• 제목/요약/키워드: vertical line test

검색결과 168건 처리시간 0.022초

765kV 수직2회선 6도체 현수형 철탑에서 직접활선작업의 안전성 평가분석 (Analysis of Electrical Safety Level Test for Barehand Work at 765kV Vertical Double Circuit Six Bundle Conductors on the Suspension String Tower Type)

  • 김대식;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.275-278
    • /
    • 2008
  • It has been issued that the necessity of Live line work for 765kV vertical double circuit six bundle conductors transmission line when the characteristics of transmission line, the composition of T/L and near the T/L circumstances etc. Others are considered. The Barehand method of UHV T/L is extremely dangerous work and especially it is directly related with lineman life so it is very dangerous. It should be performed several technology developments for live-line work on the UHV T/L, that should be considered such as the electrical influence on workers near the T/L, development of live-line facilities, guarantee of safety, the technical rules of live-line work, the safe method of live-line work and etc. In order to maintain the 765kV transmission lines safely by barehand work, first of all, we should know the analysis of electrical safety level test in live-line work at 765kV vertical double circuit six bundle conductors on the suspension string tower type.

노반에 작용하는 수직응력 및 침하량에 관한 기초 연구 (Basic research to evaluate the vertical stresses and settlements on the subgrade)

  • 김대상;이진욱;이수형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1052-1057
    • /
    • 2004
  • Various amplitudes and frequencies of axle loads are applied to the domestic conventional line. Vertical stresses and settlements on the subgrade may be changed depending on the variation of axle loads. This paper introduces the research results to estimate vertical stresses and settlements on the subgrade with numerical analysis(Distinct Element Method), full scale test, and field test.

  • PDF

무도상 판형교의 동적거동특성 분석을 위한 실험적 연구 (Field Test to Investigate Dynamic Characteristics of Steel Plate Girder Railway Bridges without Ballast)

  • 최진유;오지택;김현민;이상배
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.678-683
    • /
    • 2002
  • Field measurements were conducted to analysis dynamic characteristics of existing steel plate girder railway bridges without ballast. Three bridges which have 9m, 12m, 18m span length in Kyoung-Bu and Ho-Nam Line were selected for test. According to the each bridge, dynamic vertical deflections and vertical and horizontal accelerations were measured. Natural frequencies, vertical deflections and accelerations obtained from field tests were compared with the limit value specified in the UC, Japanese and Korean railway bridge specification.

  • PDF

피동 주입 시험 장치의 척도 해석 및 설계 방법론 연구 (Study on Scaling Analysis and Design Methodology of Passive Injection Test Facility)

  • 배황;이민규;류성욱;신수재;김영인;이성재;박현식
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.50-60
    • /
    • 2016
  • A design methodology of the modeled test facility to conserve an injection performance of a passive safety injection system is proposed. This safety injection system is composed of a core makeup tank and a safety injection tank. Individual tanks are connected with pressure balance line on the top side and injection line on the bottom side. It is important to conserve the scaled initial injection flow rate and total injection time since this system can be operated by small gravity head without any active pumps. Differential pressure distribution of the injection line induced by the gravity head is determined by the vertical length and elevation of each tank. However, the total injection time is adjustable by the flow resistance coefficient of the injection line. The scaling methodology for the tank and flow resistance coefficient is suggested. A key point of this test facility design is a scaling analysis for the flow resistance coefficient. The scaling analysis proposed on this paper is based on the volume scaling law with the same vertical length to the prototype and can be extended to a model with a reduced vertical length. A set of passive injection test were performed for the tanks with the same volume and the different length. The test results on the initial flow rate and total injection time showed the almost same injection characteristics and they were in good agreement with the design values.

