• 제목/요약/키워드: vibration Criteria

검색결과 412건 처리시간 0.019초

APR1400 원자로내부구조물 종합진동평가 응답측정시험 허용기준 수립 (Establishment of Response Instrumentation Test Acceptance Criteria for APR1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program)

  • 고도영;김규형;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.212-218
    • /
    • 2011
  • APR1400 RVI CVAP using the non-prototype category is being conducted to verify integrity of the RVI design and to secure the CVAP technology. The measurement programs are to confirm vibration analysis results for reactor internals during preoperational and initial startup testing and to detemine the safety margin. One of the important basis for the measurement programs is test acceptance criteria. Therefore, this paper is on establishment of response instrumentation test acceptance criteria for APR1400 RVI CVAP. The established acceptance criteria show that the stress criteria of APR1400 RVI are more conservative values than those of the valid prototype plant(Palo Verde unit 1) and, the displacement criteria of the IBA and the UGS were established to 0.03 in and 0.01 in, respectively.

  • PDF

원전 터빈 발전기 비틀림 진동기준 국제표준규격(ISO 22266-1) 적용 사례 (Application Case of ISO 22266-1 for Establishing the Torsional Vibration Criteria of a Nuclear Turbine Generator)

  • 정혁진;송우석;이혁순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.225-226
    • /
    • 2010
  • ISO 22266-1 issued in May 2009 provides guidelines for applying shaft torsional vibration criteria, under normal operating conditions, for the coupled shaft system and long blades of a turbine generator set. In case that a turbine generator vendor do not meet the separation margin of torsional natural frequencies in the technical specifications of the purchaser, this standard can present the reasonable and objective criteria about torsional vibration which both purchaser and supplier can agree on, while ensuring the integrity of turbine generator. This paper describes the application case of ISO 22266-1 for the establishment of torsinal vibration criteria under retrofitting the turbine generator of 'U' nuclear power plant.

  • PDF

주파수 응답함수를 이용한 고정밀 장비의 진동허용규제치 결정기법에 관한 연구 (A Study on the Vibration Criteria Decision for High Technology Facilities using FRF)

  • 이홍기;김두훈;김사수
    • 소음진동
    • /
    • 제6권3호
    • /
    • pp.363-373
    • /
    • 1996
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in promotion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. The former is accurate but requires a great deal of time and efforts while the latter lacks reliability. This paper proposes a new method to solve this problem at a time. The permissible vibration level to a precision equipment can be easily obtained by analyzing the process of Frequency Response Function(FRF). This paper also demonstrates its effectiveness by applying the proposed method to finding the permissible vibration criteria of a Computer Hard Disk Drive.

  • PDF

흥인지문 인접 CIP공사시 진동 전달 특성 분석 및 평가 사례 연구 (A Case Study of Analysis and Evaluation of Vibration by Construction of Cast in Place Concrete Pile in the Neighboring Areas of Heunginjimun)

  • 최재성;민경원
    • 한국소음진동공학회논문집
    • /
    • 제22권9호
    • /
    • pp.870-878
    • /
    • 2012
  • This paper analysed the effect on Heunginjimun of ground vibrations due to C.I.P. works during Heunginjimun restoration period. Vibration criteria and laws for historic structures was investigated. The vibration was measured under test construction in the field, analysed and evaluated. Because the ground vibration exceeded the vibration criteria, the restoration construction could not be go along. But as vibration was transferred to the upper structures, it was confirmed that vibration levels declined, because of differences between natural and forced frequencies. If the natural frequencies database of historic structures are established, it will help with management and preservation of cultural properties by an environmental vibration effects evaluation.

고정밀 장비의 진동허용규제치에 대한 시간 및 주파수 영역에서 나타나는 불일치 문제에 관한 연구 (A Study on the Mismatch of Time and Frequency Domain for Vibration Criteria of Sensitive Equipment)

  • 이홍기;김강부;백재호
    • 반도체디스플레이기술학회지
    • /
    • 제1권1호
    • /
    • pp.1-7
    • /
    • 2002
  • Modem technology depends on the reliability of extremely high precision equipments. In the production of semiconductor wafer, optical and electron microscopes, ion-beam, laser device must maintain their alignments within a sub-micrometer. This equipment requires a vibration free environment to provide its proper function. Therefore, this high technology equipments require very strict environmental vibration criteria because it is used as basic data for the design of building structure and structural dynamics of equipment. In this paper, the new approach is proposed to investigate the mismatch problem of time and frequency domain for vibration criteria of sensitive equipment. The proposed approach is based on a vibration measurement data and a relative transfer function which can be obtained by experiment or analysis.

