• 제목/요약/키워드: vibration Criteria

검색결과 412건 처리시간 0.021초

수직진동에 대한 사용성을 고려한 경계조건에 따른 2방향 슬래브 최소두께 제안 (Proposing the Thickness of 2-Way Slab Satisfying Floor Vibration Criteria for Several Boundary Condition)

  • 김동현;이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.199-202
    • /
    • 2005
  • KCI 2003 provides minimum thickness of slab that satisfies serviceability to static displacement. Previous study (Han, et al. 2003) showed the several slabs that designed according to minimum thickness criteria had floor vibration problem. In this study, evaluate the floor vibration serviceability of KCI 2003 minimum thickness requirements for 2-way flat plate and propose the minimum thicknesses of 2-way slabs that satisfy floor vibration criteria according to several boundary condition. For this purpose, one degree of freedom model is used and Monte Carlo simulation is performed.

  • PDF

인체모델을 사용한 승차감의 정량적 평가에 관한 연구 (A Study on the Evaluation of Ride Comfort using Human Model)

  • 김광석
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.57-64
    • /
    • 2011
  • Vibrations on the floor in a car are transmitted to the foot, hip, and back from the seat. Human body recognizes these vibrations, but the sensitivity for each vibration is different. To evaluate these vibrations, RMS(root mean square) of accelerations, VDV(vibration does value) are commonly used. The ride comfort evaluation is usually carried out by experiments of real cars which are expensive. The purpose of this paper is to briefly review the status of several ride vibration standards and criteria having relevance to construction machinery vehicles and to suggest recommendations for the effective use of such criteria in vehicle / component development.

수치해석을 이용한 이중보온관 발파진동 관리기준에 관한 연구 (A Study on Blasting Vibration Control Criteria for Pre-insulated Pipe through the Numerical Analysis)

  • 최봉혁;조진우;김진만;유한규
    • 대한토목학회논문집
    • /
    • 제33권4호
    • /
    • pp.1471-1478
    • /
    • 2013
  • 본 논문에서는 이중보온관의 발파진동 관리기준 제시를 위하여 이격거리와 매설심도를 변수로하여 수치해석을 수행하였다. 수치해석 적용 발파하중 모델은 현장시험 결과와의 비교를 통하여 검증하였다. 수치해석 결과, 이중보온관은 진동속도 4.0cm/sec 이상에서 발생 유효응력이 내관의 허용응력을 초과하거나 근접하는 것으로 나타났으며, 4.0cm/sec 이하에서 안정성이 확보되는 것으로 평가되었다. 따라서, 이중보온관의 진동관리기준은 4.0cm/sec를 초과하지 않도록 관리하여야 할 것으로 판단된다.

Free Spanning of Offshore Pipelines by DNV

  • CHOI HAN SUK
    • 한국해양공학회지
    • /
    • 제19권2호
    • /
    • pp.47-52
    • /
    • 2005
  • This paper introduces a procedure for free span and fatigue analysis of offshore pipelines per DNV-RP-F105, 2002. The new method includes the axial force and deflection load in pipelines. The screening criteria were established to calculate the allowable span lengths in the new design codes. The screening criteria allows a certain amount of vortex-induced vibration due to wave and current loading. However, the induced pipe stresses are very small and usually below the limit stresess of typical S-N curves. In contrast, the conventional criteria did not allow any vortex-induced vibration in the free span of pipelines. Thus, the screening criteria yields reduced allowable span lengths. A simplified procedure was established to calculate the fatigue damage due to long-term current distribution. The long-term current statistics was assumed with a 3-parameter Weibull distribution. The fatigue damage was estimated for the span lengths obtained from the screening criteria for various conditions. Sample calculations show the effect of axial force for various boundary conditions. Comparisons with conventional criteria are included.

복합상가건물 영화관 영사실의 진동허용 규제치 결정 및 저감 대책 (A Study on the Determination of Vibration Criteria and Vibration Reduction at Projection Room Floor in a Complex Building)

  • 박해동;김강부;백재호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.671-675
    • /
    • 2002
  • 영화관의 구조설계에서 중요한 고려 인자 중에서 음향적 관점뿐만 아니라, 영사기의 진동으로 인한 영상의 떨림 현상은 관람석에서 미치는 구조물의 동적 특성 문제에 있다. 이는 영사기-스크린-관람객 사이의 3인자에 내한 상대진동허용변위에 의해 지배됨을 고려하여, 이를 만족시키는 변수 등에 따른 진동허용규재치를 결정하는 절차가 필요하다. 본 연구에서는 영화관의 진동허용규제치를 이들 3인자에 대한 변수들을 고려한 결정 과정을 공학적인 차원에서 정리하였으며, 복합상가 건물내의 영화관 영사실에 이를 만족하기 위한 진동 저감설계 자료에 활용하였다.

