• 제목/요약/키워드: vibration frequency measurement

검색결과 584건 처리시간 0.033초

3축 가속도 센서 기반의 무선 진동 측정 시스템 (Wireless Vibration Measurement System Using a 3-Axial Accelerometer Sensor)

  • 유주연;박근철;전아영;김철한;김윤진;노정훈;전계록
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.131-136
    • /
    • 2011
  • In this study, a compact wireless vibration measurement system was developed using a 3-axial accelerometer in order to evaluate the vibration stimulation system. A low power microprocessor chip integrated with 2.4 GHz RF transceiver was used for the wireless data communication. To evaluate the system, the frequencies and accelerations from the vibration stimulation system were measured using an LVDT sensor and a vibration measurement system. The average frequency difference by the measurement system was less than 0.1 Hz, and the standard deviation of frequencies estimated by the LVDT sensor and the accelerometer was below 0.08 Hz. The developed system was applied to access a vibration stimulation system for the future study. The average acceleration difference of the central and peripheral point of the stimulation system was less than 0.0005 g(1 g=9.8 $m/s^2$), and the standard deviation of the acceleration was below 0.004 g, which shows the usefulness of the wireless vibration measurement system.

열차하중에 의한 지반 및 인접구조물의 진동 계측과 예측 해석 (Measurement and Prediction Analysis of Ground and Structural Vibration Induced by Train Load)

  • 이주호;박광순;박경래;양신추
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.365-370
    • /
    • 1998
  • In this study, the method of analysis which is developed for calculating dynamic train loads and ground vibration by Shin-Chu Yang is verified comparing measurements of real structure. The results of analysis are agreed well with measurements of ground and structural vibration induced by passing train. The vibration level of analyzed results which is more than that of measured gives conservative result. To analyze frequency characteristics, the analyzed results are applied to the ISO environmental vibration regulation and reveal the possibility of application in analysis of frequency characteristics.

  • PDF

디스크 브레이크에서 열섬 현상이 발생되는 원인과 저더 진동에 미치는 영향 (The Origin and Effect of Hot Spot Phenomena on Judder Vibration in Automotive Disk Brake)

  • 조호준;조종두;김명구;맹주원;이재한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.213-218
    • /
    • 2006
  • Hot spot phenomenon is caused by non-uniform contact area between brake pad and disk frequent braking. Brake disk deformed by locally concentrated heat increases magnitude of frictional vibration. And this deformation can highly influence the judder vibration. In this experimental study, vibration and hot spot was measured in accordance with rotation of disk and pressure of master cylinder for finding the factors that causes hot spot phenomena. For comparing hot spot aspects with mode shapes of disk, mode shapes were measured by conducting modal test, and analyzed by using finite element analysis. Relation between hot spot phenomenon, and mode shape, pressure of master cylinder and rotation speed of disk respectively, was achieved by hot spot measurement and frequency analysis.

  • PDF

디스코 브레이크에서 열섬 현상이 발생되는 원인과 저더진동에 미치는 영향 (The Origin and Effect of Hot Spot Phenomena on Judder Vibration in Automotive Disk Brake)

  • 조종두;김명구;조호준
    • 한국소음진동공학회논문집
    • /
    • 제16권8호
    • /
    • pp.886-892
    • /
    • 2006
  • Hot spot phenomenon is caused by non-uniform contact area between brake pad and disk frequent braking. Brake disk deformed by locally concentrated heat increases magnitude of frictional vibration. And this deformation can highly influence the judder vibration. In this experimental study, vibration and hot spot was measured in accordance with rotation of disk and pressure of master cylinder for finding the factors that causes hot spot phenomena. For comparing hot spot aspects with mode shapes of disk, mode shapes were measured by conducting modal test, and analyzed by using finite element analysis. Relation between hot spot phenomenon, and mode shape, pressure of master cylinder and rotation speed of disk respectively, was achieved by hot spot measurement and frequency analysis.

반사 신호를 이용한 용량 성 센서의 신호처리 및 이를 이용한 초정밀 간극 측정 (Reflective Signal Based Signal Contioning of Capacitive Sensor and High Precision Gap Measurement)

  • 김재근;이택주;임수철;박경수;박노철;박영필;엄원석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.537-537
    • /
    • 2010
  • High precision sensing is very important in various technologies. Especially, it is more important when it were applied to nano/micro meter level's sensing like AFM, storage, etc. And capacitive sensing is widely used method. To improve the measurement efficiency, many signal conditioners were studied and one of them was surface acoustic wave (SAW) device. SAW device is very widely used as a high frequency bandwidth filter. Due to the reflective characteristic of high frequency, the response of SAW device contains both propagative and reflective signal at the external impedance. In this paper, we used SAW device as signal conditioner of capacitive sensor. And high precision gap measurement was executed using capacitive load. Reference signal was reflective SAW response and the magnitude at the center frequency of SAW device by the change of impedance was checked. Finally, the attainable gap resolution was determined.