  • PDF

주파수 응답함수를 이용한 고정밀장비의 진동 허용규제치 결정기법에 관한 연구 (A Study on the Determination Vibration criteria for High Technology Facilities using FRF - Impact Test-)

  • 이홍기;박해동;김두훈;김사수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.377-385
    • /
    • 1996
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. the former is accurate but requires a great deal of time and efforts while the latter lacks reliability. this paper proposes a new method to solve this problem at a time. the permissible vibration level to a precision equipment can be easily obtained by analyzing a process of Frequency Response Function. This paper also demonstrates its effectiveness by applying the proposed method to finding the vibration criteria of a Computer Hard Disk Drive by impact Test.

  • PDF

준 경험기법을 이용한 고집적 반도체공장의 미진동 제어를 위한 구조물의 동적설계에 관한 연구 (A Study on the Structural Dynamic Design for Sub-micro Vibration Control in High Class Semiconductor Factor by Semi-Empirical Method)

  • 이홍기;백재호;원영재;박해동;김두훈
    • 소음진동
    • /
    • 제9권6호
    • /
    • pp.1227-1233
    • /
    • 1999
  • Modern technology depends on the reliability of extremely high technology equipments. In the production of semiconductor wafer, optical and electron microscopes, ion-beam, laser device must maintain their alignments within a nanometer. This equipment requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga and tera class semiconductor wafers. This high technology equipments require very strict environmental vibration standard, vibration criteria, in proportion to the accuracy of the manufacturing, inspecting devices. This paper deals with the structural dynamic design in high class semiconductor factory in order to be satisfied more strict vibration criteria for high sensitive equipment.

  • PDF

전신진동과 부분진동에 대한 인간의 응답특성 (Response Characteristics of Human by Whole-body Vibration and Hand-arm Vibration)

  • 장호경
    • 한국의학물리학회지:의학물리
    • /
    • 제5권2호
    • /
    • pp.77-85
    • /
    • 1994
  • 이 논문에서는 전신 과 손-팔에 전달된 진동에 대해 사람들의 주관적 진동 응답특성을 연구하였다. 인간의 진동 노출 한계를 정의하기 위하여 ISO Standard 2631 에서 지정한 일련의 진동 한계 실험 측정치를 조사하였다. 이 기준에 따라 진동에 대한 인간의 진동 응답 계산을 위한 방법이 설명되었다.

  • PDF

터널발파 진동이 도로상부에 미치는 영향 분석 (A Study on the Effect of Blasting Vibration on the road)

  • 김낙영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.821-822
    • /
    • 2014
  • When performing the tunnel excavation blasting, the lower road structure can cause the damage of the structure caused by blasting vibration. In this case the existing structurel meet all of the static and the dynamic stability. But in the domestic management of building structures is presented vibration and is the only criteria, and the criteria for major civil engineering structures insufficient research situation. This study examined the influence of the road structure according to the blast vibration by utilizing the numerical analysis.

  • PDF

APR1400 원자로내부구조물 종합진동평가 응답측정시험 허용기준 (Response Instrumentation Test Acceptance Criteria for APR1400 RVI CVAP)

  • 고도영;김규형;김성환
    • 한국소음진동공학회논문집
    • /
    • 제21권11호
    • /
    • pp.1036-1042
    • /
    • 2011
  • APR1400 RVI CVAP using the non-prototype category II is being conducted to verify integrity of the RVI design and to secure the CVAP technology. The measurement programs are to confirm vibration analysis results for reactor internals during pre-operational and initial startup testing and to determine the safety margin. One of the important basis for the measurement programs is test acceptance criteria. Therefore, this paper is on establishment of response instrumentation test acceptance criteria for APR1400 RVI CVAP. The established acceptance criteria show that the stress criteria of APR1400 RVI are more conservative values than those of the valid prototype plant(Palo Verde unit 1) and, the displacement criteria of the inner barrel assembly and the upper guide structure were established to 0.03 in and 0.01 in, respectively.