Regional Control of Vibration (진동의 영역 제어)

  • Kim, Yang-Hann;Chang, Ji-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.472-475
    • /
    • 2008
  • Generally, a linear vibration theory regards a vibratory system as the superposition of many degrees of vibratory system. Modal analysis stems, in fact, considers the vibration system as what has input, output, and transfer function that relates the input and output. When we want to control, however, the vibratory system, we define, first, the object function that can be vibration energy of certain vibratory system. Then, we try to find the transfer function that can minimize the object function. We can readily extend this approach to control the distributed vibration system. For example, the vibrations of a vehicle, including ships and trains. In this case, we may want to minimize the vibration of the area we select. For example, minimize the vibration of the passengers' seat, but allowing the vibration of other area; for example engines and wheels. This paper introduces a general theory that can control the vibration of the selected area, which can be called as "regional control of vibration." In fact, this is the extended theory of well known sound control of "bright zone"(Choi and Kim, 2002).]. Several illustrative examples demonstrate the applicability and properties that are not available if we use modal analysis method.

  • PDF

Active Vibration Control of Smart Hull Structure in Underwater Using Micro-Fiber Composite Actuators (MFC 작동기를 이용한 수중 Hull 구조물의 능동 진동 제어)

  • Kwon, Oh-Cheol;Sohn, Jung-Woo;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.466-471
    • /
    • 2008
  • Structural vibration and noise are hot issues in underwater vehicles such as submarines for their survivability. Therefore, active vibration and noise control of submarine, which can be modeled as hull structure, have been conducted by the use of piezoelectric materials. Traditional piezoelectric materials are too brittle and not suitable to curved geometry such as hull structures. Therefore, advanced anisotropic piezoceramic actuator named as Macro-Fiber Composite (MFC), which can provide great flexibility, large induced strain and directional actuating force is adopted for this research. In this study, dynamic model of the smart hull structure is established and active vibration control performance of the smart hull structure is evaluated using optimally placed MFC. Actuating performance of MFC is evaluated by finite element analysis and dynamic modeling of the smart hull structure is derived by finite element method considering underwater condition. In order to suppress the vibration of hull structure, Linear-Quadratic-Gaussian (LQG) algorithm is adopted. After then active vibration control performance of the proposed smart hull structure is evaluated with computer simulation and experimental investigation in underwater. Structural vibration of the hull structure is decreased effectively by applying proper control voltages to the MFC actuators.

  • PDF

Active Vibration Control of Underwater Hull Structure Using Macro-Fiber Composite Actuators (MFC 작동기를 이용한 수중 Hull 구조물의 능동 진동 제어)

  • Kwon, Oh-Cheol;Sohn, Jung-Woo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.138-145
    • /
    • 2009
  • Structural vibration and noise are hot issues in underwater vehicles such as submarines for their survivability. Therefore, active vibration and noise control of submarine, which can be modeled as hull structure, have been conducted by the use of piezoelectric materials. Traditional piezoelectric materials are too brittle and not suitable to curved geometry such as hull structures. Therefore, advanced anisotropic piezocomposite actuator named as Macro-Fiber Composite(MFC), which can provide great flexibility, large induced strain and directional actuating force is adopted for this research. In this study, dynamic model of the smart hull structure is established and active vibration control performance of the smart hull structure is evaluated using optimally placed MFC. Actuating performance of MFC is evaluated by finite element analysis and dynamic modeling of the smart hull structure is derived by finite element method considering underwater condition. In order to suppress the vibration of hull structure, Linear Quadratic Gaussian(LQG) algorithm is adopted. After then active vibration control performance of the proposed smart hull structure is evaluated with computer simulation and experimental investigation in underwater. Structural vibration of the hull structure is decreased effectively by applying proper control voltages to the MFC actuators.

A Study on the noise & vibration properities of Fan Filter Unit and evaluation of effect to Clean Room (Fan Filter Unit 소음ㆍ진동 특성과 청정실에 미치는 영향성 평가에 관한 연구)

  • 백재호;손성완
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.778-784
    • /
    • 2002
  • FFU are used increasingly by the microeleceronics industry to provide clean recirculating air for the fabrication of integrated circuits and laminar flow air. There may be several hundred ffu in a large cleanroom, covering 100% of the ceiling area. Hence, there is of often knowledge in the inside and outside of the country the flu give rise to noise & vibration trouble to microelectronics industry. Noise & Vibration control for satisfication about noise & vibration criteria in TFT-LCD factory cleanroom be in need of exact noise & vibration data of accurence from utility & equipment that can be exert a bad influence upon cleanroom. In this pater, hence we found out noise and vibration properities of ffu by using experimental method. And, we performed noise & vibration analysis about noise it vibration level in cleanroom using semiempirical method for quantative approach about noise & vibration level in cleanroom.