실증시험을 통한 강관주기초의 거동특성 (Behavior of Single Pole Foundation using Experimental Study)

  • 김대홍;오기대
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.598-604
    • /
    • 2010
  • The drilled pier foundation is widely used to support transmission line structures due to its simplicity of construction. When this foundation type is used in conjunction with a single shaft or H-frame structure, it is subjected to a high overturning moment, combined with modest vertical and shear loads. Since the length and diameter of drilled piers are often governed by a maximum permissible deflection, many drilled piers being installed today are very conservatively designed. In this study, Nine prototype field-tests (1/8 scale) have been conducted in order to determine the vertical and lateral resistance of drilled pier foundation for single pole structures. These test results reveal the test piers behaved essentially as rigid bodies in soil (6D) and the center of rotation of the pier were typically 0.6~0.4 of the pier depth below ground surface. Test results also show the relationship between the applied load and the deflection at the top of the pier is highly nonlinear.

  • PDF

표면 근전도와 전기 탐침기를 이용한 상완이두근의 운동점 표지 비교 연구 (Comparison Study about Surface Mapping of Motor Points in Biceps Brachii Muscle Using Surface EMG and Electric Probe)

  • 박재원;금동호
    • 한방재활의학과학회지
    • /
    • 제28권1호
    • /
    • pp.85-96
    • /
    • 2018
  • Objectives This study was performed to compare the electrical methods of motor points mapping using surface EMG and electric probe (Pointer Excel II). Methods 32 healthy adults (male 16, female 16) were selected. and classified into two groups; surface EMG group, electric probe (Pointer Excel II) group. In surface EMG group, motor points were searched by recoding the compound muscle potentials. In electric probe (Pointer Excel II) group, motor points were searched by scanning the skin with Pointer Excel II at low level stimulation. The locations of the motor points were expressed as X and Y values in relation to the reference line. The horizontal reference line was set as elbow crease and the vertical reference line was set as the line connecting coracoid process to the center of the horizontal reference line. The data was analyzed by 'Independent T-test' and 'equivalence test'. Results 1. The motor points of short head and long head of biceps brachii muscle were located at about 2/3 length of the vertical reference line from coracoid process and about 1/5~1/4 length of the half of the horizontal reference line from the vertical reference line in both group. 2. The motor points of the short head were located more distally and close to the vertical reference line (p<0.001). 3. In surface EMG group, the motor points of the long head were located more laterally in the female than male. And the motor points of the long head were located more distally in the left side than right side (p<0.05). In electric probe (Pointer Excel II) group, similar tendency was observed but there was no statistically significant difference (p>0.05). 4. As a result of the equivalence test between surface EMG group and electric probe (Pointer Excel II) group, the confidence intervals of the difference were within the equivalence limit. Therefore, the locations of the motor points searched by two ways are equa l (p>0.05, equivalence interval=3%). Conclusions The results indicate that electric probe (Pointer Excel II) can be used to search the motor points instead of surface EMG. This might improve the clinical efficiency when using the motor points to treat muscle dysfunction.

Automatic Building Reconstruction with Satellite Images and Digital Maps

  • Lee, Dong-Cheon;Yom, Jae-Hong;Shin, Sung-Woong;Oh, Jae-Hong;Park, Ki-Surk
    • ETRI Journal
    • /
    • 제33권4호
    • /
    • pp.537-546
    • /
    • 2011
  • This paper introduces an automated method for building height recovery through the integration of high-resolution satellite images and digital vector maps. A cross-correlation matching method along the vertical line locus on the Ikonos images was deployed to recover building heights. The rational function models composed of rational polynomial coefficients were utilized to create a stereopair of the epipolar resampled Ikonos images. Building footprints from the digital maps were used for locating the vertical guideline along the building edges. The digital terrain model (DTM) was generated from the contour layer in the digital maps. The terrain height derived from the DTM at each foot of the buildings was used as the starting location for image matching. At a preset incremental value of height along the vertical guidelines derived from vertical line loci, an evaluation process that is based on the cross-correlation matching of the images was carried out to test if the top of the building has reached where maximum correlation occurs. The accuracy of the reconstructed buildings was evaluated by the comparison with manually digitized 3D building data derived from aerial photographs.