  • PDF

소음 수응 한계를 고려한 저주파 소음평가에 대한 실험적 연구 (A Laboratory Study on Low Frequency Noise Assessment based on Noise Acceptability Limit)

  • 홍승기;김재환;김규태;이수갑
    • 한국소음진동공학회논문집
    • /
    • 제17권8호
    • /
    • pp.736-740
    • /
    • 2007
  • A laboratory study on low frequency noise assessment has been carried out to evaluate the relevance of the weighting curve. Especially, the A-weighting curve which is used in most noise assessments has been evaluated using the acceptability limit in this study. The acceptability limit is one of the indicators in which the subjective responses were well-reflected. For the measurement of the acceptability limit, pure tone stimuli were used in the frequency range between 20 and 200 Hz. The measurement was proceeded in the anechoic chamber to minimize the background noise level. A total of 29 test subjects, who were aged between 19 to 33 years, participated in this study. They had been exposed to various stimuli for about 1 hour by supra-aural earphone. The measurement consisted of two listening sessions: hearing threshold and the acceptability limit session. The results showed that the tendency of the acceptability limit curve was approximately equal to C-weighting curve which had been found to be superior to A-weighting curve in assessment of low frequencies.

반무한보의 면내 진동인텐시티 측정 (Measurements of In-Plane Vibration Intensity of a Semi-Infinite Beam)

  • 김창렬;길현권;전진숙;홍석윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1185-1188
    • /
    • 2002
  • The objective of this paper is to apply experimental methods to measure the in-plane vibration intensity of a semi-infinite beam. Two experimental methods have been implemented to measure the in-plane vibration intensity of the beam. The first method is the cross spectral intensity measurement method using two accelerometers. The second method is the frequency response method using the only one acrelerometer. It has the advantages of shortening measurement time and reducing accelerometer phase error. Experimental results showed that those experimental methods can be effectively used to measure the structural In-plane vibration intensity.

  • PDF

소형 경량판넬을 이용한 차음성능 영향요인별 음향감쇠계수 분석 (Characteristics of Sound Reduction Index through Small Sized Lightweight Panel)

  • 양홍석;김명준;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.138-147
    • /
    • 2007
  • Recently, framed structure is increasingly being used as apartment structure due to the advantages during remodeling. Therefore, the use of lightweight panel as separating wall is increasing. To construct lightweight panel structures with sound insulation performance appropriate to the conditions of each field, measurement of sound reduction index(SRI) through panel structures should be performed. In this study, measurement of SRI through 46 kinds of panel structures was performed in the condition of various factors such as surface density, air space and absorber. The result showed that SRI of panel structures was generally higher by increasing of surface density. In the case of double panel with no absorber, SRI at below critical frequency was gradually increased according to rise of air space. Double panel with absorber make remarkable improvement in SRI at low frequency, but there is a little difference compared with SRI of double panel with no absorber over critical frequency.

  • PDF

쉘타입 로울러 게이트의 회피개도량 산정 방법 (A Method on Estimation of Avoiding Open Range on Shell-type Roller Gate)

  • 정지승;정해욱
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.85-91
    • /
    • 2017
  • When the shell-type roller gate is partly open, at a certain height the large vibration is caused due to resonance and the vibration can cause damage to the gate. In this study, the review on amplitude of vibration and the possible resonance occurring at the time of opening or closing of gate is performed. Throughout the natural frequency analysis, the installation location of the measuring instrument was selected. On opening or closing of gate, the measurement of gate vibration is performed. The natural frequencies according to the opening range of the gate is analyzed. As a result of measurement and analysis, we proposed ranges in which vibration occurs largely and resonance is predicted as an avoiding open ranges, or the safe opening or closing of the shell-type roller gate. The application of this paper's avoiding open range estimation method of shell-type roller gate can be utilized as the basic data for the systematic and rational maintenance management of dams and submerged weirs in the future, and it is expected that this study can bring forth.

Performance of Different Sensors for Monitoring of the Vibration Generated during Thermosonic Non-destructive Testing

  • Kang, Bu-Byoung
    • 비파괴검사학회지
    • /
    • 제31권2호
    • /
    • pp.111-117
    • /
    • 2011
  • Vibration monitoring is required for reliable thermosonic testing to decide whether sufficient vibration is achieved in each test for the detection of cracks. From a practical point of view, a cheaper and convenient monitoring method is better for the application to real tests. Therefore, the performance of different sensors for vibration monitoring was investigated and compared in this study to find a convenient and acceptable measurement method for thermosonics. Velocity measured by a laser vibrometer and strain provide an equivalent HI when measured at the same position. The microphone can provide a cheaper vibration monitoring device than the laser and the heating index calculated by a microphone signal shows similar characteristics to that calculated from velocity measured by the laser vibrometer. The microphone frequency response shows that it underestimates high frequency components but it is applicable to practical tests because it gives a conservative value of HI.