• 제목/요약/키워드: vertical plane connection

검색결과 17건 처리시간 0.028초

An experimental study of the behaviour of double sided welded plate connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.1-22
    • /
    • 2018
  • Multi-storey precast concrete skeletal structures are assembled from individual prefabricated components which are erected on-site using various types of connections. In the current design of these structures, beam-to-column connections are assumed to be pin jointed. Welded plate beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is at present limited information concerning their detailed structural behaviour under bending and shear loadings. The experimental work has involved the determination of moment-rotation relationships for semi-rigid precast concrete connections in full scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and weld arrangements conformed with successful commercial practice. Proprietary hollow core slabs were tied to the beams by tensile reinforcing bars, which also provide the in-plane continuity across the connections. The strength of the connections in the double sided tests was at least 0.84 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.7 to 3.9 times the flexural stiffness of the attached beam. When the connections were tested without the floor slabs and tie steel, the reduced strength and stiffness were approximately a third and half respectively. This remarkable contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. In general, the double sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided welded plate connection test results are presented in this paper. The behaviour of single sided welded plate connection test results is the subject of another paper.

저잡음지역(3.5mV/m)의 AM방송송신 안테나 효율에 관한 연구 (A Study on the efficiency of AM Broadcast Transmitting Antenna in assordance with a low noise Area)

  • 이문호
    • 한국통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.40-43
    • /
    • 1980
  • AM放送은 周波數(525~1605KHz)에 따라 放送區域(Service area)에 현저한 差異를 가져온다. 都市雜音이 增加됨에 따라 放送區域(Service area)이 縮小가 되고 있다. 따라서 送信出力을 增强하지 않은 한, 低雜音地域(3.5mV/m)에서 送信안테나의 效率을 增加시켜야 한다. 送信안테나 效率은 大地接地저항과 函數관계가 있다. 수직접지 안테나를 使用하고 있는 우리나라의 標準 AM 放送은 Radial ground System을 쓰고 있다.

  • PDF

Skybridges: A History and a View to the Near Future

  • Wood, Antony;Safarik, Daniel
    • 국제초고층학회논문집
    • /
    • 제8권1호
    • /
    • pp.1-18
    • /
    • 2019
  • As many architects and visionaries have shown over a period spanning more than a century, the re-creation of the urban realm in the sky through connections between buildings at height has a vast potential for the enrichment of our cities. To many it seems nonsensical that, although the $20^{th}$ and now $21^{st}$ century, have clearly seen a push towards greater height and urban density in our major urban centers, the ground-pavement level remains almost exclusively the sole physical plane of connection. As the world rapidly urbanizes, greater thought needs to be expended on how horizontal space can be developed at height. This paper briefly describes the history, present classifications and uses, and potential future development potential of skybridges between tall buildings.

C형 접합부를 이용한 프리캐스트 콘크리트 전단벽의 거동 (Behavior of Precast Concrete Shear Walls with C-Type Connections)

  • 임우영;홍성걸
    • 콘크리트학회논문집
    • /
    • 제22권4호
    • /
    • pp.461-472
    • /
    • 2010
  • 이 논문은 새로운 수직 접합부를 가진 프리캐스트 벽체의 거동에 관한 연구이다. PC 벽체를 이용한 리모델링 건설을 위해서는 효율적이고 경제적인 조립 방법이 필요하다. C형 수직 접합부를 가진 PC 벽체 시스템은 수직방향의 벽체 사이의 휨모멘트를 전달하도록 하고, 반면에 벽체 중심에 있는 전단키는 전단력을 부담하도록 하였다. 제안된 수직 접합부는 벽체 단부에 서로 다른 방향의 슬롯 때문에 조립이 용이하다. 횡력을 받는 일자형 PC 벽체 시스템을 강성, 강도 그리고 파괴 모드에 대해 기존의 RC 벽체와 비교하였으며, 힘과 처짐과의 관계와 접합부의 조기파괴에 관해 알아보았다. 실험 결과 벽체 단부에 설치된 수직 철근이 먼저 항복하였고, 최종 변형은 접합부의 조기 파괴에 의해 결정되었다. 그리고 벽체에서 효과적인 전단력 전달을 위한 대각선 철근은 그다지 효과적이지 않았다. 단면 해석을 통해 구한 강도와 변형은 실험값과 대체로 일치하였다. 특히, 개폐거동에 의한 변형이 가장 큰 비율을 차지하였다.

