• Title/Summary/Keyword: vertical link beam

Search Result 10, Processing Time 0.022 seconds

Study of an innovative two-stage control system: Chevron knee bracing & shear panel in series connection

  • Vosooq, Amir Koorosh;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • v.47 no.6
    • /
    • pp.881-898
    • /
    • 2013
  • This paper describes analytical investigation into a new dual function system including a couple of shear links which are connected in series using chevron bracing capable to correlate its performance with magnitude of earthquakes. In this proposed system, called Chevron Knee-Vertical Link Beam braced system (CK-VLB), the inherent hysteretic damping of vertical link beam placed above chevron bracing is exclusively utilized to dissipate the energy of moderate earthquakes through web plastic shear distortion while the rest of the structural elements are in elastic range. Under strong earthquakes, plastic deformation of VLB will be halted via restraining it by Stopper Device (SD) and further imposed displacement subsequently causes yielding of the knee elements located at the bottom of chevron bracing to significantly increase the energy dissipation capacity level. In this paper first by studying the knee yielding mode, a suitable shape and angle for diagonal-knee bracing is proposed. Then finite elements models are developed. Monotonic and cyclic analyses have been conducted to compare dissipation capacities on three individual models of passive systems (CK-VLB, knee braced system and SPS system) by General-purpose finite element program ABAQUS in which a bilinear kinematic hardening model is incorporated to trace the material nonlinearity. Also quasi-static cyclic loading based on the guidelines presented in ATC-24 has been imposed to different models of CK-VLB with changing of vertical link beam section in order to find prime effectiveness on structural frames. Results show that CK-VLB system exhibits stable behavior and is capable of dissipating a significant amount of energy in two separate levels of lateral forces due to different probable earthquakes.

A Study on the Modeling and Control of a Flexible One-Link Manipulator Moving in a Vertical Plane (수직면에서 회전운동 하는 단일 탄성링크를 가지는 매니퓰레이터의 모델링과 제어에 관한 연구)

  • Kim, Jongdae;Oh, Seokhyung;Kim, Kiho;Oh, Chaeyoun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.11
    • /
    • pp.132-142
    • /
    • 1996
  • This paper presents a technique to model and control a manipulator which has a flexible link and moves in a vertical plane. The flexible link is modeled as an Euler-Bernoulli Beam. Elastic deformation of the flexible link is represented using the assumed modes method. A comparison function which satisfies all geometric and natural boundary conditions of a cantilever beam with an end mass is used as an assumed mode shape. Lagrange's equation is utilized for the development of a discretized model. This paper presents a simple technique to improve the correctness of the developed model. The final model including the shortening effect due to elastic deformation correlates very well with experimental results. The free body motion simulation shows that two assumed modes for the representation of the elastic deformation is proper in terms of the model size and correctness. A control algorithm is developed using PID control technique. The proportional, integral and derivative control gains are determined based on dominant pole placement method with a rigid one-link manipulator. A position control simulation shows that the control algorithm can be used to control the position and residual oscillation of the flexible one-link manipulator effectively.

  • PDF

Cyclic testing of innovative two-level control system: Knee brace & vertical link in series in chevron braced steel frames

  • Rousta, Ali Mohammad;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • v.64 no.3
    • /
    • pp.301-310
    • /
    • 2017
  • For further development of passive control systems to dissipate larger seismic energy and prevent the structures from earthquake losses, this paper proposes an innovative two-level control system to improve behavior of chevron braced steel frames. Combining two Knee Braces, KB, and a Vertical Link Beam, VLB, in a chevron braced frame, this system can reliably sustain main shock and aftershocks in steel structures. The performance of this two-level system is examined through a finite element analysis and quasi-static cyclic loading test. The cyclic performances of VLB and KBs alone in chevron braced frames are compared with that of the presented two-level control system. The results show appropriate performance of the proposed system in terms of ductility and energy dissipation in two different excitation levels. The maximum load capacity of the presented system is about 30% and 17% higher than those of the chevron braced frames with KB and VLB alone, respectively. In addition, the maximum energy dissipation of the proposed system is about 78% and 150% higher than those of chevron braced frames with VLB and KB respectively under two separate levels of lateral forces caused by different probable seismic excitations. Finally, high performance under different earthquake levels with competitive cost and quick installation work for the control system can be found as main advantages of the presented system.

