• Title/Summary/Keyword: vibrating

Search Result 929, Processing Time 0.033 seconds

Sound Radiation from Vibrating Bridges subjuct to Moving Vehicles (주행차량에 의한 교량의 동적거동과 음향방사특성)

  • 김상효;이용선;장원석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.45-51
    • /
    • 2002
  • An acoustic finite element model of a bridge is developed to evaluate the noise generated by the traffic-induced vibration of the bridge. The dynamic response of a multi-girder bridge, modeled by a 3-dimensional frame element model, is analyzed with a 3-axle 8 DOFs truck model and a 5-axle 13 DOFs semi-trailer. The flat plate element is used to analyze the acoustic pressure due to the fluid-structure interactions between the vibrating surface and contiguous acoustic fluid medium. The radiation fields of noise with a specified distribution of vibrating velocity and pressure on the structural surface are also computed using the Kirchhoff-Helmholtz integral. Although the noise produced by the bridge vibration is not serious in itself, which is below the audible frequency range, it should be considered as an interaction problem between vehicle noise and bridge vibration noise in order to evaluate the traffic noise around the bridge.

  • PDF

Sound Radiation Characteristics of A Cracked Rectangular Vibrating Plate (균열을 갖는 직사각형 진동평판의 음향 방사특성)

  • 김태진;박종환;이우식
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.3
    • /
    • pp.163-168
    • /
    • 2003
  • This paper considers the sound radiation characteristics of a cracked rectangular vibrating plate, varying the orientation angle of a line crack. The vibration response of the cracked vibrating plate is obtained by using ANSYS, the acoustic theory based on the lumped parameter model is used to calculate radiated sound power. The radiated sound powers are computed with varying the orientation angle of the crack: i.e, 0$^{\circ}$, 45$^{\circ}$, and 90$^{\circ}$. It is found that characteristics of the radiated sound power are very closely related to the crack orientation, vibration mode and crack location.

Suggestion of the Structure for Development of Smart Pants with Vibrating Massaging Function (진동 안마 기능의 스마트 팬츠 개발을 위한 설계 제안)

  • Choi, Sun-Yoon;Lee, Jeong-Ran
    • Fashion & Textile Research Journal
    • /
    • v.9 no.3
    • /
    • pp.327-335
    • /
    • 2007
  • As the digital environment gets ubiquitous, domestic and international research and development on smart clothing is being conducted actively these days. However, most research is being carried out with its center on upper garment. So research on lower garment is insufficient even though it affects wearer's activity and comfort to a great extent when digital devices are attached or wearers moves their body. Therefore, the type of clothes this research proposes is men's formal pants which have an electrically-vibrating wearable device. These are smart pants which are helpful in easing muscle pain with their massaging effect in daily life. For this purpose, this research intends to develop patterns considering the body shapes and movements of wearers and suggest a tentative structure plan for smart pants where a vibration device is attached, which is mainly composed of vibrating motor, controller, and switch, and considered their bulks, numbers, attaching places.

Sensorless Vibratory Orienting of Small Polygonal Parts (소형 다각형 부품의 비센서 진동 정렬)

  • Han, In-Hwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.11
    • /
    • pp.1111-1118
    • /
    • 2006
  • This paper covers topics related to the investigations for the problem of sensorless vibratory orienting of polygonal parts with high probability through dynamic simulation. The author's program for mechanical systems with changing topologies was experimentally validated and was used as a simulation and design tool for motion behaviors of the vibratory parts-orienting system in the dynamic environment. A flat level vibrating bar is proposed as a means of orienting parts. Dynamic manipulation, in which a part is repeatedly caught and tossed by the bar without sensing, forms the fundamental manipulation strategy. This paper presents how to plan vibratory manipulation strategies that can orient a small rigid polygonal part using interaction between the part and the vibrating bar without requiring sensing. The planned motion strategies have been experimentally validated to show how the dynamic simulation can be used to find favorable vibration parameters for a given part without knowledge of their initial orientations.