  • PDF

Recent Developments in Underwater Noise Control Technology (수중 소음제어 기술의 최근 연구동향)

  • Ohm, Won-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.381-381
    • /
    • 2012
  • Noise control in underwater environments is an entirely different beast from its airborne counterpart, partly because of the orders-of-magnitude difference in density and compressibility between water and air. One of the most popular systems ever used for (passive) noise reduction under water is an anechoic coating known as "alberich," which was developed by the German during the Second World War and are still used today in naval applications. This talk looks back on some recent developments in underwater noise control, ranging from acoustic metamaterials to active noise control techniques, specifically geared to achieving underwater invisibility.

  • PDF

Idle Quality Optimization Study (공회전시 차량의 소음진동현상의 질적개선에 대한 고찰)

  • ;Norbert Wiehagen
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.342-352
    • /
    • 2003
  • Idle NVH characteristics are one of the most important aspects among the vehicle performances. Vehicle developers are devoted to improve vehicle interior noise and steering wheel and seat vibrations. In order to improve the idle quality, noise and vibration transfer path should be carefully evaluated. Also, effects of various components related to the idle performance should be confirmed. A general procedure for improving the idle qualify is described in detail. The relationship among cylinder pressure characteristics, crankshaft rotational speed variation, and vehicle vibrations is also investigated. Influences of drive shaft, torque converter, air conditioning system, vehicle structure including engine mount system, and idle control parameters on the vehicle idle quality are studied. Weak points of typical vehicles on the idle qualify are identified. Some of improvement measures are proposed and verified.

  • PDF

Vibration Sensing and Control of a Plate Using Optical Fiber Sensor (광섬유 센서를 이용한 평판의 진동 감지 및 제어)

  • Kim, Do-Hyung;Han, Jae-Hung;Yang, Seung-Man;Kim, Dae-Hyun;Lee, In;Kim, Chun-Gon;Hong, Chang-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.459-464
    • /
    • 2001
  • Vibration control of a plate using an optical fiber sensor and a PZT actuator is considered in this study. An aluminum plate with attached Extrinsic Fabry-Perot Interferometer (EFPI) and PZT actuator is prepared for experimental investigation. Vibration level of EFPI that can represent the mechanical strain without severe distortion is validated by forced vibration experiment. A numerical model of the plate is constructed based on the experimentally obtained frequency responses, and an optimal controller is designed for the multi-modal vibration suppression. It is found that the vibration level of the first three modes can be greatly reduced. The effect of low-pass filtering used to eliminate high frequency noise on the stability and control performance is also considered.

  • PDF

Active Vibration Control of Flexible Plate using Piezo Ceramic (피에조 세라믹을 이용한 유연한 평판의 능동진동제어)

  • 박수홍;김홍섭;홍진석;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.434-439
    • /
    • 1997
  • This paper presents the active control of a flexible plate vibration. The plate was excited by white noise point force and the control was performed by one or two piezo ceramic actuator bonded to the surface of the plate. An adaptive controller based on filtered-x or multiple filtered-x LMS algorithm was used and the controller was defined by minimizing the square of the response of error sensor. In the experiment, PZT sensor was used as an error sensor while white noise was applied as a disturbance. In the case of multiple channel control, more than 22 dB of vibration reduction was achieved. Results indicate that the vibration of a flexible plate could be controlled effectively when the piezo ceramic actuator was used with multiple filtered-x LMS algorithm.

  • PDF

Research on the Elevator-operating Noise and Vibration in Apartment Buildings (공동주택 승강기 운행소음ㆍ진동 실태 및 저감설계)

  • 김명준;김하근;김흥식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.488-493
    • /
    • 2001
  • In accordance with the tendance to construct high-rise apartment buildings, the transporting elevators tend to speed up to 90-105m/min and to drive more frequently. So, the problem of noise produced by the elevator operation has been treated as an important subject. In this research, the actual conditions of noise and vibration which generated and transmitted by the elevator operation in apartment buildings were measured and analysed. And the several noise and vibration control design which helps reduce noise were examined.

  • PDF