalized crankshaft deflection inspection device developed in this paper. So, the wireless measurement system is developed and applied to a medium-speed marine engine through size-miniaturization. After applying test, the developed inspection device showed that it provides much safe and ease inspection method. Furthermore, in the result, the measuring accuracy is more improved.

F형 다중펄스 로켓모타 적용 펄스분리장치 특성 분석 (Performance Analysis of a Pulse Separation Device for a F-type Multi-Pulse Rocket Motor)

  • 이동원;이원복;김인식;이방업
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.24-27
    • /
    • 2012
  • 본 연구에서는 격벽형 펄스분리장치의 성능을 검증하기 위하여 실물형 Flight-type의 이중펄스 로켓모타 추진기관을 설계, 제작하여 지상연소시험을 수행하였다. 지상연소시험 시 계측한 추진기관의 압력, 추력, 진동 결과를 바탕으로 펄스분리장치의 파열특성인 파열시간과 파열압력 분석을 실시하였고 연소시험 후 3차원 측정기를 이용한 삭마량 측정을 실시하였다. 그 결과, 펄스분리장치가 파열조건 및 열적 안전성을 만족하는 것을 확인할 수 있었다.

  • PDF

사장교 케이블장력 계측장치의 현장적용성 분석 (Field Application Analysis of Cable Tension Measuring Device on Cable-Stayed Bridges)

  • 이현철
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.295-311
    • /
    • 2021
  • 본 연구에서는 사장교 케이블에 대한 장력계측장치의 현장적용성에 대한 실험을 수행하였다. 사장교 케이블의 장력을 추정하기 위해서 진동법을 이용하였으며 대상교량에 대해서 케이블의 가진을 통해서 모드특성을 분석하였고 케이블의 장력을 추정하기 위한 계측장치로는 GTDL360, NI Module, 9 Axes Motion Sensor등을 적용하였고 5개의 대상교량에 대해서 상기 계측장치들을 이용하여 케이블의 모드특성을 분석하여 케이블장력측정실험의 적정성을 평가하고 케이블의 장력을 추정하였다. 또한 5개의 대상교량에 대해서 수치해석을 실시하여 케이블의 고유진동수 및 케이블장력을 해석하였다. 현장 계측결과에 의한 케이블의 추정장력과 수치해석에 의한 케이블의 추정장력을 비교하여 현장계측방법의 적정성을 판단하였으며 분석결과 현장 계측에 의한 케이블의 계측장력과 해석에 의한 추정장력은 오차범위내에 있어서 상기 계측장치들을 현장에 적용하여도 무방할 것으로 판단된다. 현장실증교량의 가속도 기반의 케이블 추정장력과 수치해석에 의한 해석장력과의 값을 비교분석한 결과 값이 허용범위 내로 가속도 기반의 케이블 추정장력값은 적정한 것으로 판단된다. 또한, 현장적용성 분석결과 센서의 설치위치 및 기상조건의 제한 등 계측장치의 한계점이 존재하므로 추후 케이블 스마트 장력계측시스템에 관한 지속적인 후속연구가 필요할 것으로 판단된다.

공용중 도로하부의 굴착터널 해석 및 계측 연구 (An Analytical and Experimental Study on the Mechanical Behavior of Excavating Turnels beneath the Roadway)

  • 정광모;방명석
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.99-104
    • /
    • 2012
  • A turnelling work beneath roadways or railways in use is unsafe and dangerous. A turnelling method should be analytically and experimentally studied to verify stability and safety of excavating works by construction step. The conventionally analytical method was ineffective in computational time and cost, so the new analytical method named homogenuity method, was developed and verified compared with analytical results. That method was applied to parameterly study the effect of distance of steel supports and overburdening height of soil. It showed that the homogenuity method was very practical and effective in step-by-step analysis considering construction sequences. A measuring device was set at the construction field and mechanical behavior was monitored during construction. Measuring values are larger than analytical values because impact of inserting steel pipes, lowering level of underground water and vibration of passing vehicles affected soil density during construction, but those values were within allowable limits.