An Experimental Study on the Design-Concerte for Precast Concerte (문양 콘크리트의 PC 적용을 위한 실험적 연구)

  • Kim Jae Eun;An Moo Young;Kim Kwang Ki;Cho Sang Young;Kim Woo Jae;Jung Sang Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.161-164
    • /
    • 2004
  • The object of this study is vibrating compaction and curing method in the production process of Design concrete for precast concrete(Design-PC) product. From change of vibrating compaction time and pre-curing time, curing temperature which would be factors of product quality in Design-PC concrete production, and research of optimized steam curing condition from relations between curing condition and strength development, basic data of vibrating compaction time and concrete steam curing method for Design-PC will be presented.

  • PDF

Development of An Automated Scanning Laser Doppler Vibrometer For Measurements of In-Plane Structural Vibration (평면 구조 진동 측정을 위한 자동화된 스캐닝 레이저 도플러 진동측정기의 개발 및 연구)

  • 길현권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.422-430
    • /
    • 1996
  • The automated scanning laser Doppler vibrometer (LDV) has been designed, and built to measure in-plane displacements associated with waves propagating on vibrating structures. Use of optical fibers allows the compact design of a laser probe head which can be scanned over the vibrating structures. An algorithm for automated self-alignment of the laser probe is developed. The system is completely automated for scanning over the structures, focusing two laser beams at each data point until the detected vibration signal is stable, and for recording and transferring the data to a system computer. The automated system allows one to get extensive data of the vibration field over the structures. The system is tested by scanning a piezoelectric cylindrical shell and a plate excited by a continuous signal and by a pulse signal, respectively. Results show that the automated scanning LDV system can be a useful tool to measure the in-plane vibration field and to detect the elastic waves propagating on the vibrating structures.

  • PDF

Design of Vibrating Transducer for Implantable Middle Ear Hearing Aid (이식형 중이 청각보조기를 위한 진동 트랜스듀서의 설계)

  • 박형욱
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.535-544
    • /
    • 1996
  • In this paper, we analyzed the coil-magnet type vibrating transducer for the implantable middle ear hearing aid which is appropriate for patient's hearing level, and an experimental transducer system is designed For the objective and quantitative analysis of the transducer, a theoretical equivalent model containing coil, magneto and inner ear is developed To perform effective evaluation of the transducer, a transforming ratio Tr is introduced and its range that is suitable for practical implantable middle ear hearing device is foun4 The result of applying physical parameters of ear system to the proposed analytical model shows that frequency response of the coil magrlet type vibrator is predominantly governed by resistive impedance of the coil rather than inertia effect of the magnet and the inner parameters. In addition, we realized an experimental middle ear hearing aid system to show the theoretical validity of designed system and this will provide the basis of the development for actually implantable system.

  • PDF

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

An Experimental Study on the Flexural Strength of Construction Joints of RC Slabs at Widened Bridges (교량 확폭시 RC 상판 접합부의 휨강도에 관한 실험적 연구)

  • 배인환;심종성;장동일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.04a
    • /
    • pp.188-193
    • /
    • 1993
  • In widening of existing bridges, construction joints between old new parts of concrete slabs are subjected to repeated traffic loads during placing and curing of concrete. Therefore, the main focus of this paper is given to examine several construction methods of bridge widening. As a result, the occurrence of cracks in vibrating specimen is faster than non-vibrating one, but the difference between flexural strength and ultimate moment was negligible. Also, it shows the same result in other construction method, say direct and non-shrinkage joint specimen.

  • PDF

Sound velocity effect on vibrating gas densimeter (음속이 진동형 기체 밀도 측정기에 미치는 영향)

  • Lee, W.G.;J.W. Chung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.1
    • /
    • pp.28-33
    • /
    • 1993
  • Measurements errors due to sound velocity effect on vibrating gas densimeters were described. Nitrogen was used to calibrate the densimeter, and oxygen was employed to determine a coefficient for the compensation of sound velocity effect. Sound velocity effects were shown with methane at temperatures of 7.97, 19.93 and 39.57 .deg. C, and pressures up to 3.6 Mpa. A relative error of about 1% was introduced when the nitrogen calibrated densimeter was used to measure densities of pure methane. A method of sound velocity effect compensation was able to reduce the error down to 0.1%.

  • PDF