벤토나이트 케익을 고려한 연직차수벽의 순간변위시험(slug test) 해석 (Consideration of Bentonite Cake Existing on Vertical Cutoff Wall in Slug Test Analysis)

  • 임지희;웽 테 바오;이동섭;안재윤;최항석
    • 한국지반공학회논문집
    • /
    • 제29권6호
    • /
    • pp.5-17
    • /
    • 2013
  • 순간변위시험(slug test)은 현장의 지반 상태를 반영할 수 있어 연직차수벽 뒷채움재의 투수계수를 결정하는데 적용할 수 있다. 본 논문에서는 연직차수벽과 주변 지반 사이에 형성되는 벤토나이트 케익을 고려하여 순간변위시험을 모사할 수 있는 3차원 모델이 개발되었다. 연직차수벽의 폭(즉, 경계 조건과의 근접 정도), 우물의 편심, 우물에 지하수가 유입되는 수직 위치, 뒷채움재의 압축성 등의 영향변수들이 모델에 고려되었다. 수치해석 결과를 이용하여 연직차수벽 시공 중에 존재할 수 있는 벤토나이트 케익이 순간변위시험 결과에 미치는 영향을 평가하였다. 이를 통해, 수정 Line-fitting법은 벤토나이트 케익을 고려한 연직차수벽의 순간변위시험 해석에서 다른 경계조건에 대해 제시된 보정계수 없이 직접 적용될 수 있음을 밝혔다. 본 논문에서는 기존의 현장 사례를 벤토나이트 케익을 고려하여 재분석하여 벤토나이트 케익이 존재하지 않는 경우(일정 수두 경계 조건)와 보수적인 경계조건(불투수 경계 조건)으로 가정했던 기존의 사례분석 결과들과 비교하였다. 결론적으로 연직차수벽 뒷채움재의 투수계수 평가시 벤토나이트 케익의 영향 및 수정 Line-fitting법의 유효성을 확인하였다.

대형압밀시험기를 이용한 동슬래그 다짐말뚝의 배수 특성 (Drainage Characteristics of Copper Slag Compaction Pile Installed in Clay Based on the Laboratory Consolidation Model Test)

  • 천병식;정헌철;김경민;조한영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.552-557
    • /
    • 2001
  • Copper slag is the by-producted material on the proceeding of refining the copper. To verify applications of copper slag to vertical drain material can substitute for the sands in ground improvement, laboratory soil tests and consolidation model tests were conducted. The results of consolidation model test was analyzed as the hyperbolic method. The hyperbolic method assumes that the settlement(s) versus time(t) behavior approaches a straight line describes a hyperbolic reaction. The inverse of the slope of the line would then yield the ultimate settlement. Through in this study, copper slag is compatible with vertical drain material as like sands. Copper slag compaction pile promote the consolidation settlement.

  • PDF

수정 Bouwer and Rice 법을 이용한 필터케이크가 존재하는 연직차수벽의 현장 투수계수 산정법 (Modification of Bouwer and Rice Method to Evaluate Hydraulic Conductivity of Cutoff Wall Considering Filter Cake Development)

  • 웽테바오;이철호;곽태훈;최항석
    • 한국지반공학회논문집
    • /
    • 제25권12호
    • /
    • pp.47-55
    • /
    • 2009
  • 순간변위시험(Slug test)을 통해 대수층의 투수계수를 구할 때, 시험결과 해석에 적용하는 line-fitting법 중 가장 일반적인 방법이 Bouwer and Rice법이다. Bouwer and Rice법을 적용하여 압축성이 크고 벽체의 두께가 얇은 연직차수벽의 투수계수를 산정할 때는 세심한 주의가 필요하다. 그리고 연직 차수벽과 주변 지반 사이에 형성된 상대적으로 투수성이 낮은 영역, 즉 필터케이크(Filter cake)는 Bouwer and Rice법을 연직차수벽의 투수계수 산정시, 이 방법을 직접적용하기 어렵게 만든다. 본 논문에서는 기존의 Bouwer and Rice법의 한계를 극복하기 위해서 유선망 개념을 도입한 수정 Bouwer and Rice법을 제안하였다. 수정된 Bouwer and Rice법은 연직차수벽의 투수계수를 산정할 때 필터케이크를 포함한 연직차수벽의 기하학적 조건을 효율적으로 반영할 수 있도록 한다. 또한, 수정 Bouwer and Rice법의 적용성을 검증하기 위한 사례 연구가 본 논문에서 수행되었다.