  • PDF

KSR-III 로켓의 도로운송 및 핸들링에 의한 진동하중 (Vibration Loads on KSR-III during Ground Transportation and Handling)

  • 전영두;조병규;박동수;황승현;김준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.250-254
    • /
    • 2002
  • It is conducted to analyze vibration loads on KSR-III(KSR: Korea Sounding Rocket) and its major segments during their ground transportation and various handling process. These loads may be different from the real flight environment. Inadequate assessment of these loads can cause not only local damages on the rocket system but also the critical problem like flight mission failure. Therefore, transportation and handling loads must be considered during design and attenuated to ensure that the rocket structural damage does not occur. This work is concerned with the generation of criteria and prediction of transportation and handling loads for KSR-III. The results show that the shipping container is well designed to satisfy the design requirements. The maximum vibration level recorded during whole transportation and handling for KSR-III is less than 2g, the criteria of KSR-III movement condition.

  • PDF

APR1400 원자로내부구조물 종합진동평가 측정위치 선정 기준 (Selection Criteria of Measurement Locations for Advanced Power Reactor 1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program)

  • 고도영;김규형;김성환
    • 한국소음진동공학회논문집
    • /
    • 제21권8호
    • /
    • pp.708-713
    • /
    • 2011
  • U.S. nuclear regulatory commission(NRC) regulatory guide(RG) 1.20 requires a comprehensive vibration assessment program(CVAP) for use in verifying the structural integrity of reactor vessel internals(RVI) for flow-induced vibrations prior to commercial operation. The CVAP program consist of vibration and fatigue analysis, a vibration measurement program, an inspection program, and a correlation of their results. One of the main purposes of the analysis program is to select measurement locations, however measurement locations can not be determined by only analysis results, therefore we developed selection criteria of measurement locations for advanced power reactor 1400(APR1400) RVI CVAP, It will be used to select measurement locations and instrument types for APR1400 RVI CVAP.

고정밀장비의 진동허용규제치 사양에 관한 연구 (A Study on the Specification of Vibration Criteria of Sensitive Equipment)

  • 이홍기;박해동;김두훈;김사수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.362-369
    • /
    • 1997
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria of high sensitive equipment should be expressed in the form of 'exactness' and 'accuracy', because this is made basic data in the use of building structure design. This paper made a study on the specification of high sensitive equipment and proposed a contents of the specification.

  • PDF

초고층 건축물의 수평진동에 대한 인지도 평가 (Perception Threshold for Horizontal Vibration of Tall Buildings)

  • 조강표;정승환;조수연
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.751-756
    • /
    • 2007
  • In this paper, perception threshold for horizontal vibration of tall buildings was investigated. After a comparative study of human comfort criteria for wind-induced vibration in foreign countries being made, perception threshold was recorded by increasing acceleration in the range of 0.2Hz through 1.2Hz of frequency in horizontal vibration experiments, and perception of subjects was examined by a proper questionnaire. Also, the results obtained from experiments of horizontal vibration were compared with Japanese standard(AIJES-A001-2004).

  • PDF

원자 현미경 장비의 바닥 진동(정상 상태) 허용 기준 결정 (Determination of the Allowable Vibration Level of the Atomic Force Microscope Equipment)

  • 이동연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.161-164
    • /
    • 2000
  • Currently, Atomic Force Microscope(AFM) has been widely used to measure the surface topography of a sample by detecting interaction force between atoms on the sample and extremely sharp probe tip. The vertical resolution of AFM is mainly determined by external vibration noise. The resolution of AFM shows different values for the different environment, thus it is necessary to determine relationship between the criteria and the resolution of AFM regardless of environment. In this paper, we discuss the allowable level of floor vibration for AFM equipment at given resolution. The vibration criteria can be used as reference data to design mechanical structure and to analyze the structural dynamics of AFM equipment.

  • PDF