Design of active beam steering antenna mounted on LEO small satellite (저궤도 소형위성 탑재용 빔 조향 능동 다이폴 안테나 설계)

  • Jeong, Jae-Yeop;Park, Jong-Hwan;Woo, Jong-Myung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.197-203
    • /
    • 2016
  • In this paper, the dipole antenna that can control a beam steering were designed for attaching on LEO(Low Earth Orbit) small satellite. The proposed antenna was based on Yagi-Uda antenna. The parasitic element was proposed as a T-shape. Depending on the state of open or short at the end of a vertical element, we can choose a characteristic of the parasitic element with fixing a vertical element length of the parasitic element. Using this characteristic, we designed the director element and reflector element. The proposed antenna was designed to receive UHF 436.5 MHz. Antenna gain was chosen by link budget between one satellite and the other satellite or between the satellite and the ground station. By changing a vertical element length which is the largest variable that chooses an antenna characteristic, we confirmed that ${\lambda}/2$ length transformer has a result that improve 0.5 dB in comparison ${\lambda}/4$ length transformer from maximum gain direction. In production, we made an on/off switch composed of a diode, capacitor, and inductor control an open and short at the end of the parasitic element. As a result, the gain of antenna used in a link between one satellite and the other satellite had average 5.92 dBi. And the gain of antenna used in a link between the satellite and the ground station had average 0.99 dBi.

Cyclic testing of chevron braced steel frames with IPE shear panels

  • Zahrai, Seyed Mehdi
    • Steel and Composite Structures
    • /
    • v.19 no.5
    • /
    • pp.1167-1184
    • /
    • 2015
  • Despite considerable life casualty and financial loss resulting from past earthquakes, many existing steel buildings are still seismically vulnerable as they have no lateral resistance or at least need some sort of retrofitting. Passive control methods with decreasing seismic demand and increasing ductility reduce rate of vulnerability of structures against earthquakes. One of the most effective and practical passive control methods is to use a shear panel system working as a ductile fuse in the structure. The shear Panel System, SPS, is located vertically between apex of two chevron braces and the flange of the floor beam. Seismic energy is highly dissipated through shear yielding of shear panel web while other elements of the structure remain almost elastic. In this paper, lateral behavior and related benefits of this system with narrow-flange link beams is experimentally investigated in chevron braced simple steel frames. For this purpose, five specimens with IPE (narrow-flange I section) shear panels were examined. All of the specimens showed high ductility and dissipated almost all input energy imposed to the structure. For example, maximum SPS shear distortion of 0.128-0.156 rad, overall ductility of 5.3-7.2, response modification factor of 7.1-11.2, and finally maximum equivalent viscous damping ratio of 35.5-40.2% in the last loading cycle corresponding to an average damping ratio of 26.7-30.6% were obtained. It was also shown that the beam, columns and braces remained elastic as expected. Considering this fact, by just changing the probably damaged shear panel pieces after earthquake, the structure can still be continuously used as another benefit of this proposed retrofitting system without the need to change the floor beam.

The Design of Planar Beam Tilt Antenna for Satellite up-link Communication in Ka-band (Ka-band 위성통신 up-link 용 평면형 빔틸트 안테나의 설계)

  • Lim, Gye-jae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.3
    • /
    • pp.101-109
    • /
    • 2012
  • Because the installation problem of parabola antenna that is tilted to 45 degree when this antenna is installed at the area of middle latitude, the study on planar antenna in place of parabola antenna is made rapid progess. Especially, The development of the planar antenna for VSAT is needed depending on the increased Ka-band satellite communications. In this paper, in order to meet with these performances, an array antenna consisting of the vertical polarized waveguide longitudinal slots based on the leaky-wave mode of traveling wave antenna is proposed. Especially, for the lower sidelobe level, the design method of the radiation power distribution control using the different slot widths is proposed. An array antenna consisting of 32 leakywave waveguide antennas is showing 35.16 dBi of gain, 2.5 degree of beamwidth at azimuth, below than -30 dB of sidelobe level, 45.8 degree of beam tilt angle in center frequency 30.2 GHz.