Bending Behavior of Nailed-Jointed Cross-Laminated Timber Loaded Perpendicular to Plane

  • Pang, Sung-Jun;Kim, Kwang-Mo;Park, Sun-Hyang;Lee, Sang-Joon
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권6호
    • /
    • pp.728-736
    • /
    • 2017
  • In this study, the bending behavior of cross-laminated timber (CLT) connected by nails were investigated. Especially, the load-carrying capacity of the nail-jointed CLT under out-of-plane bending was predicted by the lateral resistance of the used nails. Three-layer nail-jointed CLT specimens and a nail connection were manufactured by 30 mm (thickness) ${\times}$ 100 mm (width) domestic species (Pinus koraiensis) laminas and Ø$3.15{\times}82mm$ nails using a nail-gun. Shear test for evaluating the nail lateral resistance and bending test for evaluating the load-carrying capacity of the nail-jointed CLT under out-of-plane bending were carried out. As a result, two lateral resistance of the used nail, the 5% fastener offset value and the maximum value, were 913 N and 1,534 N, respectively. The predicted load-carrying capacity of the nail-jointed CLT by the 5% offset nail lateral resistance was similar to the yield points on the actual load-displacement curve of the nail-jointed CLT specimens. Meanwhile, the nail-jointed CLT specimens were not failed until the tension failure of the bottom laminas occurred beyond the maximum lateral resistance of the nails. Thus, the measured maximum load carrying capacities of the nail-jointed CLT specimens, approximately 12,865 N, were higher than the predicted values, 7,986 N, by the maximum nail lateral resistance. This indicates that the predicted load-carrying capacity can be used for designing a structural unit such as floor, wall and roof able to support vertical loads in a viewpoint of predicting the actual capacities more safely.

부산도시보건소의 기능별 공간구성 및 면적배분에 관한 연구 (AA Study of Spatial Composition and Area Distribution by Function in Public Health Centers of Busan)

  • 조희영;윤소희;김석태
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제21권2호
    • /
    • pp.55-65
    • /
    • 2015
  • Purpose: Korea is increasing in the demand for medical services due to rapid economic growth and population aging in modern society. Thus, the importance has been emphasized for the health promotion in the community and the publicity and substantiality of public health centers. However, the environment is insufficient, compared to required functions and developed services as a urban public health center. The purpose of this study is to analysis the plane type and area composition of public health centers in Busan and to identify the property of their spatial configuration Methods: Eight public health centers in Busan, were classified, which had been selected as a medical tourism city. Subsequently, space requirements were analyzed, facilities were typed, vertical, horizontal spaces were reviewed, and area ratios by business function were calculated. Results: A review of the property of spatial configuration and an analysis of the area ratio revealed the three findings. 1)The horizontal analysis found various types: a single type, a multi-type, a radial type, and a circular type, 2)The vertical analysis showed that since a care function (general practice), and a task function (maternal and child health) were concentrated in lower level spaces, the lobby and core were closed located for providing quick medical services. 3)The analysis of the area ratio in public health centers in terms of their function indicated that each public health center' programs had the greatest influence on the area. Implications: This study attempted to present spatial structural problems and improvements for city public health center by identifying their state and classify their functions and types and by calculating the ratio of their area configuration according to the spatial composition. It was thus aimed to presenting implications in establish public functions and roles by activating business through in connection with the number of municipalities in many ways, such as regional health. medical welfare, etc. to improve the health of local residents, and by providing differentiated programs in accordance with local characteristics.

Integrated analysis and design of composite beams with flexible shear connectors under sagging and hogging moments

  • Wang, A.J.;Chung, K.F.
    • Steel and Composite Structures
    • /
    • 제6권6호
    • /
    • pp.459-477
    • /
    • 2006
  • A theoretical research project is undertaken to develop integrated analysis and design tools for long span composite beams in modern high-rise buildings, and it aims to develop non-linear finite element models for practical design of composite beams. As the first paper in the series, this paper presents the development study as well as the calibration exercise of the proposed finite element models for simply supported composite beams. Other practical issues such as continuous composite beams, the provision of web openings for passage of building services, the partial continuity offered by the connections to columns as well as the behaviour of both unprotected and protected composite beams under fires will be reported separately. In this paper, details of the finite elements and the material models for both steel and reinforced concrete are first described, and finite element studies of composite beams with full details of test data are then presented. It should be noted that in the proposed finite element models, both steel beams and concrete slabs are modelled with two dimensional plane stress elements whose widths are assigned to be equal to the widths of concrete flanges, and the flange widths and the web thicknesses of steel beams as appropriate. Moreover, each shear connector is modelled with one horizontal spring and one vertical spring to simulate its longitudinal shear and pull-out actions based on measured load-slippage curves of push-out tests of shear connectors. The numerical results are then carefully analyzed and compared with the corresponding test results in terms of load mid-span deflection curves as well as load end-slippage curves. Other deformation characteristics of the composite beams such as stress and strain distributions across the composite cross-sections as well as distributions of shear forces and slippages in shear connectors along the beam spans are also examined in details. It is shown that the numerical results of the composite beams compare well with the test data in terms of various load-deformation characteristics along the entire deformation ranges. Hence, the proposed analysis and design tools are considered to be simple and yet effective for composite beams with practical geometrical dimensions and arrangements. Structural engineers are strongly encouraged to employ the models in their practical work to exploit the full advantages offered by composite construction.