Finite Element Analysis of Continuous Beam Vibration under Pedestrian Loading Considering Moving Mass Effect (이동 질량 효과를 고려한 연속 보의 보행하중 진동 유한요소 해석)

  • Park, Wonsuk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.5
    • /
    • pp.309-316
    • /
    • 2022
  • This study proposes a finite element analysis method that can analyze the vibration of a beam by considering the inertia effect of moving masses in a vertical direction. The proposed method is effective when a precise interaction analysis is not required. The inertial effects of the moving masses are included in the equation of motion, and the interaction forces between the masses and the beam are considered only as external loads. Time domain analyses were performed using Abaqus, a general-purpose finite element analysis software, and an implementation method using multi-point constraints wais presented to link the displacements of the beam element nodes and moving rigid masses. The proposed method was verified by comparing its solution with that obtained using an existing analytical method, and the analysis results for continuous beam vibrations under dynamic gait loadings were used to examine the mass effect of pedestrians.

Modelling and Analysis of Roll-Type Steel Mats for Rapid Stabilization of Permafrost (I) - Modeling - (영구동토 급속안정화를 위한 롤타입강재매트의 모델링과 해석(I) - 해석모델의 수립 -)

  • Moon, Do Young;Kang, Jae Mo;Lee, Janggeun;Lee, Sang Yoon;Zi, Goangseuo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.4
    • /
    • pp.97-107
    • /
    • 2014
  • Finite element modelling and analysis were conducted for the roll-type steel mats which were placed on loose sand and subjected to a standard truck wheel load in this study. The roll-type steel mats mean that the steel mats can be folded as a circle shape for the carrying to fields in cold regions where workability is limited and are developed for a rapid rehabilitation method for roadway across soft ground which is caused by thawing during the summer season in cold regions. The model is composed of link elements to simulate nonlinear behavior of connections between steel mats, thick shell elements to have flexural stiffness of the steel mats, and springs to simulate characteristics of foundation soils. The structural behaviors of the shell, link elements, and springs were verified at each modelling step through experiment and analysis. Beam and shell analysis without the link elements were conducted and compared to results obtained from the model presented in this study. Significant vertical displacement is shown in the shell model with hinge connections. Therefore, the results demonstrate that the analysis model for the roll-type steel mats on loose sand needs further detail parametric studies.

Vibration Control of a Robot Manipulator with a Parallel Drive Mechanism (평행구동방식 로봇 조작기의 진동제어)

  • 최승철;하영균;박영필
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2015-2025
    • /
    • 1991
  • A long and light-weight forearm of the vertical 2 DOF robot manipulator with a heavy payload driven by parallel drive mechanism is modelled as a Euler-Bernoulli beam with a tip mass subjected to a high speed rotation. Governing equation is obtained by Hamilton's principle and represented as state variable form using the perturbed variables which describe the perturbed errors at the manipulator's final configuration. Digitial optimal control and observer theory are used to suppress the forearm vibration and control the positions of the joint angles with measured/estimated state feedback. Computer simulations and experimental results are obtained and compared each other.

Lateral Stiffness and Natural Period Evaluation of Flat Plate Tall Buildings for Wind Design (내풍설계를 위한 초고층 무량판 건축물의 횡강성 및 고유주기 산정)

  • Park, Je-Woo;Kim, Hong-Jin;Jo, Ji-Seong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.73-80
    • /
    • 2010
  • Wind-induced vibration is one of the important structural design factors for serviceability of tall buildings. In order to evaluate the reliable wind-loads and wind induced-vibration, it is necessary to obtain the exact natural period of buildings. The discrepancy in the natural period estimation often results in the overestimation of wind loads. In this study, the effectiveness of lateral stiffness estimation method for tall buildings with flat plate system is evaluated. For this purposed, the results of finite element analysis of three recently constructed buildings are compared with those obtained from field measurement. For the analysis, factors affecting on the lateral resistance such as cracked stiffness of vertical members, elastic modulus of concrete, effective slab width, and cracked stiffness of link beam are considered. Form the results, it is found that the use of non-cracked stiffness and application of dynamic modulus of elasticity rather than initial secant modulus yields closer analysis result to the as-built period.